Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 87
Filter
1.
PLoS One ; 19(6): e0304612, 2024.
Article in English | MEDLINE | ID: mdl-38870171

ABSTRACT

A similarity-driven multi-dimensional binning algorithm (SIMBA) reconstruction of free-running cardiac magnetic resonance imaging data was previously proposed. While very efficient and fast, the original SIMBA focused only on the reconstruction of a single motion-consistent cluster, discarding the remaining data acquired. However, the redundant data clustered by similarity may be exploited to further improve image quality. In this work, we propose a novel compressed sensing (CS) reconstruction that performs an effective regularization over the clustering dimension, thanks to the integration of inter-cluster motion compensation (XD-MC-SIMBA). This reconstruction was applied to free-running ferumoxytol-enhanced datasets from 24 patients with congenital heart disease, and compared to the original SIMBA, the same XD-MC-SIMBA reconstruction but without motion compensation (XD-SIMBA), and a 5D motion-resolved CS reconstruction using the free-running framework (FRF). The resulting images were compared in terms of lung-liver and blood-myocardium sharpness, blood-myocardium contrast ratio, and visible length and sharpness of the coronary arteries. Moreover, an automated image quality score (IQS) was assigned using a pretrained deep neural network. The lung-liver sharpness and blood-myocardium sharpness were significantly higher in XD-MC-SIMBA and FRF. Consistent with these findings, the IQS analysis revealed that image quality for XD-MC-SIMBA was improved in 18 of 24 cases, compared to SIMBA. We successfully tested the hypothesis that multiple motion-consistent SIMBA clusters can be exploited to improve the quality of ferumoxytol-enhanced cardiac MRI when inter-cluster motion-compensation is integrated as part of a CS reconstruction.


Subject(s)
Algorithms , Ferrosoferric Oxide , Heart Defects, Congenital , Magnetic Resonance Imaging , Humans , Heart Defects, Congenital/diagnostic imaging , Magnetic Resonance Imaging/methods , Male , Female , Image Processing, Computer-Assisted/methods , Heart/diagnostic imaging , Heart/physiopathology , Motion , Adult , Child , Contrast Media , Adolescent , Young Adult
2.
MAGMA ; 2024 May 14.
Article in English | MEDLINE | ID: mdl-38743377

ABSTRACT

OBJECT: To enable high-quality physics-guided deep learning (PG-DL) reconstruction of large-scale 3D non-Cartesian coronary MRI by overcoming challenges of hardware limitations and limited training data availability. MATERIALS AND METHODS: While PG-DL has emerged as a powerful image reconstruction method, its application to large-scale 3D non-Cartesian MRI is hindered by hardware limitations and limited availability of training data. We combine several recent advances in deep learning and MRI reconstruction to tackle the former challenge, and we further propose a 2.5D reconstruction using 2D convolutional neural networks, which treat 3D volumes as batches of 2D images to train the network with a limited amount of training data. Both 3D and 2.5D variants of the PG-DL networks were compared to conventional methods for high-resolution 3D kooshball coronary MRI. RESULTS: Proposed PG-DL reconstructions of 3D non-Cartesian coronary MRI with 3D and 2.5D processing outperformed all conventional methods both quantitatively and qualitatively in terms of image assessment by an experienced cardiologist. The 2.5D variant further improved vessel sharpness compared to 3D processing, and scored higher in terms of qualitative image quality. DISCUSSION: PG-DL reconstruction of large-scale 3D non-Cartesian MRI without compromising image size or network complexity is achieved, and the proposed 2.5D processing enables high-quality reconstruction with limited training data.

