Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
1.
Rev Peru Med Exp Salud Publica ; 41(1): 76-82, 2024 May 27.
Article in Spanish, English | MEDLINE | ID: mdl-38808849

ABSTRACT

The present study assessed the diagnostic performance of the Xpert®Xpress SARS-CoV-2 test in comparison with the Charité protocol real-time RT PCR for the detection of SARS-CoV-2 in Peruvian patients. This was a diagnostic test study that included 100 nasal and pharyngeal swab samples. We obtained an overall concordance of 98.70% (95%CI: 92.98-99.97), with a kappa coefficient of 0.97 (95%CI: 0.86-1.00) and sensitivity and relative specificity rates of 100% and 96.15%, respectively. Additionally, the percentage of the area under the ROC curve was 98.08% in both cases, and an analytical specificity rate of 100% was obtained for the different respiratory viruses evaluated. In conclusion, the Xpert®Xpress SARS-CoV-2 test, by using nasal and pharyngeal swab samples, was highly sensitive and specific, and the kappa coefficient showed an excellent correlation when compared to the reference test. Motivation for the study. To describe and evaluate a closed molecular platform, easy to use and of importance in Peru for the management of diseases of public health priority, now implemented for the detection of SARS-CoV-2. Main findings. Highly sensitive and specific molecular test, with excellent correlation compared to the reference test for detecting SARS-CoV-2. Implications. Can be used in point-of-care laboratories for rapid molecular detection of different infectious agents, including SARS-CoV-2. Little expertise and minimal infrastructure are required to implement it.


En el presente estudio se estimó el rendimiento diagnóstico de la prueba Xpert®Xpress SARS-CoV-2 en comparación con la RT PCR en tiempo real-protocolo Charité, para la detección de SARS-CoV-2 en pacientes peruanos. Se trató de un diseño de prueba diagnóstica que incluyó 100 muestras de hisopado nasal y faríngeo. Se obtuvo una concordancia global de 98,70% (IC95%: 92,98-99,97), con un coeficiente kappa de 0,97 (IC95%: 0,86-1.00); se estimó una sensibilidad y especificad relativa de 100% y 96,15%, respectivamente. Adicionalmente, el porcentaje del área bajo la curva ROC fue 98,08% en ambos casos y se obtuvo una especificidad analítica del 100% para los diferentes virus respiratorios evaluados. En conclusión, la prueba Xpert®Xpress SARS-CoV-2 a partir de muestras de hisopado nasal y faríngeo fue altamente sensible y específica, así mismo el coeficiente kappa mostró una excelente correlación, al compararla con la prueba de referencia. Motivación para realizar el estudio. Descripción y evaluación de una plataforma molecular cerrada, de fácil uso y de importancia en el Perú para el manejo de enfermedades de prioridad en salud pública, ahora implementada para la detección de SARS-CoV-2. Principales hallazgos. Prueba molecular altamente sensible y específica, con una correlación excelente con respecto al referente para detectar SARS-CoV-2. Implicancias. Puede ser utilizada en los laboratorios que se encuentran en los puntos de atención del paciente para la detección molecular rápida de diferentes agentes infecciosos, incluido el SARS-CoV-2. Se necesita poca experticia y mínima infraestructura para poder implementarla.


Subject(s)
COVID-19 , SARS-CoV-2 , Sensitivity and Specificity , Humans , Peru , COVID-19/diagnosis , SARS-CoV-2/isolation & purification , COVID-19 Nucleic Acid Testing/methods , Pharynx/virology , Point-of-Care Systems , Real-Time Polymerase Chain Reaction , Point-of-Care Testing
2.
J Med Virol ; 94(10): 4689-4695, 2022 10.
Article in English | MEDLINE | ID: mdl-35644902

ABSTRACT

The massive sequencing of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and global genomic surveillance strategies allowed the detection of many variants of concern and interest. The variant of interest Lambda (C.37), which originated in South America, has been the most prevalent in Peru and Chile, but its dispersion in other continents still remains unknown. The current study aims to determine the phylogenetic relationship among C.37 isolates worldwide, focusing on spike mutations to understand the spread of Lambda in pandemics. A total of 7441 sequences identified as C.37 were downloaded from the GISAID database; local analysis was carried out to identify spike mutations and phylogenetic analysis was carried out to determine the rate of spread of the virus. Our results showed some spike mutations of Lambda that allowed us to detect small local outbreaks in different countries that occurred in the past and identify several clades that have not yet been designated. Although the lineage C.37 is not epidemiologically relevant in Europe or North America, the endemic behavior of this variant in Peru had a major impact on the second SARS-CoV-2 wave.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19/epidemiology , Chile , Genome, Viral , Genomics , Humans , Mutation , Phylogeny , SARS-CoV-2/genetics , Spike Glycoprotein, Coronavirus/genetics
3.
Rev Peru Med Exp Salud Publica ; 39(1): 104-110, 2022.
Article in Spanish, English | MEDLINE | ID: mdl-35766727

