Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 43
Filter
1.
Vaccines (Basel) ; 10(11)2022 Nov 19.
Article in English | MEDLINE | ID: mdl-36423058

ABSTRACT

Pneumonia accounts for over 20% of deaths worldwide in children aged 1 to 5 years, disproportionately affecting lower- and middle-income countries. Effective, highly multivalent pneumococcal vaccines are available to decrease disease burden, with numerous new vaccines currently under development to serve a variety of worldwide markets. However, pneumococcal conjugate vaccines are among the hardest biologics to manufacture and characterize due to their complexity and heterogeneity. Current characterization methods are often inherently singleplex, requiring separate tests for each serotype present. In addition, identity and quantity are often determined with separate methods. We developed the VaxArray pneumococcal assay for applications in identity, quantity, and stability testing of pneumococcal polysaccharide and pneumococcal conjugate vaccines. The VaxArray pneumococcal assay has a time to result of less than 30 min and is an off-the-shelf multiplexed, microarray-based immunoassay kit that can identify and simultaneously quantify 23 pneumococcal polysaccharide serotypes common to many on-market and in-development vaccines. Here, we highlight the potential of the assay for identity testing by showing high reactivity and serotype specificity to a wide variety of native polysaccharides, CRM197-conjugated polysaccharides, and drug product. The assay also has vaccine-relevant lower limits of quantification in the low-to-mid ng/mL range and can be used for accurate quantification even in adjuvanted vaccines. Excellent correlation to the anthrone assay is demonstrated, with VaxArray resulting in significantly improved precision over this antiquated chemical method.

2.
Vaccines (Basel) ; 10(10)2022 Oct 12.
Article in English | MEDLINE | ID: mdl-36298569

ABSTRACT

The COVID-19 pandemic highlighted mRNA as a promising platform for vaccines and therapeutics. Many of the analytical tools used to characterize the critical quality attributes of mRNA are inherently singleplex and are not necessarily optimal from a labor and cost perspective. Here, we demonstrate the feasibility of a multiplexed platform (VaxArray) for efficient identity verification and concentration determination for both monovalent and multivalent mRNA formulations. A model system comprising mRNA constructs for influenza hemagglutinin and neuraminidase was used to characterize the analytical performance metrics for a VaxArray mRNA assay. The assay presented herein had a time to result of less than 2 h, required no PCR-based amplification nor extraction of mRNA from lipid nanoparticles, and exhibited high construct specificity that enabled application to the bivalent mixture. The sensitivity for influenza hemagglutinin and neuraminidase mRNA was sub-µg/mL, which is vaccine-relevant, and the average accuracy (%recovery of a check standard) and precision were 104 ± 2% and 9 ± 2%, respectively.

3.
J Immunol Methods ; 504: 113259, 2022 05.
Article in English | MEDLINE | ID: mdl-35314144

ABSTRACT

Next generation poliovirus vaccines are critical to reaching global poliovirus eradication goals. Recent efforts have focused on creating inactivated vaccines using attenuated Sabin strains that maintain patient safety benefits and immunogenicity of conventional inactivated vaccines while increasing manufacturing safety and lowering production costs, and on developing novel oral vaccines using modified Sabin strains that provide critical mucosal immunity but are further attenuated to minimize risk of reversion to neurovirulence. In addition, there is a push to improve the analytical tools for poliovirus vaccine characterization. Conventional and Sabin inactivated poliovirus vaccines typically rely on standard plate-based ELISA as in vitro D-antigen potency assays in combination with WHO international standards as calibrants. While widely utilized, the current D-antigen ELISA assays have a long time to result (up to 72 h), can suffer from lab-to-lab inconsistency due to non-standardized protocols and reagents, and are inherently singleplex. For D-antigen quantitation, we have developed the VaxArray Polio Assay Kit, a multiplexed, microarray-based immunoassay that uses poliovirus-specific human monoclonal antibodies currently under consideration as standardized reagents for characterizing inactivated Sabin and Salk vaccines. The VaxArray assay can simultaneously quantify all 3 poliovirus serotypes with a time to result of less than 3 h. Here we demonstrate that the assay has limits of quantification suitable for both bioprocess samples and final vaccines, excellent reproducibility and precision, and improved accuracy over an analogous plate-based ELISA. The assay is suitable for adjuvanted combination vaccines, as common vaccine additives and crude matrices do not interfere with quantification, and is intended as a high throughput, standardized quantitation tool to aid inactivated poliovirus vaccine manufacturers in streamlining vaccine development and manufacturing, aiding the global polio eradication effort.


