Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 16 de 16
Filter
1.
Phys Med Biol ; 60(7): 2955-79, 2015 Apr 07.
Article in English | MEDLINE | ID: mdl-25789937

ABSTRACT

This article considers the treatment plan optimization problem for Volumetric Modulated Arc Therapy (VMAT) with constant gantry speed and dose rate (VMATc). In particular, we consider the simultaneous optimization of multi-leaf collimator leaf positions and a constant gantry speed and dose rate. We propose a heuristic framework for (approximately) solving this optimization problem that is based on hierarchical decomposition. Specifically, an iterative algorithm is used to heuristically optimize dose rate and gantry speed selection, where at every iteration a leaf position optimization subproblem is solved, also heuristically, to find a high-quality plan corresponding to a given dose rate and gantry speed. We apply our framework to clinical patient cases, and compare the resulting VMATc plans to idealized IMRT, as well as full VMAT plans. Our results suggest that VMATc is capable of producing treatment plans of comparable quality to VMAT, albeit at the expense of long computation time and generally higher total monitor units.


Subject(s)
Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Algorithms , Computer Simulation , Head and Neck Neoplasms/radiotherapy , Humans , Male , Prostatic Neoplasms/radiotherapy , Reproducibility of Results
2.
Med Phys ; 41(6): 061711, 2014 Jun.
Article in English | MEDLINE | ID: mdl-24877806

ABSTRACT

PURPOSE: To develop a novel algorithm that incorporates prior treatment knowledge into intensity modulated radiation therapy optimization to facilitate automatic treatment planning and adaptive radiotherapy (ART) replanning. METHODS: The algorithm automatically creates a treatment plan guided by the DVH curves of a reference plan that contains information on the clinician-approved dose-volume trade-offs among different targets/organs and among different portions of a DVH curve for an organ. In ART, the reference plan is the initial plan for the same patient, while for automatic treatment planning the reference plan is selected from a library of clinically approved and delivered plans of previously treated patients with similar medical conditions and geometry. The proposed algorithm employs a voxel-based optimization model and navigates the large voxel-based Pareto surface. The voxel weights are iteratively adjusted to approach a plan that is similar to the reference plan in terms of the DVHs. If the reference plan is feasible but not Pareto optimal, the algorithm generates a Pareto optimal plan with the DVHs better than the reference ones. If the reference plan is too restricting for the new geometry, the algorithm generates a Pareto plan with DVHs close to the reference ones. In both cases, the new plans have similar DVH trade-offs as the reference plans. RESULTS: The algorithm was tested using three patient cases and found to be able to automatically adjust the voxel-weighting factors in order to generate a Pareto plan with similar DVH trade-offs as the reference plan. The algorithm has also been implemented on a GPU for high efficiency. CONCLUSIONS: A novel prior-knowledge-based optimization algorithm has been developed that automatically adjust the voxel weights and generate a clinical optimal plan at high efficiency. It is found that the new algorithm can significantly improve the plan quality and planning efficiency in ART replanning and automatic treatment planning.


Subject(s)
Algorithms , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Electronic Data Processing , Head and Neck Neoplasms/drug therapy , Humans , Male , Prostatic Neoplasms/radiotherapy , Radiotherapy Dosage , Retreatment/methods
3.
Med Phys ; 40(7): 071713, 2013 Jul.
Article in English | MEDLINE | ID: mdl-23822417