ABSTRACT

In Peru, the COVID-19 pandemic demonstrated the usefulness of having a structured laboratory surveillance system that has been operational for 22 years, based on influenza surveillance; initially in the form of sentinel units, and later strengthened and innovated, with its own resources and with external support, to provide quality information. Biotechnological advances have been implemented for diagnostic confirmation and the capacity of the national laboratory network has been expanded, maintaining efficiency, considering the diverse and complex realities of each region, and overcoming difficulties regarding communication and articulation between institutions. It is necessary to consolidate this system, with collaborative and coordinated work between its components, boosting its effectiveness and timeliness and promoting genomic surveillance of new viruses and variants, as is currently the case with SARS-CoV-2.


En el Perú, la pandemia de la COVID-19 ha evidenciado la utilidad de tener un sistema de vigilancia laboratorial estructurado y en funcionamiento desde hace 22 años, basado en la vigilancia de influenza; inicialmente en modalidad de unidades centinela, y después fortaleciéndose e innovándose, con recursos propios y con apoyo externo, para generar información de calidad. Se han implementado avances biotecnológicos para la confirmación diagnóstica e incrementado las capacidades de la red nacional de laboratorios, manteniendo la eficiencia, considerando las diversas y complejas realidades de los niveles regionales, y superando dificultades de comunicación y articulación entre instituciones. Resulta necesario consolidar este sistema, con trabajo colaborativo y coordinado entre sus componentes, impulsando su eficacia y oportunidad y promoviendo la vigilancia genómica de nuevos virus y variantes, como actualmente ocurre con el SARS-CoV-2.


Subject(s)
COVID-19 , Influenza, Human , COVID-19/diagnosis , COVID-19/epidemiology , Humans , Influenza, Human/diagnosis , Influenza, Human/epidemiology , Pandemics , Peru/epidemiology , SARS-CoV-2
4.
Open Forum Infect Dis ; 9(6): ofac134, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35615298

ABSTRACT

Background: Coronavirus disease 2019 (COVID-19) infection is a major public health problem in the world and reinfections are becoming more frequent. Our main objective was to describe the epidemiological, clinical, and genomic characteristics of the confirmed cases of reinfection by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in the capital of Lima and Callao, Peru. Methods: We searched in the Peruvian laboratory information system from April 2020 up to May 2021, looking for cases having 2 positive molecular tests for SARS-CoV-2 with more than 90 days between them. We performed genomic sequencing to the available pairs of samples and described the clinical characteristics, epidemiological impact, and genomic analysis of the confirmed reinfections. Results: There were 1 694 164 people with a positive diagnostic test for SARS-CoV-2 in Lima/Callao during the study period. Of these, 1695 had 2 positive molecular tests with more than 90 days between them. Two hundred eleven had both samples available for genomic analysis according to our selection criteria, and these were retrieved and submitted to sequencing. Thirty cases were confirmed to be SARS-CoV-2 reinfections with 2 different lineages in the 2 episodes. The variant Lambda (C.37) was the most common during the second infection and accounted for 19 (63.3%) of the 30 cases. Conclusions: We report 30 cases of confirmed SARS-CoV-2 reinfections. The Lambda variant was the most common cause of the second infections, in concordance with its predominant circulation during Peru's second wave. This report describes the largest series of confirmed reinfections by SARS-CoV-2 in Latin America.We describe the epidemiological, clinical, and genomic characteristics of the confirmed cases of reinfection by severe acute respiratory syndrome coronavirus 2 in Lima and Callao, durante la segunda ola en Peru. The Lambda variant (C.37) was the most common cause of the second infections.

