Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 42
Filter
1.
J Med Econ ; 27(1): 758-765, 2024.
Article in English | MEDLINE | ID: mdl-38708771

ABSTRACT

INTRODUCTION: Etranacogene dezaparvovec (EDZ), Hemgenix, is a gene therapy recently approved for people with hemophilia B (PwHB). OBJECTIVE: To estimate long-term clinical impact and cost of EDZ in the United States (US). METHODS: A decision-analytic model was developed to evaluate the long-term impact of introducing EDZ for PwHB over a 20-year time horizon. Factor IX (FIX) prophylaxis comparator was a weighted average of different FIX prophylaxis regimens based on US market share data. We compared a scenario in which EDZ is introduced in the US versus a scenario without EDZ. Clinical inputs (annualized FIX-treated bleed rate; adverse event rates) were obtained from HOPE-B phase 3 trial. EDZ durability input was sourced from an analysis predicting long-term FIX activity with EDZ. EDZ one-time price was assumed at $3.5 million. Other medical costs, including FIX prophylaxis, disease monitoring, bleed management, and adverse events were from literature. The model estimated annual and cumulative costs, treated bleeds, and joint procedures over 20 years from EDZ introduction. RESULTS: Approximately 596 PwHB were eligible for EDZ. EDZ uptake was estimated to avert 11,282 bleeds and 64 joint procedures over 20 years. Although adopting EDZ resulted in an annual excess cost over years 1-5 (mean: $53 million annually, total $265 million), annual cost savings were achieved beginning in year 6 (mean: $172 million annually; total $2.58 billion in years 6-20). The total cumulative 20-year cost savings was $2.32 billion, with cumulative cost savings beginning in year 8. CONCLUSION: Introducing EDZ to treat PwHB is expected to result in cost savings and patient benefit over 20 years. Initiating PwHB on EDZ sooner can produce greater and earlier savings and additional bleeds avoided. These results may be a conservative estimate of the full value of EDZ, as PwHB would continue to accrue savings beyond 20 years.


This analysis assessed the long-term clinical and financial impact of introducing EDZ in the United States of America for people with severe or moderately severe hemophilia B. A decision-analytic model was developed comparing a scenario with EDZ and one without EDZ over 20 years. Introducing EDZ would avert 11,292 bleeds and 64 joint procedures over 20 years and would achieve cumulative cost savings in year 8, with a total cumulative 20-year cost saving of $2.32 billion.


Subject(s)
Factor IX , Hemophilia B , Humans , Hemophilia B/drug therapy , Hemophilia B/economics , United States , Factor IX/economics , Factor IX/therapeutic use , Hemorrhage/economics , Genetic Therapy/economics , Cost-Benefit Analysis , Decision Support Techniques , Adult , Male , Child , Young Adult , Adolescent
2.
J Manag Care Spec Pharm ; : 1-12, 2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38625717

ABSTRACT

BACKGROUND: Etranacogene dezaparvovec is a recently approved gene therapy for people with hemophilia B (PwHB). Current standard of care is prophylaxis with factor IX (FIX) to prevent bleeding. Etranacogene dezaparvovec increases blood FIX levels such that FIX prophylaxis could be eliminated. OBJECTIVE: To estimate the budgetary impact of etranacogene dezaparvovec adoption and utilization in a commercial health plan of the United States. METHODS: A budget impact model was developed to evaluate the introduction of etranacogene dezaparvovec to treat severe or moderately severe hemophilia B. The model considered a hypothetical 1-million-member plan over a 5-year horizon. FIX therapy prophylaxis use was estimated based on a weighted average of relevant brands using US market share data. A scenario of etranacogene dezaparvovec adoption/utilization was compared with one without etranacogene dezaparvovec utilization. Two etranacogene dezaparvovec uptake (market share growth) analyses were performed: one with gradual uptake and alternatively assuming all eligible PwHB received etranacogene dezaparvovec in year 1. The one-time cost of etranacogene dezaparvovec was assumed to be $3.5 million. Other costs (FIX prophylaxis, disease monitoring, bleed management, and adverse events) were estimated from published literature. All costs were in 2022 US dollars. Bleed and adverse event rates were sourced from the HOPE-B trial comparing etranacogene dezaparvovec to previous FIX therapy prophylaxis. The model estimated annual and per-member per-month costs over 5 years. Secondary analyses were performed considering a 10-year horizon. RESULTS: In the 1-million-member health plan, an estimated 1.8 PwHB were eligible for treatment with etranacogene dezaparvovec. Gradual uptake of etranacogene dezaparvovec resulted in cumulative 5-year budget impact of $848,509 compared with a scenario without etranacogene dezaparvovec. In years 1-5, the incremental annual and per-member per-month costs ranged from $79,824 to $271,435 and from $0.007 to $0.023, respectively. In the alternative uptake analysis, etranacogene dezaparvovec became cost saving annually beginning in year 2 and cumulatively beginning in year 5, for a 5-year savings of $754,844. Secondary analyses over 10 years found both uptake analyses cost saving. Other scenarios considered did not affect results substantially. CONCLUSIONS: Introducing etranacogene dezaparvovec as treatment for PwHB would have a modest budget increase within 5 years after treatment but may become cost saving if all eligible PwHB were treated in year 1. Initiating PwHB on etranacogene dezaparvovec sooner may produce greater overall savings and earlier annual savings. Etranacogene dezaparvovec is a treatment option that may provide overall cost savings for US commercial health plans, which would increase as the plan size increases.

