1.
J Endovasc Ther ; : 15266028231202456, 2023 Sep 26.
Article in English | MEDLINE | ID: mdl-37750487

ABSTRACT

PURPOSE: This article aims at investigating the outcomes of percutaneous access via the first versus third axillary artery (AXA) segments with closure devices during aortic procedures. MATERIALS AND METHODS: All patients receiving percutaneous AXA access closed with Perclose ProGlide device (Abbott, Santa Clara, California) from 2008 to 2021 were included in a retrospective multicenter registry (NCT: 04589962). Efficacy endpoint was the technically successful percutaneous procedure (no open conversion). Safety endpoints were stroke and access complications according to the Valve Academic Research Consortium-3 reporting standards. The first (AXA1) or third (AXA3) axillary puncture sites were compared. RESULTS: A total of 412 percutaneous AXA accesses were included: 172 (42%) in AXA1 and 240 (58%) in AXA3. Left AXA was catheterized in 363 cases (76% of AXA1 vs 97% of AXA3, p<0.001) and 91% of fenestrated/branched endovascular repair (F/BEVAR) procedures were conducted from the left. A ≥12F internal diameter (ID) sheath was used in 49% of procedures. Open conversion rate was 1%, no major vascular complications occurred, and only one major non-vascular complication was recorded. Primary closure failure occurred in 18 AXA1 (11%) and 32 AXA3 accesses (13%), treated by covered (8.3%) or bare-metal (2.7%) stenting. Bailout stent patency was 100% at median follow-up of 12 months, with 6 of 6 stents still patent after >36 months of follow-up. Stroke rate was 4.4%. An introducer sheath >12F was independently associated with both access complications (p<0.001) and stroke (p=0.005), while a right-side access was associated with stroke only (p=0.034). Even after adjustment for covariates, AXA1 versus AXA3 showed an equal success rate (odds ratio [OR]=0.537, 95% confidence interval [CI]=0.011-1.22 for AXA3, p=0.104). The combination of AXA3 and a >10F introducer sheath provided worse outcomes compared with >10F sheaths through AXA1 (OR for success=0.367, 95% CI=0.176-0.767, p=0.008). This was not confirmed for >12F sheaths, associated with similar outcomes (p=0.31 AXA 1 vs AXA 3). CONCLUSION: Major local complications with the percutaneous axillary approach and ≤12F sheaths are infrequent and solvable by complementary endovascular interventions. Stroke risk remains an issue. First and third AXA segments are both amenable for access with good results, but larger sheaths (12F) perform better in AXA1. CLINICAL IMPACT: Percutaneous access with vascular closure devices at the first or third axillary artery (AXA) segments during aortic procedures is burdened by a negligible risk of open conversion. Local complications with the percutaneous axillary approach are infrequent and solvable by complementary endovascular interventions. First and third AXA segments are both amenable to access with excellent results, but larger sheaths (12F) perform better in the wider first AXA segment. In this setting, bailout stenting does not appear to be associated with mid-term stent occlusion.

2.
Ann Surg ; 277(2): e460-e466, 2023 02 01.
Article in English | MEDLINE | ID: mdl-33714965

ABSTRACT

OBJECTIVE: To assess the initial clinical experience with a novel endograft system (NEXUS Aortic Arch Stent Graft System) designed to treat aortic arch pathologies and address the morphology and hemodynamic challenges of the aortic arch. SUMMARY BACKGROUND DATA: The aortic arch remains the most challenging part of the aorta for both open and endovascular repair. Transcatheter aortic arch repair has the potential to significantly reduce surgical risks. METHODS: Patients underwent transcatheter aortic arch repair with a single branch, 2 stent graft system, implanted over a through-and-through guidewire from the brachiocephalic trunk, to the descending aorta with an ascending aorta stent graft. The ascending aorta stent graft is deployed into a designated docking sleeve to connect the 2 stent grafts and isolate the aortic arch pathology. Proximal landing zone in all cases was in Zone 0. Anatomical inclusion criteria included adequate landing zone in the ascending aorta, brachiocephalic trunk, and descending thoracic aorta. Preparatory debranching procedure was performed in all patients with carotid-carotid crossover bypass and left carotid to left subclavian bypass, or parallel graft from descending aorta to left subclavian artery. Safety and performance were evaluated through 1 year. Survival analysis used the Kaplan-Meier method. RESULTS: Twenty-eight patients, 79% males, with a mean age of 72.2 ± 6.2 years were treated with 100% procedural success. Isolated aortic arch aneurysm was the principle pathology in 17 (60.7%) of patients, while chronic aortic dissection was the principle pathology in 6 (21.4%) of patients. The remaining 5 (17.8%) had combined or other pathologies. At 1 month, the vascular pathology was excluded in 25 of 26 alive patients (96.1%). The 30 days mortality rate was 7.1%, stroke rate was 3.6% (all nondisabling), and combined mortality/stroke rate was 10.7%. One-year mortality was 10.7%, without device or aneurysm-related death. Two patients (7.1%) reported stroke or transient ischemic attack at 1 year that recovered completely. One year combined mortality/stroke rate was 17.8%. There were 3 patients (10.7%) that had device-related unplanned reinterventions through 1 year. CONCLUSIONS: The NEXUS Aortic Arch Stent Graft System, a novel single branch, 2 stent graft system used for endovascular aortic arch repair that requires landing in the ascending aorta, demonstrates a high success rate with excellent 1 year safety and performance.