5.
Rev. peru. med. exp. salud publica ; 39(1): 104-110, ene.-mar. 2022. tab, graf
Article in Spanish | LILACS | ID: biblio-1389935

ABSTRACT

RESUMEN En el Perú, la pandemia de la COVID-19 ha evidenciado la utilidad de tener un sistema de vigilancia laboratorial estructurado y en funcionamiento desde hace 22 años, basado en la vigilancia de influenza; inicialmente en modalidad de unidades centinela, y después fortaleciéndose e innovándose, con recursos propios y con apoyo externo, para generar información de calidad. Se han implementado avances biotecnológicos para la confirmación diagnóstica e incrementado las capacidades de la red nacional de laboratorios, manteniendo la eficiencia, considerando las diversas y complejas realidades de los niveles regionales, y superando dificultades de comunicación y articulación entre instituciones. Resulta necesario consolidar este sistema, con trabajo colaborativo y coordinado entre sus componentes, impulsando su eficacia y oportunidad y promoviendo la vigilancia genómica de nuevos virus y variantes, como actualmente ocurre con el SARS-CoV-2.


ABSTRACT In Peru, the COVID-19 pandemic demonstrated the usefulness of having a structured laboratory surveillance system that has been operational for 22 years, based on influenza surveillance; initially in the form of sentinel units, and later strengthened and innovated, with its own resources and with external support, to provide quality information. Biotechnological advances have been implemented for diagnostic confirmation and the capacity of the national laboratory network has been expanded, maintaining efficiency, considering the diverse and complex realities of each region, and overcoming difficulties regarding communication and articulation between institutions. It is necessary to consolidate this system, with collaborative and coordinated work between its components, boosting its effectiveness and timeliness and promoting genomic surveillance of new viruses and variants, as is currently the case with SARS-CoV-2.


Subject(s)
Viruses , Epidemiologic Surveillance Services , Public Health Surveillance , SARS-CoV-2 , Influenza A virus , Influenza B virus , Health Surveillance , Molecular Diagnostic Techniques , Public Health Laboratory Services , National Health Systems , Epidemiological Monitoring , COVID-19 Testing
7.
Rev. peru. med. exp. salud publica ; 38(4): 595-600, oct.-dic. 2021. tab, graf
Article in Spanish | LILACS | ID: biblio-1365933

ABSTRACT

RESUMEN Se validó y evaluó un método de RT-PCR en tiempo real usando cebadores y sondas específicas para los genes RdRP de SARS-CoV-2 y GAPDH de humanos; este último fue usado como control endógeno. Se evaluó la especificidad y sensibilidad; además, se evaluó otros parámetros como la robustez, la repetibilidad, reproducibilidad, comparabilidad y el límite de detección. La sensibilidad, especificidad, los valores predictivos positivo y negativo, la robustez, comparabilidad y la repetibilidad-reproducibilidad de la prueba de RT-PCR en tiempo real dúplex fue de 100%, con un límite de detección de 100 copias/µL, de acuerdo con los criterios de aceptación establecidos para validación del protocolo. Esta prueba estandarizada es una buena alternativa para el diagnóstico de COVID-19; además, la prueba fue aplicada de manera exitosa en personas sospechosas de la enfermedad permitiendo controlar el número de falsos negativos.


ABSTRACT The present work validated and evaluated a duplex real-time RT-PCR using specific primers and probes for genes RdRp from SARS-CoV-2 and GAPDH from humans; the latter was used as an endogenous control in all reactions. We evaluated the specificity, the sensitivity, the robustness, the reproducibility, the repeatability, the comparability, and the limit of detection. The predictive positive and negative values (PPV and PNV, respectively) and all the parameters evaluated using our duplex real-time RT-PCR was 100%. The detection limit was 100 copies/µL according to the acceptance criteria established for the validation of this protocol. Our duplex real-time RT-PCR demonstrated to be a good alternative for the diagnosis of COVID-19; in addition, this PCR was used adequately in suspicion of COVID-19, allowing it to control the number of false-negatives.


Subject(s)
Validation Study , Molecular Diagnostic Techniques , SARS-CoV-2 , COVID-19 Testing , COVID-19
8.
J Med Virol ; 93(12): 6845-6849, 2021 12.
Article in English | MEDLINE | ID: mdl-34370324

ABSTRACT

The pandemic generated by SARS-Cov-2 has caused a large number of cases and deaths in the world, but South America has been one of the continents that were most hard hit. The appearance of new variants causes concern because of the possibility that they may evade the protection generated by vaccination campaigns, their greater capacity to be transmitted, or their higher virulence. We analyzed the circulating variants in Peru after improving our Genomic Surveillance program. The results indicate a steep increase of the lambda lineage (C.37) until becoming predominant between January and April 2021, despite the cocirculation of other variants of concern or interest. Lambda lineage deserves close monitoring and could probably become a variant of concern in the near future.