ABSTRACT

PURPOSE: To introduce a hybrid volumetric modulated arc therapy/intensity modulated radiation therapy (VMAT/IMRT) optimization strategy called FusionArc that combines the delivery efficiency of single-arc VMAT with the potentially desirable intensity modulation possible with IMRT. METHODS: A beamlet-based inverse planning system was enhanced to combine the advantages of VMAT and IMRT into one comprehensive technique. In the hybrid strategy, baseline single-arc VMAT plans are optimized and then the current cost function gradients with respect to the beamlets are used to define a metric for predicting which beam angles would benefit from further intensity modulation. Beams with the highest metric values (called the gradient factor) are converted from VMAT apertures to IMRT fluence, and the optimization proceeds with the mixed variable set until convergence or until additional beams are selected for conversion. One phantom and two clinical cases were used to validate the gradient factor and characterize the FusionArc strategy. Comparisons were made between standard IMRT, single-arc VMAT, and FusionArc plans with one to five IMRT∕hybrid beams. RESULTS: The gradient factor was found to be highly predictive of the VMAT angles that would benefit plan quality the most from beam modulation. Over the three cases studied, a FusionArc plan with three converted beams achieved superior dosimetric quality with reductions in final cost ranging from 26.4% to 48.1% compared to single-arc VMAT. Additionally, the three beam FusionArc plans required 22.4%-43.7% fewer MU∕Gy than a seven beam IMRT plan. While the FusionArc plans with five converted beams offer larger reductions in final cost--32.9%-55.2% compared to single-arc VMAT--the decrease in MU∕Gy compared to IMRT was noticeably smaller at 12.2%-18.5%, when compared to IMRT. CONCLUSIONS: A hybrid VMAT∕IMRT strategy was implemented to find a high quality compromise between gantry-angle and intensity-based degrees of freedom. This optimization method will allow patients to be simultaneously planned for dosimetric quality and delivery efficiency without switching between delivery techniques. Example phantom and clinical cases suggest that the conversion of only three VMAT segments to modulated beams may result in a good combination of quality and efficiency.


Subject(s)
Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Humans , Male , Pancreatic Neoplasms/radiotherapy , Phantoms, Imaging , Prostatic Neoplasms/radiotherapy
4.
Phys Med Biol ; 57(14): 4569-88, 2012 Jul 21.
Article in English | MEDLINE | ID: mdl-22722760

ABSTRACT

We study the treatment plan optimization problem for volumetric modulated arc therapy (VMAT). We propose a new column-generation-based algorithm that takes into account bounds on the gantry speed and dose rate, as well as an upper bound on the rate of change of the gantry speed, in addition to MLC constraints. The algorithm iteratively adds one aperture at each control point along the treatment arc. In each iteration, a restricted problem optimizing intensities at previously selected apertures is solved, and its solution is used to formulate a pricing problem, which selects an aperture at another control point that is compatible with previously selected apertures and leads to the largest rate of improvement in the objective function value of the restricted problem. Once a complete set of apertures is obtained, their intensities are optimized and the gantry speeds and dose rates are adjusted to minimize treatment time while satisfying all machine restrictions. Comparisons of treatment plans obtained by our algorithm to idealized IMRT plans of 177 beams on five clinical prostate cancer cases demonstrate high quality with respect to clinical dose-volume criteria. For all cases, our algorithm yields treatment plans that can be delivered in around 2 min. Implementation on a graphic processing unit enables us to finish the optimization of a VMAT plan in 25-55 s.


Subject(s)
Algorithms , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Benchmarking , Computer Graphics , Computers
5.
Med Phys ; 38(3): 1266-79, 2011 Mar.
Article in English | MEDLINE | ID: mdl-21520839

ABSTRACT

PURPOSE: Traditionally, the tongue-and-groove effect due to the multileaf collimator architecture in intensity-modulated radiation therapy (IMRT) has typically been deferred to the leaf sequencing stage. The authors propose a new direct aperture optimization method for IMRT treatment planning that explicitly incorporates dose calculation inaccuracies due to the tongue-and-groove effect into the treatment plan optimization stage. METHODS: The authors avoid having to accurately estimate the dosimetric effects of the tongue-and-groove architecture by using lower and upper bounds on the dose distribution delivered to the patient. They then develop a model that yields a treatment plan that is robust with respect to the corresponding dose calculation inaccuracies. RESULTS: Tests on a set of ten clinical head-and-neck cancer cases demonstrate the effectiveness of the new method in developing robust treatment plans with tight dose distributions in targets and critical structures. This is contrasted with the very loose bounds on the dose distribution that are obtained by solving a traditional treatment plan optimization model that ignores tongue-and-groove effects in the treatment planning stage. CONCLUSIONS: A robust direct aperture optimization approach is proposed to account for the dosimetric inaccuracies caused by the tongue-and-groove effect. The experiments validate the ability of the proposed approach in designing robust treatment plans regardless of the exact consequences of the tongue-and-groove architecture.