Subject(s)
Aortic Dissection , Stroke , Male , Humans , Aged , Female , Aorta, Thoracic/surgery , Aorta , Stents , Aortic Dissection/surgery
3.
Curr Pharm Des ; 29(2): 133-138, 2023.
Article in English | MEDLINE | ID: mdl-36515041

ABSTRACT

BACKGROUND: Percutaneous transluminal renal angioplasty (PTRA) with or without stenting is the gold standard therapy in patients with atherosclerotic renal artery stenosis (aRAS). However, therapeutic success depends on the correct timing of revascularization and the reversibility of the renal damage. MATERIALS AND METHODS: We report a case series of patients treated with PTRA for renovascular hypertension and ischemic nephropathy. We measured bilateral renal resistive index (RRI), circulating renal stem cells (RSC), and Neutrophil Gelatinase Associated Lipocalin (NGAL) at baseline and after PTRA at different time points to understand their changes in post-revascularization. RESULTS: At baseline, the studied patients (n = 5) had different RSC levels. After PTRAs, all patients showed an improvement in blood pressure, while renal function varied differently within the studied subjects. RRI > 0.75 at baseline and the absence of NGAL decrease after PTRAs were associated with post-PTRA renal function worsening, despite an increase of RSC in all patients. CONCLUSION: Although limited to a few patients, our observation allowed the exploration of the behaviour of the studied parameters in different degrees of renal ischemia. This revealed different disease models suggesting the importance of further investigations in larger and homogeneous cohorts to confirm that a greater basal RSC percentage, low RRI values before PTRA, and a post-revascularization NGAL reduction could be related to better renal outcomes in aRAS patients.


Subject(s)
Hypertension, Renovascular , Humans , Hypertension, Renovascular/surgery , Lipocalin-2 , Kidney/physiology , Angioplasty , Stem Cells
4.
Eur J Cardiothorac Surg ; 63(1)2022 12 02.
Article in English | MEDLINE | ID: mdl-36484696

ABSTRACT

OBJECTIVES: Endovascular aortic arch stent grafting with branched devices has shown initial promising results. The aim of this prospective, multicentre study was to evaluate 3-year outcomes of aortic arch stent grafting with NEXUS® Aortic Arch Stent Graft System (Nexus), a single-branch, bi-modular, off-the-shelf aortic arch stent graft system in high-risk patients. METHODS: Patients treated with Nexus, either under the feasibility clinical study or as compassionate use procedures in 5 centres, were included in this study. The primary end point was overall survival. The secondary end points included the incidence of procedure-related unplanned intervention, stroke, paraplegia and endoleak. Clinical and radiologic follow-up was performed at each study site at 30 days, 6 months and on a yearly basis thereafter up to 3 years postoperatively. RESULTS: We analysed data from a total of 28 patients. The overall median follow-up was 1132 (interquartile range: 809-1537). There were no device or procedure-related deaths between 1 and 3 years. Overall survival at 1 and 3 years was 89% and 71%, respectively. The cumulative incidence of unplanned reintervention at 1 and 3 years was 11% and 29%, respectively. There were no reports of stroke, paraplegia, aneurysm rupture, myocardial infarction or new aortic valve insufficiency. In this study's 1-3 year follow-up period, 1 type Ib (4%), 1 type II (4%) and 2 type III (8%; between Nexus' distal end and Thoracic endovascular aortic repair (TEVAR) extensions) endoleak were detected. CONCLUSIONS: Endovascular aortic arch exclusion with the single-branch, off-the-shelf Nexus system provides promising clinical and radiologic results at 3-year follow-up in a high-risk patient cohort.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Stroke , Humans , Blood Vessel Prosthesis/adverse effects , Endoleak/epidemiology , Endoleak/etiology , Endovascular Aneurysm Repair , Follow-Up Studies , Prospective Studies , Postoperative Complications , Stents/adverse effects , Stroke/etiology , Treatment Outcome , Retrospective Studies
5.
J Vasc Surg ; 76(2): 326-334, 2022 08.
Article in English | MEDLINE | ID: mdl-35314297

ABSTRACT

OBJECTIVES: To assess the outcomes of Cook t-Branch off-the-shelf multibranched stent graft in the treatment of complex aortic aneurysms with narrow internal aortic lumen. METHODS: Between 2016 and 2020, 48 patients (mean age, 73 years) underwent elective or urgent or emergent Cook t-Branch implantation for thoracoabdominal or para/juxtarenal aortic aneurysms in two Italian vascular centers. Among these, 20 patients presented a paravisceral or pararenal luminal diameter of less than 25 mm. Major clinical and radiologic outcomes of patients with narrow aortic lumen were compared with patients with a larger lumen in a multicenter, nonrandomized, retrospective fashion. RESULTS: The in-hospital mortality was 10% (5% in the elective setting). Spinal cord ischemia occurred in 6% of the cases. During a mean follow-up of 18 months (range, 1-63 months), late t-Branch procedure-related mortality and the need for reintervention was 0% and 12%, respectively. Comparing the outcomes of patients with large internal aortic lumen (group 1) with patients with small lumen (group 2), no significant difference was found regarding fluoroscopy time (P = .3); technical success (P = 1); early (P = .4) and late (P = 1) mortality; spinal cord ischemia (P = .2); bowel ischemia (P = .5); renal (P = .7), cardiac (P = 1), and respiratory complications (P = 1); reintervention rate (P = 1); and primary patency rate of stented target vessels (P = 1). CONCLUSIONS: The use of the Cook t-Branch in our experience was safe and effective in the treatment of complex aortic aneurysms regardless the caliber of the aortic lumen. With all the limitations of a small sample size, this approach has demonstrated to be feasible when maneuverability is decreased, with low mortality and morbidity, and acceptable reintervention rates. Perioperative mortality remains closely related to clinical presentation. Large-scale studies are needed to confirm these results.