Subject(s)
COVID-19/epidemiology , Genome, Viral/genetics , SARS-CoV-2/genetics , COVID-19/virology , Genomics/methods , Humans , Mutation/genetics , Pandemics/prevention & control , Peru/epidemiology
9.
Article in Spanish, English | MEDLINE | ID: mdl-34190927

ABSTRACT

OBJECTIVES: To standardize and validate an in-house RT-LAMP test for the detection of SARS-CoV-2, based on laboratory and field assays using samples from COVID-19 suspected patients. MATERIALS AND METHODS: An in-house SARS-CoV-2 RT-LAMP molecular test was standardized, establishing the detection limit with Vero cells of isolated Peruvian strains of SARS-CoV-2, and the robustness to various concentrations of primers. The laboratory validation was performed with 384 nasal and pharyngeal swab samples (UFH) obtained between March and July 2020. The field validation was performed with 383 UFH obtained from COVID-19 suspected symptomatic cases. All samples were tested by RT-LAMP and RT-qPCR. The RT-qPCR was considered as the reference standard test. The concordance measures and diagnostic performance were calculated. RESULTS: The detection limit was consistent in cases with Ct <30 in both tests, showing efficiency to detect up to 1000 copies/µL of the target gene. Robustness was evidenced with half of the primer concentrations and 20 µL of final volume. Absence of amplification was identified for other HCoVs. Concordance showed a kappa index of 0.88 (95% CI: 0.83-0.93) and 0.89 (95% CI: 0.84 - 0.94) in laboratory and field settings, respectively. The sensitivity value in the laboratory was 87.4% (95% CI: 80.8 - 92.4) and 88.1% in the field (95% CI: 81.6 - 92.9). The specificity value in both settings was 98.8% (95% CI: 96.4-99.7). CONCLUSIONS: The in-house SARS-CoV-2 RT-LAMP test was successfully validated based on its adequate robustness, no cross-reactions, good concordance, and diagnostic performance compared to RT-qPCR.


OBJETIVOS: Estandarizar una prueba RT-LAMP in house para la detección de SARS-CoV-2 y validarla con muestras de laboratorio y de campo en pacientes con sospecha clínica de COVID-19. MATERIALES Y MÉTODOS: Se estandarizó una prueba molecular RT-LAMP in house para la detección de SARS-CoV-2 estableciéndose el límite de detección con células Vero de cepas peruanas aisladas de SARS-CoV-2. Se validó la prueba en laboratorio con 384 muestras de hisopado nasal y faríngeo (HNF) obtenidas entre marzo y julio de 2020. Para la validación de campo se obtuvieron muestras de HNF de 383 casos sintomáticos sospechosos de COVID-19. Todas las muestras fueron evaluadas por RT-LAMP y RT-qPCR. Para la validación de laboratorio y de campo se consideró como estándar de referencia al RT-qPCR, se calcularon medidas de concordancia y rendimiento diagnóstico. RESULTADOS: El límite de detección fue consistente en los casos con umbral de ciclo (Ct) Ct < 30 en ambas pruebas, mostrando eficiencia para detectar hasta 1000 copias/µL del gen diana. Se evidenció robustez con la mitad de las concentraciones de cebadores y 20 µL de volumen final. Se identificó ausencia de amplificación para otros coronavirus humanos. La concordancia en laboratorio obtuvo un Kappa de 0,88 (IC 95%: 0,83-0,93) y en campo fue de 0,89 (IC 95%: 0,84−0,94); la sensibilidad en laboratorio fue de 87,4% (IC 95%: 80,8−92,4) y en campo fue de 88,1% (IC 95%: 81,6−92,9), la especificidad en ambos escenarios fue de 98,8% (IC 95%: 96,4−99,7). CONCLUSIONES: La prueba RT-LAMP in house fue validada por presentar una adecuada robustez, sin reacciones cruzadas, buena concordancia y rendimiento diagnóstico comparado con el RT-qPCR.


