Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Phys Med Biol ; 53(19): 5385-404, 2008 Oct 07.
Article in English | MEDLINE | ID: mdl-18765889

ABSTRACT

The beta-microprobe is a simple and versatile technique complementary to small animal positron emission tomography (PET). It relies on local measurements of the concentration of positron-labeled molecules. So far, it has been successfully used in anesthetized rats for pharmacokinetics experiments and for the study of brain energetic metabolism. However, the ability of the technique to provide accurate quantitative measurements using (18)F, (11)C and (15)O tracers is likely to suffer from the contribution of 511 keV gamma rays background to the signal and from the contribution of positrons from brain loci surrounding the locus of interest. The aim of the present paper is to provide a method of evaluating several parameters, which are supposed to affect the quantification of recordings performed in vivo with this methodology. We have developed realistic voxelized phantoms of the rat whole body and brain, and used them as input geometries for Monte Carlo simulations of previous beta-microprobe reports. In the context of realistic experiments (binding of (11)C-Raclopride to D2 dopaminergic receptors in the striatum; local glucose metabolic rate measurement with (18)F-FDG and H(2)O(15) blood flow measurements in the somatosensory cortex), we have calculated the detection efficiencies and corresponding contribution of 511 keV gammas from peripheral organs accumulation. We confirmed that the 511 keV gammas background does not impair quantification. To evaluate the contribution of positrons from adjacent structures, we have developed beta-Assistant, a program based on a rat brain voxelized atlas and matrices of local detection efficiencies calculated by Monte Carlo simulations for several probe geometries. This program was used to calculate the 'apparent sensitivity' of the probe for each brain structure included in the detection volume. For a given localization of a probe within the brain, this allows us to quantify the different sources of beta signal. Finally, since stereotaxic accuracy is crucial for quantification in most microprobe studies, the influence of stereotaxic positioning error was studied for several realistic experiments in favorable and unfavorable experimental situations (binding of (11)C-Raclopride to D2 dopaminergic receptors in the striatum; binding of (18)F-MPPF to 5HT1A receptors in the dorsal raphe nucleus).


Subject(s)
Brain/metabolism , Models, Anatomic , Monte Carlo Method , Radioisotopes/metabolism , Uncertainty , Animals , Carbon Radioisotopes/chemistry , Electrons , Fluorodeoxyglucose F18/metabolism , Oxygen Radioisotopes/metabolism , Raclopride/chemistry , Raclopride/metabolism , Rats , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...