Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
J Med Eng Technol ; 43(1): 59-65, 2019 Jan.
Article in English | MEDLINE | ID: mdl-31074312

ABSTRACT

Gait analysis is a significant diagnostic procedure for the clinicians who manage musculoskeletal disorders. Surface electromyography (sEMG) combined with kinematic and kinetic data is a useful tool for decision making of the appropriate method needed to treat such patients. sEMG has been used for decades to evaluate neuromuscular responses during a range of activities and develop rehabilitation protocols. The sEMG methodology followed by researchers assessed the issues of noise control, wave frequency, cross talk, low signal reception, muscle co-contraction, electrode placement protocol and procedure as well as EMG signal timing, intensity and normalisation so as to collect accurate, adequate and meaningful data. Further research should be done to provide more information related to the muscle activity recorded by sEMG and the force produced by the corresponding muscle during gait analysis.


Subject(s)
Electromyography/methods , Gait Analysis/methods , Electrodes , Humans , Muscle, Skeletal/physiology , Signal Processing, Computer-Assisted
2.
J Orthop ; 15(1): 181-185, 2018 Mar.
Article in English | MEDLINE | ID: mdl-29657464

ABSTRACT

Gait analysis using external skin markers provides scope for the study of kinematic and kinetic parameters shown on different total knee arthroplasties (TKA). Thus an appropriate methodology is of great importance for the collection and correlation of valid data. Calibration of equipment is of great importance before measurements, to assure accuracy. Force plates should be calibrated to 1080 Hz and optoelectronic cameras should use 120 Hz frequency, because of the nature of gait activity. Davis model which accurately defines the position of the markers is widely accepted and cited, for the gait analysis of TKA's. To ensure the reproducibility of the measurement, a static trial at the anatomical position must be captured. Following, all acquisitions of dynamic data must be checked for consistency in walking speed, and abnormal gait style because of fatigue or distraction. To establish the repeatability of the measurement, this procedure must be repeated at a pre-defined number of 3-5 gait cycles. Anthropometric measurements should be combined with three-dimensional marker data from the static trial to provide positions of the joint's center and define anatomical axes of total knee arthroplasty. Kinetic data should be normalized to bodyweight (BW) and percentage of BW and height depending on the study. External moments should also be calculated by using inverse dynamics and amplitude-normalized to body mass (Nm/kg). Gait analysis using external skin markers provides scope for the study of biomechanical parameters shown on different TKAs. Thus a standard gait analysis methodology when measuring TKA biomechanical parameters is necessary for the collection and correlation of accurate, adequate, valid and reproducible data. Further research should be done to clarify if the development of a specific kinematic model is appropriate for a more accurate definition of total knee implant joint center in measurements concerning 3D gait analysis.

4.
J Arthroplasty ; 31(8): 1814-20, 2016 08.
Article in English | MEDLINE | ID: mdl-26923498

ABSTRACT

BACKGROUND: Total knee arthroplasties (TKAs) using well-designed, fixed bearing prostheses, such as medial pivot (MP), have produced good long-term results. Rotating-platform, posterior-stabilized (RP-PS) mobile bearing implants were designed to decrease polyethylene wear. Sagittal and coronal plane TKA biomechanics are well examined and correlated to polyethylene wear. However, limited research findings describe this relationship in transverse plane. We assumed that although axial plane biomechanics might not be the most destructive parameters on polyethylene wear, it is important to clarify their role because both joint kinematics and kinetics in all 3 planes are important input parameters for TKA wear testing (International Organization for Standardization 14243-1 and 14343-3). Our hypothesis was that transverse plane overall range of motion (ROM) and/or peak moment show differences that reflect on wear advantages when compared RP-PS implants to MP designs. METHODS: Two groups (MPs = 24 and RP-PSs = 22 subjects) were examined by using 3D gait analysis. The variables were total internal-external rotation (IER) ROM and peak IER moments. RESULTS: No statistically significant difference was demonstrated between the 2 groups in kinetics (P = .389) or kinematics (P = .275). CONCLUSION: In the present study, no wear advantages were found between 2 TKAs. Both designs showed identical kinetics at the transverse plane in level-ground walking. Kinematic analysis could not illustrate any statistically significant difference in terms of overall IER ROM. Nevertheless, kinematic gait pattern differences observed possibly reflect different patterns of joint surface motion or abnormal gait patterns. Thus, wear testing with various input waveforms combined with functional data analysis will be necessary to identify the actual effects of gait variability on polyethylene wear.


Subject(s)
Arthroplasty, Replacement, Knee/methods , Knee Joint/surgery , Knee Prosthesis , Prosthesis Design , Aged , Biomechanical Phenomena , Female , Gait , Humans , Male , Middle Aged , Polyethylene , Prosthesis Failure , Range of Motion, Articular , Walking
SELECTION OF CITATIONS
SEARCH DETAIL
...