3.
Gastrointest Endosc ; 87(4): 1106-1113, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29208464

ABSTRACT

BACKGROUND AND AIMS: Balancing the risks for thromboembolism and postpolypectomy bleeding in patients requiring anticoagulation and antiplatelet agents is challenging. We investigated the incidence and risk factors for postpolypectomy bleeding on anticoagulation, including heparin bridge and other antithrombotic therapy. METHODS: We performed a retrospective cohort and case control study at 2 tertiary-care medical centers from 2004 to 2012. Cases included male patients on antithrombotics with hematochezia after polypectomy. Nonbleeding controls were matched to cases 3 to 1 by antithrombotic type, study site, polypectomy technique, and year of procedure. Our outcomes were the incidence and risk factors for postpolypectomy bleeding. RESULTS: There were 59 cases and 174 matched controls. Postpolypectomy bleeding occurred in 14.9% on bridge anticoagulation. This was significantly higher than the overall incidence of bleeding on antithrombotics at 1.19% (95% confidence interval, 0.91%-1.54%) (59/4923). We identified similarly low rates of bleeding in patients taking warfarin (0.66%), clopidogrel (0.84%), and aspirin (0.92%). Patients who bled tended to have larger polyps (13.9 vs 7.3 mm; P < .001) and more polyps ≥2 cm (41% vs 10%; P < .001). Bleeding risk was increased with restarting antithrombotics within 1 week postpolypectomy (odds ratio [OR] 4.50; P < .001), having polyps ≥2 cm (OR 5.94; P < .001), performing right-sided cautery (OR 2.61; P = .004), and having multiple large polyps (OR 2.92; P = .001). Among patients on warfarin, the presence of bridge anticoagulation was an independent risk factor for postpolypectomy bleeding (OR 12.27; P = .0001). CONCLUSION: We conclude that bridge anticoagulation is associated with a high incidence of postpolypectomy bleeding and is an independent risk factor for hemorrhage compared with patients taking warfarin alone. A higher threshold to use bridge anticoagulation should be considered in patients with an elevated bleeding risk.


Subject(s)
Colonic Polyps/surgery , Colorectal Neoplasms/surgery , Gastrointestinal Hemorrhage/epidemiology , Platelet Aggregation Inhibitors/therapeutic use , Postoperative Hemorrhage/epidemiology , Aged , Anticoagulants/therapeutic use , Aspirin/therapeutic use , Case-Control Studies , Clopidogrel , Colonic Polyps/pathology , Colonoscopy , Colorectal Neoplasms/pathology , Female , Gastrointestinal Hemorrhage/etiology , Heparin, Low-Molecular-Weight/therapeutic use , Humans , Incidence , Male , Middle Aged , Postoperative Hemorrhage/etiology , Retrospective Studies , Risk Factors , Thromboembolism/prevention & control , Ticlopidine/analogs & derivatives , Ticlopidine/therapeutic use , Time Factors , Warfarin/therapeutic use
4.
Sci Rep ; 7(1): 9309, 2017 08 24.
Article in English | MEDLINE | ID: mdl-28839158

ABSTRACT

Optical molecular imaging holds the potential to improve cancer diagnosis. Fluorescent nanoparticles such as quantum dots (QD) offer superior optical characteristics compared to organic dyes, but their in vivo application is limited by potential toxicity from systemic administration. Topical administration provides an attractive route for targeted nanoparticles with the possibility of minimizing exposure and reduced dose. Previously, we demonstrated successful ex vivo endoscopic imaging of human bladder cancer by topical (i.e. intravesical) administration of QD-conjugated anti-CD47. Herein we investigate in vivo biodistribution and toxicity of intravesically instilled free QD and anti-CD47-QD in mice. In vivo biodistribution of anti-CD47-QD was assessed with inductively coupled plasma mass spectrometry. Local and systemic toxicity was assessed using blood tests, organ weights, and histology. On average, there was no significant accumulation of QD outside of the bladder, although in some mice we detected extravesical biodistribution of QD suggesting a route for systemic exposure under some conditions. There were no indications of acute toxicity up to 7 days after instillation. Intravesical administration of targeted nanoparticles can reduce systemic exposure, but for clinical use, nanoparticles with established biosafety profiles should be used to decrease long-term toxicity in cases where systemic exposure occurs.