Subject(s)
Aortic Aneurysm, Thoracic , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Spinal Cord Ischemia , Aged , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis/adverse effects , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Procedures/adverse effects , Humans , Postoperative Complications , Prosthesis Design , Retrospective Studies , Risk Factors , Spinal Cord Ischemia/etiology , Stents/adverse effects , Time Factors , Treatment Outcome
6.
J Pers Med ; 12(3)2022 Feb 24.
Article in English | MEDLINE | ID: mdl-35330339

ABSTRACT

Introduction: The aim of the present study is to report the outcome of patients presenting an isolated type II endoleak (TIIEL) requiring reintervention and to identify clinical and anatomical characteristics potentially implicated in refractory TIIEL occurrence and fate. Materials and Methods: A multicenter retrospective study on TIIEL requiring reintervention was conducted between January 2003 and December 2020. Demographic and clinical characteristics, procedural technical aspects, reinterventions, and outcomes were recorded. TIIEL determining sac expansion greater than 10 mm underwent a further endovascular procedure aiming to exclude aneurismal sac. Redo endovascular procedures were performed via endoleak nidus direct embolization and/or aortic side branches occlusion. TIIELs responsible for persisting aneurysmal sac perfusion 6 months after redo endovascular procedures were classified as "refractory" and submitted to open conversion. Results: A total of 102 TIIEL requiring reintervention were included in the final analysis. Eighty-eight (86.27%) patients were male, the mean age was 77.32 ± 8.08 years, and in 72.55% of cases the American Society of Anaesthesiologists (ASA) class was ≥3. The mean aortic diameter was 64.7 ± 14.02 mm, half of treated patients had a patent inferior mesenteric artery (IMA), and 44.11% ≥ 3 couples of patent lumbar arteries (LA). In 49 cases (48.03%) standard endovascular aneurysm repair (EVAR) procedure was completed without adjunctive maneuvers. All enrolled patients were initially submitted to a further endovascular procedure once TIIEL requiring reintervention was diagnosed; 57 patients underwent LAs or IMA embolization (55.87%), 42 transarterial aneurismal sac embolization (41.17%), and three (2.96%) laparoscopic ostial ligations of the inferior mesenteric artery. During a mean follow-up of 15.22 ± 7.57 months (7−48), a redo endovascular approach was able to ensure complete sac exclusion in 52 cases, while 50 patients presented a still evident refractory TIIEL and therefore a surgical conversion or semiconversion was conducted. At the univariate analysis refractory TIIEL patients were significantly different from those who did not develop the complication in terms of preoperative clinical, morphological characteristics, and initial EVAR procedures: coronary artery disease occurrence (p = 0.005, OR: 3.18, CI95%: 1.3−7.2); preoperative abdominal aortic aneurysm (AAA) sac diameter (p = 0.0055); IMA patency (p = 0.016, OR: 2.64, CI95%: 1.18−5.90); three or more patent LAs; isolated standard EVAR without adjunctive procedures (p > 0.0001; OR: 9.48, CI95%: 3.84−23.4). Conclusions: Our experience seems to demonstrate that it is reasonable to try to preoperatively identify those patients who will develop a refractory TIIEL after EVAR and those with a TIIEL requiring reintervention for whom a simple endovascular redo will not be enough, needing surgical conversion.

7.
J Vasc Surg ; 75(3): 868-876.e3, 2022 03.
Article in English | MEDLINE | ID: mdl-34600031

ABSTRACT

BACKGROUND: The aim of the study was to demonstrate the safety and effectiveness of a suture-mediated vascular closure device to perform hemostasis after an axillary artery access during endovascular procedures on the aortic valve, the aorta and its side branches. METHODS: A physician-initiated, international, multicenter, retrospective registry was designed to evaluate the success rate (VARC-2 reporting standards) of percutaneous transaxillary access closure with a suture-mediated closure device. Secondary end points were minor access vascular complications, transient peripheral nerve injury, stroke, and influence on periprocedural outcomes of puncture technique. RESULTS: Three hundred thirty-one patients (median age, 76 years; 69.2% males) in 11 centers received a percutaneous transaxillary access during endovascular cardiac (n = 166) or vascular (n = 165) procedures. The closure success rate was 84.6%, with 5 open conversions (1.5%), 45 adjunctive endovascular procedures (13.6%), and 1 nerve injury (0.3%). Secondary closure success was obtained in 325 patients (98%) after 7 bare stenting, 37 covered stenting, and 1 thrombin injection. Introducer sheaths 16F or larger (odds ratio, 3.70; 95% confidence interval, 1.22-11.42) and balloon-assisted hemostasis (odds ratio, 4.45; 95% confidence interval, 1.27-15.68) were associated with closure failure. A threshold of five percutaneous axillary accesses was associated with decreased rates of open conversion, but not with increased primary closure success. Primary closure success was 90.3% in the 175 patients with sheaths smaller than 16F, performed after the first 5 procedures in each center. Temporary nerve injury and stroke were observed in 2% and 4% of patients, respectively. CONCLUSIONS: Percutaneous transaxillary aortic procedures, in selected patients, can be performed with low rates of open conversion. The need for additional endovascular bailout procedures is not negligible when introducers sheaths 16F or larger are required.


