Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 15 de 15
Filter
Add more filters










Publication year range
1.
Opt Express ; 31(24): 40293-40307, 2023 Nov 20.
Article in English | MEDLINE | ID: mdl-38041334

ABSTRACT

Terahertz spectroscopy is a promising method to diagnose ocular diseases, where the cornea is typically imaged by Gaussian beams. However, the beam's mismatch with the cornea's spherical surface produces a 5-10 % error in analysis. We investigate cornea spectroscopy with wavefront-modified vector beams, reducing the original analysis error to less than 0.5 %. Vector beams are synthesized by our developed 3D Angular Spectrum Method expanded to vector spherical harmonic presentation, allowing wavefront modification and scattering analysis from 100-layer cornea models. We show that wavefront-modified spherical vector beams possess increased accuracy and non-sensitive focusing on cornea spectroscopy compared to the Gaussian beams. Additionally, we investigate wavefront-modified cylindrical vector beams, which show frequency-dependent scattering power arising from s- and p-polarizations. As a result, these beams are unsuitable for cornea spectroscopy, although they have potential for optical force applications. Wavefront-modified vector beams can be applied to spherical target spectroscopy and optical force applications, such as medicine, medical imaging, and optical tweezers.

2.
Opt Express ; 31(23): 38653-38665, 2023 Nov 06.
Article in English | MEDLINE | ID: mdl-38017965

ABSTRACT

Mie theory is a powerful method to model electromagnetic scattering from a multilayered sphere. Usually, the incident beam is expanded to its vector spherical harmonic representation defined by beam shape coefficients, and the multilayer sphere scattering is obtained by the T-matrix method. However, obtaining the beam shape coefficients for arbitrarily shaped incident beams has limitations on source locations and requires different methods when the incident beam is defined inside or outside the computational domain or at the scatterer surface. We propose a 3D angular spectrum method for defining beam shape coefficients from arbitrary source field distributions. This method enables the placement of the sources freely within the computational domain without singularities, allowing flexibility in beam design. We demonstrate incident field synthesis and spherical scattering by comparing morphology-dependent resonances to known values, achieving excellent matching and high accuracy. The proposed method has significant benefits for optical systems and inverse beam design. It allows for the analysis of electromagnetic forward/backward propagation between optical elements and spherical targets using a single method. It is also valuable for optical force beam design and analysis.

3.
Sensors (Basel) ; 23(9)2023 Apr 28.
Article in English | MEDLINE | ID: mdl-37177578

ABSTRACT

Morphological microwave imaging has shown interesting results on reconstructing biological objects inside the human body, and these parameters represent their actual biological condition, but not their biological activity. In this paper, we propose a novel microwave technique to locate the low-frequency (f≃1 kHz) -modulated signals produced by a microtag mimicking an action potential and proved it in a cylindrical phantom of the brain region. A set of two combined UWB microwave applicators, operating in the 0.5 to 2.5 GHz frequency band and producing a nsec interrogation pulse, is able to focus its radiated field into a small region of the brain containing the microtag with a modulated photodiode. The illuminating UWB microwave field was first modulated by the low-frequency (f≃1 kHz) electrical signal produced by the photodiode, inducing modulated microwave currents into the microtag that reradiating back towards the focusing applicators. At the receiving end, the low-frequency (f≃1 kHz) -modulated signal was first extracted from the full set of the backscattered signals, then focused into the region of interest and spatially represented in the corresponding region of the brain, resulting in a spatial resolution of the images in the order of 10 mm.


Subject(s)
Microwave Imaging , Microwaves , Humans , Diagnostic Imaging , Phantoms, Imaging , Brain/diagnostic imaging
4.
Opt Express ; 31(26): 43583-43599, 2023 Dec 18.
Article in English | MEDLINE | ID: mdl-38178451

ABSTRACT

The angular spectrum method is a rigorous method to synthesize near and far-field electromagnetic beams from planar field distributions. However, this limitation of planar surfaces has restricted its applicability to beams with simple focal planes. We propose a curved boundary integral method (CBIM) to synthesize electromagnetic beams from arbitrary surfaces to address this limitation and expand the method's scope to synthesize beams from and between shaped objects. This study presents a detailed theoretical framework behind the CBIM and validates its effectiveness and accuracy with a comprehensive set of simulations. Additionally, we present mathematical proof to support our proposal. The proposed method satisfies Maxwell's equations and significantly benefits optical systems and inverse beam design. It allows for analyzing electromagnetic forward/backward propagation between optical elements using a single method. It is also valuable for optical force beam design and analysis.