Subject(s)
Molecular Imaging/methods , Optical Imaging/methods , Quantum Dots/administration & dosage , Quantum Dots/adverse effects , Tissue Distribution , Urinary Bladder Neoplasms/diagnostic imaging , Administration, Intravesical , Animal Structures/drug effects , Animal Structures/pathology , Animals , Drug-Related Side Effects and Adverse Reactions/pathology , Histocytochemistry , Mass Spectrometry , Mice , Molecular Imaging/adverse effects , Optical Imaging/adverse effects , Plasma/chemistry
6.
Clin Gastroenterol Hepatol ; 15(2): 249-256.e1, 2017 02.
Article in English | MEDLINE | ID: mdl-27639328

ABSTRACT

BACKGROUND & AIMS: Nonpolypoid colorectal neoplasms (NP-CRNs) are more likely to contain high-grade dysplasia or early-stage cancer than polypoid neoplasms. We aimed to determine the long-term outcomes of patients with at least 1 NP-CRN. METHODS: We performed a longitudinal cohort study of 4454 patients at a Veterans' Affairs hospital who underwent colonoscopy from 2000 through 2005; 341 were found to have 1 or more NP-CRNs and were matched (3:1) with patients found to have 1 or more polypoid neoplasms (controls, n = 1025). We collected and analyzed data on baseline colonoscopy findings and first follow-up colonoscopy results through August 2014. We calculated the incidence of advanced neoplasia at first follow-up colonoscopy, as defined by the presence of ≥1 tubular or sessile serrated adenomas ≥10 mm in diameter, tubulovillous adenoma, high-grade dysplasia, or invasive cancer. RESULTS: A significantly higher proportion of patients with 1 or more NP-CRNs (16.0%) were found to have advanced neoplasia at their first follow-up colonoscopy than controls (8.6%); the adjusted risk ratio was 1.6 (95% confidence interval, 1.05-2.6; P = .03). A significantly higher proportion of patients with 1 or more NP-CRNs were found to have additional NP-CRNs at the follow-up colonoscopy (17%) than controls (7%; relative risk, 2.3; 95% confidence interval, 1.5-3.5; P < .001). Similar proportions of patients in each group developed cancers after colonoscopy. CONCLUSIONS: In a longitudinal cohort study, we found that patients with NP-CRN were more likely to develop additional NP-CRNs and to have advanced neoplasms at their first follow-up colonoscopy than patients with only polypoid neoplasms. However, patients with NP-CRN were not more likely to develop cancers after colonoscopy when surveillance guidelines were followed. Larger studies are needed to determine risk of colorectal cancer in patients with NP-CRN.


Subject(s)
Colorectal Neoplasms/pathology , Polyps/pathology , Aged , Colonoscopy , Female , Humans , Longitudinal Studies , Male , Middle Aged
7.
J Clin Gastroenterol ; 50(3): 233-8, 2016 Mar.
Article in English | MEDLINE | ID: mdl-26501882

ABSTRACT

INTRODUCTION: Colonoscopic surveillance guidelines for serrated polyps (SPs) are predicated upon the histologic characteristics of the index polyp. However, discrimination between SP subtypes [hyperplastic polyps vs. sessile serrated adenoma/polyps (SSA/P)] is often unreliable. MATERIALS AND METHODS: We studied the impact of (1) a novel tissue orientation method, performed in the endoscopy laboratory, whereby polyps are flattened in a small paper envelope immediately after resection (modified protocol); and (2) 2012 consensus-modified criteria (CM-2012). These interventions were compared with conventional tissue-handling protocol (CP) and traditional 2008 World Health Organization criteria (WHO). Twenty blinded community pathologists from around the United States scored 100, independent, 0.5 to 2.0 cm, proximal colonic SPs randomly selected from a 2-site tissue section archive. We compared interobserver agreement and diagnostic grading. RESULTS: Interobserver agreement was higher using CM-2012 than WHO criteria (absolute agreement: 13% vs. 4%, P<0.01; 75% agreement: 54% vs. 38%, P<0.01). Interobserver agreement was higher with the modified protocol than with CP (WHO absolute agreement: 6% vs. 2%, P>0.05; WHO 75% agreement: 46% vs. 30%, P>0.05, and CM-2012 absolute agreement: 20% vs. 6%, P=0.07; CM-2012 75% agreement: 66% vs. 42%, P=0.03). Compared with WHO, use of CM-2012 criteria resulted in fewer diagnoses of "indeterminate"; more diagnoses of SSA/P (P<0.01); and "upgraded" the diagnosis from hyperplastic polyps to SSA/P in approximately 7% of cases. These observations were independent of polyp size, patient gender, and study site. CONCLUSIONS: Simple enhancements to postresection SP handling and diagnostic criteria markedly improve interobserver agreement of SP diagnosis among nongastrointestinal community pathologists. This finding, if confirmed, has important implications for SP colonoscopy surveillance guidelines.