Subject(s)
Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Algorithms , Head and Neck Neoplasms/radiotherapy , Humans , Radiotherapy Dosage
6.
Med Phys ; 37(11): 5787-91, 2010 Nov.
Article in English | MEDLINE | ID: mdl-21158290

ABSTRACT

PURPOSE: To develop a novel aperture-based algorithm for volumetric modulated are therapy (VMAT) treatment plan optimization with high quality and high efficiency. METHODS: The VMAT optimization problem is formulated as a large-scale convex programming problem solved by a column generation approach. The authors consider a cost function consisting two terms, the first enforcing a desired dose distribution and the second guaranteeing a smooth dose rate variation between successive gantry angles. A gantry rotation is discretized into 180 beam angles and for each beam angle, only one MLC aperture is allowed. The apertures are generated one by one in a sequential way. At each iteration of the column generation method, a deliverable MLC aperture is generated for one of the unoccupied beam angles by solving a subproblem with the consideration of MLC mechanic constraints. A subsequent master problem is then solved to determine the dose rate at all currently generated apertures by minimizing the cost function. When all 180 beam angles are occupied, the optimization completes, yielding a set of deliverable apertures and associated dose rates that produce a high quality plan. RESULTS: The algorithm was preliminarily tested on five prostate and five head-and-neck clinical cases, each with one full gantry rotation without any couch/collimator rotations. High quality VMAT plans have been generated for all ten cases with extremely high efficiency. It takes only 5-8 min on CPU (MATLAB code on an Intel Xeon 2.27 GHz CPU) and 18-31 s on GPU (CUDA code on an NVIDIA Tesla C1060 GPU card) to generate such plans. CONCLUSIONS: The authors have developed an aperture-based VMAT optimization algorithm which can generate clinically deliverable high quality treatment plans at very high efficiency.


Subject(s)
Head and Neck Neoplasms/radiotherapy , Prostatic Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods , Algorithms , Computer Graphics , Computer Simulation , Computers , Dose-Response Relationship, Radiation , Humans , Male , Models, Statistical , Radiotherapy Dosage , Reproducibility of Results , Time Factors
7.
Phys Med Biol ; 55(18): 5467-82, 2010 Sep 21.
Article in English | MEDLINE | ID: mdl-20798458

ABSTRACT

One of the most widely studied problems of the intensity-modulated radiation therapy (IMRT) treatment planning problem is the fluence map optimization (FMO) problem, the problem of determining the amount of radiation intensity, or fluence, of each beamlet in each beam. For a given set of beams, the fluences of the beamlets can drastically affect the quality of the treatment plan, and thus it is critical to obtain good fluence maps for radiation delivery. Although several approaches have been shown to yield good solutions to the FMO problem, these solutions are not guaranteed to be optimal. This shortcoming can be attributed to either optimization model complexity or properties of the algorithms used to solve the optimization model. We present a convex FMO formulation and an interior point algorithm that yields an optimal treatment plan in seconds, making it a viable option for clinical applications.


Subject(s)
Algorithms , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Humans , Radiotherapy Dosage
8.
Phys Med Biol ; 53(12): 3175-88, 2008 Jun 21.
Article in English | MEDLINE | ID: mdl-18506074