5.
Biomed Opt Express ; 13(7): 3699-3722, 2022 Jul 01.
Article in English | MEDLINE | ID: mdl-35991916

ABSTRACT

Coupling to longitudinal modes of thin spherical shells, under Gaussian-beam illumination, was explored with a theoretical method based on Fourier-optics analysis and vector spherical harmonics and was scrutinized with an experimental setup. For the theory part, the illumination frequency band was fixed between 100-600 GHz and the outer spherical shell radius of curvature and thickness are 7.5 mm and 0.5 mm, respectively. The shell material was either the lossless cornea or an aqueous effective media representing the cornea. Six different beam-target strategies were introduced being potential candidates for maximum coupling. Two dispersion-tuned beam ensembles with strongly frequency-dependent phase center location have been created with a fixed incident beam 1/e radius and radius of curvature called forward strategies. These computations of different alignments were continued with four beam ensembles of frequency-invariant phase center, constructed from fits to experimental data, oriented at four different axial locations with respect to the spherical shell center of curvature, they are called reverse strategies. Coupling efficiency for all strategies was calculated for different targets including perfect electrical conductor (PEC) sphere, PEC core covered by a cornea loss-free layer and cornea. All scattering strategies contrasted to scattering from equivalent planar targets as a reference with maximum coupling. The results show that, under an ideal calibration, forward strategies are a closer approximation to the plane-wave condition for the cornea. An experimental setup was assembled to explore the simulation approach in a frequency range between 220 GHz to 330 GHz. Two different quartz samples with permittivity of 4.1 were mounted on a water core, acting for a cornea. The first and second quartz radius and thickness were 7.5 mm and 0.5 mm and 8 mm and 1 mm, respectively. An adequate agreement between theory and experiment was confirmed. A particle optimisation swarm algorithm was applied to extract the thickness and permittivity of quartz from the measured back-scattered field for reverse strategies.

6.
Sensors (Basel) ; 22(14)2022 Jul 16.
Article in English | MEDLINE | ID: mdl-35891008

ABSTRACT

A 3D-printed phased array consisting of four H-Sectorial horn antennas of 200 g weight with an ultra-wideband rectangular-waveguide-to-microstrip-line transition operating over the whole LMDS and K bands (24.25-29.5 GHz) is presented. The transition is based on exciting three overlapped transversal patches that radiate into the waveguide. The transition provides very low insertion losses, ranging from 0.30 dB to 0.67 dB over the whole band of operation (23.5-30.4 GHz). The measured fractional bandwidth of the phased array including the transition was 20.8% (24.75-30.3 GHz). The antenna was measured for six different scanning angles corresponding to six different progressive phases α, ranging from 0° to 140° at the central frequency band of operation of 26.5 GHz. The maximum gain was found in the broadside direction α = 0°, with 15.2 dB and efficiency η = 78.5%, while the minimum was found for α = 140°, with 13.7 dB and η = 91.2%.

7.
Sensors (Basel) ; 22(9)2022 Apr 22.
Article in English | MEDLINE | ID: mdl-35590925

ABSTRACT

Improving the longitudinal modes coupling in layered spherical structure contributes significantly to corneal terahertz sensing, which plays a crucial role in the early diagnosis of cornea dystrophies. Using a steel sphere to calibrate reflection from the cornea sample assists in enhancing the resolution of longitudinal modes. The requirement and challenges toward applying the calibration sphere are introduced and addressed. Six corneas with different properties are spotted to study the effect of perturbations in the calibration sphere in a frequency range from 100 GHz to 600 GHz. A particle-swarm optimization algorithm is employed to quantify corneal characteristics considering cases of accurately calibrated and perturbed calibrated scenarios. For the first case, the study is carried out with signal-to-noise values of 40 dB, 50 dB and 60 dB at waveguide bands WR-5.1, WR-3.4, and WR-2.2. As expected, better estimation is achieved in high-SNR cases. Furthermore, the lower waveguide band is revealed as the most proper band for the assessment of corneal features. For perturbed cases, the analysis is continued for the noise level of 60 dB in the three waveguide bands. Consequently, the error in the estimation of corneal properties rises significantly (around 30%).