Subject(s)
Adenoma/pathology , Colonic Neoplasms/pathology , Colonic Polyps/pathology , Histological Techniques/methods , Specimen Handling/methods , Female , Histological Techniques/standards , Humans , Male , Observer Variation , Pathology, Clinical/methods , Pathology, Clinical/standards , Practice Guidelines as Topic , Professional Practice Location , Single-Blind Method , Specimen Handling/standards
8.
Clin Gastroenterol Hepatol ; 14(4): 568-74, 2016 Apr.
Article in English | MEDLINE | ID: mdl-26499926

ABSTRACT

BACKGROUND & AIMS: As many as 50% of large sessile serrated adenomas/polyps (SSPs) are removed incompletely, which is significant because SSPs have been implicated in the development of interval cancers. It is unclear if endoscopic mucosal resection (EMR) is an optimal method for removal of SSPs. We assessed the efficacy and safety of removal of SSPs 10 mm and larger using a standardized inject-and-cut EMR technique. METHODS: We performed a retrospective analysis of colonoscopy data, collected over 7 years (2007-2013) at 2 centers, from 199 patients with proximal colon SSPs 10 mm and larger (251 polyps) removed by EMR by 4 endoscopists. The primary outcome measure was local recurrence. The secondary outcome measure was safety. RESULTS: At the index colonoscopy, patients had a median of 1 serrated lesion (range, 1-12) and 1 nonserrated neoplastic lesion (range, 0-15). The mean SSP size was 15.9 ± 5.3 mm; most were superficially elevated (84.5%) and located in the ascending colon (51%), and 3 SSPs (1.2%) had dysplasia. Surveillance colonoscopies were performed on 138 patients (69.3%) over a mean follow-up period of 25.5 ± 17.4 months. Of these patients, 5 had local recurrences (3.6%; 95% confidence interval, 0.5%-6.7%), detected after 17.8 ± 15.4 months, with a median size of 4 mm. No patients developed postprocedural bleeding, perforation, or advanced colon cancer, or had a death related to the index colorectal lesion during the study period. CONCLUSIONS: Inject-and-cut EMR is a safe and effective technique for the resection of SSPs. Less than 5% of patients have a local recurrence, which is usually small and can be treated endoscopically.


Subject(s)
Colonic Neoplasms/surgery , Colonoscopy/methods , Endoscopy/methods , Polyps/surgery , Adult , Aged , Aged, 80 and over , Colonoscopy/adverse effects , Endoscopy/adverse effects , Female , Humans , Male , Middle Aged , Retrospective Studies , Treatment Outcome
9.
J Urol ; 195(4 Pt 1): 1110-1117, 2016 04.
Article in English | MEDLINE | ID: mdl-26626214

ABSTRACT

PURPOSE: Intraoperative optical biopsy technologies may aid in the identification of important anatomical landmarks and improve surgical outcomes of robotic assisted radical prostatectomy. We evaluate the feasibility of confocal laser endomicroscopy during robotic assisted radical prostatectomy. MATERIALS AND METHODS: A total of 21 patients with biopsy proven prostate cancer scheduled for robotic assisted radical prostatectomy were recruited. After intravenous administration of fluorescein 15 patients underwent in vivo intraoperative confocal laser endomicroscopy of prostatic and periprostatic structures using a 2.6 or 0.85 mm imaging probe. Standard robotic instruments were used to grasp and maneuver the confocal laser endomicroscopy probes for image acquisition. Confocal laser endomicroscopy imaging was performed ex vivo on fresh prostate specimens from 20 patients. Confocal video sequences acquired in vivo and ex vivo were reviewed and analyzed, with additional image processing using a mosaicing algorithm. Processed confocal images were compared with standard hematoxylin and eosin analysis of imaged regions. RESULTS: Confocal laser endomicroscopy was successfully integrated with robotic surgery, including co-registration of confocal video sequences with white light and probe handling with standard robotic instrumentation. Intraoperative confocal laser endomicroscopy imaging of the neurovascular bundle before and after nerve sparing dissection revealed characteristic features including dynamic vascular flow and intact axon fibers. Ex vivo confocal imaging of the prostatic parenchyma demonstrated normal prostate glands, stroma and prostatic carcinoma. CONCLUSIONS: We report the initial feasibility of optical biopsy of prostatic and periprostatic tissue during robotic assisted radical prostatectomy. Image guidance and tissue interrogation using confocal laser endomicroscopy offer a new intraoperative imaging method that has the potential to improve the functional and oncologic outcomes of prostate cancer surgery.