Subject(s)
Poliomyelitis , Poliovirus , Antibodies, Viral , Antigens, Viral , Enzyme-Linked Immunosorbent Assay , Humans , Poliomyelitis/diagnosis , Poliomyelitis/prevention & control , Poliovirus Vaccine, Inactivated , Poliovirus Vaccine, Oral , Reproducibility of Results , Vaccines, Inactivated
4.
Vaccine X ; 9: 100113, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34622199

ABSTRACT

Measles-containing vaccines (MCV), specifically vaccines against measles and rubella (MR), are extremely effective and critical for the eradication of measles and rubella diseases. In developed countries, vaccination rates are high and vaccines are readily available, but continued high prevalence of both diseases in developing countries and surges in measles deaths in recent years have highlighted the need to expand vaccination efforts. To meet demand for additional vaccines at a globally affordable price, it is highly desirable to streamline vaccine production thereby reducing cost and speeding up time to delivery. MR vaccine characterization currently relies on the 50% cell culture infectious dose (CCID50) assay, an endpoint assay with low reproducibility that requires 10-14 days to complete. For streamlining bioprocess analysis and improving measurement precision relative to CCID50, we developed the VaxArray Measles and Rubella assay kit, which is based on a multiplexed microarray immunoassay with a 5-hour time to result. Here we demonstrate vaccine-relevant sensitivity ranging from 345 to 800 IFU/mL up to 100,000 IFU/mL (infectious units per mL) and specificity that allows simultaneous analysis in bivalent vaccine samples. The assay is sensitive to antigen stability and has minimal interference from common vaccine additives. The assay exhibits high reproducibility and repeatability, with 15% CV, much lower than the typical 0.3 log10 error (∼65%) observed for the CCID50 assay. The intact protein concentration measured by VaxArray is reasonably correlated to, but not equivalent to, CCID50 infectivity measurements for harvest samples. However, the measured protein concentration exhibits equivalency to CCID50 for more purified samples, including concentrated virus pools and monovalent bulks, making the assay a useful new tool for same-day analysis of vaccine samples for bioprocess development, optimization, and monitoring.

5.
J Immunol Methods ; 497: 113104, 2021 10.
Article in English | MEDLINE | ID: mdl-34303688

ABSTRACT

Mitigation of the COVID-19 pandemic requires an understanding of the antibody response to SARS-CoV-2. However, throughout the development of SARS-CoV-2 IgG antibody assays during the past year, cross-reactivity to other coronaviruses remained a question. To address these issues, we evaluated IgG in COVID-19 convalescent plasma samples for reactivity against three SARS-CoV-2 antigens including full-length spike, receptor binding domain, and the proximal extracellular fusion domain, and spike antigens from other coronaviruses (SARS-CoV, MERS-CoV, hCoV-HKU1, hCoV-OC43, hCoV-229E and hCoV-NL63) using the VaxArray Coronavirus SeroAssay which is a multiplexed antigen assay developed by InDevR Inc. These results were compared to two commercial SARS-CoV-2 IgG ELISAs targeting either the SARS-CoV-2 nucleocapsid or spike antigens and a live virus focus reduction neutralizing antibody test (FRNT). The VaxArray platform showed high specificity for detection of SARS-CoV-2 IgG, evident from lack of reactivity to SARS-CoV-2 antigens despite significant reactivity to endemic coronavirus antigens in pre-pandemic samples. SARS-CoV-2 IgG positive samples reacted weakly to SARS-CoV spike but not to MERS-CoV. While the VaxArray platform had overall comparable results to the spike and nucleocapsid IgG ELISAs, results were more similar to the spike antigen ELISA and the platform displayed a higher sensitivity and specificity than both ELISAs. Samples with FRNT titers below 1/23 reported negative on VaxArray, while positive samples on VaxArray had significantly higher neutralizing antibody titers. These results suggest that the VaxArray Coronavirus SeroAssay performs with high sensitivity and specificity for the detection of SARS-CoV-2 IgG, and positive results on the platform indicate SARS-CoV-2 neutralizing activity.


Subject(s)
Antibodies, Viral/immunology , Antigens, Viral/immunology , COVID-19/diagnosis , Immunoassay/methods , Immunoglobulin G/immunology , SARS-CoV-2/immunology , Antibodies, Neutralizing/blood , Antibodies, Neutralizing/immunology , Antibodies, Viral/blood , COVID-19/epidemiology , COVID-19/virology , Cross Reactions/immunology , Enzyme-Linked Immunosorbent Assay/methods , Humans , Immunoglobulin G/blood , Pandemics/prevention & control , Reproducibility of Results , SARS-CoV-2/physiology , Sensitivity and Specificity , Spike Glycoprotein, Coronavirus/immunology
6.
J Virol Methods ; 291: 114111, 2021 05.
Article in English | MEDLINE | ID: mdl-33640374

