Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
Add more filters










Publication year range
1.
Pharm Acta Helv ; 66(2): 44-6, 1991.
Article in English | MEDLINE | ID: mdl-1758892

ABSTRACT

Diazepam and its main degradation product 2-methyl-amino-5-chlorobenzophenon (MACB) were quantitatively determined by HPLC and spectrophotometry in one- to ten-years-old diazepam injections. The content of diazepam was within the specifications in all the samples. Not more than 1.5% degradation of diazepam was found after ten years.


Subject(s)
Diazepam/analysis , Diazepam/chemistry , Drug Stability , Injections
2.
Acta Pharm Nord ; 2(5): 319-26, 1990.
Article in English | MEDLINE | ID: mdl-2083036

ABSTRACT

In the seventies, it was shown that particles were generated in soft polyvinyl chloride (PVC) infusion fluid bags when they were shaken. In this investigation an exponentially modified log-normal distribution (EMLN) is fitted to the particle data. Using the formula for the volume of a sphere, the number-density distribution is converted into a volume-density distribution. The total particle load in the samples is estimated by integration for total particle volume. The results are expressed as volume concentration in plain SI-units (microliters/l). A four-factor analysis of variance demonstrates that the mechanism of the contamination process is most probably an emulsification of low molecular weight additives in the PVC plastic, i.e. di(2-ethylhexyl) phthalate (DEHP), epoxidized vegetable oils (EVO), and others.


Subject(s)
Drug Contamination , Infusions, Intravenous/instrumentation , Polyvinyl Chloride/analysis
3.
Acta Pharm Nord ; 2(5): 327-32, 1990.
Article in English | MEDLINE | ID: mdl-2083037

ABSTRACT

About 200 samples of normal saline, isotonic glucose and Ringer acetate infusions in soft polyvinyl chloride (PVC) bags obtained from three manufacturers have been analyzed by conductometric particle counting, turbidimetry and gas liquid chromatography (GLC). The particle counts were fitted to an exponentially modified log-normal model and integrated for total particle-volume. Di(2-ethylhexyl) phthalate (DEHP) and epoxidized vegetable oils (EVO), which are the main water insoluble contaminants in PVC fluid bags, were determined by GLC. There was a strong linear correlation between turbidity and GLC results. The correlation between particle-volume concentration and the DEHP and EVO concentrations was fairly good. The results seem to verify that an emulsion of plastic additives is formed when soft PVC infusion fluid bags are shaken.


Subject(s)
Drug Contamination , Infusions, Intravenous/instrumentation , Polyvinyl Chloride/analysis , Chromatography, Gas , Nephelometry and Turbidimetry
4.
Acta Pharm Nord ; 2(5): 355-62, 1990.
Article in English | MEDLINE | ID: mdl-2083040

ABSTRACT

Adrenaline injection fluids aged between 3 and 33 years were analyzed with respect to oxidation and racemization. The oxidation was determined by ion-pair reversed phase HPLC, and the degree of racemization was determined by derivatization of the adrenaline isomers to diastereomeric forms and subsequently separated by reversed phase HPLC. 10% adrenaline was oxidized after about 11 years, while 10% L-adrenaline was converted to D-adrenaline after only 4 years. After about 4 years, the injections contained less than 90% active adrenaline.


Subject(s)
Epinephrine/analysis , Chromatography, High Pressure Liquid , Drug Stability , Drug Storage , Epinephrine/administration & dosage , Injections, Intravenous , Isomerism , Oxidation-Reduction , Time Factors
5.
Acta Pharm Nord ; 1(1): 1-8, 1989.
Article in English | MEDLINE | ID: mdl-2597333

ABSTRACT

A gas-liquid chromatographic method for the determination of epoxidized vegetable oils (EVO), such as epoxidized soybean oil and epoxidized linseed oil, in aqueous solutions is described. The EVOs are extracted with n-hexane and transesterified to the methyl esters by sodium methoxide in methanol. 3% OV-210 is used as the stationary phase. The weakest standard solution corresponds to 5 micrograms/l (5 ppb) of EVO in an aqueous sample. The reproducibility of a single analysis is 5%. The method is used for the determination of EVO in intravenous fluids stored in flexible polyvinyl chloride bags.