Subject(s)
Biopsy/methods , Prostate/pathology , Prostatectomy/methods , Prostatic Neoplasms/pathology , Robotic Surgical Procedures/methods , Aged , Feasibility Studies , Humans , Male , Microscopy, Confocal/methods , Middle Aged , Prostatic Neoplasms/surgery
10.
J Endourol ; 29(12): 1418-23, 2015 Dec.
Article in English | MEDLINE | ID: mdl-26413927

ABSTRACT

PURPOSE: Tissue diagnosis of upper tract urothelial carcinoma (UTUC) is limited by variance in tumor sampling by standard ureteroscopic biopsy. Optical imaging technologies can potentially improve UTUC diagnosis, surveillance, and endoscopic treatment. We previously demonstrated in vivo optical biopsy of urothelial carcinoma of the bladder using confocal laser endomicroscopy (CLE). In this study, we evaluated a new 0.85-mm imaging probe in the upper urinary tract and demonstrated feasibility and compatibility with standard ureteroscopes to achieve in vivo optical biopsy of UTUC. MATERIALS AND METHODS: Fourteen patients scheduled for ureteroscopy of suspected upper tract lesions or surveillance of UTUC were recruited. After intravenous (IV) administration of fluorescein, CLE was performed using a 0.85-mm-diameter imaging probe inserted through the working channel of standard ureteroscopes. Acquired confocal video sequences were reviewed and analyzed. A mosaicing algorithm was used to compile a series of images into a single larger composite image. Processed CLE images were compared with standard histopathologic analysis. RESULTS: Optical biopsy of the UTUC using CLE was effectively achieved during standard ureteroscopy. There were no adverse events related to IV fluorescein administration or image acquisition. Confocal imaging of UTUC showed characteristic features similar to urothelial carcinoma of the bladder, including papillary structure, fibrovascular stalks, and pleomorphism. Lamina propria in normal areas of the renal pelvis and ureter was also identified. CONCLUSIONS: We report an initial feasibility of CLE of UTUC. Pending further clinical investigation, CLE may become a useful adjunct to ureteroscopic biopsy, endoscopic ablation, and surveillance of UTUC.


Subject(s)
Carcinoma, Transitional Cell/pathology , Intravital Microscopy/methods , Kidney Neoplasms/pathology , Kidney Pelvis/pathology , Ureteral Neoplasms/pathology , Ureteroscopy/methods , Aged , Aged, 80 and over , Female , Humans , Male , Microscopy, Confocal/methods , Middle Aged , Pilot Projects , Ureter/pathology
11.
Endoscopy ; 47(3): 200-6, 2015 Mar.
Article in English | MEDLINE | ID: mdl-25264764

ABSTRACT

BACKGROUND AND STUDY AIMS: The learning curve for optical diagnosis of colorectal polyps with the narrow-band imaging (NBI) is unknown. To forego histological analysis of diminutive polyps diagnosed optically with high confidence, guidelines recommend ≥ 90 % negative predictive value (NPV) and concordance of ≥ 90 % for surveillance intervals predicted optically and histologically. We aimed to study the learning of optical diagnosis for colorectal polyps. PATIENTS AND METHODS: We studied five endoscopists as part of a randomized multisite trial comparing near-focus and standard-focus views for optical diagnosis. They trained using a computer-based module, followed by 10 real-time colonoscopies with pathology correlation. Endoscopists then optically diagnosed and resected all the polyps found during 558 consecutive colonoscopies, and diagnoses were compared with pathology. Endoscopists repeated the training module at the study midpoint. NPV and concordance of surveillance intervals for diminutive polyps diagnosed optically with high confidence were measured over time. RESULTS: Endoscopists showed high diagnostic performance, with a nonsignificant trend toward higher NPV in the second half of the study. For the 445 polyps in the standard-view arm, the NPV was 88.0 % (95 %CI 75.7 % - 95.5 %) in the first half and 95.8 % (88.3 % - 99.1 %) in the second; P = 0.7. Three endoscopists in the first half and four in the second achieved > 90 % NPV. Concordance of surveillance intervals was identical in the first and second halves at 98.1 % (95 %CI 93.3 % - 99.8 %). CONCLUSIONS: High NPV for the prediction of non-neoplasms with NBI was achieved and maintained in this group of endoscopists who participated in standardized and continued training. Both NPV and surveillance interval agreement indicated high performance in the optical diagnosis of colorectal polyps and exceeded thresholds.


