1.
J Card Fail ; 2024 Jun 06.
Article in English | MEDLINE | ID: mdl-38851449

ABSTRACT

BACKGROUND: Prediction of outcomes remains an unmet need in LVAD candidates. Development of right heart failure portends an excess in mortality but imaging parameters of right ventricular systolic function have failed to demonstrate a prognostic role. By integrating pulmonary pressure, right ventriculoarterial coupling could fill this gap. METHODS: The ASSIST-ICD registry was used to test right ventriculoarterial coupling surrogate parameters at implantation for the prediction of all-cause mortality. RESULTS: The ratio of the tricuspid annular plane systolic excursion over the estimated systolic pulmonary pressure (TAPSE/sPAP) was not associated with long-term survival in univariate analysis (p = 0.89), neither was the pulmonary artery pulsatility index (PAPi) (p = 0.13). Conversely, the ratio of the right atrial pressure over the pulmonary capillary wedge pressure (RAP/PCWP) was associated with all-cause mortality (p <0.01). After taking tricuspid regurgitation severity, LVAD indication, LVAD model, age, blood urea nitrogen, and pulmonary vascular resistance into account, RAP/PCWP remained associated with survival (HR 1.35 [1.10 - 1.65], p <0.01). CONCLUSION: Among pre-implant RVAC surrogates, only RAP/PCWP was associated with long-term all-cause mortality in LVAD recipients. This association was independent of established risk factors.

2.
ESC Heart Fail ; 2024 Apr 05.
Article in English | MEDLINE | ID: mdl-38581135

ABSTRACT

AIMS: Right ventricular failure after left ventricular assist device (LVAD) implantation is a major concern that remains challenging to predict. We sought to investigate the relationship between preoperative pulmonary artery pulsatility index (PAPi) and mortality after LVAD implantation. METHODS AND RESULTS: A retrospective analysis of the ASSIST-ICD multicentre registry allowed the assessment of PAPi before LVAD according to the formula [(systolic pulmonary artery pressure - diastolic pulmonary artery pressure)/central venous pressure]. The primary endpoint was survival at 3 months, according to the threshold value of PAPi determined by the receiver operating characteristic (ROC) curve. A multivariate analysis including demographic, echographic, haemodynamic, and biological variables was performed to identify predictive factors for 2 year mortality. One hundred seventeen patients were included from 2007 to 2021. The mean age was 58.45 years (±13.16), with 15.4% of women (sex ratio 5.5). A total of 53.4% were implanted as bridge to transplant and 43.1% as destination therapy. Post-operative right ventricular failure was observed in 57 patients (48.7%), with no significant difference between survivors and non-survivors at 1 month (odds ratio 1.59, P = 0.30). The median PAPi for the whole study population was 2.83 [interquartile range 1.63-4.69]. The threshold value of PAPi determined by the ROC curve was 2.84. Patients with PAPi ≥ 2.84 had a higher survival rate at 3 months [PAPi < 2.84: 58.1% [46.3-72.8%] vs. PAPi ≥ 2.84: 89.1% [81.1-97.7%], hazard ratio (HR) 0.08 [0.02-0.28], P < 0.01], with no significant difference after 3 months (HR 0.67 [0.17-2.67], P = 0.57). Other predictors of 2 year mortality were systemic hypertension (HR 4.22 [1.49-11.97], P < 0.01) and diabetes mellitus (HR 4.90 [1.83-13.14], P < 0.01). LVAD implantation as bridge to transplant (HR 0.18 [0.04-0.74], P = 0.02) and heart transplantation (HR 0.02 [0.00-0.18], P < 0.01) were associated with a higher survival rate at 2 years. CONCLUSIONS: Preoperative PAPi < 2.84 was associated with a higher risk of early mortality after LVAD implantation without impacting 2 year outcomes among survivors.