Subject(s)
Plant Oils/analysis , Polyvinyl Chloride/analysis , Polyvinyls/analysis , Chromatography, Gas , Epoxy Compounds/analysis , Spectrophotometry, Infrared
6.
Acta Pharm Nord ; 1(1): 9-16, 1989.
Article in English | MEDLINE | ID: mdl-2597338

ABSTRACT

A method for the determination of di(2-ethylhexyl) phthalate (DEHP), epoxidized vegetable oils (EVO) and stearates in aqueous solutions is described. A stepwise extraction procedure is employed to separate DEHP and EVO from the stearates, using n-hexane as extraction solvent. EVO is transesterified to methyl esters by sodium methoxide in methanol. The stearates are derivatized by methanol containing sulfuric acid. The alkyl esters are analyzed by gas-liquid chromatography, using 3% OV-210 as the stationary phase. The concentrations of the weakest standard solutions correspond to 10, 5 and 8 micrograms/l (ppb) of DEHP, EVO and stearates, respectively, in the aqueous samples. The method is used for the determination of DEHP, EVO and stearates in intravenous solutions stored in flexible polyvinyl chloride bags.


Subject(s)
Diethylhexyl Phthalate/analysis , Phthalic Acids/analysis , Plant Oils/analysis , Polyvinyl Chloride/analysis , Polyvinyls/analysis , Stearates/analysis , Stearic Acids/analysis , Chromatography, Gas
7.
Acta Pharm Nord ; 1(6): 313-20, 1989.
Article in English | MEDLINE | ID: mdl-2624701

ABSTRACT

The concentration of epoxidized vegetable oils (EVO) and di(2-ethylhexyl) phthalate (DEHP) in infusion fluids in soft polyvinyl chloride (PVC) bags has been determined by gas-liquid chromatography prior to and after agitation. Normal saline, isotonic glucose and Ringer acetate from four different manufacturers were investigated. Agitation resulted in an increased concentration of EVO and DEHP. Significant differences in contamination level were observed between solutions of different compositions and in synonymous preparations from different manufacturers. The results indicated that the total amount of migrating EVO and DEHP was affected by the pH of the solution and by the age of the plastic material. It is suggested that the migration of EVO and DEHP during agitation is influenced by the concentration of plastic degradation products.


Subject(s)
Diethylhexyl Phthalate/analysis , Drug Contamination , Infusions, Intravenous/instrumentation , Phthalic Acids/analysis , Plant Oils/analysis , Polyvinyl Chloride/analysis , Polyvinyls/analysis , Chemistry, Pharmaceutical
8.
Acta Pharm Nord ; 1(6): 321-6, 1989.
Article in English | MEDLINE | ID: mdl-2624702

ABSTRACT

The influence of mono(2-ethylhexyl) phthalate (MEHP) and stearates on the migration of di(2-ethylhexyl) phthalate (DEHP) and epoxidized vegetable oils (EVO) in soft polyvinyl chloride infusion fluid bags during agitation has been investigated by gas-liquid chromatography. Normal saline, isotonic glucose and Ringer acetate from 3 different manufacturers were investigated. A covariation was observed between the MEHP concentration in the solution and the pH. The MEHP concentration was not influenced by agitation. There was no correlation between the MEHP concentration in the solution and the migration of EVO and DEHP, or between the stearate concentration and the EVO and DEHP migration.


Subject(s)
Diethylhexyl Phthalate/analysis , Infusions, Intravenous/instrumentation , Phthalic Acids/analysis , Polyvinyl Chloride/analysis , Polyvinyls/analysis , Stearates/analysis , Stearic Acids/analysis , Chemistry, Pharmaceutical , Plant Oils/analysis
9.
Acta Pharm Nord ; 1(5): 287-90, 1989.
Article in English | MEDLINE | ID: mdl-2610904

ABSTRACT

Samples of soft polyvinyl chloride (PVC) fluid bags containing normal saline and glucose 50 mg/ml were analyzed for plastic additives. The bags were shaken for 24 hours before analysis. The PVC plastic materials contained di(2-ethylhexyl)phthalate, epoxidized vegetable oils and stearates as the main additives. The same components were found in the solutions. Mono(2-ethylhexyl)phthalate was detected only in the solutions.


Subject(s)
Plastics/analysis , Polyvinyl Chloride/analysis , Polyvinyls/analysis , Diethylhexyl Phthalate/analysis , Drug Packaging , Glucose/analysis , Infusions, Intravenous , Sodium Chloride/analysis , Solutions
SELECTION OF CITATIONS
SEARCH DETAIL
...