Subject(s)
Adenoma/diagnosis , Clinical Competence , Colonic Polyps/diagnosis , Colonoscopy , Colorectal Neoplasms/diagnosis , Education, Medical, Continuing , Narrow Band Imaging/standards , Adenoma/pathology , Adult , Aged , Aged, 80 and over , Colonic Polyps/pathology , Colorectal Neoplasms/pathology , Computer Simulation , Female , Humans , Learning Curve , Male , Memory, Episodic , Middle Aged , Narrow Band Imaging/methods , Population Surveillance , Predictive Value of Tests , Single-Blind Method
12.
Gut ; 64(10): 1569-77, 2015 Oct.
Article in English | MEDLINE | ID: mdl-25387891

ABSTRACT

BACKGROUND: Diminutive (≤ 5 mm) colorectal polyps are common, and overwhelmingly benign. Routinely, after polypectomy, they are examined pathologically to determine the surveillance intervals. Advances in equipment and techniques, such as narrow-band imaging (NBI) colonoscopy, now permit reliable real-time optical diagnosis. METHODS: We conducted a randomised single-masked study involving three institutions to determine whether optical diagnosis of diminutive colorectal polyps meets clinical practice standards and reduces the need for histopathology. We randomly assigned eligible patients undergoing routine high-definition colonoscopy to optical diagnosis using near focus versus standard view, using computer-generated block sequence. By validated criteria, we rendered an optical diagnosis and a confidence level (high vs low) for all polyps, using NBI. Our primary endpoint was the number of accurate high-confidence optical diagnoses compared with central blinded pathology in the two groups. We analysed data using intention to treat. FINDINGS: We enrolled 558 subjects, and randomly assigned 281 to near focus and 277 to standard view optical diagnosis. We detected 1309 predominantly diminutive (74.5%) and neoplastic (60.0%) polyps. Endoscopists were significantly more likely, OR 2.2 (95% CI 1.6 to 3.0, p<0.0001), to make a high-confidence optical diagnosis with near focus (85.1%) than standard (72.6%) view. High-confidence diagnoses had 96.4% and 92.0% negative predictive value, respectively. Of all polyps, 75.3% (95% CI71.3% to 78.9%) had a high-confidence accurate prediction using near focus, compared with 63.1% (95% CI 58.5% to 67.6%) using standard view. Optical versus histopathological diagnosis showed excellent agreement between the surveillance intervals, 93.5% in near focus and 92.2% in standard view. The median diagnosis time was 14 s. CONCLUSIONS: Real-time optical diagnosis using NBI colonoscopy may replace the pathology diagnosis for the majority of diminutive colorectal polyps. Using colonoscopy with near focus view increases the confidence level of the optical diagnosis. Optical diagnosis would be a paradigm shift in clinical practice of colonoscopy for colorectal cancer screening. TRIAL REGISTRATION NUMBER: ClinicalTrials.gov Identifier: NCT01288833.


Subject(s)
Colonic Polyps/diagnosis , Colonoscopy/methods , Colorectal Neoplasms/diagnosis , Narrow Band Imaging/methods , Diagnosis, Differential , Follow-Up Studies , Humans , Predictive Value of Tests , Retrospective Studies , Single-Blind Method
13.
Sci Transl Med ; 6(260): 260ra148, 2014 Oct 29.
Article in English | MEDLINE | ID: mdl-25355698

ABSTRACT

A combination of optical imaging technologies with cancer-specific molecular imaging agents is a potentially powerful strategy to improve cancer detection and enable image-guided surgery. Bladder cancer is primarily managed endoscopically by white light cystoscopy with suboptimal diagnostic accuracy. Emerging optical imaging technologies hold great potential for improved diagnostic accuracy but lack imaging agents for molecular specificity. Using fluorescently labeled CD47 antibody (anti-CD47) as molecular imaging agent, we demonstrated consistent identification of bladder cancer with clinical grade fluorescence imaging systems, confocal endomicroscopy, and blue light cystoscopy in fresh surgically removed human bladders. With blue light cystoscopy, the sensitivity and specificity for CD47-targeted imaging were 82.9 and 90.5%, respectively. We detected variants of bladder cancers, which are diagnostic challenges, including carcinoma in situ, residual carcinoma in tumor resection bed, recurrent carcinoma following prior intravesical immunotherapy with Bacillus Calmette-Guérin (BCG), and excluded cancer from benign but suspicious-appearing mucosa. CD47-targeted molecular imaging could improve diagnosis and resection thoroughness for bladder cancer.


