Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
Add more filters










Publication year range
1.
Sci Rep ; 10(1): 1328, 2020 Jan 28.
Article in English | MEDLINE | ID: mdl-31992730

ABSTRACT

A binary metallic superoscillatory lens assisted with annular subwavelength slits is proposed, which generates a longitudinally-polarized super-resolution focal point. The annular slits are designed to selectively transmit radially-polarized light. Simulations using the finite element method show a 0.24 λ focal spot with 21.8 dB of polarization purity and only 0.342 dB reduction in efficiency compared to a standard superoscillatory lens.

2.
Light Sci Appl ; 8: 2, 2019.
Article in English | MEDLINE | ID: mdl-30622705

ABSTRACT

Evanescent light can be localized at the nanoscale by resonant absorption in a plasmonic nanoparticle or taper or by transmission through a nanohole. However, a conventional lens cannot focus free-space light beyond half of the wavelength λ. Nevertheless, precisely tailored interference of multiple waves can form a hotspot in free space of an arbitrarily small size, which is known as superoscillation. Here, we report a new type of integrated metasurface interferometry that allows for the first time mapping of fields with a deep subwavelength resolution ~λ/100. The findings reveal that an electromagnetic field near the superoscillatory hotspot has many features similar to those found near resonant plasmonic nanoparticles or nanoholes: the hotspots are surrounded by nanoscale phase singularities and zones where the phase of the superoscillatory field changes more than tenfold faster than a free-propagating plane wave. Areas with high local wavevectors are pinned to phase vortices and zones of energy backflow (~λ/20 in size) that contribute to tightening of the main focal spot size beyond the Abbe-Rayleigh limit. Our observations reveal some analogy between plasmonic nanofocusing of evanescent waves and superoscillatory nanofocusing of free-space waves and prove the fundamental link between superoscillations and superfocusing, offering new opportunities for nanoscale metrology and imaging.

3.
Opt Express ; 26(7): 8095-8112, 2018 Apr 02.
Article in English | MEDLINE | ID: mdl-29715782

ABSTRACT

Optical superoscillatory imaging, allowing unlabelled far-field super-resolution, has in recent years become reality. Instruments have been built and their super-resolution imaging capabilities demonstrated. The question is no longer whether this can be done, but how well: what resolution is practically achievable? Numerous works have optimised various particular features of superoscillatory spots, but in order to probe the limits of superoscillatory imaging we need to simultaneously optimise all the important spot features: those that define the resolution of the system. We simultaneously optimise spot size and its intensity relative to the sidebands for various fields of view, giving a set of best compromises for use in different imaging scenarios. Our technique uses the circular prolate spheroidal wave functions as a basis set on the field of view, and the optimal combination of these, representing the optimal spot, is found using a multi-objective genetic algorithm. We then introduce a less computationally demanding approach suitable for real-time use in the laboratory which, crucially, allows independent control of spot size and field of view. Imaging simulations demonstrate the resolution achievable with these spots. We show a three-order-of-magnitude improvement in the efficiency of focusing to achieve the same resolution as previously reported results, or a 26 % increase in resolution for the same efficiency of focusing.

