Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Orthopedics ; 44(5): 280-284, 2021.
Article in English | MEDLINE | ID: mdl-34590939

ABSTRACT

Although mechanical stress in total hip arthroplasty modular head-neck junctions is thought to contribute to the risk of trunnionosis and related metal ion disease in total hip arthroplasty, little is known about mechanical stress in the modular acetabular components. Recent retrieval analyses of dual-mobility constructs have demonstrated corrosion between liner and shell in some dual-mobility acetabular components. The objective of this study was to evaluate acetabular stress as a function of acetabular bone coverage, component modularity, and femoral head diameter. A parametric finite element model was created. The acetabulum was set at 40° of abduction and 15° of anteversion; superolateral bone loss up to 50° was modeled; and 28-mm, 32-mm, 36-mm, and 40-mm head sizes were simulated in stance phase of gait. Fixed polyethylene-bearing, monoblock and modular dual-mobility (MDM) acetabular components were evaluated. For traditional fixed-bearing components, the largest peak stress, 49.5 MPa, was observed with 50° of bone loss and a 28-mm head. The lowest peak stress, 6.3 MPa, occurred with complete bone coverage and a 36-mm head. Peak stress in the MDM construct, 25.1 MPa, concentrated in the chromium-cobalt portion of the construct. Larger head diameters are associated with decreased stress in the acetabular component when bone loss is present. An MDM construct with a stiff inner liner may decrease overall stress in the acetabular construct, but focally increased stress near the rim of uncovered acetabular components may increase the risk of metal-on-metal corrosion. [Orthopedics. 2021;44(5):280-284.].


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Acetabulum/surgery , Arthroplasty, Replacement, Hip/adverse effects , Finite Element Analysis , Hip Prosthesis/adverse effects , Humans , Polyethylene , Prosthesis Design
2.
J Arthroplasty ; 36(8): 2850-2857, 2021 08.
Article in English | MEDLINE | ID: mdl-33875289

ABSTRACT

BACKGROUND: Total hip arthroplasty (THA) patients expect pain relief and functional improvement, including return to physical activity. Our objective was to determine the impact of patients' physical activity level on preoperative expectations and postoperative satisfaction and clinical outcomes in patients undergoing THA. METHODS: Using an institutional registry of patients undergoing THA between 2007 and 2012, we retrospectively identified patients who underwent unilateral primary THA for osteoarthritis and completed a preoperative Lower Extremity Activity Scale, Hospital for Special Surgery Hip Replacement Expectations Survey, and Hip disability and Osteoarthritis Outcome Score in addition to two-year HOOS and satisfaction evaluations. Active patients (n = 1053) were matched to inactive patients (n = 1053) by age, sex, body mass index, and comorbidities. The cohorts were compared with regard to the association of expectations with Hip disability and Osteoarthritis Outcome Score and satisfaction, the change in Lower Extremity Activity Scale level from baseline to 2 years, complications, and revision surgical procedures. RESULTS: Significantly more active patients (74%) expected to be "back to normal" regarding ability to exercise and participate in sports compared with inactive patients (64%, P < .001). Overall satisfaction was similar. Higher expectations with regard to exercise and sports were associated with higher HOOS sports and recreation subdomain scores in active patients. The inactive patient group improved on baseline activity level at 2 years while the active group did not. CONCLUSION: At 2 years after THA, active and inactive patients were similarly satisfied and achieved comparable outcomes. Inactive patients showed a greater improvement in physical activity level from preoperative baseline than active patients. Complications and revision rates were similar. LEVEL OF EVIDENCE: III.