Subject(s)
CD47 Antigen/immunology , Endoscopy , Urinary Bladder Neoplasms/diagnosis , CD47 Antigen/genetics , Humans , RNA, Messenger/genetics , Urinary Bladder Neoplasms/immunology , Urinary Bladder Neoplasms/surgery
14.
ACG Case Rep J ; 2(1): 24-6, 2014 Oct.
Article in English | MEDLINE | ID: mdl-26157896

ABSTRACT

Severe thrombocytopenia is a contraindication for therapeutic endoscopy due to the risk of bleeding. Platelet transfusions can temporarily increase platelet count, but are difficult to administer in the 2 weeks following endoscopic resection, during which the patient is at high risk for delayed bleeding. We present the use of a novel thrombopoietin receptor agonist, eltrombopag, to sustain platelet levels for the safe and complete endoscopic submucosal dissection of a gastric carcinoid in a patient with severe thrombocytopenia due to cirrhosis and idiopathic thrombocytopenic purpura. We performed complete and safe endoscopic removal of a gastric carcinoid after correcting the thrombocytopenia.

15.
Endoscopy ; 45(11): 897-905, 2013 Nov.
Article in English | MEDLINE | ID: mdl-24165815

ABSTRACT

BACKGROUND AND STUDY AIMS: Surveillance intervals after colonoscopic resection of serrated polyps are partially predicated on the histology of the polyp(s) removed during the index exam. Histologic discrimination between sessile serrated adenomas/polyps (SSA/P) and hyperplastic polyps is challenging. We devised and tested a simple tool--an envelope--that gastroenterologists can integrate into routine colonoscopy practice to address this problem. METHODS: In the "modified protocol," immediately after polypectomy each serrated polyp was flattened and enclosed in a paper envelope before being placed in formalin. In the pathology laboratory, each polyp was sectioned after processing. A two-site, prospective, randomized, single-blinded trial was performed to compare this modified protocol with the conventional protocol. Serrated polyps located proximal to the splenic flexure and 5-20 mm in diameter were included. A novel orientation score that measured the number of well-oriented crypts per unit area of polyp (higher orientation score = better orientation) was validated. Orientation score, SSA/P diagnosis rate, and inter-pathologist agreement were measured. RESULTS: A total of 375 polyps were enrolled, of which 264 were identified for analysis. The mean orientation scores in the modified and conventional protocol groups were 3.11 and 1.13, respectively (P < 0.0001). SSA/Ps were diagnosed in 103/135 cases (76.3%) in the modified protocol group vs. 54/129 (41.9%) in the conventional protocol group (P < 0.0001). Inter-pathologist agreement was higher with the modified than the conventional protocol (77.0% vs. 62.8%; P = 0.015). CONCLUSION: Standard polyp handling techniques may be sub-optimal for interpretation of serrated polyps resected at colonoscopy, and may lead to inadvertent histologic "under-grading" of many lesions. Our intervention improved histopathologic interpretation and increased the SSA/P diagnosis rate.


Subject(s)
Adenomatous Polyps/pathology , Colonic Polyps/pathology , Colonoscopy , Intestinal Mucosa/pathology , Specimen Handling/methods , Aged , Biopsy , Diagnosis, Differential , Female , Humans , Male , Middle Aged , Observer Variation , Single-Blind Method , Specimen Handling/instrumentation
17.
Surg Endosc ; 27(8): 2692-703, 2013 Aug.
Article in English | MEDLINE | ID: mdl-23392988

ABSTRACT

BACKGROUND: Colorectal adenocarcinoma with depth of invasion ≤1,000 µm from the muscularis mucosa and favorable histology is now considered for local resection. We aimed to examine the strength of evidence for this emerging practice. METHODS: We searched Medline, Scopus, and Cochrane (1950-2011), then performed a meta-analysis on the risk of lymph node metastasis in nonpedunculated (sessile and nonpolypoid) T1 colorectal cancers. We included studies with nonpedunculated lesions, actual invasion depth, and pathologic factors of interest. Synchronous, polyposis or secondary cancers, and chemoradiation studies were excluded. Our primary outcome was the risk of LNM. We analyzed using Review Manager; we estimated heterogeneity using Cochran Q χ(2) test and I (2). We generated summary risk ratios using a random effects model, performed sensitivity analyses, and evaluated the quality of evidence using GRADEPro. RESULTS: We identified 209 articles; 5 studies (n = 1213 patients) met the inclusion criteria. The risk of LNM in nonpedunculated ≤1,000 µm is 1.9 % (95 % confidence interval 0.5-4.8 %). The risk for all T1 is 13 % (95 % confidence interval 11.5-15.4 %). Characteristics protective against LNM were ≤1,000 µm invasion, well differentiation, absence of lymphatic and vascular invasion, and absence of tumor budding. We did not detect significant study heterogeneity. The quality of evidence was poor. CONCLUSIONS: Well-differentiated nonpedunculated T1 colorectal cancer invasive into the submucosa ≤1,000 µm, without lymphovascular involvement or tumor budding, has the lowest risk of nodal metastasis. Importantly, the risk was not zero (1.9 %), and the qualitative formal analysis of data was not strong. As such, endoscopic resection alone may be adequate in select patients with submucosal invasive colorectal cancers, but more studies are needed. Overall, the quality of evidence was poor; data were from small retrospective studies from limited geographic regions.