ABSTRACT

Rapid, sensitive, and precise multiplexed assays for serological analysis during candidate COVID-19 vaccine development would streamline clinical trials. The VaxArray Coronavirus (CoV) SeroAssay quantifies IgG antibody binding to 9 pandemic, potentially pandemic, and endemic human CoV spike antigens in 2 h with automated results analysis. IgG antibodies in serum bind to the CoV spike protein capture antigens printed in a microarray format and are labeled with a fluorescent anti-species IgG secondary label. The assay demonstrated excellent lower limits of quantification ranging from 0.3 to 2.0 ng/mL and linear dynamic ranges of 76 to 911-fold. Average precision of 11 % CV and accuracy (% recovery) of 92.5 % over all capture antigens were achieved over 216 replicates representing 3 days and 3 microarray lots. Clinical performance on 263 human serum samples (132 SARS-CoV-2 negatives and 131 positives based on donor-matched RT-PCR and/or date of collection) produced 98.5 % PPA and 100 % NPA.


Subject(s)
Antibodies, Viral/blood , Coronavirus Infections/diagnosis , Coronavirus/isolation & purification , Microarray Analysis/methods , Serologic Tests/methods , Antigens, Viral/immunology , COVID-19/diagnosis , COVID-19/immunology , COVID-19 Nucleic Acid Testing , COVID-19 Testing/methods , Coronavirus/immunology , Coronavirus Infections/immunology , Humans , Immunoassay/methods , Immunoglobulin G/blood , Reproducibility of Results , SARS-CoV-2/isolation & purification , Sensitivity and Specificity , Spike Glycoprotein, Coronavirus/immunology
7.
Influenza Other Respir Viruses ; 14(1): 55-60, 2020 01.
Article in English | MEDLINE | ID: mdl-31608599

ABSTRACT

BACKGROUND: Global influenza surveillance in humans and animals is a critical component of pandemic preparedness. The FluChip-8G Insight assay was developed to subtype both seasonal and potentially pandemic influenza viruses in a single assay with a same day result. FluChip-8G Insight uses whole gene segment RT-PCR-based amplification to provide robustness against genetic drift and subsequent microarray detection with artificial neural network-based data interpretation. OBJECTIVES: The objective of this study was to verify and validate the performance of the FluChip-8G Insight assay for the detection and positive identification of human and animal origin non-seasonal influenza A specimens. METHODS: We evaluated the ability of the FluChip-8G Insight technology to type and HA and NA subtype a sample set consisting of 297 results from 180 unique non-seasonal influenza A strains (49 unique subtypes). RESULTS: FluChip-8G Insight demonstrated a positive percent agreement ≥93% for 5 targeted HA and 5 targeted NA subtypes except for H9 (88%), and negative percent agreement exceeding 95% for all targeted subtypes. CONCLUSIONS: The FluChip-8G Insight neural network-based algorithm used for virus identification performed well over a data set of 297 naïve sample results, and can be easily updated to improve performance on emerging strains without changing the underlying assay chemistry.


Subject(s)
Hemagglutinin Glycoproteins, Influenza Virus/genetics , Influenza A virus/isolation & purification , Influenza, Human/virology , Neuraminidase/genetics , Reverse Transcriptase Polymerase Chain Reaction/methods , Viral Proteins/genetics , DNA Primers/genetics , Humans , Influenza A virus/classification , Influenza A virus/genetics , Influenza, Human/diagnosis , Influenza, Human/epidemiology , Pandemics , United States/epidemiology
8.
J Clin Virol ; 118: 20-27, 2019 09.
Article in English | MEDLINE | ID: mdl-31382226

ABSTRACT

BACKGROUND: The FluChip-8G Influenza A+B Assay is a multiplexed influenza RT-PCR and microarray-based assay with same day turnaround time, developed to subtype seasonal A viruses (H1N1pdm2009 and H3N2), distinguish B viruses as Yamagata or Victoria lineage, and is the only FDA cleared assay capable of positive identification of a wide variety of A subtypes as "non-seasonal" A viruses from human nasal specimens. OBJECTIVE: To evaluate clinical performance of the FluChip-8G Influenza A+B Assay for detection of seasonal influenza viruses in nasal and nasopharyngeal swab specimens, and to evaluate performance for detection of non-seasonal influenza viruses using contrived samples. STUDY DESIGN: For seasonal viruses, a multisite study of the FluChip-8G Influenza A+B Assay using prospectively and retrospectively collected nasal and nasopharyngeal swabs was performed using the FDA-cleared CDC Human Flu Dx Panel as the comparator assay. For non-seasonal viruses, testing was performed at a single site using contrived samples from 100 unique non-seasonal strains representing 41 subtypes. RESULTS: Sensitivity (95% CI) and specificity (95% CI) for each target group, respectively, from results of 1689 clinical specimens were: seasonal H1N1pdm2009: 96.4% (87.9-99.0), 99.3% (98.8-99.6), seasonal H3N2: 91.8% (87.7-94.7), 99.7% (99.2-99.9), Influenza B Victoria: 100% (94.0-100.0), 99.9% (99.6-100.0), and Influenza B Yamagata: 95.6% (89.2-98.3), 99.9% (99.6-100.0). The sensitivity and specificity from contrived influenza A non-seasonal viruses was determined to be 99.0% (94.6-99.8) and 100% (96.7-100.0). CONCLUSION: The FluChip-8G Influenza A+B Assay has robust sensitivity and specificity for detecting and identifying all target virus groups, including non-seasonal influenza A, with same day results.