ABSTRACT

In this study, we perform a scientific comparative analysis of using (60)Co beams in intensity-modulated radiation therapy (IMRT). In particular, we evaluate the treatment plan quality obtained with (i) 6 MV, 18 MV and (60)Co IMRT; (ii) different numbers of static multileaf collimator (MLC) delivered (60)Co beams and (iii) a helical tomotherapy (60)Co beam geometry. We employ a convex fluence map optimization (FMO) model, which allows for the comparison of plan quality between different beam energies and configurations for a given case. A total of 25 clinical patient cases that each contain volumetric CT studies, primary and secondary delineated targets, and contoured structures were studied: 5 head-and-neck (H&N), 5 prostate, 5 central nervous system (CNS), 5 breast and 5 lung cases. The DICOM plan data were anonymized and exported to the University of Florida optimized radiation therapy (UFORT) treatment planning system. The FMO problem was solved for each case for 5-71 equidistant beams as well as a helical geometry for H&N, prostate, CNS and lung cases, and for 3-7 equidistant beams in the upper hemisphere for breast cases, all with 6 MV, 18 MV and (60)Co dose models. In all cases, 95% of the target volumes received at least the prescribed dose with clinical sparing criteria for critical organs being met for all structures that were not wholly or partially contained within the target volume. Improvements in critical organ sparing were found with an increasing number of equidistant (60)Co beams, yet were marginal above 9 beams for H&N, prostate, CNS and lung. Breast cases produced similar plans for 3-7 beams. A helical (60)Co beam geometry achieved similar plan quality as static plans with 11 equidistant (60)Co beams. Furthermore, 18 MV plans were initially found not to provide the same target coverage as 6 MV and (60)Co plans; however, adjusting the trade-offs in the optimization model allowed equivalent target coverage for 18 MV. For plans with comparable target coverage, critical structure sparing was best achieved with 6 MV beams followed closely by (60)Co beams, with 18 MV beams requiring significantly increased dose to critical structures. In this paper, we report in detail on a representative set of results from these experiments. The results of the investigation demonstrate the potential for IMRT radiotherapy employing commercially available (60)Co sources and a double-focused MLC. Increasing the number of equidistant beams beyond 9 was not observed to significantly improve target coverage or critical organ sparing and static plans were found to produce comparable plans to those obtained using a helical tomotherapy treatment delivery when optimized using the same well-tuned convex FMO model. While previous studies have shown that 18 MV plans are equivalent to 6 MV for prostate IMRT, we found that the 18 MV beams actually required more fluence to provide similar quality target coverage.


Subject(s)
Cobalt Radioisotopes/therapeutic use , Radiotherapy, Intensity-Modulated/methods , Breast Neoplasms/radiotherapy , Central Nervous System/pathology , Central Nervous System/radiation effects , Head and Neck Neoplasms/radiotherapy , Humans , Male , Prostatic Neoplasms/radiotherapy , Radiotherapy, High-Energy
9.
Med Phys ; 35(3): 1103-12, 2008 Mar.
Article in English | MEDLINE | ID: mdl-18404945

ABSTRACT

The authors present a comparative study of intensity modulated proton therapy (IMPT) treatment planning employing algorithms of three-dimensional (3D) modulation, and 2.5-dimensional (2.5D) modulation, and intensity modulated distal edge tracking (DET) [A. Lomax, Phys. Med. Biol. 44, 185-205 (1999)] applied to the treatment of head-and-neck cancer radiotherapy. These three approaches were also compared with 6 MV photon intensity modulated radiation therapy (IMRT). All algorithms were implemented in the University of Florida Optimized Radiation Therapy system using a finite sized pencil beam dose model and a convex fluence map optimization model. The 3D IMPT and the DET algorithms showed considerable advantages over the photon IMRT in terms of dose conformity and sparing of organs at risk when the beam number was not constrained. The 2.5D algorithm did not show an advantage over the photon IMRT except in the dose reduction to the distant healthy tissues, which is inherent in proton beam delivery. The influences of proton beam number and pencil beam size on the IMPT plan quality were also studied. Out of 24 cases studied, three cases could be adequately planned with one beam and 12 cases could be adequately planned with two beams, but the dose uniformity was often marginally acceptable. Adding one or two more beams in each case dramatically improved the dose uniformity. The finite pencil beam size had more influence on the plan quality of the 2.5D and DET algorithms than that of the 3D IMPT. To obtain a satisfactory plan quality, a 0.5 cm pencil beam size was required for the 3D IMPT and a 0.3 cm size was required for the 2.5D and the DET algorithms. Delivery of the IMPT plans produced in this study would require a proton beam spot scanning technique that has yet to be developed clinically.