Subject(s)
Aorta, Thoracic/surgery , Aortic Diseases/surgery , Aortic Valve/surgery , Axillary Artery , Blood Vessel Prosthesis Implantation , Catheterization, Peripheral , Endovascular Procedures , Heart Valve Diseases/surgery , Aged , Aged, 80 and over , Aorta, Thoracic/diagnostic imaging , Aortic Diseases/diagnostic imaging , Aortic Valve/diagnostic imaging , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Catheterization, Peripheral/adverse effects , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Europe , Female , Heart Valve Diseases/diagnostic imaging , Humans , Male , Postoperative Complications/etiology , Punctures , Registries , Retrospective Studies , Risk Assessment , Risk Factors , Stents , Time Factors , Treatment Outcome , United States
8.
JACC Cardiovasc Interv ; 14(17): 1917-1923, 2021 09 13.
Article in English | MEDLINE | ID: mdl-34391704

ABSTRACT

OBJECTIVES: The aim of this study was to evaluate the 1-year safety and efficacy of a dual-layered stent (DLS) for carotid artery stenting (CAS) in a multicenter registry. BACKGROUND: DLS have been proved to be safe and efficient during short-term follow-up. Recent data have raised the concern that the benefit of CAS performed with using a DLS may be hampered by a higher restenosis rate at 1 year. METHODS: From January 2017 to June 2019, a physician-initiated, prospective, multispecialty registry enrolled 733 consecutive patients undergoing CAS using the CGuard embolic prevention system at 20 centers. The primary endpoint was the occurrence of death and stroke at 1 year. Secondary endpoints were 1-year rates of transient ischemic attack, acute myocardial infarction, internal carotid artery (ICA) restenosis, in-stent thrombosis, and external carotid artery occlusion. RESULTS: At 1 year, follow-up was available in 726 patients (99.04%). Beyond 30 days postprocedure, 1 minor stroke (0.13%), four transient ischemic attacks (0.55%), 2 fatal acute myocardial infarctions (0.27%), and 6 noncardiac deaths (1.10%) occurred. On duplex ultrasound examination, ICA restenosis was found in 6 patients (0.82%): 2 total occlusions and 4 in-stent restenoses. No predictors of target ICA restenosis and/or occlusion could be detected, and dual-antiplatelet therapy duration (90 days vs 30 days) was not found to be related to major adverse cardiovascular event or restenosis occurrence. CONCLUSIONS: This real-world registry suggests that DLS use in clinical practice is safe and associated with minimal occurrence of adverse neurologic events up to 12-month follow-up.


Subject(s)
Carotid Stenosis , Carotid Artery, Internal , Carotid Stenosis/diagnostic imaging , Carotid Stenosis/therapy , Humans , Prospective Studies , Stents , Treatment Outcome
9.
EuroIntervention ; 16(18): e1544-e1550, 2021 04 02.
Article in English | MEDLINE | ID: mdl-31793884

ABSTRACT

AIMS: The aim of this study was to report the 30-day technical and clinical success with endovascular repair using the ultra-low-profile Ovation stent graft in patients judged to be outside the instructions for use (IFU) for conventional endografts, while amenable to treatment within the IFU for Ovation. METHODS AND RESULTS: One hundred and twenty-two patients (78.65±7.67 years; 111 male) were enrolled. Patients were evaluated as being outside the IFU for standard endografts because of the absence of a suitable proximal aortic neck in 109 cases (89.3%), of inadequate access vessels in 13 (10.7%), or both in 111 (90.9%). Mean aneurysm (abdominal aortic aneurysm [AAA]) diameter was 52.96±10.1 mm; mean aortic neck length was 7.75±6.05 mm. Technical success (98.4%) was achieved in all but two patients due to a type Ia endoleak. At completion angiography, 15 (12.3%) patients presented a type II endoleak. All patients underwent 30-day follow-up. Primary clinical success at one month was 96.8%, assisted clinical success 98.4%. There were no type I endoleaks, while 12 (9.8%) type II endoleaks were still evident, in the absence of sac expansions. Two patients (1.6%) presented an asymptomatic limb occlusion. CONCLUSIONS: Our experience suggests that, in a selected population of patients with challenging anatomy outside the IFU for conventional endografts, endovascular aneurysm repair (EVAR) using the Ovation stent graft can be performed safely with satisfactory immediate outcomes.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Aortography , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Humans , Male , Prosthesis Design , Stents , Treatment Outcome
11.
JACC Cardiovasc Interv ; 13(18): 2170-2177, 2020 09 28.
Article in English | MEDLINE | ID: mdl-32861633

