Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Genes (Basel) ; 14(10)2023 09 22.
Article in English | MEDLINE | ID: mdl-37895187

ABSTRACT

Keratoconus is a corneal dystrophy that is one of the main causes of corneal transplantation and for which there is currently no effective treatment for all patients. The presentation of this disease in pediatric age is associated with rapid progression, a worse prognosis and, in 15-20% of cases, the need for corneal transplantation. It is a multifactorial disease with genetic variability, which makes its genetic study difficult. Discovering new therapeutic targets is necessary to improve the quality of life of patients. In this manuscript, we present the results of whole-exome sequencing (WES) of 24 pediatric families diagnosed at the University Hospital La Paz (HULP) in Madrid. The results show an oligogenic inheritance of the disease. Genes involved in the structure, function, cell adhesion, development and repair pathways of the cornea are proposed as candidate genes for the disease. Further studies are needed to confirm the involvement of the candidate genes described in this article in the development of pediatric keratoconus.


Subject(s)
Corneal Dystrophies, Hereditary , Keratoconus , Humans , Child , Keratoconus/genetics , Keratoconus/diagnosis , Exome Sequencing , Quality of Life , Cornea
2.
Int J Mol Sci ; 23(8)2022 Apr 11.
Article in English | MEDLINE | ID: mdl-35457050

ABSTRACT

Early-onset high myopia (EoHM) is a disease that causes a spherical refraction error of ≥-6 diopters before 10 years of age, with potential multiple ocular complications. In this article, we report a clinical and genetic study of 43 families with EoHM recruited in our center. A complete ophthalmological evaluation was performed, and a sample of peripheral blood was obtained from proband and family members. DNA was analyzed using a customized next-generation sequencing panel that included 419 genes related to ophthalmological disorders with a suspected genetic cause, and genes related to EoHM pathogenesis. We detected pathogenic and likely pathogenic variants in 23.9% of the families and detected variants of unknown significance in 76.1%. Of these, 5.7% were found in genes related to non-syndromic EoHM, 48.6% in genes associated with inherited retinal dystrophies that can include a syndromic phenotype, and 45.7% in genes that are not directly related to EoHM or retinal dystrophy. We found no candidate genes in 23% of the patients, which suggests that further studies are needed. We propose a systematic genetic analysis for patients with EoHM because it helps with follow-up, prognosis and genetic counseling.


Subject(s)
Myopia , Retinal Dystrophies , DNA Mutational Analysis , High-Throughput Nucleotide Sequencing , Humans , Mutation , Myopia/diagnosis , Myopia/genetics , Pedigree , Retinal Dystrophies/genetics
3.
J Drug Assess ; 9(1): 66-71, 2020.
Article in English | MEDLINE | ID: mdl-32341839

ABSTRACT

Purpose: To describe a standardized protocol of the dexamethasone intravitreal (DEX) implant Ozurdex (Allergan, Dublin, Ireland) performed in a controlled environment surgical cabin (CESC). Methods: Retrospective and observational study conducted on patients who underwent a DEX implant between May 2011 and June 2019, in a third level University Hospital. The controlled environment surgical cabin (ArcSterile, Imex, Valencia, Spain) used in this study was the MB 20 (2 m width, 1.60 m depth, and 2 m height) with an uninterrupted power system (ARSSAI1) to keep the cabin working for 20 min. The cabin was used in the open mode. A standardized protocol of intravitreal injections in controlled environment surgical cabin was designed. Results: From May 2011 to February 2015, a total of 454 DEX implants were performed in the operating room, whereas from March 2015 to June 2019, 1054 DEX devices were implanted using the CESC. The mean number of DEX implants/per week was significantly lower in the operating room than in the CESC [2.3 (2.1 to 2.5) versus 3.8 (3.6 to 4.1), mean difference 1.5 (1.2 to 1.8), p < 0.0001]. The incidence of endophthalmitis was similar in the two populations, 0/454 (0.0%; 95% CI 0.0 to 0.81%) and 0/1054 (0.0%; 95% CI 0.0 to 0.35%) in the operating room and in the CESC, respectively. Conclusions: The CESC may be a good alternative to the conventional operating room for the administration of the intravitreal DEX implant.

SELECTION OF CITATIONS
SEARCH DETAIL
...