Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Annu Int Conf IEEE Eng Med Biol Soc ; 2016: 4951-4954, 2016 Aug.
Article in English | MEDLINE | ID: mdl-28269379

ABSTRACT

This work summarizes the energy generation limits from walking employing a pendulum-based generation system. Self-winding wristwatches have exploited successfully this energy input technique for decades. Pendulum-based planar devices use the rotation to produce energy for inertial generators. Then the oscillations of body motion during locomotion present an opportunity to extract kinetic energy from planar generators. The sinusoidal motion of the center of gravity of the body, on the sagittal and frontal planes, and the limbs swinging are compliant with oscillating devices. Portable biomedical devices can extract energy from everyday walking to extend battery life or decrease battery size. Computer simulations suggest energy availability of 0.05-1.2 mJ on the chest, 0.5-2.5 mJ on the hip and 0.5-41 mJ on the elbow from walking.


Subject(s)
Bioelectric Energy Sources , Walking/physiology , Biomechanical Phenomena , Computer Simulation , Humans
2.
Article in English | MEDLINE | ID: mdl-23365941

ABSTRACT

This paper explores the feasibility of a new sensing platform for knee implant diagnostics. The proposed unit measures force and transmits the reading information wirelessly to an external receiving unit. This device is to be located in the tibial tray of the knee implant. The system measures force through the use of piezoelectric elements housed in the insert. At the same time, the piezoelectric material can generate enough energy to transmit the measurements without requiring batteries. Only the modeling of the piezoelectric voltage output is discussed at present. The force measurement can provide useful information about ligament balance while helping in the post-operative physical therapy.


Subject(s)
Knee Prosthesis , Telemetry/instrumentation , Bioelectric Energy Sources , Biomechanical Phenomena , Humans , Models, Biological , Osteoarthritis, Knee/physiopathology , Osteoarthritis, Knee/surgery , Pressure , Weight-Bearing/physiology
3.
Article in English | MEDLINE | ID: mdl-21096868

ABSTRACT

Energy harvesting from body motion is an alternative power source that can be used to energize miniature electronic biomedical devices. This technology can make it possible to recharge batteries to reduce the frequency of or eliminate surgeries to replace depleted cells. Power availability evaluation from walking and running at several body locations and different speeds is presented. Treadmill tests were performed on 11 healthy subjects to measure the accelerations at the ankle, knee, hip, chest, wrist, elbow, upper arm, and side of the head. Power was estimated from the treadmill results since it is proportional to the acceleration magnitudes and the frequency of occurrence. Available power output from walking was found to be more than 0.5 mW/cm(3) for all body locations while being more than 10 mW/cm(3) for the ankle and knee. Running results were at least 10 times higher than those from walking. An axial flux miniature electric dynamo using electromagnetic induction was evaluated for power generation. The device was composed of a rotor with multiple-pole permanent magnets positioned on an annular ring having an eccentric mass, and stacked planar coils as a stator. A 2 cm(3) prototype was found to generate 117 microW of power from the generator placed laterally on the ankle while walking.


Subject(s)
Bioelectric Energy Sources , Equipment and Supplies , Motion , Acceleration , Adult , Female , Humans , Kinetics , Male , Miniaturization , Walking
4.
Article in English | MEDLINE | ID: mdl-19964048

ABSTRACT

Kinetic energy harvesting has been demonstrated as a useful technique for powering portable electronic devices. Body motion can be used to generate energy to power small electronic devices for biomedical applications. These scavengers can recharge batteries, extending their operation lifetime or even replace them. This paper addresses the generation of energy from human activities. An axial flux generator is presented using body motion for powering miniature biomedical devices. This generator presents a gear-shaped planar coil and a multipole NdFeB permanent magnet (PM) ring with an attached eccentric weight. The device generates energy by electromagnetic induction on the planar coil when subject to a changing magnetic flux due to the generator oscillations produced by body motion. A 1.5 cm(3) prototype has generated 3.9 microW of power while walking with the generator placed laterally on the ankle.


Subject(s)
Bioelectric Energy Sources , Electronics, Medical , Motion , Acceleration , Algorithms , Biomechanical Phenomena , Computer Simulation , Electricity , Electronics , Equipment Design , Humans , Muscle, Skeletal/physiology , Walking
SELECTION OF CITATIONS
SEARCH DETAIL
...