Subject(s)
Arthroplasty, Replacement, Hip , Exercise , Humans , Motivation , Patient Satisfaction , Personal Satisfaction , Retrospective Studies , Treatment Outcome
3.
Foot Ankle Spec ; 13(4): 281-285, 2020 Aug.
Article in English | MEDLINE | ID: mdl-31179731

ABSTRACT

Background. First metatarsophalangeal (MTP) arthrodesis is the "gold standard" treatment for hallux rigidus. Recently, there has been increased interest in new synthetic cartilage implants to preserve joint motion while eradicating pain. With current health care economics, the cost of a treatment is gaining particular importance. This study set out to perform a cost comparison between MTP arthrodesis and synthetic hydrogel implant to determine which treatment modality is more cost-effective based on direct aggregate costs. Study design. Economic and decision analysis. Methods. Studies in the available literature were analyzed to estimate hardware removal rates for MTP fusion and failure rates for a synthetic hydrogel implant and MTP fusion. Costs were determined by examining direct costs at a single institution for implants and data reported in the literature for operating room time. Sensitivity analysis and Monte Carlo simulation were performed to examine cost and measurement uncertainty. Results. Assuming a 4.76% MTP arthrodesis revision rate and 7.06% hardware removal rate, the total direct cost of MTP joint arthrodesis was $3632. Using a 9.2% failure rate with subsequent conversion to MTP arthrodesis, the total cost of synthetic hydrogel implant was $4565. Sensitivity analysis revealed that MTP fusion was more cost-effective even if the failure rate increased to 15% and synthetic hydrogel implant failure rate was 0%. The synthetic cartilage implant cost would have to be reduced 28% or approximately 200% the cost of MTP fusion implants to be comparable to MTP arthrodesis. Conclusion. Hallux rigidus treatment with a synthetic hydrogel implant resulted in a higher direct aggregate cost than MTP arthrodesis.Level of Evidence: Level II: Cost analysis.


Subject(s)
Arthrodesis/economics , Costs and Cost Analysis/economics , Hydrogels , Metatarsophalangeal Joint/surgery , Prosthesis Implantation/economics , Hallux Rigidus/surgery , Humans
4.
Foot Ankle Int ; 40(2): 231-236, 2019 Feb.
Article in English | MEDLINE | ID: mdl-30345830

ABSTRACT

BACKGROUND:: Lesser toe proximal interphalangeal (PIP) joint arthrodesis is one of the most common foot and ankle elective procedures often using K-wires for fixation. K-wire associated complications led to development of intramedullary fixation devices. We hypothesized that X Fuse (Stryker) and Smart Toe (Stryker) would provide stronger and stiffer fixation than K-wire fixation. METHODS:: 12 cadaveric second toe pairs were used. In one group, K-wires stabilized 6 PIP joints, and 6 contralateral PIP joints were fixed with X Fuse. A second group used K-wires to stabilize 6 PIP joints, and 6 contralateral PIP joints were fixed with Smart Toe. Specimens were loaded cyclically with extension bending using 2-N step increases (10 cycles per step). Load to failure and initial stiffness were assessed. Statistical analysis used paired t tests. RESULTS:: K-wire average failure force, 91.0 N (SD 28.3), was significantly greater than X Fuse, 63.3 N (SD 12.9) ( P < .01). K-wire average failure force, 102.3 N (SD 17.7), was also significantly greater than Smart Toe, 53.3 N (SD 18.7) ( P < .01). K-wire initial stiffness 21.3 N/mm (SD 5.7) was greater than Smart Toe 14.4 N/mm (SD 9.3) ( P = .02). K-wire failure resulted from bending of K-wire or breaching cortical bone. X Fuse typically failed by implant pullout. Smart Toe failure resulted from breaching cortical bone. CONCLUSION:: K-wires may provide stiffer and stronger constructs in extension bending than the X Fuse or Smart Toe system. This cadaver study assessed stability of the fusion site at time zero after surgery. CLINICAL RELEVANCE:: Our findings provide new data supporting biomechanical stability of K-wires for lesser toe PIP arthrodesis, at least in this clinically relevant mode of cyclic loading.