Subject(s)
Terahertz Imaging , Algorithms , Calibration , Cornea/diagnostic imaging , Refraction, Ocular
8.
Sensors (Basel) ; 22(7)2022 Mar 22.
Article in English | MEDLINE | ID: mdl-35408055

ABSTRACT

Detection of bioparticles is of great importance in electrophoresis, identification of biomass sources, food and water safety, and other areas. It requires a proper model to describe bioparticles' electromagnetic characteristics. A numerical study of Escherichia coli bacteria during their functional activity was carried out by using two different geometrical models for the cells that considered the bacteria as layered ellipsoids and layered spheres. It was concluded that during cell duplication, the change in the dielectric permittivity of the cell is high enough to be measured at radio frequencies of the order of 50 kHz. An experimental setup based on the capacitive Wheatstone bridge was designed to measure relative changes in permittivity during cell division. In this way, the theoretical model was validated by measuring the dielectric permittivity changes in a cell culture of Escherichia coli ATTC 8739 from WDCM 00012 Vitroids. The spheroidal model was confirmed to be more accurate.


Subject(s)
Biosensing Techniques , Escherichia coli Infections , Escherichia coli , Humans , Models, Theoretical , Radio Waves
9.
Sensors (Basel) ; 23(1)2022 Dec 27.
Article in English | MEDLINE | ID: mdl-36616869

ABSTRACT

The need for non-ionizing techniques for medical imaging applications has led to the use of microwave signals. Several systems have been introduced in recent years based on increasing the number of antennas and frequency bandwidth to obtain high resolution and good accuracy in locating objects. A novel microwave imaging system that reduces the number of required antennas for precise target location appropriate for medical applications is presented. The proposed system consists of four UWB extended gap ridge horn (EGRH) antennas covering the frequency band from 0.5 GHz to 1.5 GHz mounted on a cylindrical phantom that mimics the brain in an orthogonal set of two EGRH probes. This configuration has the ability to control both the longitudinal and transversal dimensions of the reconstructed target's image, rather than controlling the spatial resolution, by increasing the frequency band that can be easily affected by medium losses. The system is tested numerically and experimentally by the detection of a cylindrical target within a human brain model.


Subject(s)
Microwave Imaging , Microwaves , Humans , Diagnostic Imaging/methods , Phantoms, Imaging
10.
Sensors (Basel) ; 21(11)2021 May 30.
Article in English | MEDLINE | ID: mdl-34070879

ABSTRACT

The current trend in vehicles is to integrate a wide number of antennae and sensors operating at a variety of frequencies for sensing and communications. The integration of these antennae and sensors in the vehicle platform is complex because of the way in which the antenna radiation patterns interact with the vehicle structure and other antennae/sensors. Consequently, there is a need to study the radiation pattern of each antenna or, alternatively, the currents induced on the surface of the vehicle to optimize the integration of multiple antennae. The novel concept of differential imaging represents one method by which it is possible to obtain the surface current distribution without introducing any perturbing probe. The aim of this study was to develop and confirm the assumptions that underpin differential imaging by means of full-wave electromagnetic simulation, thereby providing additional verification of the concept. The simulation environment and parameters were selected to replicate the conditions in which real measurements were taken in previous studies. The simulations were performed using Ansys HFSS simulation software. The results confirm that the approximations are valid, and the differential currents are representative of the induced surface currents generated by a monopole positioned on the top of a vehicle.

11.
Sensors (Basel) ; 20(19)2020 Oct 02.
Article in English | MEDLINE | ID: mdl-33023093

ABSTRACT

The next generation of connected and autonomous vehicles will be equipped with high numbers of antennas operating in a wide frequency range for communications and environment sensing. The study of 3D spatial angular responses and the radiation patterns modified by vehicular structure will allow for better integration of the associated communication and sensing antennas. The use of near-field monostatic focusing, applied with frequency-dimension scale translation and differential imaging, offers a novel imaging application. The objective of this paper is to theoretically and experimentally study the method of obtaining currents produced by an antenna radiating on top of a vehicular platform using differential imaging. The experimental part of the study focuses on measuring a scaled target using an imaging system operating in a terahertz band-from 220 to 330 GHz-that matches a 5G frequency band according to frequency-dimension scale translation. The results show that the induced currents are properly estimated using this methodology, and that the influence of the bandwidth is assessed.

12.
Sensors (Basel) ; 20(20)2020 Oct 21.
Article in English | MEDLINE | ID: mdl-33096912

ABSTRACT

An RFID-based wireless system to measure the evolution of the setting process of cement-based materials is presented in this paper. The system consists of a wireless RFID temperature sensor that works embedded in concrete, and an external RFID reader that communicates with the embedded sensor to extract the temperature measurement conducted by the embedded sensor. Temperature time evolution is a well known proxy to monitor the setting process of concrete. The RFID sensor consisting of an UWB Bow Tie antenna with central frequency 868 MHz, matched to the EM4325 temperature chip through a T-match structure for embedded operation inside concrete is fully characterized. Results for measurements of the full set up conducted in a real-scenario are provided.