4.
Crit Care Med ; 50(5): e426-e433, 2022 05 01.
Article in English | MEDLINE | ID: mdl-34974497

ABSTRACT

OBJECTIVES: Temporary circulatory support (TCS) as a bridge-to-left ventricular assist device (BTL) in cardiogenic shock patients has been increasing, but limited data exists on this BTL strategy. We aimed at analyzing the outcome of BTL patients in a population of cardiogenic shock patients compared with those without TCS at the time of the left ventricular assist device (LVAD) surgery and identify predictors of postoperative mortality in this specific population. DESIGN: A multicenter retrospective observational study conducted in 19 centers from 2006 to 2016. SETTING: Nineteen French centers. PATIENTS: A total of 329 cardiogenic shock patients at the time of LVAD implantation were analyzed. Patients were divided in three groups: those under TCS at the time of LVAD implantation (n = 173), those with TCS removal before LVAD surgery (n = 24), and those who did not undergo a bridging strategy (n = 152). Primary endpoint was 30-day mortality. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Among the BTL group, 68 (39.3%), 18 (10.4%), and 15 (8.7%) patients were under venoarterial extracorporeal membrane oxygenation, Impella, and IABP support alone, and 72 patients (20.6%) were under multiple TCS support. BTL patients presented similar 30 days survival compared with the TCS removal and non-BTL groups. However, BTL group had a significantly longer ICU duration stay, with two-fold duration of mechanical ventilation time, but the three groups experienced similar postoperative complications. Multivariate analysis identified three independent predictors of mortality in the BTL group: combined surgery with LVAD, body mass index (BMI), and heart failure (HF) duration. BTL strategy was not an independent predictor of mortality in cardiogenic shock patients who underwent LVAD. CONCLUSIONS: BTL strategy is not associated with a lower survival among cardiogenic shock patients with LVAD implantation. Predictors of mortality are combined surgery with LVAD, higher BMI, and HF duration.


Subject(s)
Extracorporeal Membrane Oxygenation , Heart Failure , Heart-Assist Devices , Extracorporeal Membrane Oxygenation/adverse effects , Heart Failure/complications , Heart Failure/surgery , Heart-Assist Devices/adverse effects , Humans , Retrospective Studies , Shock, Cardiogenic/etiology , Shock, Cardiogenic/surgery , Treatment Outcome
5.
ESC Heart Fail ; 8(6): 5159-5167, 2021 12.
Article in English | MEDLINE | ID: mdl-34494391

ABSTRACT

AIMS: Despite regularly updated guidelines, there is still a delay in referral of advanced heart failure patients to mechanical circulatory support and transplant centres. We aimed to analyse characteristics and outcome of non-inotrope-dependent patients implanted with a left ventricular assist device (LVAD). METHODS AND RESULTS: The ASSIST-ICD registry collected LVAD data in 19 centres in France between February 2006 and December 2016. We used data of patients in Interagency Registry for Mechanically Assisted Circulatory Support Classes 4-7. The primary endpoint was survival analysis. Predictors of mortality were searched with multivariable analyses. A total of 303 patients (mean age 61.0 ± 9.9 years, male sex 86.8%) were included in the present analysis. Ischaemic cardiomyopathy was the leading heart failure aetiology (64%), and bridge to transplantation was the main implantation strategy (56.1%). The overall likelihood of being alive while on LVAD support or having a transplant at 1, 2, 3, and 5 years was 66%, 61.7%, 58.7%, and 55.1%, respectively. Age [hazard ratio (HR) 1.03, 95% confidence interval (CI) 1.00-1.05; P = 0.02], a concomitant procedure (HR 2.32, 95% CI 1.52-3.53; P < 0.0001), and temporary mechanical right ventricular support during LVAD implantation (HR 2.94, 95% CI 1.49-5.77; P = 0.002) were the only independent variables associated with mortality. Heart failure medications before or after LVAD implantation were not associated with survival. CONCLUSION: Ambulatory heart failure patients displayed unsatisfactory survival rates after LVAD implantation. A better selection of patients who can benefit from LVAD may help improving outcomes.


Subject(s)
Heart Failure , Heart-Assist Devices , Aged , Heart Failure/complications , Heart Failure/therapy , Humans , Male , Middle Aged , Registries , Survival Rate , Treatment Outcome
6.
Future Sci OA ; 7(4): FSO689, 2021 Feb 15.
Article in English | MEDLINE | ID: mdl-33815827

ABSTRACT

BACKGROUND: Novel oral anticoagulants are used in atrial fibrillation. Idarucizumab has been approved for reversal of dabigatran in situations of life-threatening hemorrhage or emergency surgery. OBJECTIVES: We report a single center experience of ten patients on dabigatran therapy who were given idarucizumab prior to heart transplantation. METHODS & RESULTS: The mean plasma concentration of dabigatran prior to reversal was 139 ± 89 ng/ml. Hemoglobin, hematocrit and platelet levels were decreased after surgery. Surgical procedures were successfully performed with no increased risk, especially regarding bleeding complications. All patients were alive after 90 days. CONCLUSION: Dabigatran reversal with idarucizumab in contexts of emergency surgery/urgent procedures is an attractive and safe option to be taken into consideration for patients with end stage heart disease awaiting transplantation and indication of anticoagulant therapy.