3.
Ann Intern Med ; 177(6): 738-748, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38710086

ABSTRACT

BACKGROUND: Despite considerable emphasis on delivering safe care, substantial patient harm occurs. Although most care occurs in the outpatient setting, knowledge of outpatient adverse events (AEs) remains limited. OBJECTIVE: To measure AEs in the outpatient setting. DESIGN: Retrospective review of the electronic health record (EHR). SETTING: 11 outpatient sites in Massachusetts in 2018. PATIENTS: 3103 patients who received outpatient care. MEASUREMENTS: Using a trigger method, nurse reviewers identified possible AEs and physicians adjudicated them, ranked severity, and assessed preventability. Generalized estimating equations were used to assess the association of having at least 1 AE with age, sex, race, and primary insurance. Variation in AE rates was analyzed across sites. RESULTS: The 3103 patients (mean age, 52 years) were more often female (59.8%), White (75.1%), English speakers (90.8%), and privately insured (70.4%) and had a mean of 4 outpatient encounters in 2018. Overall, 7.0% (95% CI, 4.6% to 9.3%) of patients had at least 1 AE (8.6 events per 100 patients annually). Adverse drug events were the most common AE (63.8%), followed by health care-associated infections (14.8%) and surgical or procedural events (14.2%). Severity was serious in 17.4% of AEs, life-threatening in 2.1%, and never fatal. Overall, 23.2% of AEs were preventable. Having at least 1 AE was less often associated with ages 18 to 44 years than with ages 65 to 84 years (standardized risk difference, -0.05 [CI, -0.09 to -0.02]) and more often associated with Black race than with Asian race (standardized risk difference, 0.09 [CI, 0.01 to 0.17]). Across study sites, 1.8% to 23.6% of patients had at least 1 AE and clinical category of AEs varied substantially. LIMITATION: Retrospective EHR review may miss AEs. CONCLUSION: Outpatient harm was relatively common and often serious. Adverse drug events were most frequent. Rates were higher among older adults. Interventions to curtail outpatient harm are urgently needed. PRIMARY FUNDING SOURCE: Controlled Risk Insurance Company and the Risk Management Foundation of the Harvard Medical Institutions.


Subject(s)
Ambulatory Care , Electronic Health Records , Patient Safety , Humans , Female , Middle Aged , Male , Retrospective Studies , Adult , Aged , Massachusetts , Adolescent , Young Adult
5.
J Cardiovasc Magn Reson ; 26(1): 101037, 2024.
Article in English | MEDLINE | ID: mdl-38499269

ABSTRACT

BACKGROUND: Free-running cardiac and respiratory motion-resolved whole-heart five-dimensional (5D) cardiovascular magnetic resonance (CMR) can reduce scan planning and provide a means of evaluating respiratory-driven changes in clinical parameters of interest. However, respiratory-resolved imaging can be limited by user-defined parameters which create trade-offs between residual artifact and motion blur. In this work, we develop and validate strategies for both correction of intra-bin and compensation of inter-bin respiratory motion to improve the quality of 5D CMR. METHODS: Each component of the reconstruction framework was systematically validated and compared to the previously established 5D approach using simulated free-running data (N = 50) and a cohort of 32 patients with congenital heart disease. The impact of intra-bin respiratory motion correction was evaluated in terms of image sharpness while inter-bin respiratory motion compensation was evaluated in terms of reconstruction error, compression of respiratory motion, and image sharpness. The full reconstruction framework (intra-acquisition correction and inter-acquisition compensation of respiratory motion [IIMC] 5D) was evaluated in terms of image sharpness and scoring of image quality by expert reviewers. RESULTS: Intra-bin motion correction provides significantly (p < 0.001) sharper images for both simulated and patient data. Inter-bin motion compensation results in significant (p < 0.001) lower reconstruction error, lower motion compression, and higher sharpness in both simulated (10/11) and patient (9/11) data. The combined framework resulted in significantly (p < 0.001) sharper IIMC 5D reconstructions (End-expiration (End-Exp): 0.45 ± 0.09, End-inspiration (End-Ins): 0.46 ± 0.10) relative to the previously established 5D implementation (End-Exp: 0.43 ± 0.08, End-Ins: 0.39 ± 0.09). Similarly, image scoring by three expert reviewers was significantly (p < 0.001) higher using IIMC 5D (End-Exp: 3.39 ± 0.44, End-Ins: 3.32 ± 0.45) relative to 5D images (End-Exp: 3.02 ± 0.54, End-Ins: 2.45 ± 0.52). CONCLUSION: The proposed IIMC reconstruction significantly improves the quality of 5D whole-heart MRI. This may be exploited for higher resolution or abbreviated scanning. Further investigation of the diagnostic impact of this framework and comparison to gold standards is needed to understand its full clinical utility, including exploration of respiratory-driven changes in physiological measurements of interest.