Subject(s)
Genotyping Techniques/methods , Influenza A virus/isolation & purification , Influenza B virus/isolation & purification , Influenza, Human/diagnosis , Microarray Analysis/methods , Molecular Diagnostic Techniques/methods , Reverse Transcriptase Polymerase Chain Reaction/methods , Adolescent , Adult , Aged , Aged, 80 and over , Child , Child, Preschool , Female , Humans , Infant , Infant, Newborn , Influenza A virus/classification , Influenza A virus/genetics , Influenza B virus/classification , Influenza B virus/genetics , Male , Middle Aged , Nasal Cavity/virology , Nasopharynx/virology , Prospective Studies , Retrospective Studies , Sensitivity and Specificity , Young Adult
9.
J Virol Methods ; 273: 113686, 2019 11.
Article in English | MEDLINE | ID: mdl-31271790

ABSTRACT

BACKGROUND: Influenza causes a significant annual disease burden, with characterization of the infecting virus important in clinical and public health settings. Rapid immunoassays are fast but insensitive, whereas real-time RT-PCR is sensitive but susceptible to genetic mutations and often requires multiple serial assays. The FluChip-8G Influenza A+B Assay provides type and subtype/lineage identification of influenza A and B, including non-seasonal A viruses, in a single microarray-based assay with same day turnaround time. OBJECTIVE: To evaluate key analytical performance characteristics of the FluChip-8G Influenza A+B Assay. STUDY DESIGN: Analytical sensitivity, cross-reactivity, and multi-site reproducibility were evaluated. RESULTS: The limit of detection (LOD) for the FluChip-8G influenza A+B Assay ranged from 5.8 × 102-1.5 × 105 genome copies/mL, with most samples ∼2 × 103 genome copies/mL (∼160 genome copies/reaction). Fifty two (52) additional strains were correctly identified near the LOD, demonstrating robust reactivity. Two variant viruses (H1N1v and H3N2v) resulted in dual identification as both "non-seasonal influenza A" and A/H1N1pdm09. No reproducible cross-reactivity was observed for the 34 organisms tested, however, challenges with internal control inhibition due to crude growth matrix were observed. Lastly, samples tested near the LOD showed high reproducibility (97.0% (95% CI 94.7-98.7)) regardless of operator, site, reagent lot, or testing day. CONCLUSION: The FluChip-8G Influenza A+B Assay is an effective new method for detecting and identifying both seasonal and non-seasonal influenza viruses, as revealed by good sensitivity and robust reactivity to 52 unique strains of influenza virus. In addition, the lack of cross-reactivity to non-influenza pathogens and high lab-to-lab reproducibility highlight the analytical performance of the assay as an alternative to real-time RT-PCR and sequencing-based assays. Clinical validation of the technology in a multi-site clinical study is the subject of a separate investigation.


Subject(s)
Influenza A virus/genetics , Influenza B virus/genetics , Influenza, Human/classification , Influenza, Human/diagnosis , Microarray Analysis/standards , Cross Reactions , Genome, Viral , Humans , Influenza A virus/classification , Influenza, Human/virology , Limit of Detection , Microarray Analysis/methods , Nose/virology , Reproducibility of Results , Sensitivity and Specificity
10.
NPJ Vaccines ; 4: 3, 2019.
Article in English | MEDLINE | ID: mdl-30675394

ABSTRACT

Neuraminidase (NA) immunity leads to decreased viral shedding and reduced severity of influenza disease; however, NA content in influenza vaccines is currently not regulated, resulting in inconsistent quality and quantity of NA that can vary from manufacturer to manufacturer, from year to year, and from lot to lot. To address this problem, we have developed an assay for NA quantification that could be used by the industry to move toward developing influenza vaccines that induce a predictable immune response to NA. The VaxArray Influenza Seasonal NA Potency Assay (VXI-sNA) is a multiplexed sandwich immunoassay that relies on six subtype-specific monoclonal antibodies printed in microarray format and a suite of fluor-conjugated "label" antibodies. The performance of the assay as applied to a wide range of influenza vaccines is described herein. The assay demonstrated high NA subtype specificity and high sensitivity, with quantification limits ranging from 1 to 60 ng/mL and linear dynamic ranges of 24-500-fold. When compared to an enzymatic activity assay for samples exposed to thermal degradation conditions, the assay was able to track changes in protein stability over time and exhibited good correlation with enzyme activity. The assay also demonstrated excellent analytical precision with relative error ranging from 6 to 12% over day-to-day, user-to-user, and lot-to-lot variation. The high sensitivity and reproducibility of the assay enabled robust detection and quantification of NA in crude in-process samples and low-dose, adjuvanted vaccines with an accuracy of 100 ± 10%.