7.
Am J Cardiol ; 146: 82-88, 2021 05 01.
Article in English | MEDLINE | ID: mdl-33549526

ABSTRACT

LVAD implantation in patients with a recently diagnosed cardiomyopathy has been poorly investigated. This work aims at describing the characteristics and outcomes of patients receiving a LVAD within 30 days following the diagnosis of cardiomyopathy. Patients from the ASSIST-ICD study was divided into recently and remotely diagnosed cardiomyopathy based on the time from initial diagnosis of cardiomyopathy to LVAD implantation using the cut point of 30 days. The primary end point of the study was all-cause mortality at 30-day and during follow-up. A total of 652 patients were included and followed during a median time of 9.1 (2.5 to 22.1) months. In this population, 117 (17.9%) had a recently diagnosed cardiomyopathy and had LVAD implantation after a median time of 15.0 (9.0 to 24.0) days following the diagnosis. This group of patients was significantly younger, with more ischemic cardiomyopathy, more sudden cardiac arrest (SCA) events at the time of the diagnosis and were more likely to receive temporary mechanical support before LVAD compared with the remotely diagnosed group. Postoperative in-hospital survival was similar in groups, but recently diagnosed patients had a better long-term survival after hospital discharge. SCA before LVAD and any cardiac surgery combined with LVAD implantation were identified as 2 independent predictors of postoperative mortality in recently diagnosed patients. In conclusion, rescue LVAD implantation for recently diagnosed severe cardiomyopathy is common in clinical practice. Such patients experience a relatively low postoperative mortality and have a better long-term survival compared with remotely diagnosed patients.


Subject(s)
Cardiomyopathies/therapy , Heart-Assist Devices , Aged , Cardiomyopathies/diagnosis , Cardiomyopathies/mortality , Female , France/epidemiology , Humans , Male , Middle Aged , Prognosis , Prosthesis Design , Retrospective Studies , Survival Rate/trends
8.
Pan Afr Med J ; 37: 65, 2020.
Article in English | MEDLINE | ID: mdl-33244328

ABSTRACT

Rupture of Valsalva sinus remains a very rare and deadly complication of Valsalva sinus aneurysm with a high mortality rate. We report here the case of a 47-year-old man who presented to the emergency department with acute exercise-induced dyspnea, chest pain, and fever. Transthoracic (TTE) and transesophageal echocardiography (TEE) highlighted a rupture of the right Valsalva sinus in the right atrium due to infective endocarditis. After stabilization of the patient, a successful surgical repair with double pericardial patches was performed.


Subject(s)
Aortic Rupture/etiology , Endocarditis/complications , Sinus of Valsalva/diagnostic imaging , Aortic Aneurysm/diagnostic imaging , Aortic Aneurysm/etiology , Aortic Rupture/diagnostic imaging , Chest Pain/etiology , Echocardiography , Echocardiography, Transesophageal , Heart Atria/diagnostic imaging , Humans , Male , Middle Aged
9.
Am J Cardiol ; 133: 81-88, 2020 10 15.
Article in English | MEDLINE | ID: mdl-32861423

ABSTRACT

We aimed at characterizing the impact of low and high body mass index (BMI) on outcomes after left-ventricular assist device (LVAD) surgery and define the predictors of mortality in patients with abnormal BMI (low/high). This study was conducted in 19 centers from 2006 to 2016. Patients were divided based on their baseline BMI into 3 groups of BMI: low (BMI ≤18.5 kg/m²); normal (BMI = 18.5 to 24.99 kg/m²) and high (BMI ≥25 kg/m²) (including overweight (BMI = 25 to 29.99 kg/m²), and obesity (BMI ≥30 Kg/m²)). Among 652 patients, 29 (4.4%), 279 (42.8%) and 344 (52.8%) had a low-, normal-, and high BMI, respectively. Patients with high BMI were significantly more likely men, with more co-morbidities and more history of ventricular/supra-ventricular arrhythmias before LVAD implantation. Patients with abnormal BMI had significantly lower survival than those with normal BMI. Notably, those with low BMI experienced the worst survival whereas overweight or obese patients had similar survival. Four predictors of mortality for LVAD candidates with abnormal BMI were defined: total bilirubin ≥16 µmol/L before LVAD, hypertension, destination therapy, and cardiac surgery with LVAD. Depending on the number of predictor per patients, those with abnormal BMI may be divided in 3 groups of 1-year mortality risk, i.e., low (0 to 1 predictor: 29% and 31%), intermediate (2 to 3 predictors, 51% and 52%, respectively), and high (4 predictors: 83%). In conclusion, LVAD recipients with abnormal BMI experience lower survival, especially underweight patients. Four predictors of mortality have been identified for LVAD population with abnormal BMI, differentiating those a low-, intermediate-, and high risks of death.


