1.
J Imaging ; 8(6)2022 May 24.
Article in English | MEDLINE | ID: mdl-35735949

ABSTRACT

The potential of any multi-analytical and non-invasive approach to the study of cultural heritage, both for conservation and scientific investigation purposes, is gaining increasing interest, and it was tested in this paper, focusing on the panel painting Madonna della Tenda (Musei Reali, Turin), identified as a 16th-century copy of the painting by Raffaello Sanzio. As a part of a broader diagnostic campaign carried out at the Centro Conservazione e Restauro, La Venaria Reale in Turin, Italy, the potential of the combination of X-ray radiography, pulse-compression thermography, macro X-ray fluorescence, and IR reflectography was tested to investigate the wooden support and all the preparatory phases for the realization of the painting. The results of the optical microscopy and SEM/EDS analyses on a multi-layered micro-sample were used for a precise comparison, integration, and/or confirmation of what was suggested by the non-invasive techniques. Particularly, the radiographic and thermographic techniques allowed for an in-depth study of a hole, interestingly present on the panel's back surface, detecting the trajectory of the wood grain and confirming the presence of an old wood knot, as well as of a tau-shaped element-potentially a cracked and unfilled area of the wooden support-near the hollow. The combination of radiography, macro X-ray fluorescence, Near Infrared (NIR), and Short Wave Infrared (SWIR) reflectography allowed for an inspection of the ground layer, imprimitura, engravings, and underdrawing, not only revealing interesting technical-executive aspects of the artwork realization, but also highlighting the advantages of an integrated reading of data obtained from the different analytical techniques.

2.
Anal Chem ; 88(20): 9873-9880, 2016 Oct 18.
Article in English | MEDLINE | ID: mdl-27656755

ABSTRACT

A full field-X-ray camera (FF-XRC) was developed for performing the simultaneous mapping of chemical elements with a high lateral resolution. The device is based on a conventional CCD detector coupled to a straight shaped polycapillary. Samples are illuminated at once with a broad primary beam that can consist of X-rays or charged particles in two different analytical setups. The characteristic photons induced in the samples are guided by the polycapillary to the detector allowing the elemental imaging without the need for scanning. A single photon counting detection operated in a multiframe acquisition mode and a processing algorithm developed for event hitting reconstruction have enabled one to use the CCD as a high energy resolution X-ray detector. A novel software with a graphical user interface (GUI) programmed in Matlab allows full control of the device and the real-time imaging with a region-of-interest (ROI) method. At the end of the measurement, the software produces spectra for each of the pixels in the detector allowing the application of a least-squares fitting with external analytical tools. The FF-XRC is very compact and can be installed in different experimental setups. This work shows the potentialities of the instrument in both a full field-micro X-ray fluorescence (FF-MXRF) tabletop device and in a full field-micro particle induced X-ray emission (FF-MPIXE) end-station operated with an external proton beam. Some examples of applications are given as well.

3.
Rev Sci Instrum ; 87(2): 02A510, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26931918

ABSTRACT

An experimental campaign aiming to investigate electron cyclotron resonance (ECR) plasma X-ray emission has been recently carried out at the ECRISs-Electron Cyclotron Resonance Ion Sources laboratory of Atomki based on a collaboration between the Debrecen and Catania ECR teams. In a first series, the X-ray spectroscopy was performed through silicon drift detectors and high purity germanium detectors, characterizing the volumetric plasma emission. The on-purpose developed collimation system was suitable for direct plasma density evaluation, performed "on-line" during beam extraction and charge state distribution characterization. A campaign for correlating the plasma density and temperature with the output charge states and the beam intensity for different pumping wave frequencies, different magnetic field profiles, and single-gas/gas-mixing configurations was carried out. The results reveal a surprisingly very good agreement between warm-electron density fluctuations, output beam currents, and the calculated electromagnetic modal density of the plasma chamber. A charge-coupled device camera coupled to a small pin-hole allowing X-ray imaging was installed and numerous X-ray photos were taken in order to study the peculiarities of the ECRIS plasma structure.

4.
Anal Chem ; 86(21): 10892-9, 2014 Nov 04.
Article in English | MEDLINE | ID: mdl-25284509

ABSTRACT

This work describes a tabletop (50 cm × 25 cm × 25 cm) full field X-ray pinhole camera (FF-XPC) presenting high energy- and high spatial-resolution. The FF-XPC consists of a conventional charge-coupled device (CCD) detector coupled, in a coaxial geometry, to a pinhole collimator of small diameter. The X-ray fluorescence (XRF) is induced on the samples with an external low-power X-ray tube. The use of the CCD as an energy dispersive X-ray detector was obtained by adopting a multi-image acquisition in single photon counting and by developing a processing algorithm to be applied in real-time to each of the acquired image-frames. This approach allowed the measurement of X-ray spectra with an energy resolution down to 133 eV at the reference value of 5.9 keV. The detection of the X-ray fluorescence through the pinhole-collimator allowed the two-dimensional elemental mapping of the irradiated samples. Two magnifications (M), determined by the relative sample-pinhole-CCD distances, are used in the present setup. A low value of M (equal to 0.35×) allows the macro-FF-XRF of large area samples (up to 4 × 4 cm(2)) with a spatial resolution down to 140 µm; a large magnification (M equal to 6×) is used for the micro-FF-XRF of small area samples (2.5 × 2.5 mm(2)) with a spatial resolution down to 30 µm.

5.
Ann Chim ; 93(11): 863-71, 2003 Nov.
Article in English | MEDLINE | ID: mdl-14703855

ABSTRACT

Just two examples of writings by the hand of S. Francesco are known to exist: a letter to Brother Leone, kept in the archives of Spoleto cathedral and the Chartula, displayed in the Hall of Reliquaries at Assisi's Sacro Convento. For the first time in its history the Chartula has undergone a series of non-destructive analyses, with the object of establishing its current state of conservation and the types of inks used in its making. A new display case has been designed and built for the improved conservation of this precious document. The new housing substitutes an ancient case, which was located inside the original reliquary.


Subject(s)
Handwriting , Ink , Famous Persons , History, Medieval , Humans , Optics and Photonics , Religion/history , Saints/history , Spectrum Analysis