Subject(s)
COVID-19 , SARS-CoV-2 , Animals , Chlorocebus aethiops , Humans , Molecular Diagnostic Techniques , Nucleic Acid Amplification Techniques , RNA, Viral , Reference Standards , Sensitivity and Specificity , Vero Cells
10.
PLoS One ; 16(3): e0248885, 2021.
Article in English | MEDLINE | ID: mdl-33760876

ABSTRACT

One of the biggest challenges during the pandemic has been obtaining and maintaining critical material to conduct the increasing demand for molecular tests. Sometimes, the lack of suppliers and the global shortage of these reagents, a consequence of the high demand, make it difficult to detect and diagnose patients with suspected SARS-CoV-2 infection, negatively impacting the control of virus spread. Many alternatives have enabled the continuous processing of samples and have presented a decrease in time and cost. These measures thus allow broad testing of the population and should be ideal for controlling the disease. In this sense, we compared the SARS-CoV-2 molecular detection effectiveness by Real time RT-PCR using two different protocols for RNA extraction. The experiments were conducted in the National Institute of Health (INS) from Peru. We compared Ct values average (experimental triplicate) results from two different targets, a viral and internal control. All samples were extracted in parallel using a commercial kit and our alternative protocol-samples submitted to proteinase K treatment (3 µg/µL, 56°C for 10 minutes) followed by thermal shock (98°C for 5 minutes followed by 4°C for 2 minutes); the agreement between results was 100% in the samples tested. In addition, we compared the COVID-19 positivity between six epidemiological weeks: the initial two in that the Real time RT-PCR reactions were conducted using RNA extracted by commercial kit, followed by two other using RNA obtained by our kit-free method, and the last two using kit once again; they did not differ significantly. We concluded that our in-house method is an easy, fast, and cost-effective alternative method for extracting RNA and conducing molecular diagnosis of COVID-19.


Subject(s)
COVID-19 Testing/methods , COVID-19/diagnosis , RNA, Viral/isolation & purification , Clinical Laboratory Techniques/methods , Diagnostic Tests, Routine/methods , Endopeptidase K/metabolism , Humans , Pandemics , Peru/epidemiology , RNA/genetics , RNA/isolation & purification , RNA, Viral/genetics , Real-Time Polymerase Chain Reaction/methods , SARS-CoV-2/genetics
11.
Rev. peru. med. exp. salud publica ; 38(1): 7-16, ene-mar 2021. tab, graf
Article in Spanish | LILACS, LIPECS | ID: biblio-1280581

ABSTRACT

RESUMEN Objetivos: Estandarizar una prueba RT-LAMP in house para la detección de SARS-CoV-2 y validarla con muestras de laboratorio y de campo en pacientes con sospecha clínica de COVID-19. Materiales y métodos: Se estandarizó una prueba molecular RT-LAMP in house para la detección de SARS-CoV-2 estableciéndose el límite de detección con células Vero de cepas peruanas aisladas de SARS-CoV-2. Se validó la prueba en laboratorio con 384 muestras de hisopado nasal y faríngeo (HNF) obtenidas entre marzo y julio de 2020. Para la validación de campo se obtuvieron muestras de HNF de 383 casos sintomáticos sospechosos de COVID-19. Todas las muestras fueron evaluadas por RT-LAMP y RT-qPCR. Para la validación de laboratorio y de campo se consideró como estándar de referencia al RT-qPCR, se calcularon medidas de concordancia y rendimiento diagnóstico. Resultados: El límite de detección fue consistente en los casos con umbral de ciclo (Ct) Ct < 30 en ambas pruebas, mostrando eficiencia para detectar hasta 1000 copias/µL del gen diana. Se evidenció robustez con la mitad de las concentraciones de cebadores y 20 µL de volumen final. Se identificó ausencia de amplificación para otros coronavirus humanos. La concordancia en laboratorio obtuvo un Kappa de 0,88 (IC 95%: 0,83-0,93) y en campo fue de 0,89 (IC 95%: 0,84−0,94); la sensibilidad en laboratorio fue de 87,4% (IC 95%: 80,8−92,4) y en campo fue de 88,1% (IC 95%: 81,6−92,9), la especificidad en ambos escenarios fue de 98,8% (IC 95%: 96,4−99,7). Conclusiones: La prueba RT-LAMP in house fue validada por presentar una adecuada robustez, sin reacciones cruzadas, buena concordancia y rendimiento diagnóstico comparado con el RT-qPCR.


