Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
IEEE Trans Biomed Eng ; 60(9): 2401-10, 2013 Sep.
Article in English | MEDLINE | ID: mdl-23591468

ABSTRACT

Magnetic resonance (MR) cystography or MR-based virtual cystoscopy is a promising new technology to evaluate the entire bladder in a fully noninvasive manner. It requires the anatomical bladder images be acquired at high spatial resolution and with adequate signal-to-noise ratio (SNR). This often leads to a long-time scan (>5 min) and results in image artifacts due to involuntary bladder motion and deformation. In this paper, we investigated an image-processing approach to mitigate the problem of motion and deformation. Instead of a traditional single long-time scan, six repeated short-time scans (each of approximately 1 min) were acquired for the purpose of shifting bladder motion from intrascan into interscans. Then, the interscan motions were addressed by registering the short-time scans to a selected reference and finally forming a single average motion-corrected image. To evaluate the presented approach, three types of images were generated: 1) the motion-corrected image by registration and average of the short-time scans; 2) the directly averaged image of the short-time scans (without motion correction); and 3) the single image of the corresponding long-time scan. Six experts were asked to blindly score these images in terms of two important aspects: 1) the definition of the bladder wall and 2) the overall expression on the image quality. Statistical analysis on the scores suggested that the best result in both the aspects is achieved by the presented motion-corrected average. Furthermore, the superiority of the motion-corrected average over the other two is statistically significant by the measure of a linear mixed-effect model with p -values < 0.05. Our findings may facilitate the detection of bladder abnormality in MR cystography by mitigating the motion challenge. The effectiveness of this approach depends on the noise level of acquired short-time scans and the robustness of image registration, and future effort on these two aspects is needed.


Subject(s)
Cystoscopy/methods , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Adult , Algorithms , Humans , Observation , Signal-To-Noise Ratio , Urinary Bladder/anatomy & histology , Urinary Bladder/ultrastructure
2.
J Pediatr Endocrinol Metab ; 22(9): 859-62, 2009 Sep.
Article in English | MEDLINE | ID: mdl-19960896

ABSTRACT

Ectopic posterior pituitary hyperintensity on MRI is a common feature associated with growth hormone deficiency. The presence of at least some residual components of the pituitary stalk is necessary for adequate anterior pituitary function. Little is known about long-term change in pituitary function or MRI findings in patients with ectopic posterior pituitary and interrupted pituitary stalk. We describe a case of childhood growth hormone deficiency and hyperprolactinemia associated with absent pituitary stalk. As an adult, prolactin levels normalized and GH secretion improved associated with changes in MRI findings.


Subject(s)
Aging/physiology , Growth Disorders/rehabilitation , Human Growth Hormone/deficiency , Pituitary Gland/physiology , Adult , Brain Diseases/physiopathology , Child , Child Development/drug effects , Child Development/physiology , Choristoma/physiopathology , Female , Growth Disorders/drug therapy , Growth Disorders/etiology , Growth Disorders/physiopathology , Human Growth Hormone/therapeutic use , Humans , Hyperprolactinemia/drug therapy , Hyperprolactinemia/etiology , Hyperprolactinemia/physiopathology , Hyperprolactinemia/rehabilitation , Pituitary Gland/abnormalities
SELECTION OF CITATIONS
SEARCH DETAIL
...