11.
NPJ Vaccines ; 3: 43, 2018.
Article in English | MEDLINE | ID: mdl-30323954

ABSTRACT

The VaxArray Influenza Pandemic HA (VXI-pHA) potency assay is a multiplexed sandwich immunoassay that consists of nine broadly reactive yet subtype-specific monoclonal capture antibodies printed in microarray format and a suite of fluor-labeled secondary antibodies that were selected to probe conserved HA epitopes. VXI-pHA was designed to optimize the probability that the ready-to-use assay would work for the most concerning, emergent influenza A strains, eliminating the need for the time-consuming process of reference reagents production. The performance of this new potency test was evaluated using a panel of 48 potentially pandemic strains of influenza viruses and vaccines spanning 16 years of antigenic drift, including the most recent pre-pandemic vaccine being developed against the "5th wave" A/H7N9 virus. The VXI-pHA assay demonstrated coverage of 93%, 92%, and 100% for H5, H7, and H9 antigens, respectively. The assay demonstrated high sensitivity with linear dynamic ranges of more than 150-fold and quantification limits ranging from 1 to 5 ng/mL. For three production lots of H7N9 monobulk drug substance, the assay exhibited excellent accuracy (100 ± 6%) and analytical precision (CV 6 ± 2%). The high assay sensitivity enabled robust detection and quantification of hemagglutinin in crude in-process samples and low-dose, adjuvanted vaccines with an accuracy of 100 ± 10%.

12.
Vaccine ; 36(21): 2937-2945, 2018 05 17.
Article in English | MEDLINE | ID: mdl-29699789

ABSTRACT

Practical methods to measure the potency of influenza vaccines are needed as alternatives for the standard single radial immunodiffusion (SRID) assay. VaxArray assays for influenza hemagglutinin (HA) and neuraminidase (NA) have been developed to address this need. In this report, we evaluate the use of these assays to assess the potency of HA and NA of an A/H3N2 subunit vaccine by determining the correlation between the amounts measured by VaxArray and the immunogenicity in mice. The antibody response after one and two doses of five formulations of the vaccine ranging from 5 µg/mL to 80 µg/mL of HA, was measured by hemagglutination inhibition (HAI) and neuraminidase inhibition (NAI) assays. For hemagglutinin, vaccine potency determined by VaxArray was equivalent to potency measured SRID and these amounts were predictive of immunogenicity, with excellent correlation between potency measured by VaxArray and the HAI geometric mean titers (GMT). Likewise, the amount of NA measured by VaxArray was predictive of the NAI GMT. The VaxArray NA assay reported non-detectable levels of intact NA for a sample that had been heat degraded at 56 °C for 20 h, demonstrating that the assay measures the native, active form of NA. Similarly, the HA potency measured by VaxArray in this heat-treated sample was very low when a monoclonal antibody was used to detect the amount of antigen bound. Importantly, the force degraded sample induced low HAI titers and the NAI titers were not measurable, supporting the conclusion that the VaxArray HA and NA assays measure the immunogenic forms of these A/H3N2 antigens. This study indicates that VaxArray assays can be used to assess the potency of HA and NA components in influenza vaccines as a proxy for immunogenicity.


Subject(s)
Hemagglutinin Glycoproteins, Influenza Virus/immunology , Influenza A Virus, H3N2 Subtype/immunology , Influenza Vaccines/immunology , Neuraminidase/immunology , Technology, Pharmaceutical/methods , Vaccine Potency , Viral Proteins/immunology , Animals , Antibodies, Viral/blood , Female , Hemagglutination Inhibition Tests , Influenza Vaccines/administration & dosage , Mice, Inbred BALB C , Neutralization Tests , Vaccines, Subunit/administration & dosage , Vaccines, Subunit/immunology
13.
PLoS One ; 12(6): e0179939, 2017.
Article in English | MEDLINE | ID: mdl-28662088

