Front Physiol ; 14: 1168314, 2023.
Article in English | MEDLINE | ID: mdl-37304823

ABSTRACT

There is emerging evidence that mechanical properties of in vivo muscle tissues are associated with postural sway during quiet standing. However, it is unknown if the observed relationship between mechanical properties with static balance parameters generalise to dynamic balance. Thus, we determined the relationship between static and dynamic balance parameters with muscle mechanical properties of the ankle plantar flexors [lateral gastrocnemius (GL)] and knee extensors [vastus lateralis (VL)] in vivo. Twenty-six participants (men = 16, women = 10; age = 23.3 ± 4.4 years) were assessed for static balance [centre of pressure (COP) movements during quiet standing], dynamic balance (reach distances for the Y-balance test) and mechanical properties (stiffness and tone) of the GL and VL measured in the standing and lying position. Significant (p < .05) small to moderate inverse correlations were observed between the mean COP velocity during quiet standing with stiffness (r = -.40 to -.58, p = .002 to .042) and tone (r = -0.42 to -0.56, p = 0.003 to 0.036) of the GL and VL (lying and standing). Tone and stiffness explained 16%-33% of the variance in the mean COP velocity. Stiffness and tone of the VL measured in the lying (supine) condition were also inversely significantly correlated with Y balance test performance (r = -0.39 to -0.46, p = 0.018 to 0.049). These findings highlight that individuals with low muscle stiffness and tone exhibit faster COP movements during quiet standing, indicative of reduced postural control but also reveal that low VL stiffness and tone are associated with greater reach distances in a lower extremity reaching task, indicative of greater neuromuscular performance.

2.
J Sports Med Phys Fitness ; 63(1): 16-22, 2023 Jan.
Article in English | MEDLINE | ID: mdl-35230068

ABSTRACT

BACKGROUND: The aim of the study is to examine the relationship between measures of muscle and tendon mechanical properties and strength on countermovement jump (CMJ) performance. METHODS: Twenty-six physically active participants (males; N.=16: females; N.=10) were tested. Testing comprised of measuring the mechanical properties of lower limb muscles and tendons using myotonometry, isometric and isokinetic knee extensor strength through dynamometry, and CMJ's with a force platform. RESULTS: Large positive correlations were observed between CMJ jump height and Achilles tendon stiffness (N/m) (r=0.56) and Achilles tendon tone (Hz) (r=0.553). Large negative correlations were found between CMJ height and Achilles tendon elasticity (r=-0.658), and Achilles tendon relaxation (r=-0.572), and Achilles tendon creep (r=-0.589). Large correlations (r=0.592 to 0.659) were observed between CMJ height and all measures of isometric and isokinetic dynamometry measures. Achilles tendon stiffness, elasticity level and relaxation, and isokinetic peak concentric torque (N.m) explained 63% of this variance. CONCLUSIONS: Greater stiffness of the Achilles tendon may improve CMJ performance due to the improved transfer of concentric and eccentric force of the knee extensor muscles. Practitioners need to implement specific interventions to target increasing Achilles tendon stiffness to improve countermovement jump performance.


Subject(s)
Achilles Tendon , Muscle, Skeletal , Male , Female , Humans , Torque , Muscle, Skeletal/physiology , Lower Extremity , Achilles Tendon/physiology , Knee , Muscle Strength/physiology
3.
Skin Res Technol ; 28(2): 236-245, 2022 Mar.
Article in English | MEDLINE | ID: mdl-34751466

ABSTRACT

BACKGROUND: There is still a lack of clinically practical device, which allows to perform rapid and accurate examination of the skin condition. For this reason, suitability of the MyotonPRO for the assessment of skin biomechanical and viscoelastic parameters was evaluated in this study. The aim of the study was to establish the reference values of five parameters measured by MyotonPRO various locations of human skin. MATERIALS AND METHODS: Oscillation frequency, dynamic stiffness, logarithmic decrement, mechanical stress relaxation and creep were measured at three different skin locations (clavicula, volar forearm and shin), using L-shape short and medium arm probes in 32 young female volunteers. Mean values of obtained parameters recorded by both probes were compared among three skin locations while reliabilities of measurements were assessed. Additionally, relationships between all recorded parameters were examined RESULTS: There were no statistically significant differences between the mean values of five measured parameters obtained with both probes in all investigated areas. However, statistically significant differences of mean values of almost all parameters measured among three places examined were found. Despite considerable differences in mean values of obtained parameters, there were visible strong correlations between some studied parameters in all three investigated areas of skin. CONCLUSION: It was demonstrated in all locations studied that the higher value of oscillation frequency corresponds to the higher value of dynamic stiffness, moreover such tissue recovers faster to its initial shape, and it was characterized by lower creep values. Such results indicate the existence of identical relationships between the same studied parameters in different areas of skin.


Subject(s)
Human Body , Skin , Biomechanical Phenomena , Elasticity , Female , Forearm , Humans , Leg , Stress, Mechanical
4.
Skin Res Technol ; 27(3): 332-339, 2021 May.
Article in English | MEDLINE | ID: mdl-33078499

ABSTRACT

BACKGROUND: Stiffness of skin is widely used parameter in many research areas, for example cosmetic industry, dermatology or rheumatology for assessing of skin condition as well as changes occurring in skin. In this pioneering study, we conducted measurements of skin stiffness using MyotonPRO -novel tool, which was mainly used to evaluate biomechanical properties of muscles, ligaments and tendons. We expected that MyotonPRO , which shows great reproducibility in previous studies, will also be able to measure skin stiffness. MATERIALS AND METHODS: Four replaceable probes designed by MyotonPRO (L-shape short and medium arm, standard cylindrical flat-end probe and the same standard probe with disc attachment ) were tested for measurement of skin stiffness in young women (30 healthy females) at three different locations (clavicula, volar forearm and shin). RESULTS: There was no significant difference between stiffness values obtained with L-shape short and L-shape medium arm probes in all investigated areas. Stiffness values recorded by regular probe and regular probe with disc attachment differ significantly from those collected with L-shape probes. There was also significant difference between values of stiffness obtained by standard with disc attachment and standard probes. CONCLUSION: Both L-shape probes show a great reliability for skin stiffness assessment. Therefore, MyotonPRO can be considered a reliable device for assessing skin stiffness.


Subject(s)
Arm , Leg , Female , Forearm , Humans , Muscles , Reproducibility of Results