4.
Front Neurosci ; 12: 1048, 2018.
Article in English | MEDLINE | ID: mdl-30697145

ABSTRACT

Neuroprostheses designed to interface with the nervous system to replace injured or missing senses can significantly improve a patient's quality of life. The challenge remains to provide implants that operate optimally over several decades. Changes in the implant-tissue interface may precede performance problems. Tools to identify and characterize such changes using existing clinical measures would be highly valuable. Modern cochlear implant (CI) systems allow easy and regular measurements of electrode impedance (EI). This measure is routinely performed as a hardware integrity test, but it also allows a level of insight into the immune-mediated response to the implant, which is associated with performance outcomes. This study is a 5-year retrospective investigation of MED-EL CI users at the University of Southampton Auditory Implant Service including 176 adult ears (18-91) and 74 pediatric ears (1-17). The trend in EI in adults showed a decrease at apical electrodes. An increase was seen at the basal electrodes which are closest to the surgery site. The trend in the pediatric cohort was increasing EI over time for nearly all electrode positions, although this group showed greater variability and had a smaller sample size. We applied an outlier-labeling rule to statistically identify individuals that exhibit raised impedance. This highlighted 14 adult ears (8%) and 3 pediatric ears (5%) with impedance levels that deviated from the group distribution. The slow development of EI suggests intra-cochlear fibrosis and/or osteogenesis as the underlying mechanism. The usual clinical intervention for extreme impedance readings is to deactivate the relevant electrode. Our findings highlight some interesting clinical contradictions: some cases with raised (but not extreme) impedance had not prompted an electrode deactivation; and many cases of electrode deactivation had been informed by subjective patient reports. This emphasizes the need for improved objective evidence to inform electrode deactivations in borderline cases, for which our outlier-labeling approach is a promising candidate. A data extraction and analysis protocol that allows ongoing and automated statistical analysis of routinely collected data could benefit both the CI and wider neuroprosthetics communities. Our approach provides new tools to inform practice and to improve the function and longevity of neuroprosthetic devices.

5.
Opt Express ; 24(16): 18790-8, 2016 Aug 08.
Article in English | MEDLINE | ID: mdl-27505842

ABSTRACT

Dynamic control over optical wavefronts enables focusing, diffraction and redirection of light on demand, however, sub-wavelength resolution is required to avoid unwanted diffracted beams that are present in commercial spatial light modulators. Here we propose a realistic metadevice that dynamically controls the optical phase of reflected beams with sub-wavelength pixelation in one dimension. Based on reconfigurable metamaterials and nanomembrane technology, it consists of individually moveable metallic nanowire actuators that control the phase of reflected light by modulating the optical path length. We demonstrate that the metadevice can provide on-demand optical wavefront shaping functionalities of diffraction gratings, beam splitters, phase-gradient metasurfaces, cylindrical mirrors and mirror arrays - with variable focal distance and numerical aperture - without unwanted diffraction.

6.
Opt Express ; 22(17): 21051-60, 2014 Aug 25.
Article in English | MEDLINE | ID: mdl-25321305

ABSTRACT

It was recently demonstrated that the well-known Snell's law must be corrected for phase gradient metasurfaces to account for their spatially varying phase, leading to normal and anomalous transmission and reflection of light on such metasurfaces. Here we show that the efficiency of normal and anomalous transmission and reflection of light can be controlled by the intensity or phase of a second coherent wave. The phenomenon is illustrated using gradient metasurfaces based on V-shaped and rectangular apertures in a metal film. This coherent control effect can be exploited for wave front shaping and signal routing.

7.
Sci Rep ; 4: 6333, 2014 Sep 11.
Article in English | MEDLINE | ID: mdl-25208611

ABSTRACT

Planar optical lenses are fundamental elements of miniaturized photonic devices. However, conventional planar optical lenses are constrained by the diffraction limit in the optical far-field due to the band-limited wavevectors supported by free-space and loss of high-spatial-frequency evanescent components. As inspired by Einstein's radiation 'needle stick', electromagnetic energy can be delivered into an arbitrarily small solid angle. Such sub-diffraction optical needles have been numerically investigated using diffractive optical elements (DOEs) together with specially polarized optical beams, but experimental demonstration is extremely difficult due to the bulky size of DOEs and the required alignment precision. Planar super-oscillatory lenses (SOLs) were proposed to overcome these constraints and demonstrated that sub-diffraction focal spots can actually be formed without any evanescent waves, making far-field, label-free super-resolution imaging possible. Here we extend the super-oscillation concept into the vectorial-field regime to work with circularly polarized light, and experimentally demonstrate, for the first time, a circularly polarized optical needle with sub-diffraction transverse spot size (0.45λ) and axial long depth of focus (DOF) of 15λ using a planar SOL at a violet wavelength of 405 nm. This sub-diffraction circularly polarized optical needle has potential applications in circular dichroism spectroscopy, super-resolution imaging, high-density optical storage, heat-assisted magnetic recording, nano-manufacturing and nano-metrology.

