Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Scand J Surg ; 105(1): 35-41, 2016 Mar.
Article in English | MEDLINE | ID: mdl-25854823

ABSTRACT

BACKGROUND AND AIMS: In this report, we present our experience with the transaortic transcatheter aortic valve implantation using the SAPIEN valve. The procedural success, 30-day outcome, and survival up to 2 years are compared with the transapical access performed in patients in our institution. MATERIAL AND METHODS: Of a total of 282 transcatheter aortic valve implantation patients, 100 consecutive patients had a non-transfemoral approach. The transaortic and transapical access routes were used in 36 and 64 patients, respectively. The transaortic group had a higher mean logistic EuroSCORE (32.6 vs 25.2, p = 0.021) and more patients with left ventricular ejection fraction less than 40% (33.3% vs 14.1%, p = 0.023). RESULTS: The respective technical success rates for the transaortic and transapical groups were 100% and 95.2% (p = NS). There were significantly more perioperative hemodynamic problems necessitating cardiopulmonary resuscitation or mechanical circulatory support in the transapical group (18.8% vs 2.8%, p = 0.023). The transaortic group had a slightly shorter hospital stay (7 vs 8 days, p = 0.018). The 30-day mortality was 8.6% and 10.9% in the transaortic and transapical group, respectively (p = NS). Combined safety outcome was similar in both groups at 30 days. The respective 1-year survival rates for the transaortic and transapical groups were 71.5% and 68.3%, respectively (p = NS). CONCLUSION: The trans transcatheter aortic valve implantation is a considerable choice to transapical approach. Despite a higher risk patient cohort, the clinical outcome is at least comparable to the transapical transcatheter aortic valve implantation, and it can be utilized as a second choice for patients with prohibitive iliac-femoral anatomy for transfemoral access.


Subject(s)
Aortic Valve Stenosis/surgery , Transcatheter Aortic Valve Replacement/methods , Aged , Aged, 80 and over , Aortic Valve Stenosis/mortality , Female , Follow-Up Studies , Heart Valve Prosthesis , Humans , Logistic Models , Male , Retrospective Studies , Survival Rate , Transcatheter Aortic Valve Replacement/instrumentation , Treatment Outcome
2.
Rev Sci Instrum ; 79(3): 033302, 2008 Mar.
Article in English | MEDLINE | ID: mdl-18377002

ABSTRACT

High performance electron cyclotron resonance (ECR) ion sources, such as VENUS (Versatile ECR for NUclear Science), produce large amounts of x-rays. By studying their energy spectra, conclusions can be drawn about the electron heating process and the electron confinement. In addition, the bremsstrahlung from the plasma chamber is partly absorbed by the cold mass of the superconducting magnet, adding an extra heat load to the cryostat. Germanium or NaI detectors are generally used for x-ray measurements. Due to the high x-ray flux from the source, the experimental setup to measure bremsstrahlung spectra from ECR ion sources is somewhat different from that for the traditional nuclear physics measurements these detectors are generally used for. In particular, the collimation and background shielding can be problematic. In this paper, we will discuss the experimental setup for such a measurement, the energy calibration and background reduction, the shielding of the detector, and collimation of the x-ray flux. We will present x-ray energy spectra and cryostat heating rates depending on various ion source parameters, such as confinement fields, minimum B-field, rf power, and heating frequency.

3.
Rev Sci Instrum ; 79(2 Pt 2): 02A303, 2008 Feb.
Article in English | MEDLINE | ID: mdl-18315093

ABSTRACT

The increased requirements towards the use of higher ion beam intensities motivated us to initiate the project to improve the overall transmission of the K130 cyclotron facility. With the facility the transport efficiency decreases rapidly as a function of total beam intensity extracted from the JYFL ECR ion sources. According to statistics, the total transmission efficiency is of the order of 10% for low beam intensities (I(total)< or =0.7 mA) and only about 2% for high beam intensities (I(total)>1.5 mA). Requirements towards the use of new metal ion beams for the nuclear physics experiments have also increased. The miniature oven used for the production of metal ion beams at the JYFL is not able to reach the temperature needed for the requested metal ion beams. In order to fulfill these requirements intensive development work has been performed. An inductively and a resistively heated oven has successfully been developed and both are capable of reaching temperatures of about 2000 degrees C. In addition, sputtering technique has been tested. GEANT4 simulations have been started in order to better understand the processes involved with the bremsstrahlung, which gives an extra heat load to cryostat in the case of superconducting ECR ion source. Parallel with this work, a new advanced ECR heating simulation program has been developed. In this article we present the latest results of the above-mentioned projects.

SELECTION OF CITATIONS
SEARCH DETAIL
...