1.
Front Med (Lausanne) ; 10: 1157486, 2023.
Article in English | MEDLINE | ID: mdl-37138745

ABSTRACT

Objective: To introduce a novel technology currently under final development before regulatory approvals for the furtherment of cataract surgery, using the FemtoMatrix® laser system, and to demonstrate its safety and efficacy as compared to standard ultrasound phacoemulsification. Methods: Thirty-three patients with bilateral cataracts were operated on with one eye undergoing PhotoEmulsification® treatment on the FemtoMatrix® device and the contralateral eye receiving the control procedure, i.e., standard ultrasound phacoemulsification treatment. The number of "zero-phaco" procedures (denoting that I/A alone was sufficient to aspirate the lens fragments and that no ultrasound energy was needed) was recorded and Effective Phaco Time (EPT) values were compared. The patient follow-up was 3 months. Results: Thirty-three eyes from a population with a mean cataract grade of 2.6 were treated on the FemtoMatrix®, of which 29 were "zero-phaco" (88%). All patients were operated on by a single surgeon who was a relative novice to the technology (63 patients treated prior to this study). Conversely, of the 33 fellow eyes who underwent standard ultrasound phacoemulsification, none were zero-phaco (0%) - all required varying degrees of ultrasound energy to make lens aspiration possible. The mean EPT was significantly lower in the PhotoEmulsification® laser group (0.2 ± 0.8 s) than in the phaco group (1.3 ± 1.2 s) (p < 0.0001). The safety profiles of the two procedures were comparable, with no device-related adverse events noted. Conclusion: FemtoMatrix® is a promising femtosecond laser platform that, when compared to phacoemulsification, significantly decreases or eliminates EPT altogether. The system is used to perform PhotoEmulsification®, making zero-phaco cataract procedures feasible including in high-grade cataracts (>3). It enables personalized treatment by automatically measuring and adapting the laser energy required to obtain the most efficient cutting of the crystalline lens. This new technology appears to be safe and effective in cataract surgery.

2.
Open Vet J ; 8(3): 305-312, 2018.
Article in English | MEDLINE | ID: mdl-30148082

ABSTRACT

The objective was to assess the effect of high intensity focused ultrasound (HIFU) on intraocular pressure (IOP) in dogs with primary glaucoma (PG). Seven dogs (13 eyes) presenting with PG as diagnosed by a raised IOP (> 20 mm Hg) associated with consistent gonioscopy and ultrasound biomicroscopy of the ciliary cleft, with no other ocular disease. Patients were divided into 3 groups, corresponding to their pre-operative IOP (group 1 ranging from 21 to 30 mm Hg, group 2 from 31 to 40 and group 3 for 40 and above). Ciliary process sonication was achieved with a probe containing one high-frequency transducer operating at 21 MHz during 5 seconds. Six sites were treated in patients from group 1, 8 in group 2, 10 in group 3, under general anesthesia. Post-operative treatment consisted of systemic meloxicam and topical carbonic anhydrase inhibitors, beta-blockers and prostaglandins analogues. No intraoperative complications were observed. Conjunctival hyperaemia occurred in eyes from group 2 (66%) and 3 (100%). Conjunctival burns were visible in 2 patients from group 3. One patient from group 3 experienced a hypertensive spike during the first hours post-op with associated pain. The hypotensive effect of HIFU was observed in all groups. Normotensive IOP (≤20 mm Hg) was reached in all patients until the last recheck at 6 months post op. Despite the small number of patients included in the study, HIFU appears to be a promising option for the management of PG in dogs.

3.
Ultrasound Med Biol ; 40(9): 2096-106, 2014 Sep.
Article in English | MEDLINE | ID: mdl-24996576

ABSTRACT

Several physical methods can be used to coagulate the ciliary body and decrease intra-ocular pressure in patients with glaucoma. The study described here investigated the short- and long-term effects of high-intensity focused ultrasound (HIFU) cyclocoagulation on the aqueous humor production structures and outflow pathways. Thirty-four rabbit eyes were sonicated with a ring-shaped probe containing six miniaturized HIFU transducers. Light, scanning electron and transmission electron microscopy and corrosion casts were performed. In the affected regions, the epithelium of the ciliary processes was degenerated or necrotic and sloughed off. Examinations performed several months afterward revealed involution of the ciliary processes. Vascular corrosion cast revealed focal interruption of the ciliary body microvasculature. In most animals, a sustained fluid space was seen between the sclera, the ciliary body and the choroid, likely indicating an increase in the aqueous outflow by the uveoscleral pathway. These results suggest that HIFU cyclocoagulation has a dual effect on aqueous humor dynamics.