ABSTRACT Objectives: To standardize and validate an in-house RT-LAMP test for the detection of SARS-CoV-2, based on laboratory and field assays using samples from COVID-19 suspected patients. Materials and methods: An in-house SARS-CoV-2 RT-LAMP molecular test was standardized, establishing the detection limit with Vero cells of isolated Peruvian strains of SARS-CoV-2, and the robustness to various concentrations of primers. The laboratory validation was performed with 384 nasal and pharyngeal swab samples (UFH) obtained between March and July 2020. The field validation was performed with 383 UFH obtained from COVID-19 suspected symptomatic cases. All samples were tested by RT-LAMP and RT-qPCR. The RT-qPCR was considered as the reference standard test. The concordance measures and diagnostic performance were calculated. Results: The detection limit was consistent in cases with Ct <30 in both tests, showing efficiency to detect up to 1000 copies/μL of the target gene. Robustness was evidenced with half of the primer concentrations and 20 μL of final volume. Absence of amplification was identified for other HCoVs. Concordance showed a kappa index of 0.88 (95% CI: 0.83-0.93) and 0.89 (95% CI: 0.84 - 0.94) in laboratory and field settings, respectively. The sensitivity value in the laboratory was 87.4% (95% CI: 80.8 - 92.4) and 88.1% in the field (95% CI: 81.6 - 92.9). The specificity value in both settings was 98.8% (95% CI: 96.4-99.7). Conclusions: The in-house SARS-CoV-2 RT-LAMP test was successfully validated based on its adequate robustness, no cross-reactions, good concordance, and diagnostic performance compared to RT-qPCR.


Subject(s)
Validation Study , Molecular Diagnostic Techniques , SARS-CoV-2 , Laboratories , Patients , Polymerase Chain Reaction , Predictive Value of Tests , ROC Curve , Sensitivity and Specificity , Cross Reactions , Diagnosis , COVID-19
12.
Rev. peru. med. exp. salud publica ; 38(1): 7-16, ene-mar 2021. tab, graf
Article in Spanish | LILACS | ID: biblio-1280540

ABSTRACT

RESUMEN Objetivos: Estandarizar una prueba RT-LAMP in house para la detección de SARS-CoV-2 y validarla con muestras de laboratorio y de campo en pacientes con sospecha clínica de COVID-19. Materiales y métodos: Se estandarizó una prueba molecular RT-LAMP in house para la detección de SARS-CoV-2 estableciéndose el límite de detección con células Vero de cepas peruanas aisladas de SARS-CoV-2. Se validó la prueba en laboratorio con 384 muestras de hisopado nasal y faríngeo (HNF) obtenidas entre marzo y julio de 2020. Para la validación de campo se obtuvieron muestras de HNF de 383 casos sintomáticos sospechosos de COVID-19. Todas las muestras fueron evaluadas por RT-LAMP y RT-qPCR. Para la validación de laboratorio y de campo se consideró como estándar de referencia al RT-qPCR, se calcularon medidas de concordancia y rendimiento diagnóstico. Resultados: El límite de detección fue consistente en los casos con umbral de ciclo (Ct) Ct < 30 en ambas pruebas, mostrando eficiencia para detectar hasta 1000 copias/µL del gen diana. Se evidenció robustez con la mitad de las concentraciones de cebadores y 20 µL de volumen final. Se identificó ausencia de amplificación para otros coronavirus humanos. La concordancia en laboratorio obtuvo un Kappa de 0,88 (IC 95%: 0,83-0,93) y en campo fue de 0,89 (IC 95%: 0,84−0,94); la sensibilidad en laboratorio fue de 87,4% (IC 95%: 80,8−92,4) y en campo fue de 88,1% (IC 95%: 81,6−92,9), la especificidad en ambos escenarios fue de 98,8% (IC 95%: 96,4−99,7). Conclusiones: La prueba RT-LAMP in house fue validada por presentar una adecuada robustez, sin reacciones cruzadas, buena concordancia y rendimiento diagnóstico comparado con el RT-qPCR.


