Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
JAMA Otolaryngol Head Neck Surg ; 148(10): 940-946, 2022 10 01.
Article in English | MEDLINE | ID: mdl-36048465

ABSTRACT

Importance: Nasal valve collapse is a primary cause of nasal airway obstruction (NAO). Patients with NAO and nasal valve collapse experience a variety of symptoms that lower their quality of life, such as nasal congestion, headache, sleep disturbance, daytime sleepiness, and snoring. Objective: To determine if active treatment of the nasal valve with a temperature-controlled radiofrequency (TCRF) device, previously demonstrated superior to a sham procedure at 3 months, was safe and associated with sustained improvements in symptoms of NAO through 12 months. Design, Setting, and Participants: In a prospective, multicenter, single-blinded, randomized clinical trial, patients in 16 centers in the US with index procedures between August and December 2020 were assigned to TCRF device treatment of the nasal valve or a sham control procedure (no RF energy). Patients had a baseline Nasal Obstruction Symptom Evaluation (NOSE) Scale score of 55 or greater with nasal valve collapse as the primary or substantial contributor to NAO. After primary end point evaluation at 3 months, eligible patients in the sham control arm crossed over to active treatment. Data analysis was performed between April and May 2022. Interventions: Patients were treated bilaterally with the TCRF device at 4 or fewer nonoverlapping areas on the nasal mucosa at the junction of the upper and lower lateral cartilage on the lateral nasal wall. Main Outcomes and Measures: The primary end point measure was responder rate, defined as 20% or greater reduction in NOSE Scale score or 1 or greater reduction in NOSE Scale clinical severity category. Results: A total of 108 patients received active treatment (77 as index active treatment, 31 after crossover). The mean (SD) age of patients was 48.5 (12.3) years; 66 (61.1%) were women. The combined group of patients receiving active treatment had a mean baseline NOSE Scale score of 76.3 (95% CI, 73.6-79.1). At 12 months (n = 88), the responder rate was 89.8% (95% CI, 81.7%-94.5%). The NOSE Scale score improved from baseline (mean change, -44.9 [95% CI, -52.1 to -37.7]). No device/procedure-related serious adverse events were reported. Conclusions and Relevance: In this follow-up of a cohort from a randomized clinical trial, the minimally invasive TCRF device, previously demonstrated to be superior to a sham procedure, was safe and associated with improvement in symptoms of NAO through 12 months postprocedure. Trial Registration: ClinicalTrials.gov Identifier: NCT04549545.


Subject(s)
Nasal Obstruction , Female , Humans , Male , Middle Aged , Nasal Obstruction/complications , Nasal Obstruction/surgery , Prospective Studies , Quality of Life , Temperature , Treatment Outcome
2.
Int Forum Allergy Rhinol ; 11(12): 1676-1684, 2021 12.
Article in English | MEDLINE | ID: mdl-34240571

ABSTRACT

BACKGROUND: Nasal valve collapse is one of several causes of nasal obstruction. The safety and efficacy of a temperature-controlled radiofrequency (RF) device for the treatment of the nasal valve for nasal airway obstruction (NAO) has been established in single-arm studies. The objective of this trial was to compare active device treatment against a sham procedure (control). METHODS: In a prospective, multicenter, single-blinded, randomized controlled trial (RCT), patients were assigned to bilateral temperature-controlled RF treatment of the nasal valve (n = 77) or a sham procedure (n = 41), in which no RF energy was transferred to the device/treatment area. The device was applied to the mucosa over the lower lateral cartilage on the lateral nasal wall. The primary endpoint was responder rate at 3 months, defined as a ≥20% reduction in Nasal Obstruction Symptom Evaluation (NOSE)-scale score or ≥1 reduction in clinical severity category. RESULTS: At baseline, patients had a mean NOSE-scale score of 76.7 (95% confidence interval [CI], 73.8 to 79.5) and 78.8 (95% CI, 74.2 to 83.3) (p = 0.424) in the active treatment and sham-control arms, respectively. At 3 months, the responder rate was significantly higher in the active treatment arm (88.3% [95% CI, 79.2%-93.7%] vs 42.5% [95% CI, 28.5%-57.8%]; p < 0.001). The active treatment arm had a significantly greater decrease in NOSE-scale score (mean, -42.3 [95% CI, -47.6 to -37.1] vs -16.8 [95% CI, -26.3 to -7.2]; p < 0.001). Three adverse events at least possibly related to the device and/or procedure were reported, and all resolved. CONCLUSION: This RCT shows temperature-controlled RF treatment of the nasal valve is safe and effective in reducing symptoms of NAO in short-term follow-up.


Subject(s)
Nasal Obstruction , Humans , Nasal Obstruction/surgery , Nose , Prospective Studies , Temperature , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL