Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
Neurourol Urodyn ; 39(3): 987-993, 2020 03.
Article in English | MEDLINE | ID: mdl-32125722

ABSTRACT

AIMS: To comparatively analyse outcomes after ARGUS classic and ArgusT adjustable male sling implantation in a real-world setting. METHODS: Inclusion criteria encompassed: non-neurogenic, moderate-to-severe stress urinary incontinence (≥2 pads), implantation of an ARGUS classic or ArgusT male sling between 2010 and 2012 in a high-volume center (>150 previous implantations). Functional outcomes were assessed using daily pad usage, 24-hour pad testing, and International Consultation on Incontinence (ICIQ-SF) questionnaires. Continence was defined as zero pads per 24 hours. Complications were graded using Clavien-Dindo scale. For multivariate analysis, binary logistic regression models were used (P < .05). RESULTS: A total of 106 patients (n = 74 [ARGUS classic], n = 32 [ArgusT]) from four centers were eligible. Median follow-up was 44.0 months (24-64). Patient cohorts were well-balanced. We observed a statistical trend in favor of ARGUS classic regarding postoperative urine loss based on standardized 24-hour pad test (71 ± 162 g [ARGUS classic] vs 160 ± 180 g [ArgusT]); P = .066]. Dry rates were 33.3% (ARGUS classic) and 11.8% (ArgusT, P = .114). In multivariable analysis, ArgusT male sling could not be confirmed as an independent predictor of decreased success (OR, 0.587; 95% CI; 0.166-2.076, P = .408). There were no Clavien IV and V complications. Inguinal pain was significantly higher after ArgusT implantation (P = .033). Explantation rates were higher for ArgusT compared to ARGUS classic (14.0 vs 23.3%; P = .371). Longer device survival for the ARGUS classic male sling was observed in Kaplan-Meier analysis (P = .198). CONCLUSIONS: In the largest comparative analysis of ARGUS classic and ArgusT male sling with the longest follow-up to date, we observed low continence rates with superior functional outcomes and decreased explantation rates after ARGUS classic implantation.


Subject(s)
Device Removal/statistics & numerical data , Postoperative Complications/surgery , Prostatectomy , Suburethral Slings , Urinary Incontinence, Stress/surgery , Urologic Surgical Procedures, Male/methods , Aged , Humans , Male , Middle Aged , Postoperative Complications/epidemiology , Surveys and Questionnaires , Treatment Outcome , Urologic Surgical Procedures, Male/instrumentation
2.
Adv Exp Med Biol ; 875: 755-62, 2016.
Article in English | MEDLINE | ID: mdl-26611029

ABSTRACT

Acoustic monitoring of harbor porpoises (Phocoena phocoena L., 1758) indicated a strongly reduced disturbance by noise emitted by pile driving for offshore wind turbine foundations insulated by a big bubble curtain (BBC). This newly developed noise mitigation system was tested during construction of the offshore wind farm Borkum West II (North Sea). Because porpoise activity strongly corresponded to the sound level, operation of the new system under its most suitable configuration reduced the porpoise disturbance area by ~90%. Hence, for the first time, a positive effect of a noise mitigation system during offshore pile driving on an affected marine mammal species could be demonstrated.


Subject(s)
Aquatic Organisms/physiology , Noise/prevention & control , Phocoena/physiology , Animals , Energy-Generating Resources
SELECTION OF CITATIONS
SEARCH DETAIL