ABSTRACT

The hemagglutination inhibition assay (HAI) is widely used to evaluate vaccine-induced antibody responses as well as to antigenically characterize influenza viruses. The results of an HAI assay are based on an endpoint titration where the titers are generally manually interpreted and recorded by a well-trained expert. For serological applications, the lack of standardization in endpoint interpretation and interference from non-specific inhibitors in clinical samples can translate into a high degree of variability in the results. For example, tilting HAI plates at 45-60 degrees to look for a "tear drop pattern" with avian red blood cells is a common practice by many, but not all, research laboratories. In this work, we tested the hypothesis that an automated image analysis algorithm can be used to achieve an accurate and non-subjective interpretation of HAI assays-specifically without the need to tilt plates. In a side-by-side comparison study performed during FDA's biannual serological screening process for influenza viruses, titer calls for more than 2200 serum samples were made by the Cypher One automated hemagglutination analyzer without tilting and by an expert human with tilting. The comparison yielded 95.6% agreement between the expert reader and automated interpretation method (within ± 1 dilution) for the complete dataset. Performance was also evaluated relative to the type of red blood cell (turkey and guinea pig) and influenza strain (12 different viruses). For the subset that utilized guinea pig red blood cells (~44% of the samples), for which no plate tilting was required, the agreement with an expert reader was 97.2%. For the subset that utilized turkey red blood cells (~56% of the samples), for which plate tilting was necessary by the expert reader, the agreement was 94.3%. Overall these results support the postulate that algorithm-based interpretation of a digital record with no plate tilting could replace manual reading for greater consistency in HAI assays.


Subject(s)
Automation , Hemagglutination Inhibition Tests/methods , Animals , Guinea Pigs , Humans , Turkeys
14.
Vaccine ; 35(15): 1918-1925, 2017 04 04.
Article in English | MEDLINE | ID: mdl-28262335

ABSTRACT

Vaccine manufacturers require more rapid and accurate tools to characterize the potency and stability of their products. Currently, the gold standard for influenza vaccine potency is the single radial immunodiffusion (SRD) assay, which has inherent disadvantages. The primary objective of this study was to investigate the ability of the VaxArray Influenza (VXI) seasonal hemagglutinin (sHA) potency assay to accurately quantify potency and stability in finished vaccines as well as to quantify hemagglutinin protein (HA) within crude in-process samples. Monobulk intermediates and mono- and multivalent vaccines were tested using VXI. Quantification of HA in crude samples was evaluated by spiking known concentrations of HA into allantoic fluid. VXI generated SRD equivalent potency measurements with high accuracy (within ±10%) and precision (CV 10±4%) for antigen components of monobulk intermediates and multivalent split vaccines. For these vaccines and vaccine intermediates, the VXI linear dynamic range was ∼0.01-0.6µg/mL, which is 12× greater than the linear range of SRD. The measured sample limit of detection (LOD) for VXI varied from 0.005 to 0.01µg/mL for the different subtypes, which in general is ≥600× lower than the LOD for SRD. VXI was able to quantify HA in crude samples where HA only accounts for 0.02% of the total protein content. Stability indication was investigated by tracking measured potency as a function of time at elevated temperature by both SRD and VXI. After 20 h at 56°C, the ratio of VXI to SRD measured potency in a quadrivalent vaccine was 76%, 125%, 60%, and 98% for H1/California, H3/Switzerland, B/Phuket and B/Brisbane, respectively. Based on the study results, it is concluded that VXI is a rapid, multiplexed immunoassay that can be used to accurately determine flu vaccine potency and stability in finished product and in crude samples from upstream processes.


Subject(s)
Drug Stability , Hemagglutinin Glycoproteins, Influenza Virus/analysis , Hemagglutinin Glycoproteins, Influenza Virus/immunology , Influenza Vaccines/immunology , Technology, Pharmaceutical/methods , Vaccine Potency , Humans , Immunoassay/methods , Protein Stability , Temperature , Time Factors
15.
Vaccine ; 33(44): 6025-6, 2015 Nov 04.
Article in English | MEDLINE | ID: mdl-26275481

ABSTRACT

Readers of this Special Issue of Vaccine are likely unified by a desire to enhance vaccine efficacy and improve vaccine manufacturing efficiency. For influenza vaccines, challenges to achieving those goals are many, and range from improved surveillance to less cumbersome production platforms and more reliable performance verification. Specifically, demand is growing for an alternative vaccine potency assay. Assuming that a replacement potency assay is found to be promising, one question will be: how will it be judged to be accurate? It is generally agreed that any potential replacement for SRID will have to exhibit good correlation with SRID and yield a value within ± 20% of the SRID determined potency. In my opinion, SRID itself has enough limitations that judging alternatives relative to that particular standard will not ensure that the industry as a whole transitions to an improved method. In fact, it could blind us to an assay that may ultimately provide a better predictive measure of vaccine efficacy (or immunogenicity). There is only one way to verify that measured potency is correlated with, and predictive of, measured immunogenicity - test the relationship in clinical studies.