Subject(s)
Algorithms , Proton Therapy , Radiotherapy, Intensity-Modulated/methods , Head/radiation effects , Humans , Neck/radiation effects , Radiotherapy Planning, Computer-Assisted
10.
Int J Radiat Oncol Biol Phys ; 71(3): 880-9, 2008 Jul 01.
Article in English | MEDLINE | ID: mdl-18440728

ABSTRACT

PURPOSE: To propose a new measure of target underdose that can be used in the evaluation and optimization of radiotherapy dose distributions. METHODS AND MATERIALS: We compare various formulations of the equivalent uniform dose (EUD) and introduce a modification of existing EUD definitions, which we call tail EUD. Tail EUD is a measure of "cold spots" below the prescription dose in the target dose distribution, using units of gray (Gy). We investigate the mathematical properties of various target EUD concepts, including tail EUD. We apply the tail EUD measure retrospectively to intensity modulated radiation therapy (IMRT) treatment plans from our plan database. We also use tail EUD as an optimization objective in the optimization of prostate, pancreas, and head-and-neck plans. RESULTS: Tail EUD has desirable mathematical properties. In particular, it is convex and it leads to convex level sets (i.e., no local minima) if the EUD from which it is derived is concave. The tail EUD value is correlated with the subjective degree of target coverage. Constraining tail EUDs to a certain level in plan optimization leads to comparable target coverage in different plans and treatment sites. CONCLUSIONS: The newly introduced concept of tail EUD appears to be useful for both plan evaluation and optimization. In addition it can potentially be applied in the design of new clinical protocols.


Subject(s)
Algorithms , Models, Biological , Radiometry/methods , Radiotherapy Planning, Computer-Assisted/methods , Computer Simulation , Humans , Radiotherapy Dosage , Reproducibility of Results , Sensitivity and Specificity
11.
Phys Med Biol ; 52(24): 7333-52, 2007 Dec 21.
Article in English | MEDLINE | ID: mdl-18065842

ABSTRACT

We consider the problem of intensity-modulated radiation therapy (IMRT) treatment planning using direct aperture optimization. While this problem has been relatively well studied in recent years, most approaches employ a heuristic approach to the generation of apertures. In contrast, we use an exact approach that explicitly formulates the fluence map optimization (FMO) problem as a convex optimization problem in terms of all multileaf collimator (MLC) deliverable apertures and their associated intensities. However, the number of deliverable apertures, and therefore the number of decision variables and constraints in the new problem formulation, is typically enormous. To overcome this, we use an iterative approach that employs a subproblem whose optimal solution either provides a suitable aperture to add to a given pool of allowable apertures or concludes that the current solution is optimal. We are able to handle standard consecutiveness, interdigitation and connectedness constraints that may be imposed by the particular MLC system used, as well as jaws-only delivery. Our approach has the additional advantage that it can explicitly account for transmission of dose through the part of an aperture that is blocked by the MLC system, yielding a more precise assessment of the treatment plan than what is possible using a traditional beamlet-based FMO problem. Finally, we develop and test two stopping rules that can be used to identify treatment plans of high clinical quality that are deliverable very efficiently. Tests on clinical head-and-neck cancer cases showed the efficacy of our approach, yielding treatment plans comparable in quality to plans obtained by the traditional method with a reduction of more than 75% in the number of apertures and a reduction of more than 50% in beam-on time, with only a modest increase in computational effort. The results also show that delivery efficiency is very insensitive to the addition of traditional MLC constraints; however, jaws-only treatment requires about a doubling in beam-on time and number of apertures used. Finally, we showed the importance of accounting for transmission effects when assessing or, preferably, optimizing treatment plan quality.


Subject(s)
Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Artifacts , Clinical Protocols , Computer Simulation , Dose-Response Relationship, Radiation , Head and Neck Neoplasms/diagnostic imaging , Humans , Numerical Analysis, Computer-Assisted , Phantoms, Imaging , Radiotherapy Dosage , Relative Biological Effectiveness , Reproducibility of Results , Sensitivity and Specificity , Ultrasonography
12.
Med Phys ; 33(9): 3508-18, 2006 Sep.
Article in English | MEDLINE | ID: mdl-17022247