ABSTRACT Objectives: To standardize and validate an in-house RT-LAMP test for the detection of SARS-CoV-2, based on laboratory and field assays using samples from COVID-19 suspected patients. Materials and methods: An in-house SARS-CoV-2 RT-LAMP molecular test was standardized, establishing the detection limit with Vero cells of isolated Peruvian strains of SARS-CoV-2, and the robustness to various concentrations of primers. The laboratory validation was performed with 384 nasal and pharyngeal swab samples (UFH) obtained between March and July 2020. The field validation was performed with 383 UFH obtained from COVID-19 suspected symptomatic cases. All samples were tested by RT-LAMP and RT-qPCR. The RT-qPCR was considered as the reference standard test. The concordance measures and diagnostic performance were calculated. Results: The detection limit was consistent in cases with Ct <30 in both tests, showing efficiency to detect up to 1000 copies/μL of the target gene. Robustness was evidenced with half of the primer concentrations and 20 μL of final volume. Absence of amplification was identified for other HCoVs. Concordance showed a kappa index of 0.88 (95% CI: 0.83-0.93) and 0.89 (95% CI: 0.84 - 0.94) in laboratory and field settings, respectively. The sensitivity value in the laboratory was 87.4% (95% CI: 80.8 - 92.4) and 88.1% in the field (95% CI: 81.6 - 92.9). The specificity value in both settings was 98.8% (95% CI: 96.4-99.7). Conclusions: The in-house SARS-CoV-2 RT-LAMP test was successfully validated based on its adequate robustness, no cross-reactions, good concordance, and diagnostic performance compared to RT-qPCR.


Subject(s)
Reference Standards , Molecular Diagnostic Techniques , Diagnosis , SARS-CoV-2 , Patients , Polymerase Chain Reaction , Predictive Value of Tests , ROC Curve , Sensitivity and Specificity , Cross Reactions , COVID-19
13.
Rev Peru Med Exp Salud Publica ; 38(4): 595-600, 2021.
Article in Spanish, English | MEDLINE | ID: mdl-35385012

ABSTRACT

The present work validated and evaluated a duplex real-time RT-PCR using specific primers and probes for genes RdRp from SARS-CoV-2 and GAPDH from humans; the latter was used as an endogenous control in all reactions. We evaluated the specificity, the sensitivity, the robustness, the reproducibility, the repeatability, the comparability, and the limit of detection. The predictive positive and negative values (PPV and PNV, respectively) and all the parameters evaluated using our duplex real-time RT-PCR was 100%. The detection limit was 100 copies/µL according to the acceptance criteria established for the validation of this protocol. Our duplex real-time RT-PCR demonstrated to be a good alternative for the diagnosis of COVID-19; in addition, this PCR was used adequately in suspicion of COVID-19, allowing it to control the number of false-negatives.


Se validó y evaluó un método de RT-PCR en tiempo real usando cebadores y sondas específicas para los genes RdRP de SARS-CoV-2 y GAPDH de humanos; este último fue usado como control endógeno. Se evaluó la especificidad y sensibilidad; además, se evaluó otros parámetros como la robustez, la repetibilidad, reproducibilidad, comparabilidad y el límite de detección. La sensibilidad, especificidad, los valores predictivos positivo y negativo, la robustez, comparabilidad y la repetibilidad-reproducibilidad de la prueba de RT-PCR en tiempo real dúplex fue de 100%, con un límite de detección de 100 copias/µL, de acuerdo con los criterios de aceptación establecidos para validación del protocolo. Esta prueba estandarizada es una buena alternativa para el diagnóstico de COVID-19; además, la prueba fue aplicada de manera exitosa en personas sospechosas de la enfermedad permitiendo controlar el número de falsos negativos.


Subject(s)
COVID-19 Testing , COVID-19 , SARS-CoV-2 , COVID-19/diagnosis , COVID-19 Testing/methods , COVID-19 Testing/standards , Humans , RNA, Viral/genetics , RNA-Dependent RNA Polymerase , Reproducibility of Results , Reverse Transcriptase Polymerase Chain Reaction , SARS-CoV-2/genetics , Sensitivity and Specificity
14.
Microbiol Resour Announc ; 9(19)2020 May 07.
Article in English | MEDLINE | ID: mdl-32381617

ABSTRACT

A near-complete genome sequence was obtained for a novel coronavirus (SARS-CoV-2) strain obtained from an oropharyngeal swab from a Peruvian patient with coronavirus syndrome (COVID-19) who had contact with an individual who had returned to Peru from travel to Italy.

SELECTION OF CITATIONS
SEARCH DETAIL
...