13.
Materials (Basel) ; 13(13)2020 Jun 27.
Article in English | MEDLINE | ID: mdl-32605064

ABSTRACT

The assessment of the dynamic behaviour of resilient elements can be performed using the indirect method as described in the standard ISO 10846-3. This paper presents a methodology for control the error on the estimation of the frequency response functions (FRF) required for the application of the indirect method when sweep sine excitation is used. Based on a simulation process, this methodology allows for the design of the sweep sine excitation parameters, i.e., the sweep rate and the force amplitude, to control three types of errors associated to the experimentally obtained FRF in the presence of background noise: a general error of the FRF in a selected frequency range, and the errors associated to the amplitude and the frequency of the FRF resonance peak. The signal processing method used can be also tested with this methodology. The methodology has been tested in the characterisation of two different resilient elements: an elastomer and a coil spring. The simulated error estimations has been found to be in good agreement with the errors found in the measured FRF. Furthermore, it is found that for large signal-to-noise ratios, both sweep rate and force amplitude significantly affect the FRF estimation error, while, for small signal-to-noise ratios, only the force amplitude can control the error efficiently. The current methodology is specially interesting for laboratory test rigs highly used for the dynamic characterisation of resilient elements which are required to operate efficiently, since it can be used for minimising test times and providing quality assurance. Moreover, the application of this methodology would be specially relevant when characterisation is done in noisy environments.

14.
Sensors (Basel) ; 20(6)2020 Mar 11.
Article in English | MEDLINE | ID: mdl-32168736

ABSTRACT

Millimeter-wave and terahertz frequencies offer unique characteristics to simultaneously obtain good spatial resolution and penetrability. In this paper, a robust near-field monostatic focusing technique is presented and successfully applied for the internal imaging of different penetrable geometries. These geometries and environments are related to the growing need to furnish new vehicles with radar-sensing devices that can visualize their surroundings in a clear and robust way. Sub-millimeter-wave radar sensing offers enhanced capabilities in providing information with a high level of accuracy and quality, even under adverse weather conditions. The aim of this paper was to research the capability of this radar system for imaging purposes from an analytical and experimental point of view. Two sets of measurements, using reference targets, were performed in the W band at 100 GHz (75 to 110 GHz) and terahertz band at 300 GHz (220 to 330 GHz). The results show spatial resolutions of millimeters in both the range (longitudinal) and the cross-range (transversal) dimensions for the two different imaging geometries in terms of the location of the transmitter and receiver (frontal or lateral views). The imaging quality in terms of spatial accuracy and target material parameter was investigated and optimized.

15.
Med Phys ; 2018 May 28.
Article in English | MEDLINE | ID: mdl-29807391

ABSTRACT

PURPOSE: Colorectal cancer is highly preventable by detecting and removing polyps, which are the precursors. Currently, the most accurate test is colonoscopy, but still misses 22% of polyps due to visualization limitations. In this paper, we preliminary assess the potential of microwave imaging and dielectric properties (e.g., complex permittivity) as a complementary method for detecting polyps and cancer tissue in the colon. The dielectric properties of biological tissues have been used in a wide variety of applications, including safety assessment of wireless technologies and design of medical diagnostic or therapeutic techniques (microwave imaging, hyperthermia, and ablation). The main purpose of this work is to measure the complex permittivity of different types of colon polyps, cancer, and normal mucosa in ex vivo human samples to study if the dielectric properties are appropriate for classification purposes. METHODS: The complex permittivity of freshly excised healthy colon tissue, cancer, and histological samples of different types of polyps from 23 patients was characterized using an open-ended coaxial probe between 0.5 and 20 GHz. The obtained measurements were classified into five tissue groups before applying a data reduction step with a frequency dispersive single-pole Debye model. The classification was finally compared with pathological analysis of tissue samples, which is the gold standard. RESULTS: The complex permittivity progressively increases as the tissue degenerates from normal to cancer. When comparing to the gold-standard histological tissue analysis, the sensitivity and specificity of the proposed method is the following: 100% and 95% for cancer diagnosis; 91% and 62% for adenomas with high-grade dysplasia; 100% and 61% for adenomas with low-grade dysplasia; and 100% and 74% for hyperplastic polyps, respectively. In addition, complex permittivity measurements were independent of the lesion shape and size, which is also an interesting property comparing to current colonoscopy techniques. CONCLUSIONS: The contrast in complex permittivities between normal and abnormal colon tissues presented here for the first time demonstrate the potential of these measurements for tissue classification. It also opens the door to the development of a microwave endoscopic device to complement the outcomes of colonoscopy with functional tissue information.

SELECTION OF CITATIONS
SEARCH DETAIL
...