Subject(s)
Colorectal Neoplasms/secondary , Intestinal Mucosa/pathology , Lymphatic Metastasis , Neoplasm Staging , Colorectal Neoplasms/diagnosis , Humans , Neoplasm Invasiveness
18.
Mol Plant ; 6(2): 301-10, 2013 Mar.
Article in English | MEDLINE | ID: mdl-23292880

ABSTRACT

Huanglongbing (HLB) is a devastating citrus disease that is associated with bacteria of the genus 'Candidatus Liberibacter' (Ca. L.). Powerful diagnostic tools and management strategies are desired to control HLB. Host small RNAs (sRNA) play a vital role in regulating host responses to pathogen infection and are used as early diagnostic markers for many human diseases, including cancers. To determine whether citrus sRNAs regulate host responses to HLB, sRNAs were profiled from Citrus sinensis 10 and 14 weeks post grafting with Ca. L. asiaticus (Las)-positive or healthy tissue. Ten new microRNAs (miRNAs), 76 conserved miRNAs, and many small interfering RNAs (siRNAs) were discovered. Several miRNAs and siRNAs were highly induced by Las infection, and can be potentially developed into early diagnosis markers of HLB. miR399, which is induced by phosphorus starvation in other plant species, was induced specifically by infection of Las but not Spiroplasma citri that causes citrus stubborn-a disease with symptoms similar to HLB. We found a 35% reduction of phosphorus in Las-positive citrus trees compared to healthy trees. Applying phosphorus oxyanion solutions to HLB-positive sweet orange trees reduced HLB symptom severity and significantly improved fruit production during a 3-year field trial in south-west Florida. Our molecular, physiological, and field data suggest that phosphorus deficiency is linked to HLB disease symptomology.


Subject(s)
Citrus sinensis/metabolism , Citrus sinensis/microbiology , Phosphorus/deficiency , Plant Diseases/microbiology , RNA, Plant/genetics , RNA, Untranslated/genetics , Citrus sinensis/genetics , Citrus sinensis/growth & development , Fruit/drug effects , Fruit/growth & development , MicroRNAs/genetics , Phosphorus/pharmacology , Rhizobiaceae/physiology
19.
J Endourol ; 27(5): 598-603, 2013 May.
Article in English | MEDLINE | ID: mdl-23072435

ABSTRACT

BACKGROUND AND PURPOSE: Emerging optical imaging technologies such as confocal laser endomicroscopy (CLE) hold promise in improving bladder cancer diagnosis. The purpose of this study was to determine the interobserver agreement of image interpretation using CLE for bladder cancer. METHODS: Experienced CLE urologists (n=2), novice CLE urologists (n=6), pathologists (n=4), and nonclinical researchers (n=5) were recruited to participate in a 2-hour computer-based training consisting of a teaching and validation set of intraoperative white light cystoscopy (WLC) and CLE video sequences from patients undergoing transurethral resection of bladder tumor. Interobserver agreement was determined using the κ statistic. RESULTS: Of the 31 bladder regions analyzed, 19 were cancer and 12 were benign. For cancer diagnosis, experienced CLE urologists had substantial agreement for both CLE and WLC+CLE (90%, κ 0.80) compared with moderate agreement for WLC alone (74%, κ 0.46), while novice CLE urologists had moderate agreement for CLE (77%, κ 0.55), WLC (78%, κ 0.54), and WLC+CLE (80%, κ 0.59). Pathologists had substantial agreement for CLE (81%, κ 0.61), and nonclinical researchers had moderate agreement (77%, κ 0.49) in cancer diagnosis. For cancer grading, experienced CLE urologists had fair to moderate agreement for CLE (68%, κ 0.64), WLC (74%, κ 0.67), and WLC+CLE (53%, κ 0.33), as did novice CLE urologists for CLE (53%, κ 0.39), WLC (66%, κ 0.50), and WLC+CLE (61%, κ 0.49). Pathologists (65%, κ 0.55) and nonclinical researchers (61%, κ 0.56) both had moderate agreement for CLE in cancer grading. CONCLUSIONS: CLE is an adoptable technology for cancer diagnosis in novice CLE observers after a short training with moderate interobserver agreement and diagnostic accuracy similar to WLC alone. Experienced CLE observers may be capable of achieving substantial levels of agreement for cancer diagnosis that is higher than with WLC alone.


Subject(s)
Cystoscopy , Microscopy, Confocal/statistics & numerical data , Urinary Bladder Neoplasms/pathology , Humans , Microscopy, Confocal/methods , Observer Variation , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...