Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Phys Med ; 123: 103394, 2024 Jun 08.
Article in English | MEDLINE | ID: mdl-38852364

ABSTRACT

PURPOSE: To present the results of the first multi-centre real-world validation of autoplanning for whole breast irradiation after breast-sparing surgery, encompassing high complexity cases (e.g. with a boost or regional lymph nodes) and a wide range of clinical practices. METHODS: The 24 participating centers each included 10 IMRT/VMAT/Tomotherapy patients, previously treated with a manually generated plan ('manplan'). There were no restrictions regarding case complexity, planning aims, plan evaluation parameters and criteria, fractionation, treatment planning system or treatment machine/technique. In addition to dosimetric comparisons of autoplans with manplans, blinded plan scoring/ranking was conducted by a clinician from the treating center. Autoplanning was performed using a single configuration for all patients in all centres. Deliverability was verified through measurements at delivery units. RESULTS: Target dosimetry showed comparability, while reductions in OAR dose parameters were 21.4 % for heart Dmean, 16.7 % for ipsilateral lung Dmean, and 101.9 %, 45.5 %, and 35.7 % for contralateral breast D0.03cc, D5% and Dmean, respectively (all p < 0.001). Among the 240 patients included, the clinicians preferred the autoplan for 119 patients, with manplans preferred for 96 cases (p = 0.01). Per centre there were on average 5.0 ± 2.9 (1SD) patients with a preferred autoplan (range [0-10]), compared to 4.0 ± 2.7 with a preferred manplan ([0,9]). No differences were observed regarding deliverability. CONCLUSION: The automation significantly reduced the hands-on planning workload compared to manual planning, while also achieving an overall superiority. However, fine-tuning of the autoplanning configuration prior to clinical implementation may be necessary in some centres to enhance clinicians' satisfaction with the generated autoplans.

2.
Phys Med ; 32(12): 1659-1666, 2016 Dec.
Article in English | MEDLINE | ID: mdl-27765457

ABSTRACT

PURPOSE: To predict patients who would benefit from adaptive radiotherapy (ART) and re-planning intervention based on machine learning from anatomical and dosimetric variations in a retrospective dataset. MATERIALS AND METHODS: 90 patients (pts) treated for head-neck cancer (H&N) formed a multicenter data-set. 41 H&N pts (45.6%) were considered for learning; 49 pts (54.4%) were used to test the tool. A homemade machine-learning classifier was developed to analyze volume and dose variations of parotid glands (PG). Using deformable image registration (DIR) and GPU, patients' conditions were analyzed automatically. Support Vector Machines (SVM) was used for time-series evaluation. "Inadequate" class identified patients that might benefit from replanning. Double-blind evaluation by two radiation oncologists (ROs) was carried out to validate day/week selected for re-planning by the classifier. RESULTS: The cohort was affected by PG mean reduction of 23.7±8.8%. During the first 3weeks, 86.7% cases show PG deformation aligned with predefined tolerance, thus not requiring re-planning. From 4th week, an increased number of pts would potentially benefit from re-planning: a mean of 58% of cases, with an inter-center variability of 8.3%, showed "inadequate" conditions. 11% of cases showed "bias" due to DIR and script failure; 6% showed "warning" output due to potential positioning issues. Comparing re-planning suggested by tool with recommended by ROs, the 4th week seems the most favorable time in 70% cases. CONCLUSIONS: SVM and decision-making tool was applied to overcome ART challenges. Pts would benefit from ART and ideal time for re-planning intervention was identified in this retrospective analysis.


Subject(s)
Machine Learning , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Computer-Assisted/methods , Cohort Studies , Humans , Reproducibility of Results , Retrospective Studies
3.
Phys Rev E Stat Nonlin Soft Matter Phys ; 64(2 Pt 1): 021203, 2001 Aug.
Article in English | MEDLINE | ID: mdl-11497568

ABSTRACT

Quantum effects in the teraherz dynamics of supercritical 4He have been studied as a function of both density rho and temperature T; they have been characterized through their effects on the second and third spectral moments of the dynamic structure factor S(Q, omega), measured by the inelastic x-ray scattering (IXS) technique. The IXS spectra were collected in the low-Q region below and around the position of the first diffraction peak Q(m), i.e., in a range relatively unusual in this kind of investigation. The measured spectral moments clearly show a departure from their high-T classical expected values. We observe, moreover, that the amplitude of quantum deviations increases slightly with increasing density. This experimental method allows us to extract, even in a region where the dynamics still maintains a collective character, such typical single particle properties as the mean atomic kinetic energy.

SELECTION OF CITATIONS
SEARCH DETAIL
...