Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Diagnostics (Basel) ; 14(4)2024 Feb 17.
Article in English | MEDLINE | ID: mdl-38396480

ABSTRACT

BACKGROUND: This study is a systematic review with meta-analysis comparing radioactive seed localization (RSL) versus radio-guided occult lesion localization (ROLL) and wire-guided localization (WGL) for patients with impalpable breast cancer undergoing breast-conserving surgery and evaluating efficacy, safety, and logistical outcomes. The protocol is registered in PROSPERO with the number CRD42022299726. METHODS: A search was conducted in the Embase, Lilacs, Pubmed, Scielo, Web of Science, and clinicaltrials.gov databases, in addition to a manual search in the reference list of relevant articles, for randomized clinical trials and cohort studies. Studies selected were submitted to their own data extraction forms and risk of bias analysis according to the ROB 2 and ROBINS 1 tools. A meta-analysis was performed, considering the random effect model, calculating the relative risk or the mean difference for dichotomous or continuous data, respectively. The quality of the evidence generated was analyzed by outcome according to the GRADE tool. Overall, 46 articles met the inclusion criteria and were included in this systematic review; of these, 4 studies compared RSL and ROLL with a population of 1550 women, and 43 compared RSL and WGL with a population of 19,820 women. RESULTS: The results showed that RSL is a superior method to WGL in terms of surgical efficiency in the impalpable breast lesions' intraoperative localization, and it is at least equivalent to ROLL. Regarding security, RSL obtained results equivalent to the already established technique, the WGL. In addition to presenting promising results, RSL has been proven to be superior to WGL and ROLL technologies.

2.
Nanotheranostics ; 8(1): 112-126, 2024.
Article in English | MEDLINE | ID: mdl-38164500

ABSTRACT

Background: Nanotechnology has revolutionized medicine, especially in oncological treatments. Gold nanoparticles (AuNPs) stand out as an innovative alternative due to their biocompatibility, potential for surface modification, and effectiveness in radiotherapeutic techniques. Given that prostate cancer ranks as one of the leading malignancies among men, there's a pressing need to investigate new therapeutic approaches. Methods: AuNPs coated with bovine serum albumin (BSA) were synthesized and their cytotoxicity was assessed against prostate tumor cell lines (LNCaP and PC-3), healthy prostate cells (RWPE-1), and endothelial control cells (HUVEC) using the MTS/PMS assay. For in vivo studies, BALB/C Nude mice were employed to gauge the therapeutic efficacy, biodistribution, and hematological implications post-treatment with BSA-coated AuNPs. Results: The BSA-coated AuNPs exhibited cytotoxic potential against PC-3 and LNCaP lines, while interactions with RWPE-1 and HUVEC remain subjects for further scrutiny. Within animal models, a diverse therapeutic response was observed, with certain instances indicating complete tumor regression. Biodistribution data emphasized the nanoparticles' affinity towards particular organs, and the majority of hematological indicators aligned with normative standards. Conclusions: BSA-coated AuNPs manifest substantial promise as therapeutic tools in treating prostate cancer. The present research not only accentuates the nanoparticles' efficacy but also stresses the imperative of optimization to ascertain both selectivity and safety. Such findings illuminate a promising trajectory for avant-garde therapeutic modalities, holding substantial implications for public health advancements.


Subject(s)
Metal Nanoparticles , Prostatic Neoplasms , Male , Animals , Mice , Humans , Gold/pharmacology , Prostate/metabolism , Serum Albumin, Bovine/metabolism , Tissue Distribution , Mice, Nude , Metal Nanoparticles/therapeutic use , Mice, Inbred BALB C , Prostatic Neoplasms/radiotherapy , Prostatic Neoplasms/metabolism , Radioisotopes
3.
Int J Surg Protoc ; 26(1): 94-106, 2022.
Article in English | MEDLINE | ID: mdl-36447622

ABSTRACT

Background: The radioactive seed localization (RSL) is used in impalpable breast cancer conservative surgery to assist the surgeon in accurately locating and excising the lesion site. This study aims to present recommendations about the RSL program implementation in health institutions that perform breast cancer conservative surgery with intraoperative localization. Methods: An extensive literature review was performed. It comprehends: the committee responsible for implementation of the program actions; description of the necessary multidisciplinary team; the radiological safety committee role; the facility licensing; professionals training; material and instrumentation associated with the technique; and seed tracking system. Results: 13 topics are presented. The Program Implementation Committee must be formed by leaders from each department. The committee assumes responsibility for evaluating the necessary processes and presenting the schedule for program implementation. Since the procedure is classified as a nuclear medicine procedure it requires licensing. The Professional Team Formation, Education, and Training is a priority and simulation exercises are necessary. The Materials and Instrumentation Associated with the Technique must be well-know by the team and they should practice using radiation detectors. The seed must be always tracked, from moment they are received to discard. An Inventory for Tracking Seeds is provided. The Radiological Safety Aspects such as the ALARA principle are presented. A full description for the Radiological Procedure for Placing the seeds, the surgical removal and the Specimen Handling in Pathology focusing on how to locate the seed and retrieve them. After removed, the seeds can be placed in storage to wait for full radioactive decay or be returned to the manufacturer. Conclusions: The procedure has the advantage to increase to 2 months the time between insertion of the seed and the surgical removal. Regular multidisciplinary team meetings during program development are important to create a realistic timeline, having briefing meetings after the first 1-5 RSL cases and having annual or biannual follow-up meetings to discuss any issues or incidents. Abstract Graphic ImageCreated by Macrovector, obtained in Freepik at https://br.freepik.com/fotos-vetores-gratis/oncologia.This graphical abstract shows everything that is necessary to implement the RSL technique and are discussed in this paper. Highlights: This study present recommendations for RSL program implementation in hospitalsWas performed by an extensive descriptive and qualitative literature reviewTopics 1: Implementation Committee, Professional Team Training, InstrumentationTopics 2: Radiological Safety, Patient Consent, Radiological ProcessTopics 3: Surgical Procedure, Pathology, Seeds Disposal Completion.