Subject(s)
Body Mass Index , Heart Failure/therapy , Heart-Assist Devices , Obesity/complications , Thinness/complications , Aged , Female , Follow-Up Studies , Heart Failure/complications , Heart Failure/mortality , Humans , Male , Middle Aged , Obesity/mortality , Retrospective Studies , Risk Factors , Survival Rate , Thinness/mortality , Treatment Outcome
10.
Eur J Cardiothorac Surg ; 58(1): 112-120, 2020 07 01.
Article in English | MEDLINE | ID: mdl-32298439

ABSTRACT

OBJECTIVES: Our goal was to provide a picture of left ventricular assist device (LVAD) activity in France between 2007 and 2016 based on the multicentric ASSIST-ICD registry. METHODS: We retrospectively collected 136 variables including in-hospital data, follow-up survival rates and adverse events from 671 LVAD recipients at 20 out of 24 LVAD implant centres in France. The average follow-up time was 1.2 years (standard deviation: 1.4); the total follow-up time was 807.5 patient-years. RESULTS: The included devices were the HeartMate II®, HeartWare LVAS® or Jarvik 2000®. The overall likelihood of being alive while on LVAD support or having a transplant (primary end point) at 1, 2, 3 and 5 years postimplantation was 65.2%, 59.7%, 55.9% and 47.7%, respectively, given a cumulative incidence of 29.2% of receiving a transplant at year 5. At implantation, 21.5% of patients were on extracorporeal life support. The overall rate of cardiogenic shock at implantation was 53%. The major complications were driveline infection (26.1%), pump pocket or cannula infection (12.6%), LVAD thrombosis (12.2%), ischaemic (12.8%) or haemorrhagic stroke (5.4%; all strokes 18.2%), non-cerebral haemorrhage (9.1%) and LVAD exchange (5.2%). The primary end point (survival) was stratified by age at surgery and by the type of device used, with inference from baseline profiles. The primary end point combined with an absence of complications (secondary end point) was also stratified by device type. CONCLUSIONS: The ASSIST-ICD registry provides a real-life picture of LVAD use in 20 of the 24 implant centres in France. Despite older average age and a higher proportion of patients chosen for destination therapy, survival rates improved compared to those in previous national registry results. This LVAD registry contrasts with other international registries because patients with implants have more severe disease, and the national policy for graft attribution is distinct. We recommend referring patients for LVAD earlier and suggest a discussion of the optimal timing of a transplant for bridged patients (more dismal results after the second year of support?).


Subject(s)
Heart Failure , Heart-Assist Devices , France/epidemiology , Heart Failure/surgery , Heart-Assist Devices/adverse effects , Humans , Registries , Retrospective Studies , Treatment Outcome
11.
Am J Cardiol ; 125(9): 1421-1428, 2020 05 01.
Article in English | MEDLINE | ID: mdl-32145895

ABSTRACT

The impact of uncommon etiology cardiomyopathies on Left-ventricular assist device (LVAD)-recipient outcomes is not very well known. This study aimed to characterize patients with uncommon cardiomyopathy etiologies and examine the outcomes between uncommon and ischemic/idiopathic dilated cardiomyopathy. This observational study was conducted in 19 centers between 2006 and 2016. Baseline characteristics and outcomes of patients with uncommon etiology were compared to patients with idiopathic dilated/ischemic cardiomyopathies. Among 652 LVAD-recipients included, a total of 590 (90.5%) patients were classified as ischemic/idiopathic and 62 (9.5%) patients were classified in the "uncommon etiologies" group. Main uncommon etiologies were: hypertrophic (n = 12(19%)); cancer therapeutics-related cardiac dysfunction (CTRCD) (n = 12(19%)); myocarditis (n = 11(18%)); valvulopathy (n = 9(15%)) and others (n = 18(29%)). Patients with uncommon etiologies were significantly younger with more female and presented less co-morbidities. Additionally, patients with uncommon cardiomyopathies were less implanted as destination therapy compared with ischemic/idiopathic group (29% vs 38.8%). During a follow-up period of 9.1 months, both groups experienced similar survival. However, subgroup of hypertrophic/valvular cardiomyopathies and CTRCD had significantly higher mortality compared to the ischemic/idiopathic or myocarditis/others cardiomyopathies. Conversely, patients with myocarditis/others etiologies experienced a better survival. Indeed, the 12-months survival in the myocarditis/others; ischemic/idiopathic and hypertrophic/CTRCD/valvulopathy group were 77%; 65%, and 46% respectively. In conclusion, LVAD-recipients with hypertrophic cardiomyopathy, valvular heart disease and CTRCD experienced the higher mortality rate.