Subject(s)
Artifacts , Heart Defects, Congenital , Image Interpretation, Computer-Assisted , Predictive Value of Tests , Humans , Reproducibility of Results , Female , Male , Heart Defects, Congenital/diagnostic imaging , Heart Defects, Congenital/physiopathology , Adult , Young Adult , Magnetic Resonance Imaging , Adolescent , Respiratory Mechanics , Respiratory-Gated Imaging Techniques , Child , Middle Aged , Respiration , Magnetic Resonance Imaging, Cine
6.
J Cardiovasc Magn Reson ; 26(1): 101006, 2024.
Article in English | MEDLINE | ID: mdl-38309581

ABSTRACT

BACKGROUND: Four-dimensional (4D) flow magnetic resonance imaging (MRI) often relies on the injection of gadolinium- or iron-oxide-based contrast agents to improve vessel delineation. In this work, a novel technique is developed to acquire and reconstruct 4D flow data with excellent dynamic visualization of blood vessels but without the need for contrast injection. Synchronization of Neighboring Acquisitions by Physiological Signals (SyNAPS) uses pilot tone (PT) navigation to retrospectively synchronize the reconstruction of two free-running three-dimensional radial acquisitions, to create co-registered anatomy and flow images. METHODS: Thirteen volunteers and two Marfan syndrome patients were scanned without contrast agent using one free-running fast interrupted steady-state (FISS) sequence and one free-running phase-contrast MRI (PC-MRI) sequence. PT signals spanning the two sequences were recorded for retrospective respiratory motion correction and cardiac binning. The magnitude and phase images reconstructed, respectively, from FISS and PC-MRI, were synchronized to create SyNAPS 4D flow datasets. Conventional two-dimensional (2D) flow data were acquired for reference in ascending (AAo) and descending aorta (DAo). The blood-to-myocardium contrast ratio, dynamic vessel area, net volume, and peak flow were used to compare SyNAPS 4D flow with Native 4D flow (without FISS information) and 2D flow. A score of 0-4 was given to each dataset by two blinded experts regarding the feasibility of performing vessel delineation. RESULTS: Blood-to-myocardium contrast ratio for SyNAPS 4D flow magnitude images (1.5 ± 0.3) was significantly higher than for Native 4D flow (0.7 ± 0.1, p < 0.01) and was comparable to 2D flow (2.3 ± 0.9, p = 0.02). Image quality scores of SyNAPS 4D flow from the experts (M.P.: 1.9 ± 0.3, E.T.: 2.5 ± 0.5) were overall significantly higher than the scores from Native 4D flow (M.P.: 1.6 ± 0.6, p = 0.03, E.T.: 0.8 ± 0.4, p < 0.01) but still significantly lower than the scores from the reference 2D flow datasets (M.P.: 2.8 ± 0.4, p < 0.01, E.T.: 3.5 ± 0.7, p < 0.01). The Pearson correlation coefficient between the dynamic vessel area measured on SyNAPS 4D flow and that from 2D flow was 0.69 ± 0.24 for the AAo and 0.83 ± 0.10 for the DAo, whereas the Pearson correlation between Native 4D flow and 2D flow measurements was 0.12 ± 0.48 for the AAo and 0.08 ± 0.39 for the DAo. Linear correlations between SyNAPS 4D flow and 2D flow measurements of net volume (r2 = 0.83) and peak flow (r2 = 0.87) were larger than the correlations between Native 4D flow and 2D flow measurements of net volume (r2 = 0.79) and peak flow (r2 = 0.76). CONCLUSION: The feasibility and utility of SyNAPS were demonstrated for joint whole-heart anatomical and flow MRI without requiring electrocardiography gating, respiratory navigators, or contrast agents. Using SyNAPS, a high-contrast anatomical imaging sequence can be used to improve 4D flow measurements that often suffer from poor delineation of vessel boundaries in the absence of contrast agents.