8.
Opt Express ; 22(6): 6428-37, 2014 Mar 24.
Article in English | MEDLINE | ID: mdl-24663991

ABSTRACT

Heat-assisted magnetic recording (HAMR) is a future roadmap technology to overcome the superparamagnetic limit in high density magnetic recording. Existing HAMR schemes depend on a simultaneous magnetic stimulation and light-induced local heating of the information carrier. To achieve high-density recorded data, near-field plasmonic transducers have been proposed as light concentrators. Here we suggest and investigate in detail an alternative approach exploiting a far-field focusing device that can focus light into sub-50 nm hot-spots in the magnetic recording layer using a laser source operating at 473 nm. It is based on a recently introduced super-oscillatory flat lens improved with the use of solid immersion, giving an effective numerical aperture as high as 4.17. The proposed solution is robust and easy to integrate with the magnetic recording head thus offering a competitive advantage over plasmonic technology.

9.
Opt Express ; 21(6): 7577-82, 2013 Mar 25.
Article in English | MEDLINE | ID: mdl-23546140

ABSTRACT

We show that a planar plasmonic metamaterial with spatially variable meta-atom parameters can focus transmitted light into sub-wavelength hot-spots located beyond the near-field of the metamaterial. By nano-structuring a gold film we created an array of meta-lenses generating foci of 160 nm (0.2λ) in diameter when illuminated by a wavelength of 800 nm. We attribute the occurrence of sub-wavelength hotspots beyond the near field to the phenomenon of superoscillation.


Subject(s)
Gold/chemistry , Lenses , Membranes, Artificial , Metal Nanoparticles/chemistry , Metal Nanoparticles/ultrastructure , Surface Plasmon Resonance/instrumentation , Equipment Design , Equipment Failure Analysis
10.
Nat Mater ; 11(5): 432-5, 2012 Mar 25.
Article in English | MEDLINE | ID: mdl-22447113

ABSTRACT

The past decade has seen an intensive effort to achieve optical imaging resolution beyond the diffraction limit. Apart from the Pendry-Veselago negative index superlens, implementation of which in optics faces challenges of losses and as yet unattainable fabrication finesse, other super-resolution approaches necessitate the lens either to be in the near proximity of the object or manufactured on it, or work only for a narrow class of samples, such as intensely luminescent or sparse objects. Here we report a new super-resolution microscope for optical imaging that beats the diffraction limit of conventional instruments and the recently demonstrated near-field optical superlens and hyperlens. This non-invasive subwavelength imaging paradigm uses a binary amplitude mask for direct focusing of laser light into a subwavelength spot in the post-evanescent field by precisely tailoring the interference of a large number of beams diffracted from a nanostructured mask. The new technology, which--in principle--has no physical limits on resolution, could be universally used for imaging at any wavelength and does not depend on the luminescence of the object, which can be tens of micrometres away from the mask. It has been implemented as a straightforward modification of a conventional microscope showing resolution better than λ/6.

11.
Opt Lett ; 31(3): 374-6, 2006 Feb 01.
Article in English | MEDLINE | ID: mdl-16480213

ABSTRACT

Coherent soft x rays are produced by high-harmonic generation in a capillary filled with Ar gas. We demonstrate that the tuning of the harmonic wavelengths with intensity and chirp arises from changes in the Ar ionization level. Control over the tuning can be achieved either by changing the average intensity of the laser pulse or by varying the quadratic spectral phase of the laser pulse. We observe an ionization-dependent blueshift of the fundamental wavelength that is directly imprinted on the harmonic wavelengths. The harmonic tuning is shown to depend on nonlinear spectral shifts of the fundamental laser pulse that are due to the plasma created by ionization, rather than directly on any chirp imposed on the fundamental wavelength.

SELECTION OF CITATIONS
SEARCH DETAIL
...