Subject(s)
Cardiomyopathy, Dilated/surgery , Cardiomyopathy, Hypertrophic/surgery , Heart-Assist Devices , Myocardial Ischemia/surgery , Adult , Aged , Cardiomyopathy, Dilated/etiology , Cardiomyopathy, Hypertrophic/etiology , Female , Humans , Male , Middle Aged , Myocardial Ischemia/etiology , Retrospective Studies , Treatment Outcome
12.
JACC Clin Electrophysiol ; 5(8): 944-954, 2019 08.
Article in English | MEDLINE | ID: mdl-31439296

ABSTRACT

OBJECTIVES: This study aimed to evaluate incidence, clinical significance, and predictors of early ventricular arrhythmias (VAs) in left ventricular assist device (LVAD) recipients. BACKGROUND: LVAD implantation is increasingly used in patients with end-stage heart failure. Early VAs may occur during the 30-day post-operative period, but many questions remain unanswered regarding their incidence and clinical impact. METHODS: This observational study was conducted in 19 centers between 2006 and 2016. Early VAs were defined as sustained ventricular tachycardia and/or ventricular fibrillation occurring <30 days post-LVAD implantation and requiring appropriate implantable cardioverter-defibrillator therapy, external electrical shock, or medical therapy. RESULTS: A total of 652 patients (median age: 59.8 years; left ventricular ejection fraction: 20.7 ± 7.4%; HeartMate 2: 72.8%; HeartWare: 19.5%; Jarvik 2000: 7.7%) were included in the analysis. Early VAs occurred in 162 patients (24.8%), most frequently during the first week after LVAD implantation. Multivariable analysis identified history of VAs prior to LVAD and any combined surgery with LVAD as 2 predictors of early VAs. The occurrence of early VAs with electrical storm was the strongest predictor of 30-day post-operative mortality, associated with a 7-fold increase of 30-day mortality. However, in patients discharged alive from hospital, occurrence of early VAs did not influence long-term survival. CONCLUSIONS: Early VAs are common after LVAD implantation and increase 30-day post-operative mortality, without affecting long-term survival. Further studies will be needed to analyze whether pre- or pre-operative ablation of VAs may improve post-operative outcomes. (Determination of Risk Factors of Ventricular Arrhythmias After Implantation of Continuous Flow Left Ventricular Assist Device With Continuous Flow Left Ventricular Assist Device [ASSIST-ICD]; NCT02873169).


Subject(s)
Arrhythmias, Cardiac , Heart Ventricles/physiopathology , Heart-Assist Devices , Postoperative Complications , Aged , Arrhythmias, Cardiac/epidemiology , Arrhythmias, Cardiac/mortality , Female , Heart Failure/therapy , Heart-Assist Devices/adverse effects , Heart-Assist Devices/statistics & numerical data , Humans , Male , Middle Aged , Postoperative Complications/epidemiology , Postoperative Complications/mortality , Retrospective Studies
13.
Heart Rhythm ; 16(10): 1506-1512, 2019 10.
Article in English | MEDLINE | ID: mdl-31255846

ABSTRACT

BACKGROUND: Ventricular arrhythmias (VAs) can occur after continuous flow left ventricular assist device (LVAD) implantation as a single arrhythmic event or as electrical storm (ES) with multiple repetitive VA episodes. OBJECTIVE: We aimed at analyzing the incidence, predictors, and clinical impact of ES in LVAD recipients. METHODS: Patients analyzed were those included in the multicenter ASSIST-ICD observational study. ES was consensually defined as occurrence of ≥3 separate episodes of sustained VAs within a 24-hour interval. RESULTS: Of 652 patients with an LVAD, 61 (9%) presented ES during a median follow-up period of 9.1 (interquartile range [IQR] 2.5-22.1) months. The first ES occurred after 17 (IQR 4.0-56.2) days post LVAD implantation, most of them during the first month after the device implantation (63%). The incidence then tended to decrease during the initial years of follow-up and increased again after the third year post LVAD implantation. History of VAs before LVAD implantation and heart failure duration > 84 months were independent predictors of ES. The occurrence of ES was associated with an increased early mortality since 20 patients (33%) died within the first 2 weeks of ES. Twenty-two patients (36.1%) presented at least 1 recurrence of ES, occurring 43.0 (IQR 8.0-69.0) days after the initial ES. Patients experiencing ES had a significantly lower 1-year survival rate than did those free from ES (log-rank, P = .039). CONCLUSION: There is a significant incidence of ES in patients with an LVAD. The short-term mortality after ES is high, and one-third of patients will die within 15 days. Whether radiofrequency ablation of arrhythmias improves outcomes would require further studies.