Subject(s)
Influenza Vaccines/immunology , Influenza Vaccines/standards , Technology, Pharmaceutical/methods , Vaccine Potency , Clinical Studies as Topic , Humans
16.
PLoS One ; 9(10): e109616, 2014.
Article in English | MEDLINE | ID: mdl-25330238

ABSTRACT

Titer on Chip (Flu-ToC) is a new technique for quantification of influenza hemagglutinin (HA) concentration. In order to evaluate the potential of this new technique, a comparison of Flu-ToC to more conventional methods was conducted using recombinant HA produced in a baculovirus expression system as a test case. Samples from current vaccine strains were collected from four different steps in the manufacturing process. A total of 19 samples were analysed by Flu-ToC (blinded), single radial immunodiffusion (SRID), an enzyme-linked immunosorbent assay (ELISA), and the purity adjusted bicinchoninic acid assay (paBCA). The results indicated reasonable linear correlation between Flu-ToC and SRID, ELISA, and paBCA, with regression slopes of log-log plots being 0.91, 1.03, and 0.91, respectively. The average ratio for HA content measured by Flu-ToC relative to SRID, ELISA, and paBCA was 83%, 147%, and 81%, respectively; indicating nearly equivalent potency determination for Flu-ToC relative to SRID and paBCA. These results, combined with demonstrated multiplexed analysis of all components within a quadrivalent formulation and robust response to HA strains over a wide time period, support the conclusion that Flu-ToC can be used as a reliable and time-saving alternative potency assay for influenza vaccines.


Subject(s)
Hemagglutinin Glycoproteins, Influenza Virus/analysis , Immunoassay/methods , Influenza Vaccines/immunology , Vaccine Potency , Animals , Baculoviridae/genetics , Hemagglutinin Glycoproteins, Influenza Virus/genetics , Hemagglutinin Glycoproteins, Influenza Virus/immunology , Immunoassay/instrumentation , Recombinant Proteins/analysis , Recombinant Proteins/genetics , Recombinant Proteins/immunology , Species Specificity
17.
J Vis Exp ; (52)2011 Jun 09.
Article in English | MEDLINE | ID: mdl-21694688

ABSTRACT

DNA microarrays have emerged as a powerful tool for pathogen detection. For instance, many examples of the ability to type and subtype influenza virus have been demonstrated. The identification and subtyping of influenza on DNA microarrays has applications in both public health and the clinic for early detection, rapid intervention, and minimizing the impact of an influenza pandemic. Traditional fluorescence is currently the most commonly used microarray detection method. However, as microarray technology progresses towards clinical use, replacing expensive instrumentation with low cost detection technology exhibiting similar performance characteristics to fluorescence will make microarray assays more attractive and cost-effective. The ampliPHOX colorimetric detection technology is intended for research applications, and has a limit of detection within one order of magnitude of traditional fluorescence, with a main advantage being an approximate ten-fold lower instrument cost compared to the confocal microarray scanners required for fluorescence microarray detection. Another advantage is the compact size of the instrument which allows for portability and flexibility, unlike traditional fluorescence instruments. Because the polymerization technology is not as inherently linear as fluorescence detection, however, it is best suited for lower density microarray applications in which a yes/no answer for the presence of a certain sequence is desired, such as for pathogen detection arrays. Currently the maximum spot density compatible with ampliPHOX detection is ˜1800 spots/array. Because of the spot density limitations, higher density microarrays are not suitable for ampliPHOX detection. Here, we present ampliPHOX colorimetric detection technology as a method of signal amplification on a low density microarray developed for the detection and characterization of influenza viruses (FluChip). Although this protocol uses the FluChip (a DNA microarray) as one specific application of ampliPHOX detection, any microarray incorporating biotinylated target can be labeled and detected in a similar manner. The microarray design and biotinylation of the target to be captured are the responsibility of the user. Once the biotinylated target has been captured on the array, ampliPHOX detection can be performed by first tagging the array with a streptavidin-label conjugate (ampliTAG). Upon light exposure using the ampliPHOX Reader instrument, polymerization of a monomer solution (ampliPHY) occurs only in regions containing ampliTAG-labeled targets. The polymer formed can be subsequently stained with a non-toxic solution to improve visual contrast, followed by imaging and analysis using a simple software package (ampliVIEW). The entire FluChip assay from un-extracted sample to result can be performed in about 6 hours, and the ampliPHOX detection steps described above can be completed in about 30 min.


