Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Main subject
Language
Publication year range
1.
J Contam Hydrol ; 237: 103758, 2021 Feb.
Article in English | MEDLINE | ID: mdl-33476871

ABSTRACT

Artificial basins are used to recharge groundwater by many municipalities to improve the sustainability of storm water management. Despite its increasing operational implementation, artificial recharge still raises numerous questions related to its impact on groundwater quality. In this paper, a 3D numerical model of MAR basin/aquifer system was implemented in order to simulate the fate of water and pollutants. It was used to illustrate the complex distribution in time and space of a tracer contaminant injected in the basin. The model was based on a well instrumented storm water infiltration basin located in Chassieu (Lyon area, France). The well-known Richards model was used to simulate the water flow in the saturated and unsaturated zone of the study site. The transfer of solutes in the basin/aquifer system was modelled by the advection-dispersion-equation (ADE). The model was calibrated during a rain event using hydraulic head and electric conductivity data from a set of piezometers located around the basin. The flow model was validated on a one month period of basin operation presenting several rain events. The model was then used to simulate the fate of a solute pollutant considered as a tracer during a high intensity rain event. This simplified test case illustrated the mechanism of capillary trapping in the vadose zone and the effect of sampling point location on concentration measurements. Three main results were obtained: (1) capillary trapping promoted a retention of up to 20% of the injected tracer in the vadose zone, (2) 0 to 24% of the injected solute concentration could be recovered depending on the piezometer location, (3) the averaged concentration decreased by 50% if the measuring device is lowered by 5 m under the water table. These results were strongly site and event dependant but observed trends should be considered while discussing punctual water quality measurements used to monitor MAR systems. It also allowed to suggest some guidelines for sampling point positioning.


Subject(s)
Groundwater , Cities , France , Rain , Water Movements
2.
Sci Total Environ ; 572: 986-994, 2016 Dec 01.
Article in English | MEDLINE | ID: mdl-27531465

ABSTRACT

Underground structures have a major influence on groundwater temperature and have a major contribution on the anthropogenic heat fluxes into urban aquifers. Groundwater temperature is crucial for resource management as it can provide operational sustainability indicators for groundwater quality and geothermal energy. Here, a three dimensional heat transport modeling approach was conducted to quantify the thermally affected zone (TAZ, i.e. increase in temperature of more than +0.5°C) caused by two common underground structures: (1) an impervious structure and (2) a draining structure. These design techniques consist in (1) ballasting the underground structure in order to resist hydrostatic pressure, or (2) draining the groundwater under the structure in order to remove the hydrostatic pressure. The volume of the TAZ caused by these underground structures was shown to range from 14 to 20 times the volume of the underground structure. Additionally, the cumulative impact of underground structures was assessed under average thermal conditions at the scale of the greater Lyon area (France). The heat island effect caused by underground structures was highlighted in the business center of the city. Increase in temperature of more than +4.5°C were locally put in evidence. The annual heat flow from underground structures to the urban aquifer was computed deterministically and represents 4.5GW·h. Considering these impacts, the TAZ of deep underground structures should be taken into account in the geothermal potential mapping. Finally, the amount of heat energy provided should be used as an indicator of heating potential in these areas.

SELECTION OF CITATIONS
SEARCH DETAIL
...