Subject(s)
Heart Failure/surgery , Heart-Assist Devices/adverse effects , Tachycardia, Ventricular/etiology , Ventricular Fibrillation/etiology , Ventricular Fibrillation/mortality , Adult , Age Factors , Aged , Cohort Studies , Female , Heart Failure/diagnostic imaging , Heart Failure/mortality , Humans , Incidence , Kaplan-Meier Estimate , Male , Markov Chains , Middle Aged , Postoperative Complications/epidemiology , Postoperative Complications/physiopathology , Predictive Value of Tests , Proportional Hazards Models , Retrospective Studies , Risk Assessment , Sex Factors , Survival Rate , Tachycardia, Ventricular/mortality , Tachycardia, Ventricular/physiopathology , Ventricular Fibrillation/physiopathology
14.
Am Heart J ; 214: 69-76, 2019 08.
Article in English | MEDLINE | ID: mdl-31174053

ABSTRACT

BACKGROUND: Left ventricular assist device (LVAD)-associated infections may be life-threatening and impact patients' outcome. We aimed to identify the characteristics, risk factors, and prognosis of LVAD-associated infections. METHODS: Patients included in the ASSIST-ICD study (19 centers) were enrolled. The main outcome was the occurrence of LVAD-associated infection (driveline infection, pocket infection, or pump/cannula infection) during follow-up. RESULTS: Of the 652 patients enrolled, 201 (30.1%) presented a total of 248 LVAD infections diagnosed 6.5 months after implantation, including 171 (26.2%), 51 (7.8%), and 26 (4.0%) percutaneous driveline infection, pocket infection, or pump/cannula infection, respectively. Patients with infections were aged 58.7 years, and most received HeartMate II (82.1%) or HeartWare (13.4%). Most patients (62%) had implantable cardioverter-defibrillators (ICDs) before LVAD, and 104 (16.0%) had ICD implantation, extraction, or replacement after the LVAD surgery. Main pathogens found among the 248 infections were Staphylococcus aureus (n = 113' 45.4%), Enterobacteriaceae (n = 61; 24.6%), Pseudomonas aeruginosa (n = 34; 13.7%), coagulase-negative staphylococci (n = 13; 5.2%), and Candida species (n = 13; 5.2%). In multivariable analysis, HeartMate II (subhazard ratio, 1.56; 95% CI, 1.03 to 2.36; P = .031) and ICD-related procedures post-LVAD (subhazard ratio, 1.43; 95% CI, 1.03-1.98; P = .031) were significantly associated with LVAD infections. Infections had no detrimental impact on survival. CONCLUSIONS: Left ventricular assist device-associated infections affect one-third of LVAD recipients, mostly related to skin pathogens and gram-negative bacilli, with increased risk with HeartMate II as compared with HeartWare, and in patients who required ICD-related procedures post-LVAD. This is a plea to better select patients needing ICD implantation/replacement after LVAD implantation.


Subject(s)
Catheter-Related Infections/etiology , Heart-Assist Devices/adverse effects , Prosthesis-Related Infections/etiology , Catheter-Related Infections/epidemiology , Catheter-Related Infections/microbiology , Catheter-Related Infections/mortality , Defibrillators, Implantable/statistics & numerical data , Device Removal/statistics & numerical data , Female , France/epidemiology , Heart Ventricles , Heart-Assist Devices/statistics & numerical data , Humans , Male , Middle Aged , Multivariate Analysis , Prognosis , Prosthesis-Related Infections/epidemiology , Prosthesis-Related Infections/microbiology , Prosthesis-Related Infections/mortality , Retrospective Studies , Risk Factors
15.
Expert Rev Cardiovasc Ther ; 16(11): 775-794, 2018 Nov.
Article in English | MEDLINE | ID: mdl-30282492

ABSTRACT

INTRODUCTION: Heart failure (HF) has become a global pandemic. Despite recent developments in both medical and device treatments, HF incidences continues to increase. The current definition of HF restricts itself to stages at which clinical symptoms are apparent. In advanced heart failure (AdHF), it is universally accepted that all patients are refractory to traditional therapies. As the number of HF patients increase, so does the need for additional treatments, with an increased proportion of patients requiring advanced therapies. Areas covered: This review discusses extensive evidence for the effect of medical treatment on HF, although the data on the effect on AdHF is scare. Authors review the relevant literature for treating AdHF patients. Furthermore, mechanical circulatory devices (MCD) have emerged as an alternative to heart transplantation and have been shown to enhance quality of life and reduce mortality therefore authors also review the current literature on the different MCD and technologies. Expert commentary: More patients will need advanced therapies, as the access to heart transplantation is limited by the number of available donors. AdHF patients should be identified timely since the window of opportunities for advanced therapy is narrow as their morbidity is progressive and survival is often short.


