Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Anal Biochem ; 492: 27-9, 2016 Jan 01.
Article in English | MEDLINE | ID: mdl-26410338

ABSTRACT

The occurrence of boar taint and the European Commission recommendation to discontinue the surgical castration of pigs by the year 2018 creates an urgent need for new analytical methods that are simple, affordable, and suitable for field testing. We describe the generation and engineering of a skatole-specific antibody derived from a synthetic antibody library and the development of ELISA for its detection. The immunoassay is capable of detecting skatole with IC50 of 222 µg L(-1), which is within the analytical threshold level suggested for skatole, and with low cross-reactivity interference from other indolic compounds.


Subject(s)
Chemistry Techniques, Analytical/methods , Enzyme-Linked Immunosorbent Assay , Single-Chain Antibodies/immunology , Skatole/analysis , Animals , Indoles/chemistry , Indoles/immunology , Male , Odorants/analysis , Single-Chain Antibodies/genetics , Single-Chain Antibodies/metabolism , Skatole/immunology , Swine
2.
Anal Chem ; 83(23): 9011-6, 2011 Dec 01.
Article in English | MEDLINE | ID: mdl-22070371

ABSTRACT

We have developed switchable lanthanide luminescence-based binary probe technology for homogeneous detection of avidin, which is a tetrameric protein. Two different nonluminescent label moieties--a light-absorbing antenna ligand and a lanthanide ion carrier chelate--were conjugated to separate biotins, which is known as avidin's natural ligand. The assay was based on binding of the two differently labeled biotins on separate binding sites on the target protein and consequent self-assembly of a luminescent complex from the two label moieties. Specific luminescence signal was observed only at the presence of the target protein. The characteristics of the switchable lanthanide luminescence assay were compared to the reference assay, based on lanthanide resonance energy transfer. Both assays had a limit of detection in the low-picomolar concentration range; however, the lanthanide chelate complementation-based assay had wider dynamic range and its optimization was more straightforward. The switchable lanthanide luminescence technology could be further applied to generic protein detection, using reagents that are analogous to the proximity ligation assay principle.


Subject(s)
Avidin/analysis , Lanthanoid Series Elements/chemistry , Luminescent Measurements , Binding Sites , Biotin/chemistry , Biotin/metabolism , Fluorescence Resonance Energy Transfer
3.
Anal Chem ; 78(13): 4690-6, 2006 Jul 01.
Article in English | MEDLINE | ID: mdl-16808483

ABSTRACT

We recently described a novel homogeneous assay principle based on upconversion fluorescence resonance energy transfer (UC-FRET), where an upconverting phosphor (UCP) is utilized as a donor. The UC-FRET has now been applied to a competitive homogeneous immunoassay for 17beta-estradiol (E2) in serum, using a small-molecular dye as an acceptor. The assay was constructed by employing an UCP coated with an E2-specific recombinant antibody Fab fragment as a donor and an E2-conjugated small-molecular dye, Oyster-556, as an acceptor. Standard curves for the assay were produced both in buffer and in male serum. Sensitized acceptor emission was measured at 600 nm under continuous laser diode excitation at 980 nm. In buffer, the IC50 value of the assay was 1 nM and in serum 3 nM. The lower limits of detection (mean of zero calibrators, 3 SD) were 0.4 and 0.9 nM, respectively. The measurable concentration range extended up to 3 nM in buffer and 9 nM in serum. Equilibrium in the assay was reached in 30 min. The novel principle of UC-FRET has unique advantages compared to present homogeneous luminescence-based methods and can enable an attractive assay system platform for clinical diagnostics and for high-throughput screening approaches.


Subject(s)
Estradiol/analysis , Immunoassay/methods , Fluorescence Resonance Energy Transfer , Kinetics
4.
Anal Biochem ; 331(2): 376-84, 2004 Aug 15.
Article in English | MEDLINE | ID: mdl-15265745

ABSTRACT

Streptavidin-coated microtitration plates have an important role as a solid phase in clinical diagnostics. We have designed techniques for evaluating quantitative and functional aspects of streptavidin adsorbed in microtitration wells. The theoretical monolayer adsorption capacity was modeled based on the molecular dimensions of the protein. Adsorbed streptavidin was quantified by direct labeling of protein with terbium chelate and with a sensitive bicinchoninic acid-based protein assay. A new small molecular weight (1037Da) reporter molecule, a europium-labeled biotin (Eu-biotin), was synthesized and used for monitoring adsorption and for determination of biotin-binding capacities of the streptavidin-coated wells. The theoretical monolayer adsorption of streptavidin yielded 6.20 pmol/cm(2) (370 ng) and consequently the theoretical adsorption capacity of a C12-format microtitration well (200 microl liquid, coated area 1.54 cm(2)) was 9.55 pmol/well (570 ng). Adsorption properties of streptavidin from two suppliers were tested, one of which yielded 350-380 ng/well while the other yielded over 500 ng/well. The biotin binding capacities were about 11 and 14 pmol/well, respectively. We managed to quantify surface-adsorbed streptavidin with sensitive fluorescence and protein measurement methods in the microtitration well. The new Eu-biotin reporter molecule enabled an exact and convenient determination of the biotin-binding capacities of streptavidin surfaces.