Subject(s)
Arthrodesis/instrumentation , Bone Wires , Hammer Toe Syndrome/surgery , Internal Fixators , Joint Instability/surgery , Toe Joint/surgery , Adult , Biomechanical Phenomena , Cadaver , Female , Hammer Toe Syndrome/physiopathology , Humans , Joint Instability/physiopathology , Male , Middle Aged , Toe Joint/physiopathology
5.
Arthroscopy ; 34(3): 979-987, 2018 03.
Article in English | MEDLINE | ID: mdl-29273257

ABSTRACT

PURPOSE: To determine if the failure rate and functional outcome after arthroscopic meniscus suture repair are age dependent. METHODS: A systematic review was conducted using a computerized search of the electronic databases MEDLINE and ScienceDirect in adherence with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Extracted data from each included study were recorded on a standardized form. Studies were included if they (1) were English-language studies in peer-reviewed journals, (2) used a distinct age cut-off to evaluate outcome of meniscal surgery for those above and below the specified cut-off, and (3) used meniscal repairs using suture based technique with inside-out, outside-in, or all-inside techniques. Review papers, case reports, technique papers, non-English language publications, abstracts, and data on meniscal repairs using meniscal screws, arrows, or darts were excluded. RESULTS: 15 of 305 identified articles met the inclusion/exclusion criteria. There were 1,141 menisci treated in 1,063 patients. Seven and 8 studies met the inclusion/exclusion criteria for analysis for the age thresholds of 25 years and 30 years, respectively, demonstrating no difference in failure rates relative to age threshold. Four of 6 studies that met analysis criteria found no difference in failure rates above or below an age threshold of 35 years. No significant difference in failure in patients younger than 40 than patients older than 40 was found for 4 of the 5 studies in that arm of the review. CONCLUSIONS: Analysis of the composite data in this systematic review reveals that no significant difference exists when evaluating meniscal repair failure rate as a function of age above or below the given age thresholds. LEVEL OF EVIDENCE: Level IV, systematic review of level III and IV studies.


Subject(s)
Arthroscopy/methods , Tibial Meniscus Injuries/surgery , Adult , Age Factors , Humans , Menisci, Tibial/surgery , Suture Techniques , Treatment Outcome
6.
J Orthop Trauma ; 29(10): e364-70, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26053467

ABSTRACT

OBJECTIVES: The biomechanical difficulty in fixation of a Vancouver B1 periprosthetic fracture is purchase of the proximal femoral segment in the presence of the hip stem. Several newer technologies provide the ability to place bicortical locking screws tangential to the hip stem with much longer lengths of screw purchase compared with unicortical screws. This biomechanical study compares the stability of 2 of these newer constructs to previous methods. METHODS: Thirty composite synthetic femurs were prepared with cemented hip stems. The distal femur segment was osteotomized, and plates were fixed proximally with either (1) cerclage cables, (2) locked unicortical screws, (3) a composite of locked screws and cables, or tangentially directed bicortical locking screws using either (4) a stainless steel locking compression plate system with a Locking Attachment Plate (Synthes) or (5) a titanium alloy Non-Contact Bridging system (Zimmer). Specimens were tested to failure in either axial or torsional quasistatic loading modes (n = 3) after 20 moderate load preconditioning cycles. Stiffness, maximum force, and failure mechanism were determined. RESULTS: Bicortical constructs resisted higher (by an average of at least 27%) maximum forces than the other 3 constructs in torsional loading (P < 0.05). Cables constructs exhibited lower maximum force than all other constructs, in both axial and torsional loading. The bicortical titanium construct was stiffer than the bicortical stainless steel construct in axial loading. CONCLUSIONS: Proximal fixation stability is likely improved with the use of bicortical locking screws as compared with traditional unicortical screws and cable techniques. In this study with a limited sample size, we found the addition of cerclage cables to unicortical screws may not offer much improvement in biomechanical stability of unstable B1 fractures.


Subject(s)
Bone Plates , Bone Screws , Femoral Fractures/physiopathology , Femoral Fractures/surgery , Fracture Fixation, Internal/instrumentation , Hip Prosthesis/adverse effects , Equipment Failure Analysis , Femoral Fractures/etiology , Humans , Prosthesis Design , Stress, Mechanical , Tensile Strength , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...