ABSTRACT

We developed an analytical method for determining the maximum acceptable grid size for discrete dose calculation in proton therapy treatment plan optimization, so that the accuracy of the optimized dose distribution is guaranteed in the phase of dose sampling and the superfluous computational work is avoided. The accuracy of dose sampling was judged by the criterion that the continuous dose distribution could be reconstructed from the discrete dose within a 2% error limit. To keep the error caused by the discrete dose sampling under a 2% limit, the dose grid size cannot exceed a maximum acceptable value. The method was based on Fourier analysis and the Shannon-Nyquist sampling theorem as an extension of our previous analysis for photon beam intensity modulated radiation therapy [J. F. Dempsey, H. E. Romeijn, J. G. Li, D. A. Low, and J. R. Palta, Med. Phys. 32, 380-388 (2005)]. The proton beam model used for the analysis was a near monoenergetic (of width about 1% the incident energy) and monodirectional infinitesimal (nonintegrated) pencil beam in water medium. By monodirection, we mean that the proton particles are in the same direction before entering the water medium and the various scattering prior to entrance to water is not taken into account. In intensity modulated proton therapy, the elementary intensity modulation entity for proton therapy is either an infinitesimal or finite sized beamlet. Since a finite sized beamlet is the superposition of infinitesimal pencil beams, the result of the maximum acceptable grid size obtained with infinitesimal pencil beam also applies to finite sized beamlet. The analytic Bragg curve function proposed by Bortfeld [T. Bortfeld, Med. Phys. 24, 2024-2033 (1997)] was employed. The lateral profile was approximated by a depth dependent Gaussian distribution. The model included the spreads of the Bragg peak and the lateral profiles due to multiple Coulomb scattering. The dependence of the maximum acceptable dose grid size on the orientation of the beam with respect to the dose grid was also investigated. The maximum acceptable dose grid size depends on the gradient of dose profile and in turn the range of proton beam. In the case that only the phantom scattering was considered and that the beam was aligned with the dose grid, grid sizes from 0.4 to 6.8 mm were required for proton beams with ranges from 2 to 30 cm for 2% error limit at the Bragg peak point. A near linear relation between the maximum acceptable grid size and beam range was observed. For this analysis model, the resolution requirement was not significantly related to the orientation of the beam with respect to the grid.


Subject(s)
Algorithms , Models, Biological , Protons , Radiometry/methods , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Computer-Assisted/methods , Computer Simulation , Finite Element Analysis , Fourier Analysis , Humans , Quality Control , Radiotherapy Dosage , Reproducibility of Results , Sample Size , Sensitivity and Specificity
13.
Med Phys ; 33(5): 1364-71, 2006 May.
Article in English | MEDLINE | ID: mdl-16752572

ABSTRACT

We present work on combining three algorithms to improve ray-tracing efficiency in radiation therapy dose computation. The three algorithms include: An improved point-in-polygon algorithm, incremental voxel ray tracing algorithm, and stereographic projection of beamlets for voxel truncation. The point-in-polygon and incremental voxel ray-tracing algorithms have been used in computer graphics and nuclear medicine applications while the stereographic projection algorithm was developed by our group. These algorithms demonstrate significant improvements over the current standard algorithms in peer reviewed literature, i.e., the polygon and voxel ray-tracing algorithms of Siddon for voxel classification (point-in-polygon testing) and dose computation, respectively, and radius testing for voxel truncation. The presented polygon ray-tracing technique was tested on 10 intensity modulated radiation therapy (IMRT) treatment planning cases that required the classification of between 0.58 and 2.0 million voxels on a 2.5 mm isotropic dose grid into 1-4 targets and 5-14 structures represented as extruded polygons (a.k.a. Siddon prisms). Incremental voxel ray tracing and voxel truncation employing virtual stereographic projection was tested on the same IMRT treatment planning cases where voxel dose was required for 230-2400 beamlets using a finite-size pencil-beam algorithm. Between a 100 and 360 fold cpu time improvement over Siddon's method was observed for the polygon ray-tracing algorithm to perform classification of voxels for target and structure membership. Between a 2.6 and 3.1 fold reduction in cpu time over current algorithms was found for the implementation of incremental ray tracing. Additionally, voxel truncation via stereographic projection was observed to be 11-25 times faster than the radial-testing beamlet extent approach and was further improved 1.7-2.0 fold through point-classification using the method of translation over the cross product technique.