ABSTRACT

OBJECTIVES: This study sought to evaluate 30-day safety and efficacy of dual-layer mesh-covered carotid stent systems for carotid artery stenting (CAS) in the clinical practice. BACKGROUND: When compared with carotid endarterectomy, CAS has been associated with a higher rate of post procedural neurologic events; these could be related to plaque's debris prolapsing through stent's mesh. Consequently, the need for increased plaque coverage has resulted in the development of dual-layer mesh-covered carotid stent systems. METHODS: From January 2017 to June 2019, a physician-initiated, prospective, multispecialty registry enrolled 733 consecutive patients undergoing CAS using the CGuard embolic prevention system in 20 centers. The primary endpoint was stroke up to 30 days; secondary endpoints were technical and procedural success; external carotid artery occlusion; and in-hospital and 30-day transient ischemic attack (TIA), acute myocardial infarction (AMI), and death rates. RESULTS: Symptoms were present in 131 (17.87%) patients. An embolic protection device was used in 731 (99.72%) patients. Procedural success was 100%, technical success was obtained in all but 1 (99.86%) patient, who died in hospital due to a hemorrhagic stroke. Six TIAs, 2 minor strokes, and 1 AMI occurred during in-hospital stay, and external carotid artery occlusion was evident in 8 (1.09%) patients. Between hospital discharge and 30-day follow-up, 2 TIAs, 1 minor stroke, and 3 AMIs occurred. Therefore, the cumulative stroke rate was 0.54%. CONCLUSIONS: This real-world registry suggests that use of CGuard embolic prevention system in clinical practice is safe and associated with a minimal occurrence of adverse neurological events up to 30-day follow-up.


Subject(s)
Carotid Stenosis , Stroke , Humans , Prospective Studies , Stents , Time Factors , Treatment Outcome
12.
Eur J Vasc Endovasc Surg ; 60(3): 395-401, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32665199

ABSTRACT

OBJECTIVE: The objective of this prospective single centre study was to assess whether branches and fenestrations have different outcomes on renal function in the early phase. METHODS: From March 2018 to June 2019, 67 patients who underwent elective fenestrated and branched endovascular aneurysm repair (F/BEVAR) procedures were enrolled in this study. The patients were divided into two groups according to the renal bridging component configuration (fenestration vs. branch). All of them underwent dynamic renal scintigraphy with 99mTc diethylenetriaminepentaacetic acid (DTPA), two weeks pre-operatively, and three months and one year post-operatively. The primary end points were peri-procedural technical success, 30 day major adverse events, differences in glomerular filtration rate (GFR) between the branch and fenestration configurations, and variations between the pre-operative and the post-operative dynamic renal scintigraphy. RESULTS: Overall, 135 kidneys were analysed: 63 in the 32 patients treated with fenestrations, and 72 in the 35 patients treated with branches; the mean GFR on baseline scintigraphy was 58.4 ± 30.9 mL/min in the fenestration group, and 65.1 ± 29.2 mL/min in the branch group. Only kidneys associated with a patent fenestration/branch were included in the split GFR final analysis. The mean total GFR at three month scintigraphy decreased by 6.0 ± 2.9 mL/min in the fenestration group and by 23.4 ± 6.4 mL/min in the branch group. The split GFR decreased by 3.5 ± 0.6 mL/min in the fenestration group, and by 15.4 ± 5.4 mL/min in the branch group. The GFR decrease remained stable at one year. CONCLUSION: In this study, the use of branches for renal arteries during F/BEVAR resulted in a greater decrease in the GFR than in those patients who were treated with fenestrations alone. The scintigraphic alterations were evident at an early phase.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endovascular Procedures/instrumentation , Kidney Diseases/diagnostic imaging , Radionuclide Imaging , Renal Artery/surgery , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/physiopathology , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/physiopathology , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Procedures/adverse effects , Female , Glomerular Filtration Rate , Humans , Kidney Diseases/etiology , Kidney Diseases/physiopathology , Male , Predictive Value of Tests , Prospective Studies , Prosthesis Design , Radiopharmaceuticals/administration & dosage , Renal Artery/diagnostic imaging , Renal Artery/physiopathology , Technetium Tc 99m Pentetate/administration & dosage , Time Factors , Treatment Outcome
13.
Eur J Vasc Endovasc Surg ; 60(2): 181-191, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32709467

