Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Phys Rev Lett ; 109(4): 045001, 2012 Jul 27.
Article in English | MEDLINE | ID: mdl-23006093

ABSTRACT

A significant fraction of high-harmonic fast-wave (HHFW) power applied to NSTX can be lost to the scrape-off layer (SOL) and deposited in bright and hot spirals on the divertor rather than in the core plasma. We show that the HHFW power flows to these spirals along magnetic field lines passing through the SOL in front of the antenna, implying that the HHFW power couples across the entire width of the SOL rather than mostly at the antenna face. This result will help guide future efforts to understand and minimize these edge losses in order to maximize fast-wave heating and current drive.

2.
Rev Sci Instrum ; 81(10): 10E502, 2010 Oct.
Article in English | MEDLINE | ID: mdl-21034030

ABSTRACT

A novel diagnostic design seeks to enhance the capability of multienergy soft x-ray (SXR) detection by using an image intensifier to amplify the signals from a larger set of filtered x-ray profiles. The increased number of profiles and simplified detection system provides a compact diagnostic device for measuring T(e) in addition to contributions from density and impurities. A single-energy prototype system has been implemented on NSTX, comprised of a filtered x-ray pinhole camera, which converts the x-rays to visible light using a CsI:Tl phosphor. SXR profiles have been measured in high performance plasmas at frame rates of up to 10 kHz, and comparisons to the toroidally displaced tangential multi-energy SXR have been made.

3.
Phys Rev Lett ; 104(9): 095003, 2010 Mar 05.
Article in English | MEDLINE | ID: mdl-20366991

ABSTRACT

Transient coaxial helicity injection (CHI) started discharges in the National Spherical Torus Experiment (NSTX) have attained peak currents up to 300 kA and when coupled to induction, it has produced up to 200 kA additional current over inductive-only operation. CHI in NSTX has shown to be energetically quite efficient, producing a plasma current of about 10 A/J of capacitor bank energy. In addition, for the first time, the CHI-produced toroidal current that couples to induction continues to increase with the energy supplied by the CHI power supply at otherwise similar values of the injector flux, indicating the potential for substantial current generation capability by CHI in NSTX and in future toroidal devices.

4.
Rev Sci Instrum ; 79(10): 10E318, 2008 Oct.
Article in English | MEDLINE | ID: mdl-19044480

ABSTRACT

We describe upgrades to a compact grazing-incidence spectrometer utilized on the National Spherical Torus Experiment for monitoring light and heavy impurities. A fast-readout charge couple device camera has been implemented that allows the recording of spectra with up to 25 ms time integration. This capability is used to study the time evolution of the K-shell emission of hydrogenlike and heliumlike boron, carbon, nitrogen, and oxygen between 10 and 65 A. Different camera positioning pieces have been employed to extend the possible spectral range to as high as 140. Several lines that cannot be ascribed to the usual elements found in the plasma have been observed in this spectral range, although often only in a few isolated discharges.

5.
Appl Opt ; 46(24): 6069-75, 2007 Aug 20.
Article in English | MEDLINE | ID: mdl-17712368

ABSTRACT

Scintillator-based "optical" soft x-ray (OSXR) arrays have been investigated as a replacement for the conventional silicon (Si)-based diode arrays used for imaging, tomographic reconstruction, magnetohydrodynamics, transport, and turbulence studies in magnetically confined fusion plasma research. An experimental survey among several scintillator candidates was performed, measuring the relative and absolute conversion efficiencies of soft x rays to visible light. Further investigations took into account glass and fiber-optic face-plates (FOPs) as substrates, and a thin aluminum foil (150 nm) to reflect the visible light emitted by the scintillator back to the optical detector. Columnar (crystal growth) thallium-doped cesium iodide (CsI:Tl) deposited on an FOP, was found to be the best candidate for the previously mentioned plasma diagnostics. Its luminescence decay time of the order of approximately 1-10 micros is thus suitable for the 10 micros time resolution required for the development of scintillator-based SXR plasma diagnostics. A prototype eight channel OSXR array using CsI:Tl was designed, built, and compared to an absolute extreme ultraviolet diode counterpart: its operation on the National Spherical Torus Experiment showed a lower level of induced noise relative to the Si-based diode arrays, especially during neutral beam injection heated plasma discharges. The OSXR concept can also be implemented in less harsh environments for basic spectroscopic laboratory plasma diagnostics.

6.
Phys Rev Lett ; 91(26 Pt 1): 265001, 2003 Dec 31.
Article in English | MEDLINE | ID: mdl-14754058

ABSTRACT

Dielectronic satellite spectra of heliumlike argon, recorded with a high-resolution x-ray crystal spectrometer at the National Spherical Torus Experiment, were found to be inconsistent with existing predictions resulting in unacceptable values for the power balance and suggesting the unlikely existence of non-Maxwellian electron energy distributions. These problems were resolved with calculations from a new atomic code. It is now possible to perform reliable electron-temperature measurements and to eliminate the uncertainties associated with determinations of non-Maxwellian distributions.

SELECTION OF CITATIONS
SEARCH DETAIL
...