1.
Eye Contact Lens ; 50(3): 126-131, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38345049

ABSTRACT

OBJECTIVES: To report the results of epithelium-off accelerated corneal collagen crosslinking (accelerated corneal crosslinking [ACXL]) in patients with progressive keratoconus. METHODS: This prospective, nonrandomized, noncomparative, interventional, multicenter clinical study included all patients who underwent ACXL, either continuous (c-ACXL; 9 mW/cm 2 , 10', 5.4 J/cm 2 ) or pulsed (p-ACXL; 2″ON/1″OFF, 30 mW/cm 2 , 4.5', 5.4 J/cm 2 ) between January 2014 and May 2017. Best-corrected visual acuity, sphere, cylinder, spherical equivalent, and topographical keratometry data were collected preoperatively and at 1, 3, 6, 12, 18, and 24 months postoperatively. RESULTS: Ninety-six eyes of 78 patients were included. The mean age was 20.8±4.4 years (14-33) for c-ACXL and 26.7±7.7 years (12-37) for p-ACXL. The mean best-corrected visual acuity was 0.4±0.4 for c-ACXL and 0.01±0.1 for p-ACXL preoperatively, and 0.3±0.3 ( P =0.0014) and -0.01±0.1 ( P =0.1554), respectively, at the last follow-up. The subjective sphere and spherical equivalent did not show statistically significant differences between the time points ( P >0.05). The subjective cylinder showed significant differences ( P =0.0013 for c-ACXL; P =0.0358 for p-ACXL). Keratometric values (K steep , K flat , and SimK) remained stable, with no statistically significant differences ( P >0.05). No major complications were noted. CONCLUSIONS: Both c-ACXL and p-ACXL are equally safe and effective ACXL protocols in stabilizing the progression of keratoconus and can be considered alternatives to the conventional Dresden protocol.


Subject(s)
Cross-Linking Reagents , Keratoconus , Adolescent , Adult , Humans , Young Adult , Corneal Topography , Cross-Linking Reagents/therapeutic use , Dilatation, Pathologic , Keratoconus/drug therapy , Prospective Studies
2.
Eye Contact Lens ; 36(5): 245-8, 2010 Sep.
Article in English | MEDLINE | ID: mdl-20724854

ABSTRACT

PURPOSE: To analyze the repeatability of measuring nerve fiber length (NFL) from images of the human corneal subbasal nerve plexus using semiautomated software. METHODS: Images were captured from the corneas of 50 subjects with type 2 diabetes mellitus who showed varying severity of neuropathy, using the Heidelberg Retina Tomograph 3 with Rostock Corneal Module. Semiautomated nerve analysis software was independently used by two observers to determine NFL from images of the subbasal nerve plexus. This procedure was undertaken on two occasions, 3 days apart. RESULTS: The intraclass correlation coefficient values were 0.95 (95% confidence intervals: 0.92-0.97) for individual subjects and 0.95 (95% confidence intervals: 0.74-1.00) for observer. Bland-Altman plots of the NFL values indicated a reduced spread of data with lower NFL values. The overall spread of data was less for (a) the observer who was more experienced at analyzing nerve fiber images and (b) the second measurement occasion. CONCLUSIONS: Semiautomated measurement of NFL in the subbasal nerve fiber layer is highly repeatable. Repeatability can be enhanced by using more experienced observers. It may be possible to markedly improve repeatability when measuring this anatomic structure using fully automated image analysis software.


Subject(s)
Cornea/innervation , Diabetes Mellitus, Type 2/pathology , Nerve Fibers/pathology , Adult , Automation , Humans , Image Processing, Computer-Assisted , Microscopy, Confocal , Severity of Illness Index , Software