Subject(s)
Streptavidin/chemistry , Adsorption , Fluorescence , Sensitivity and Specificity
5.
Anal Chem ; 75(13): 3193-201, 2003 Jul 01.
Article in English | MEDLINE | ID: mdl-12964769

ABSTRACT

New labels and assay techniques are needed to improve the sensitivity and quantitativeness of point-of-care immunotesting while sustaining the rapidity and ease of use of the assays. We synthesized a novel, intrinsically fluorescent nonadentate europium chelate with two chromophores and hydrophilic alpha-galactose side groups. The chelate is highly fluorescent, soluble in water, and provides effective shielding of Eu from water. The performance of the nonadentate chelate was compared with a heptadentate chelate in a dry reagent immunoassay for human chorionic gonadotropin (hCG). After 15-min incubation and washing, time-resolved fluorescence was measured directly from a wet or dried well surface. Contrary to the heptadentate label, the effect of aqueous quenching on the nonadentate label was found to be insignificant, with calculated analytical detection limits (background + 3 SD) of 0.9 and 0.7 IU/L hCG for wet and dry measurements, respectively, and a linear range up to 5000 IU/L. The CVs for the new label were <8% at the cutoff of 25 IU/L and above in both whole blood and plasma. The novel nonadentate label facilitates short turnaround times and simple instrumentation due to the absence of all signal development steps, at the same time retaining an excellent immunoassay performance.


Subject(s)
Chelating Agents/chemistry , Europium/chemistry , Fluorescent Dyes/chemistry , Immunoassay/methods , Point-of-Care Systems , Chorionic Gonadotropin/blood , Fluorometry/methods , Humans , Male , Reproducibility of Results , Sensitivity and Specificity
6.
Protein Eng ; 16(1): 37-46, 2003 Jan.
Article in English | MEDLINE | ID: mdl-12646691

ABSTRACT

Sulfa-antibiotics (sulfonamides) are widely used in veterinary medicine. Meat and milk from treated animals can be contaminated with sulfa residues. Current sulfonamide assays are unfit for screening of food, because they are either too laborious, insensitive or specific for a few sulfa compounds only. An immunoassay for detection of all sulfas in a single reaction would be useful for screening. Previously we have improved the broad specificity sulfa binding of antibody 27G3 with random mutagenesis and phage display. In order to improve the properties of this antibody further, mutants from the previous study were recombined and more mutations introduced. These new libraries were enriched with phage display and several different mutant antibodies were isolated. The cross-reaction profile of the best mutant was better than that of the wild-type antibody and the mutants of the previous study: it was capable of binding 10 of the tested 13 sulfonamides within a narrow concentration range and also bound the rest of the sulfas 5- to 11-fold better than the mutants of the previous study.


Subject(s)
Haptens/genetics , Haptens/metabolism , Sulfonamides/analysis , Amino Acid Sequence , Antibody Specificity , Bacteriophage M13/chemistry , Bacteriophage M13/genetics , Binding, Competitive , Cloning, Molecular , DNA Shuffling , Escherichia coli/metabolism , Haptens/chemistry , Immunoassay , Molecular Sequence Data , Mutagenesis, Site-Directed , Peptide Library , Plasmids/genetics , Polymerase Chain Reaction/methods , Sulfonamides/chemistry , Sulfonamides/metabolism , Viral Fusion Proteins/chemistry , Viral Fusion Proteins/genetics , Viral Fusion Proteins/metabolism
7.
J Agric Food Chem ; 50(15): 4194-201, 2002 Jul 17.
Article in English | MEDLINE | ID: mdl-12105945

ABSTRACT

Sulfa antibiotics (sulfonamides) are derivatives of p-aminobenzenesulfonamide that are widely used in veterinary medicine. Foods derived from treated animals may be contaminated with these drugs. However, current immunobased sulfonamide detection methods are unfit for screening of products because they are either too insensitive or specific for a few compounds only. An immunoassay capable of detecting all sulfas in a single reaction would be ideal for screening. For development of a binder capable of binding all sulfas, a protein engineering approach was chosen and the properties of monoclonal antibody 27G3 were improved with mutagenesis followed by selection with phage display. Several different mutant antibodies were isolated. The cross-reaction profile of the best mutant antibody was significantly improved over that of the wild-type antibody: it was capable of binding 9 of the tested 13 sulfonamides within a narrow concentration range and also bound the rest of the sulfas, albeit within a wider concentration range.


Subject(s)
Antibodies, Monoclonal/genetics , Haptens , Immunoassay , Protein Engineering , Sulfonamides/analysis , Antibodies, Monoclonal/chemistry , Antibodies, Monoclonal/immunology , Antibody Specificity , Cloning, Molecular , Food Contamination , Genetic Vectors , Meat/analysis , Mutagenesis , Peptide Library , Plasmids , Polymerase Chain Reaction , Sensitivity and Specificity , Veterinary Medicine
SELECTION OF CITATIONS
SEARCH DETAIL
...