ABSTRACT

OBJECTIVE: The aim was to describe the outcomes of the Anaconda™ Fenestrated endograft Italian Registry for complex aortic aneurysms (AAAs), unsuitable for standard endovascular aneurysm repair (EVAR). METHODS: Between 2012 and 2018 patients with a proximal neck unsuitable for standard EVAR, treated with the fenestrated Anaconda™ endograft, were prospectively enrolled in a dedicated database. Endpoints were peri-operative technical success (TS) and evaluation of type Ia/b or 3 endoleaks (T1/3 EL), target visceral vessel (TVV) occlusion, re-interventions, and AAA related mortality at 30 days, six months, and later follow up. RESULTS: One hundred twenty seven patients (74 ± 7 years, American Society Anesthesiology (ASA) II/III/IV: 12/85/30) were included in the study in 49 Italian Vascular Surgery Units (83 juxta/para-renal AAA, 13 type IV thoraco-abdominal AAA, 16 T1aEL post EVAR, and 15 short neck AAA). Configurations with one, two, three, and four fenestrations were used in 5, 56, 39, and 27 cases, respectively, for a total of 342 visceral vessels. One hundred and eight (85%) bifurcated and 19 (15%) tube endografts were implanted. In 35% (44/127) of cases the endograft was repositioned during the procedure, and 37% (128/342) of TVV were cannulated from brachial access. TS was 87% (111/127): five T1EL, six T3EL (between fenestration and vessel stent), and six loss of visceral vessels (one patient with a Type Ia EL had also a TVV loss) occurred. Thirty day mortality was 4% (5/127). Two of the five T1EL resolved spontaneously at 30 days. The overall median follow up was 21 ± 16 months; one T1EL (5%) occurred at six months and one T3EL (4%) at the three year follow up. Another two (3%) TVV occlusions occurred at six months and five (3%) at three years. The re-intervention rate at the 30 days, six months, and three year follow up was 5%, 7%, and 18 ± 5%, respectively. CONCLUSION: The fenestrated Anaconda™ endograft is effective in the treatment of complex AAA. Some structure properties, such as the re-positionability and the possibility of cannulation from above, are specific characteristics helpful for the treatment of some complex anatomies.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endovascular Procedures/instrumentation , Aged , Aged, 80 and over , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/mortality , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/mortality , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/mortality , Endoleak/etiology , Endoleak/therapy , Endovascular Procedures/adverse effects , Endovascular Procedures/mortality , Female , Humans , Italy , Male , Prospective Studies , Prosthesis Design , Registries , Risk Factors , Time Factors , Treatment Outcome
14.
Ann Vasc Surg ; 62: 365-374, 2020 Jan.
Article in English | MEDLINE | ID: mdl-31560939

ABSTRACT

BACKGROUND: The aim of this study is to assess our experience and mid-term outcomes using Jetstream atherectomy system for treatment of femoropopliteal artery disease (FPAD). METHODS: Data of 30 patients with FPAD treated at our center between 2013 and 2016 were analyzed. Two subgroups of patients were identified: Group A included patients (n = 18) with de novo lesions; Group B (n = 12) included those with in-stent restenosis. The primary study end points assessed were technical success, perioperative mortality, and major adverse event (MAE) rate at 30 days (distal embolization, major amputation, and target lesion revascularization). Other outcomes measured were survival, primary, and secondary patency, and freedom from amputation at 1 and 3 years of follow-up, respectively. RESULTS: Technical success was 100% for both groups. The MAE rate was 8.7%. No distal filter was adopted during intervention. Angioplasty was associated with 93.3% of cases (93.3% vs. 100%; P = 0.15), drug-eluting balloon (DEB) in 12 cases (22.2% vs. 66.6%; P = 0.008), drug-eluting stent and bare metal implantation in 1 (5.6% vs. 0%; P = 1) and 4 cases (11.1% vs. 16.7%; P = 1), respectively. The cumulative primary and secondary patency rates were 75.1% and 95.5% at 1 year, and 70.4% and 84.8% at 3 years of follow-up, respectively. The survival and freedom from amputation were 96.4% and 85.8% at 1 and 3 years of follow-up, respectively. The freedom from target lesion revascularization was 91.7% and 83.4% at 1 and 3 years from intervention. CONCLUSIONS: The use of the Jetstream appears to be safe and feasible with no distal embolization and low rate perioperative complications. Moreover, encouraging outcomes were observed when atherectomy was associated to DEB angioplasty.


Subject(s)
Angioplasty, Balloon , Atherectomy/instrumentation , Femoral Artery , Peripheral Arterial Disease/therapy , Aged , Aged, 80 and over , Amputation, Surgical , Angioplasty, Balloon/adverse effects , Angioplasty, Balloon/instrumentation , Angioplasty, Balloon/mortality , Atherectomy/adverse effects , Atherectomy/mortality , Coated Materials, Biocompatible , Databases, Factual , Drug-Eluting Stents , Equipment Design , Female , Femoral Artery/diagnostic imaging , Femoral Artery/physiopathology , Humans , Italy , Limb Salvage , Male , Middle Aged , Peripheral Arterial Disease/diagnosis , Peripheral Arterial Disease/mortality , Peripheral Arterial Disease/physiopathology , Progression-Free Survival , Retrospective Studies , Risk Factors , Time Factors , Vascular Access Devices , Vascular Patency
15.
J Vasc Surg ; 72(1): 122-128, 2020 07.
Article in English | MEDLINE | ID: mdl-31784279