Subject(s)
Heart Failure/therapy , Heart Transplantation/methods , Heart-Assist Devices , Humans , Quality of Life
16.
JACC Clin Electrophysiol ; 4(9): 1166-1175, 2018 09.
Article in English | MEDLINE | ID: mdl-30236390

ABSTRACT

OBJECTIVES: This study aimed to evaluate the incidence, clinical impact, and predictors of late ventricular arrhythmias (VAs) in left ventricular assist device (LVAD) recipients aiming to clarify implantable cardioverter-defibrillator (ICD) indications. BACKGROUND: The arrhythmic risk and need for ICD in patients implanted with an LVAD are not very well known. METHODS: This observational study was conducted in 19 centers between 2006 and 2016. Late VAs were defined as sustained ventricular tachycardia or fibrillation occurring >30 days post-LVAD implantation, without acute reversible cause and requiring appropriate ICD therapy, external electrical shock, or medical therapy. RESULTS: Among 659 LVAD recipients, 494 (median 58.9 years of age; mean left ventricular ejection fraction 20.7 ± 7.4%; 73.1% HeartMate II, 18.6% HeartWare, 8.3% Jarvik 2000) were discharged alive from hospital and included in the final analysis. Late VAs occurred in 133 (26.9%) patients. Multivariable analysis identified 6 independent predictors of late VAs: VAs before LVAD implantation, atrial fibrillation before LVAD implantation, idiopathic etiology of the cardiomyopathy, heart failure duration >12 months, early VAs (<30 days post-LVAD), and no angiotensin-converting enzyme inhibitors during follow-up. The "VT-LVAD score" was created, identifying 4 risk groups: low (score 0 to 1), intermediate (score 2 to 4), high (score 5 to 6), and very high (score 7 to 10). The rates of VAs at 1 year were 0.0%, 8.0%, 31.0% and 55.0%, respectively. CONCLUSIONS: Late VAs are common after LVAD implantation. The VT-LVAD score may help to identify patients at risk of late VAs and guide ICD indications in previously nonimplanted patients. (Determination of Risk Factors of Ventricular Arrhythmias [VAs] after implantation of continuous flow left ventricular assist device with continuous flow left ventricular assist device [CF-LVAD] [ASSIST-ICD]; NCT02873169).


Subject(s)
Arrhythmias, Cardiac , Defibrillators, Implantable , Heart-Assist Devices/adverse effects , Aged , Arrhythmias, Cardiac/epidemiology , Arrhythmias, Cardiac/mortality , Arrhythmias, Cardiac/surgery , Female , Humans , Male , Middle Aged , Retrospective Studies , Risk Factors
17.
ASAIO J ; 64(4): 502-507, 2018.
Article in English | MEDLINE | ID: mdl-28953197

ABSTRACT

Peripheral veno-arterial extracorporeal membrane oxygenation (VA ECMO) exposes the patient to a pulmonary blood flow bypass and a left ventricle afterload increase. Impella, a catheter-mounted microaxial rotary pump, has been proposed for left ventricle (LV) unloading in combination with VA ECMO. In order to assess the effect of Impella on pulmonary flow and LV preload, we checked Doppler pulmonary artery velocity-time integral (pVTI) and LV diastolic diameter (LVED) by transesophageal echocardiography and end-tidal carbon dioxide (EtCO2) during a step-by-step increase in Impella flow (Impella ramp test). From 134 patients on VA ECMO retrieved from our database, 27 (20%) have benefited secondary Impella implantation, out of which 11 patients had available EtCO2, pVTI, and LVED measurements at various levels of Impella speeds. We observed a proportional increases in pVTI and EtCO2 and decrease in LVED (p ≤ 0.001) during Impella flow increase. There was a significant correlation between EtCO2 and pVTI (Pearson correlation coefficient 0.64; p = 0.006). The study shows that Impella improves pulmonary flow, an effect that can be easily measured by EtCO2 monitoring, and ensures LV discharge, allowing adapting Impella flow adequately to patient's individual needs.