Subject(s)
Algorithms , Models, Biological , Radiometry/methods , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Conformal/methods , Computer Simulation , Humans , Radiotherapy Dosage
14.
Med Phys ; 32(2): 380-8, 2005 Feb.
Article in English | MEDLINE | ID: mdl-15789583

ABSTRACT

We present a theoretical and empirical analysis of the errors associated with the spatial discretization of the dose grid employed in optimized intensity modulated radiation therapy (IMRT) treatment plans. An information theory based Fourier analysis of the accuracy of discrete representations of three-dimensional dose distributions is presented. When applied to beamlet-based IMRT dose distributions, the theory produces analytic integrals that can bound worst case aliasing errors that can occur regardless of the location and orientation of the dose grid. The predictions of this theory are compared to empirical results obtained by solving a linear-programming based fluence-map optimization model to global optimality. A reasonable agreement between worst case estimates and the empirical results is attributed to the fact that the optimization takes advantage of aliasing to produce an optimal plan. We predicted and empirically demonstrated that an isotropic dose grid with <2.5 mm spacing is sufficient to prevent dose errors larger than a percent. However, we noted that in practice this resolution is mostly needed in high-dose target regions. Finally, a multiresolution 2-4-6 mm spacing model was developed and empirically tested where these spacings were applied to targets, structures, and tissue, respectively.


Subject(s)
Algorithms , Models, Biological , Radiometry/methods , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Conformal/methods , Body Burden , Computer Simulation , Dose-Response Relationship, Radiation , Fourier Analysis , Radiation Protection/methods , Radiotherapy Dosage , Relative Biological Effectiveness , Reproducibility of Results , Sensitivity and Specificity
15.
Phys Med Biol ; 49(10): 1991-2013, 2004 May 21.
Article in English | MEDLINE | ID: mdl-15214537

ABSTRACT

Models for finding treatment plans for intensity modulated radiation therapy are usually based on a number of structure-based treatment plan evaluation criteria, which are often conflicting. Rather than formulating a model that a priori quantifies the trade-offs between these criteria, we consider a multi-criteria optimization approach that aims at finding the so-called undominated treatment plans. We present a unifying framework for studying multi-criteria optimization problems for treatment planning that establishes conditions under which treatment plan evaluation criteria can be transformed into convex criteria while preserving the set of undominated treatment plans. Such transformations are identified for many of the criteria that have been proposed to date, establishing equivalences between these criteria. In addition, it is shown that the use of a nonconvex criterion can often be avoided by transformation to an equivalent convex criterion. In particular, we show that models employing criteria such as tumour control probability, normal tissue complication probability, probability of uncomplicated tumour control, as well as sigmoidal transformations of (generalized) equivalent uniform dose are equivalent to models formulated in terms of separable voxel-based criteria that penalize dose in individual voxels.


Subject(s)
Radiotherapy Planning, Computer-Assisted/methods , Dose-Response Relationship, Radiation , Humans , Models, Statistical , Models, Theoretical , Radiotherapy, Conformal/methods , Software
16.
Phys Med Biol ; 48(21): 3521-42, 2003 Nov 07.
Article in English | MEDLINE | ID: mdl-14653560

ABSTRACT

We present a novel linear programming (LP) based approach for efficiently solving the intensity modulated radiation therapy (IMRT) fluence-map optimization (FMO) problem to global optimality. Our model overcomes the apparent limitations of a linear-programming approach by approximating any convex objective function by a piecewise linear convex function. This approach allows us to retain the flexibility offered by general convex objective functions, while allowing us to formulate the FMO problem as a LP problem. In addition, a novel type of partial-volume constraint that bounds the tail averages of the differential dose-volume histograms of structures is imposed while retaining linearity as an alternative approach to improve dose homogeneity in the target volumes, and to attempt to spare as many critical structures as possible. The goal of this work is to develop a very rapid global optimization approach that finds high quality dose distributions. Implementation of this model has demonstrated excellent results. We found globally optimal solutions for eight 7-beam head-and-neck cases in less than 3 min of computational time on a single processor personal computer without the use of partial-volume constraints. Adding such constraints increased the running times by a factor of 2-3, but improved the sparing of critical structures. All cases demonstrated excellent target coverage (> 95%), target homogeneity (< 10% overdosing and < 7% underdosing) and organ sparing using at least one of the two models.


Subject(s)
Algorithms , Head and Neck Neoplasms/radiotherapy , Models, Biological , Programming, Linear , Radiometry/methods , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Conformal/methods , Computer Simulation , Energy Transfer/physiology , Humans , Quality Control , Radiotherapy Dosage , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...