ABSTRACT

OBJECTIVE: Although the long-term results of endovascular aortic repair (EVAR) with low-profile devices in patients with hostile iliac anatomies have been published, there are no reported results specifically for narrow aortic bifurcations (NAB). This study investigated the outcomes of EVAR with the INCRAFT device in NAB (<16 mm). METHODS: This multicenter retrospective study involved five vascular surgery centers. From November 2014 until June 2018, 127 patients were treated with the INCRAFT device. The patient population was divided into two groups based on aortic bifurcation diameter. They were designated as the (1) standard aortic bifurcation (SAB) group (>16 mm) and the (2) the NAB group (<16 mm). Primary end points were the differences between the two groups in terms of technical success, survival at 30 days, iliac limb patency, and reinterventions. RESULTS: The SAB group included 96 patients and the NAB group included 31 patients. The mean aortic bifurcation diameter was 25.5 mm in the SAB group and 13.2 mm in the NAB group. It is noteworthy that, in the NAB group, 21.8% of patients had aortic bifurcations with focal calcific lesions (less than one-third of the circumferential length of the bifurcation) and 48.3% showed extensive calcifications (two-thirds of the circumferential length of the bifurcation), for 29.9% of the patients in the NAB group the aortic bifurcation had a circumferential highly calcific lesion (complete occlusion of the circumferential length of the bifurcation). Technical success was 98.9% in the SAB group and 96.7% in the NAB group (P = .1). The need for iliac component stenting was not significantly different between the groups (SAB 2.0% vs NAB 3.2%; P = .07). The 1-year survival was 97.9% and 96.7% in the SAB and NAB groups, respectively, with no aneurysm-related mortality. The mean follow-up was 18.4 months and 15.3 months in the SAB and NAB groups, respectively. The iliac primary patency was 98.9 % in the SAB group and 96.8% in the NAB group (P = .088), and the primary assisted patency was 100% in both groups. CONCLUSIONS: EVAR with INCRAFT in NABs showed acceptable results. In this multicenter study, the results were comparable in terms of technical success and iliac patency rate between patients with SABs and NABs.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endovascular Procedures/instrumentation , Iliac Artery/surgery , Stents , Aged , Aged, 80 and over , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/physiopathology , Blood Vessel Prosthesis Implantation/adverse effects , Databases, Factual , Endovascular Procedures/adverse effects , Female , Humans , Iliac Artery/diagnostic imaging , Iliac Artery/physiopathology , Male , Retrospective Studies , Risk Factors , Time Factors , Treatment Outcome , Vascular Patency
16.
J Vasc Surg Cases Innov Tech ; 5(4): 576-579, 2019 Dec.
Article in English | MEDLINE | ID: mdl-31867474

ABSTRACT

A 66-year-old man arrived at our emergency department 3 years after an endovascular aneurysm sealing procedure performed at another center. Computed tomography angiography showed distal migration of a Nellix endoprosthesis (Endologix, Irvine, Calif) and a posterior contained rupture. The left kidney was excluded by an occluded iliac-left renal bypass, which was performed at the time of the Nellix implantation because of unintended coverage. A t-Branch (Cook Medical, Bloomington, Ind) was implanted in an emergency, but the delivery caused disruption of the Nellix limb, requiring relining. Target vessels were bridged with VBX stents (W. L. Gore & Associates, Flagstaff, Ariz). The postoperative course was uneventful except for renal function impairment that was restored 2 weeks later.

17.
Eur J Cardiothorac Surg ; 56(1): 10-20, 2019 Jul 01.
Article in English | MEDLINE | ID: mdl-31102528

ABSTRACT

The number of patients undergoing surgery on the thoracic and thoraco-abdominal aorta has been steadily increasing over the past decade. This document aims to give guidance to authors reporting on results in aortic surgery by clarifying definitions of aortic pathologies, open and endovascular techniques and by listing clinical parameters that should be provided for full presentation of patients' clinical profile and in particular, their outcome. The aim is to help find a common language in the treatment of aortic disease and to contribute to a better understanding of this patient population.


Subject(s)
Aortic Diseases , Cardiac Surgical Procedures , Endovascular Procedures , Manuscripts, Medical as Topic , Thoracic Surgery/organization & administration , Aorta/surgery , Aortic Diseases/diagnostic imaging , Aortic Diseases/epidemiology , Aortic Diseases/surgery , Cardiac Surgical Procedures/classification , Cardiac Surgical Procedures/methods , Comorbidity , Endovascular Procedures/classification , Endovascular Procedures/methods , Humans , Postoperative Complications , Research Design , Risk Factors
18.
Ann Vasc Surg ; 57: 266-271, 2019 May.
Article in English | MEDLINE | ID: mdl-30684615

ABSTRACT

BACKGROUND: The aim of this study is to report the Destino-guided branched endovascular aortic repair approach as a valid alternative to catheterization downward branches in complex aortic arch/descending thoracic anatomies. METHODS & RESULTS: A 53-year-old woman with Marfan syndrome underwent a thoracoabdominal aortic aneurysm (TAAA) repair for a type III dissecting aneurysm. A custom repair with an endograft having 3 fenestrations (for renal arteries and superior mesenteric artery) and 1 branch for the celiac trunk was planned. The right axillary artery was chronically occluded; the left subclavian artery (LSA) was aneurysmatic. The catheterization of the celiac trunk branch was demanding but ultimately a bare stent was used as a bridging component between the graft and the target vessel, for spinal cord preconditioning. At the 2-month computed tomography angiography, when planning the relining of the bare metal stent, a 1 cm increase in diameter of the LSA aneurysm was documented and therefore a Destino-guided branched endovascular aortic repair was planned. This approach consists of branch catheterization via femoral access using the Destino steerable guiding sheath inside which, after bending, a smaller Cook Flexor is placed to easily deliver the stent, while maintaining stability. CONCLUSIONS: The Destino-guided branched endovascular aortic repair is a reproducible and effective alternative to the classic catheterization of side branches via brachial/axillary access allowing their completion from a femoral access.