Subject(s)
Colorimetry/methods , Oligonucleotide Array Sequence Analysis/methods , Orthomyxoviridae/isolation & purification , Animals , Humans , Influenza A Virus, H1N1 Subtype/genetics , Influenza A Virus, H1N1 Subtype/isolation & purification , Influenza A Virus, H3N2 Subtype/genetics , Influenza A Virus, H3N2 Subtype/isolation & purification , Influenza, Human/virology , Orthomyxoviridae/genetics , Orthomyxoviridae Infections/virology , Reverse Transcriptase Polymerase Chain Reaction/methods , Swine
18.
J Virol Methods ; 171(1): 111-6, 2011 Jan.
Article in English | MEDLINE | ID: mdl-20970458

ABSTRACT

The utility of a new instrument for rapid virus quantitation, the Virus Counter, was evaluated in a blind study conducted at three sites. This instrument is a substantially improved version of the original academic research instrument described previously by Stoffel and Rowlen (2005a). The addition of hydrodynamic focusing, a self-contained fluidics system and customized software for system control and data analysis has resulted in a commercially viable and available design. Baculovirus samples were provided by Protein Sciences Corporation and blinded to InDevR and Baylor College of Medicine. Protein Sciences Corporation and Baylor College of Medicine analyzed the samples by plaque assay and InDevR analyzed the samples using the Virus Counter. Serial dilution of stock viruses into growth media and buffer allowed for comparison of measured versus intended concentrations. Direct log-scale comparison between pooled Virus Counter results and pooled plaque assay results indicated a linear relationship (slope=1.1±0.2, R(2)=0.86) with statistically significant Pearson correlation (r=0.93, p<0.001).


Subject(s)
Baculoviridae/isolation & purification , Viral Load , Viral Plaque Assay
19.
Influenza Other Respir Viruses ; 4(6): 411-6, 2010 Nov.
Article in English | MEDLINE | ID: mdl-20958936

ABSTRACT

BACKGROUND: The MChip uses data from the hybridization of amplified viral RNA to 15 distinct oligonucleotides that target the influenza A matrix (M) gene segment. An artificial neural network (ANN) automates the interpretation of subtle differences in fluorescence intensity patterns from the microarray. The complete process from clinical specimen to identification including amplification of viral RNA can be completed in <8 hours for under US$10. OBJECTIVES: The work presented here represents an effort to expand and test the capabilities of the MChip to differentiate influenza A/H1N1 of various species origin. METHODS: The MChip ANN was trained to recognize fluorescence image patterns of a variety of known influenza A viruses, including examples of human H1N1, human H3N2, swine H1N1, 2009 pandemic influenza A H1N1, and a wide variety of avian, equine, canine, and swine influenza viruses. Robustness of the MChip ANN was evaluated using 296 blinded isolates. RESULTS: Training of the ANN was expanded by the addition of 71 well-characterized influenza A isolates and yielded relatively high accuracy (little misclassification) in distinguishing unique H1N1 strains: nine human A/H1N1 (88·9% correct), 35 human A/H3N2 (97·1% correct), 31 North American swine A/H1N1 (80·6% correct), 14 2009 pandemic A/H1N1 (87·7% correct), and 23 negative samples (91·3% correct). Genetic diversity among the swine H1N1 isolates may have contributed to the lower success rate for these viruses. CONCLUSIONS: The current study demonstrates the MChip has the capability to differentiate the genetic variations among influenza viruses with appropriate ANN training. Further selective enrichment of the ANN will improve its ability to rapidly and reliably characterize influenza viruses of unknown origin.


Subject(s)
Influenza A Virus, H1N1 Subtype/classification , Influenza A Virus, H1N1 Subtype/genetics , Microarray Analysis/methods , Oligonucleotide Array Sequence Analysis/methods , Viral Matrix Proteins/genetics , Virology/methods , Animals , Humans , Microarray Analysis/economics , Neural Networks, Computer , Oligonucleotide Array Sequence Analysis/economics , Sensitivity and Specificity , Time Factors , United States , Virology/economics
20.
ACS Nano ; 4(2): 615-24, 2010 Feb 23.
Article in English | MEDLINE | ID: mdl-20112934

ABSTRACT

Disordered nanohole arrays were formed in silver films by colloidal lithography techniques and characterized for their surface-plasmon activity. Careful control of the reagent concentration, deposition solution ionic strength, and assembly time allowed generation of a wide variety of nanohole densities. The fractional coverage of the nanospheres across the surface was varied from 0.05-0.36. Electrical sheet resistance measurements as a function of nanohole coverage fit well to percolation theory indicating that the electrical behavior of the films is determined by bulk silver characteristics. The transmission and reflection spectra were measured as a function of coverage and the results indicate that the optical behavior of the films is dominated by surface plasmon phenomena. Angle-resolved transmission and reflection spectra were measured, yielding insight into the nature of the excitations taking place on the metal films. The tunability of the colloidal lithography assembly method holds much promise as a means to generate customized transparent electrodes with high surface plasmon activity throughout the visible and NIR spectrum over large surface areas.


Subject(s)
Nanostructures/chemistry , Optical Phenomena , Silver/chemistry , Colloids , Electricity , Nanospheres/chemistry , Salts/chemistry , Spectrophotometry, Infrared , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...