Subject(s)
Carbon Dioxide/blood , Extracorporeal Membrane Oxygenation , Heart-Assist Devices , Pulmonary Artery/physiopathology , Adult , Female , Heart Failure/therapy , Humans , Male , Middle Aged , Pulmonary Circulation
18.
ASAIO J ; 64(6): 708-714, 2018.
Article in English | MEDLINE | ID: mdl-29240628

ABSTRACT

Temporary mechanical circulatory support (TCS) is recommended for patients with profound cardiogenic shock (CS). Extracorporeal membrane oxygenation (ECMO) and Impella are possible TCS devices, but the device choice and the implantation timing are not definitely established, specifically during acute myocardial infarction. We have analyzed the respective use of ECMO or Impella (2.5, CP, or 5.0) for CS following acute myocardial infarction, from a cohort of patients who underwent TCS within 72 hours after admission for emergency percutaneous coronary intervention (PCI) from January 2009 to April 2015. Among 88 TCS-treated patients, 42 had early TCS: 23 ECMO and 19 Impella. Cardiac management, including PCI, was similar between the two groups, but ECMO patients were sicker than Impella patients (higher blood lactate level at ICU admission, higher vasoactive-inotroic and ENCOURAGE scores before TCS implantation, p ≤ 0.02). Three patients (7%) have had TCS implantation before admission, but TCS was implanted mostly in cathlab (43%, 1 during PCI, 13 just after PCI) or soon after ICU admission (50%, n = 21). Modification of the initial TCS choice was required in 10 cases (24%) for assistance upgrading in case of Impella (n = 4) or for left ventricle unloading in case of ECMO (n = 6). Extracorporeal membrane oxygenation is the technique of choice in case of profound CS, whereas Impella devices seem more appropriate for less severe hemodynamic compromise. Interestingly, the combination of both techniques may help to overcome the limits inherent to each device.


Subject(s)
Heart-Assist Devices , Myocardial Infarction/therapy , Shock, Cardiogenic/therapy , Extracorporeal Membrane Oxygenation/methods , Female , Hemodynamics , Humans , Male , Middle Aged , Myocardial Infarction/complications , Percutaneous Coronary Intervention/methods , Retrospective Studies , Shock, Cardiogenic/etiology
19.
Crit Care ; 19: 363, 2015 Oct 09.
Article in English | MEDLINE | ID: mdl-26453047

ABSTRACT

INTRODUCTION: Cardiogenic shock refractory to standard therapy with inotropes and/or intra-aortic balloon pump is accompanied with an unacceptable high mortality. Percutaneous left ventricular assist devices may provide a survival benefit for these very sick patients. In this study, we describe our experience with the Impella 5.0 device used in the setting of refractory cardiogenic shock. METHODS: In this observational, retrospective, single-center study we included all the consecutive patients supported with Impella 5.0, between May 2008 and December 2013, for refractory cardiogenic shock. Patients' baseline and procedural characteristics, hemodynamics and outcome to the first 48 h of support, to ICU discharge and day-28 visit were collected. RESULTS: A total of 40 patients were included in the study. Median age was 57 years and 87.5 % were male. Cardiogenic shock resulted from acute myocardial infarction in 17 patients (43 %), dilated cardiomyopathy in 12 (30 %) and postcardiotomy cardiac failure in 7 (18 %). In 15 patients Impella 5.0 was added to an ECMO to unload the left ventricle. The median SOFA score for the entire cohort prior to circulatory support was 12 [10-14] and the duration of Impella support was 7 [5-10] days. We observed a significant decrease of the inotrope score (10 [1-17] vs. 1 [0-9]; p = 0.04) and the lactate values (3.8 [1.7-5.9] mmol/L vs. 2.5 [1.5-3.4] mmol/L; p = 0.01) after 6 h of support with Impella 5.0. Furthermore, at Impella removal the patients' left ventricular ejection fraction improved significantly (p < 0.001) when compared to baseline. Cardiac recovery, bridge to left ventricular assist device or heart transplantation was possible in 28 patients (70 %). Twenty-six patients (65 %) survived at day 28. A multivariate analysis showed a higher risk of mortality for patients with acute myocardial infarction (hazard ratio = 4.1 (1.2-14.2); p = 0.02). CONCLUSIONS: Impella 5.0 allowed fast weaning of inotropes and might facilitate myocardial recovery. Despite high severity scores at admission, day-28 mortality rate was better than predicated.


Subject(s)
Heart-Assist Devices , Shock, Cardiogenic/surgery , Echocardiography , Female , Heart-Assist Devices/adverse effects , Humans , Male , Middle Aged , Retrospective Studies , Shock, Cardiogenic/mortality , Stroke Volume , Treatment Outcome
20.
Soins ; (793): 44-6, 2015 Mar.
Article in French | MEDLINE | ID: mdl-26040141

ABSTRACT

A coronary artery bypass involves taking blood vessels from another part of the patient's body to bypass one or several major coronary stenoses. Coronary artery bypass using cardiopulmonary bypass and off-pump coronary artery bypass are the two methods used to revascularise the heart after a myocardial infarction.


Subject(s)
Coronary Artery Bypass/methods , Cardiopulmonary Bypass , Coronary Artery Bypass, Off-Pump , Humans , Myocardial Infarction/therapy