Subject(s)
Aortic Aneurysm, Thoracic/surgery , Aortic Dissection/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Catheterization, Peripheral/instrumentation , Endovascular Procedures/instrumentation , Femoral Artery , Vascular Access Devices , Aortic Dissection/diagnostic imaging , Aortic Dissection/etiology , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/etiology , Aortography/methods , Blood Vessel Prosthesis , Computed Tomography Angiography , Equipment Design , Female , Femoral Artery/diagnostic imaging , Humans , Marfan Syndrome/complications , Marfan Syndrome/diagnosis , Middle Aged , Punctures , Treatment Outcome
19.
J Vasc Surg ; 69(6): 1655-1663, 2019 Jun.
Article in English | MEDLINE | ID: mdl-30497866

ABSTRACT

OBJECTIVE: Staged endovascular treatment of thoracoabdominal aortic aneurysms (TAAAs) with temporary perfusion of the sac through a branch left unstented or a dedicated branch is a strategy intended to reduce the risk of postoperative spinal cord ischemia (SCI). However, potential complications of this approach are aneurysm sac progression between stages, visceral embolism, and occlusion or displacement of components. We here present the "bare branch" technique, a safe adjunct to TAAA repair in terms of interstage complications. METHODS: In the first step, one branch, preferentially the one for the celiac trunk, is stented by a bare stent; in the second step, the bare branch is relined with a covered stent. There were 32 TAAAs (5 type I, 6 type II, 16 type III, 5 type IV) treated by this approach at our center from January 2015 to December 2017 (median follow-up, 13 months [range, 2-24 months]). Data were prospectively collected and retrospectively analyzed. Primary end points were aneurysm sac exclusion and freedom from major adverse events, which included SCI. Secondary end points were freedom from aneurysm growth between the stages and freedom from minor adverse events. RESULTS: Preoperative mean maximum diameter was 68.4 mm; 32 endografts (8 off-the-shelf and 24 custom-made devices) were used. The mean aortic coverage was 364 mm. The mean interval time between the two stages was 10.5 weeks (range, 7-20 weeks). In-hospital mortality was 0%. Type I or type III endoleak rate was 3.2%, whereas one type II endoleak was registered (3.2%). Two patients showed paraparesis, one after the first stage and one after the second stage, both noted at 4/5 on the Tarlov scale, and fully recovered so that the SCI rate was 6.4% with 0% permanent neurologic deficit. Interstage mean maximum diameter was 68.6 mm (P > .05). After the second step, there was an average of 4.7 spinal arteries (standard deviation, 1.4; P < .05) per patient with an increase in visibility and of diameter by 0.7 mm (standard deviation, 0.4 mm). CONCLUSIONS: This is a reproducible adjunct to staged TAAA endovascular repair. The use of a bare branch instead of a branch left completely open has the clear advantage of an easy catheterization in the second step. Furthermore, by having the target vessel stented with a bare stent, the risk of embolism is avoided. In this experience, there was no significant aneurysm sac growth in between the steps. Further comparative studies may determine whether there are different hemodynamic forces with this technique with respect to those already described in the literature.


Subject(s)
Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis Implantation/methods , Endovascular Procedures/methods , Spinal Cord Ischemia/prevention & control , Aged , Aged, 80 and over , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/physiopathology , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Female , Humans , Male , Middle Aged , Progression-Free Survival , Prosthesis Design , Regional Blood Flow , Retrospective Studies , Risk Factors , Spinal Cord Ischemia/diagnosis , Spinal Cord Ischemia/etiology , Spinal Cord Ischemia/physiopathology , Stents , Time Factors
20.
J Cardiovasc Surg (Torino) ; 60(4): 496-500, 2019 08.
Article in English | MEDLINE | ID: mdl-27145124

ABSTRACT

INTRODUCTION: Aortic dissections classification systems have always been an argument of debate. It is well known that none of the described classifications is complete and easy at the same time. While the more used classification is currently the Stanford classification, it is clear that type A and B dissections prognosis can dramatically vary, depending on many different characteristics that they can present. The aim of this study was to propose a new severity score system that could reflect the risk of in hospital mortality of acute aortic dissections. EVIDENCE ACQUISITION: Through a review of the literature, studies describing significant predictors of in hospital mortality of any type of aortic dissection were searched and selected by predefined selection criteria. EVIDENCE SYNTHESIS: Nine studies met the criteria and were finally analyzed. The Odds Ratios of the reported predictors were the basis to the drawing of the score system. Sixteen main in hospital mortality predictors were found, 14 of which described in more than one study. They were combined into a new severity score system that we named VI2TA2 S2C2ORE. CONCLUSIONS: This is a simple risk score that we propose as a first assessment risk-evaluating tool. We look forward to validate it and to describe specific in hospital mortality risk ranges once it will be adopted.


Subject(s)
Aortic Aneurysm/classification , Aortic Dissection/classification , Aortic Dissection/mortality , Hospital Mortality , Acute Disease , Aortic Aneurysm/mortality , Hospitalization , Humans , Odds Ratio , Prognosis , Risk Factors , Severity of Illness Index