Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Lab Autom ; 18(4): 306-27, 2013 Aug.
Article in English | MEDLINE | ID: mdl-23321915

ABSTRACT

Clinical laboratories need to test patient samples precisely, accurately, and efficiently. The latest member of the Roche cobas modular platform family, the cobas 8000 modular analyzer series allows compact and convenient consolidation of clinical chemistry and immunochemistry assays in high-workload laboratories with a throughput of 3 to 15 million tests annually. Here we present the results of studies designed to test the overall system performance under routine-like conditions that were conducted at 14 laboratories over 2 y. Experiments that test analytical performance of the new module were integrated with overall system functionality testing of all modules in different configurations. More than two million results were generated and evaluated for ~100 applications using serum/plasma, urine, or EDTA blood samples. During the workflow studies, eight configurations of the possible 38 combinations were used, covering all available analytical modules. The versatility of the module combinations makes the system customizable to fit the needs of diverse laboratories, allowing precise and accurate analysis of a broad spectrum of clinical chemistry and immunochemistry parameters with short turnaround times. This new system will contribute to the ability of clinical laboratories to offer better service to their customers and support vital clinical decision making.


Subject(s)
Chemistry Techniques, Analytical/instrumentation , Clinical Laboratory Techniques/instrumentation , Microfluidic Analytical Techniques , Australia , Automation, Laboratory , Chemistry Techniques, Analytical/standards , Diagnostic Tests, Routine , Europe , High-Throughput Screening Assays , Humans , Reproducibility of Results , United States
2.
Clin Chem Lab Med ; 41(1): 95-103, 2003 Jan.
Article in English | MEDLINE | ID: mdl-12636057

ABSTRACT

This international multicenter study was designed to evaluate the technical performance of the new double-monoclonal, single-step Elecsys neuron-specific enolase (NSE) enzyme immunoassay (EIA) and to assess its utility as a sensitive and specific test for the diagnosis of small-cell lung cancer (SCLC). Intra- and interassay coefficients of variation, determined in five control or serum specimens in six laboratories, ranged from 0.7 to 5.3 (inter-laboratory median: 1.3%) and from 1.3 to 8.5 (inter-laboratory median: 3.4%), respectively. Laboratory-to-laboratory comparability was excellent with respect to recovery and inter-assay coefficients of variation. The test was linear between 0.0 and 320 ng/ml (highest measured concentration). There was a significant correlation between NSE concentrations measured using the Elecsys NSE and the established Cobas Core NSE EIA II in all subjects (n = 723) and in patients with lung cancer (n = 333). However, NSE concentrations were systematically lower (approximately 9%) with the Elecsys NSE than with the comparison test. Based on a specificity of 95% in comparison with the group suffering from benign lung diseases (n = 183), the cut-off value for the discrimination between malignant and benign conditions was set at 21.6 ng/ml. NSE was raised in 73.4% of SCLC patients (n = 188) and was significantly higher (p < 0.01) in extensive (87.8%) as opposed to limited disease (56.7%). NSE was also elevated in 16.0% of the cases with non-small cell lung cancer (NSCLC, n = 374). It is concluded that the Elecsys NSE EIA is a reliable and accurate diagnostic procedure for the measurement of NSE in serum samples. The special merits of this new assay are the wide measuring range (according to manufacturer's declaration up to 370 ng/ml) and a short incubation time of 18 min.


Subject(s)
Biomarkers, Tumor/blood , Carcinoma, Non-Small-Cell Lung/enzymology , Carcinoma, Small Cell/diagnosis , Carcinoma, Small Cell/enzymology , Lung Neoplasms/diagnosis , Lung Neoplasms/enzymology , Phosphopyruvate Hydratase/analysis , Adenocarcinoma/blood , Adenocarcinoma/diagnosis , Adenocarcinoma/enzymology , Adult , Aged , Aged, 80 and over , Carcinoma, Large Cell/blood , Carcinoma, Large Cell/diagnosis , Carcinoma, Large Cell/enzymology , Carcinoma, Non-Small-Cell Lung/blood , Carcinoma, Non-Small-Cell Lung/diagnosis , Carcinoma, Small Cell/blood , Carcinoma, Squamous Cell/blood , Carcinoma, Squamous Cell/diagnosis , Carcinoma, Squamous Cell/enzymology , Case-Control Studies , Humans , Immunoassay/methods , Immunoenzyme Techniques , Lung/enzymology , Lung Neoplasms/blood , Middle Aged , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...