Subject(s)
Aqueous Humor/diagnostic imaging , Ciliary Body/diagnostic imaging , High-Intensity Focused Ultrasound Ablation/methods , Animals , Female , Follow-Up Studies , Microscopy, Electron, Scanning/methods , Microscopy, Electron, Scanning Transmission/methods , Models, Animal , Rabbits , Ultrasonography
4.
Ultrasound Med Biol ; 40(6): 1216-27, 2014 Jun.
Article in English | MEDLINE | ID: mdl-24613634

ABSTRACT

In ocular drug delivery, the sclera is a promising pathway for administering drugs to both the anterior and posterior segments of the eye. Due to the low permeability of the sclera, however, efficient drug delivery is challenging. In this study, pulsed ultrasound (US) was investigated as a potential method for enhancing drug delivery to the eye through the sclera. The permeability of rabbit scleral tissue to a model drug compound, sodium fluorescein, was measured after US-irradiation at 1.1 MHz using time-averaged acoustic powers of 0.5-5.4 W (6.8-12.8 MPa peak negative pressure), with a fixed duty cycle of 2.5% for two different pulse repetition frequencies of 100 and 1000 Hz. Acoustic cavitation activity was measured during exposures using a passive cavitation detector and was used to quantify the level of bubble activity. A correlation between the amount of cavitation activity and the enhancement of scleral permeability was demonstrated with a significant enhancement in permeability of US exposed samples compared to controls. Transmission electron microscopy showed no evidence of significant alteration in viability of tissue exposed to US exposures. A pulsed US protocol designed to maximum cavitation activity may therefore be a viable method for enhancing drug delivery to the eye.


Subject(s)
Drug Delivery Systems , Fluorescein/pharmacokinetics , Sclera , Sonication/methods , Animals , In Vitro Techniques , Rabbits
5.
Invest Ophthalmol Vis Sci ; 52(12): 8747-53, 2011 Nov 11.
Article in English | MEDLINE | ID: mdl-21948551

ABSTRACT

PURPOSE: To evaluate the relative safety and potential efficacy of high-intensity focused ultrasound cyclocoagulation by a miniaturized annular device containing six piezoceramic transducers in patients with refractory glaucoma. METHODS: This was a three-center prospective interventional pilot study. Twelve eyes of 12 patients with refractory glaucoma were insonified using a ring-shaped probe containing six miniaturized high-frequency transducers operating at 21 MHz. Ultrasound biomicroscopy (UBM) and a complete ophthalmic examination were performed before the procedure and at 1 day, 1 week, 1 month, and 3 months after the procedure. Additional visits were performed 6 and 12 months after the procedure. RESULTS: Intraocular pressure was significantly reduced (P < 0.01) from a mean preoperative value of 37.9 ± 10.7 mm Hg to a mean postoperative value of 27.3 ± 12.4, 25.2 ± 11.3, 25.2 ± 7.7, 24.8 ± 9.8, and 26.3 ± 5.1 mm Hg at 1 day, 1 week, 1 month, 3 months, and 6 months, respectively, and to a mean value of 24.7 ± 8.5 at the last follow-up visit. No major intraoperative or postoperative complications occurred. Minor postoperative corneal complications developed in four patients with previous corneal abnormalities: superficial punctate keratitis (n = 3) and central superficial corneal ulceration (n = 1). UBM showed cystic involution of the ciliary body in 9 of the 12 eyes and a suprachoroidal fluid space in 8 of the 12 eyes. CONCLUSIONS: Ultrasonic circular cyclocoagulation using high-intensity focused ultrasound delivered by a circular miniaturized device containing six piezoceramic transducers seems to be an effective and well-tolerated method to reduce intraocular pressure in patients with refractory glaucoma.


Subject(s)
Glaucoma/diagnostic imaging , Glaucoma/therapy , Microscopy, Acoustic/instrumentation , Miniaturization/methods , Ultrasonic Therapy/instrumentation , Adult , Aged , Aged, 80 and over , Ciliary Body/blood supply , Ciliary Body/diagnostic imaging , Female , Follow-Up Studies , Humans , Intraocular Pressure , Male , Microscopy, Acoustic/adverse effects , Microscopy, Acoustic/methods , Middle Aged , Pilot Projects , Transducers , Treatment Outcome , Ultrasonic Therapy/adverse effects , Ultrasonic Therapy/methods
6.
Ultrasound Med Biol ; 37(5): 742-54, 2011 May.
Article in English | MEDLINE | ID: mdl-21439719

ABSTRACT

This study examined the feasibility of high-intensity focused ultrasound (HIFU) for glaucoma treatment with conformal coagulation of the ciliary bodies (CB). A miniaturized high frequency (21 MHz) device was developed, based on the geometry of the eye and adapted to the anatomy of the rabbit eyeball. Six line-focus lesions were distributed along a circle and produced by six cylindrical transducers. To be conformal, the numerical model predicted an intensity of 6.9 W/cm(2), with exposure duration of 3 s ON (powered per sector). In vivo experiments were conducted on two rabbits. A significant intraocular pressure reduction was noted (-45% and -31%). Histology demonstrated conformal and homogeneous coagulation of the CB without side effects.


Subject(s)
Ciliary Body/diagnostic imaging , Glaucoma/diagnostic imaging , Glaucoma/therapy , Ultrasonic Therapy/instrumentation , Animals , Computer Simulation , Disease Models, Animal , Miniaturization/methods , Rabbits , Ultrasonography