4.
Appl Radiat Isot ; 169: 109568, 2021 Mar.
Article in English | MEDLINE | ID: mdl-33385758

ABSTRACT

Few places in the world produce iodine-125. In Brazil, the first production was achieved by using the IEA-R1 nuclear reactor located at Nuclear and Energy Research Institute - IPEN. To verify the quality of iodine-125 produced, and the amount of contaminants such as iodine-126, cesium-134 and caesium-137 among others, iodine-125 samples were immobilized into epoxy matrix disc, with the same geometry of a barium-133 reference radioactive source, used to calibrate an HPGe detector. The HPGe detector has a thin carbon composite window, which allows measure the iodine-125 photopeaks, between 27.1 and 35.4 keV. The method employed here was successful in producing and measurement of iodine-125.

5.
Appl Radiat Isot ; 165: 109307, 2020 Nov.
Article in English | MEDLINE | ID: mdl-32738753

ABSTRACT

In order to provide prostate brachytherapy treatment for more Brazilian men, IPEN is building a laboratory for the manufacture of radioactive sources. The new methodology for the production of iodine-125 seeds with yield 71.7% ± 5.3%. Points of importance were evaluated/discussed: photo-sensibility, reaction vial type, the substitution for iodine-131, pH, and solution volume. The surface was analyzed by FTIR and EDS. At the end, a Monte Carlo-MCNP6 simulation was performed to evaluate the TG-43 parameters.


Subject(s)
Iodine Radioisotopes/therapeutic use , Neoplasms/radiotherapy , Prostatic Neoplasms/radiotherapy , Brachytherapy/methods , Humans , Iodine Radioisotopes/administration & dosage , Male , Monte Carlo Method , Spectrometry, X-Ray Emission , Spectroscopy, Fourier Transform Infrared
6.
Med Phys ; 42(4): 1566-74, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25832047

ABSTRACT

PURPOSE: This work presents the development of a phantom to verify the treatment planning system (TPS) algorithms used for high-dose-rate (HDR) brachytherapy. It is designed to measure the relative dose in a heterogeneous media. The experimental details used, simulation methods, and comparisons with a commercial TPS are also provided. METHODS: To simulate heterogeneous conditions, four materials were used: Virtual Water™ (VM), BR50/50™, cork, and aluminum. The materials were arranged in 11 heterogeneity configurations. Three dosimeters were used to measure the relative response from a HDR (192)Ir source: TLD-100™, Gafchromic(®) EBT3 film, and an Exradin™ A1SL ionization chamber. To compare the results from the experimental measurements, the various configurations were modeled in the penelope/penEasy Monte Carlo code. Images of each setup geometry were acquired from a CT scanner and imported into BrachyVision™ TPS software, which includes a grid-based Boltzmann solver Acuros™. The results of the measurements performed in the heterogeneous setups were normalized to the dose values measured in the homogeneous Virtual Water™ setup and the respective differences due to the heterogeneities were considered. Additionally, dose values calculated based on the American Association of Physicists in Medicine-Task Group 43 formalism were compared to dose values calculated with the Acuros™ algorithm in the phantom. Calculated doses were compared at the same points, where measurements have been performed. RESULTS: Differences in the relative response as high as 11.5% were found from the homogeneous setup when the heterogeneous materials were inserted into the experimental phantom. The aluminum and cork materials produced larger differences than the plastic materials, with the BR50/50™ material producing results similar to the Virtual Water™ results. Our experimental methods agree with the penelope/penEasy simulations for most setups and dosimeters. The TPS relative differences with the Acuros™ algorithm were similar in both experimental and simulated setups. The discrepancy between the BrachyVision™, Acuros™, and TG-43 dose responses in the phantom described by this work exceeded 12% for certain setups. CONCLUSIONS: The results derived from the phantom measurements show good agreement with the simulations and TPS calculations, using Acuros™ algorithm. Differences in the dose responses were evident in the experimental results when heterogeneous materials were introduced. These measurements prove the usefulness of the heterogeneous phantom for verification of HDR treatment planning systems based on model-based dose calculation algorithms.


Subject(s)
Algorithms , Brachytherapy/instrumentation , Brachytherapy/methods , Phantoms, Imaging , Radiotherapy Planning, Computer-Assisted/instrumentation , Radiotherapy Planning, Computer-Assisted/methods , Computer Simulation , Equipment Design , Film Dosimetry , Humans , Iridium Radioisotopes , Monte Carlo Method , Radiotherapy Dosage , Software , Thermoluminescent Dosimetry , Water
SELECTION OF CITATIONS
SEARCH DETAIL
...