Subject(s)
Image Interpretation, Computer-Assisted , Marfan Syndrome , Predictive Value of Tests , Regional Blood Flow , Humans , Blood Flow Velocity , Adult , Male , Marfan Syndrome/physiopathology , Female , Young Adult , Case-Control Studies , Magnetic Resonance Angiography , Reproducibility of Results , Feasibility Studies , Hemodynamics , Perfusion Imaging/methods , Contrast Media/administration & dosage , Time Factors , Middle Aged
7.
PNAS Nexus ; 2(11): pgad394, 2023 Nov.
Article in English | MEDLINE | ID: mdl-38024395

ABSTRACT

Tolerogenic ImmTOR nanoparticles encapsulating rapamycin have been demonstrated to mitigate immunogenicity of adeno-associated virus (AAV) gene therapy vectors, enhance levels of transgene expression, and enable redosing of AAV at moderate vector doses of 2 to 5E12 vg/kg. However, recent clinical trials have often pushed AAV vector doses 10-fold to 50-fold higher, with serious adverse events observed at the upper range. Here, we assessed combination therapy of ImmTOR with B cell-targeting drugs for the ability to increase the efficiency of redosing at high vector doses. The combination of ImmTOR with a monoclonal antibody against B cell activation factor (aBAFF) exhibited strong synergy leading to more than a 5-fold to 10-fold reduction of splenic mature B cells and plasmablasts while increasing the fraction of pre-/pro-B cells. In addition, this combination dramatically reduced anti-AAV IgM and IgG antibodies, thus enabling four successive AAV administrations at doses up to 5E12 vg/kg and at least two AAV doses at 5E13 vg/kg, with the transgene expression level in the latter case being equal to that observed in control animals receiving a single vector dose of 1E14 vg/kg. Similar synergistic effects were seen with a combination of ImmTOR and a Bruton's tyrosine kinase inhibitor, ibrutinib. These results suggest that ImmTOR could be combined with B cell-targeting agents to enable repeated vector administrations as a potential strategy to avoid toxicities associated with vector doses above 1E14 vg/kg.

8.
J Autoimmun ; 140: 103125, 2023 Oct 14.
Article in English | MEDLINE | ID: mdl-37844543

ABSTRACT

Interleukin-2 (IL-2) therapies targeting the high affinity IL-2 receptor expressed on regulatory T cells (Tregs) have shown promising therapeutic benefit in autoimmune diseases through nonselective expansion of pre-existing Treg populations, but are potentially limited by the inability to induce antigen-specific Tregs, as well as by dose-limiting activation of effector immune cells in settings of inflammation. We recently developed biodegradable nanoparticles encapsulating rapamycin, called ImmTOR, which induce selective immune tolerance to co-administered antigens but do not increase total Treg numbers. Here we demonstrate that the combination of ImmTOR and an engineered Treg-selective IL-2 variant (termed IL-2 mutein) increases the number and durability of total Tregs, as well as inducing a profound synergistic increase in antigen-specific Tregs when combined with a target antigen. We demonstrate that the combination of ImmTOR and an IL-2 mutein leads to durable inhibition of antibody responses to co-administered AAV gene therapy capsid, even at sub-optimal doses of ImmTOR, and provides protection in autoimmune models of type 1 diabetes and primary biliary cholangitis. Importantly, ImmTOR also increases the therapeutic window of engineered IL-2 molecules by mitigating effector immune cell expansion and preventing exacerbation of disease in a model of graft-versus-host-disease. At the same time, IL-2 mutein shows potential for dose-sparing of ImmTOR. Overall, these results establish that the combination of ImmTOR and an IL-2 mutein show synergistic benefit on both safety and efficacy to provide durable antigen-specific immune tolerance to mitigate drug immunogenicity and to treat autoimmune diseases.

9.
bioRxiv ; 2023 May 15.
Article in English | MEDLINE | ID: mdl-37425913

ABSTRACT

Functional magnetic resonance imaging (fMRI) is a methodological cornerstone of neuroscience. Most studies measure blood-oxygen-level-dependent (BOLD) signal using echo-planar imaging (EPI), Cartesian sampling, and image reconstruction with a one-to-one correspondence between the number of acquired volumes and reconstructed images. However, EPI schemes are subject to trade-offs between spatial and temporal resolutions. We overcome these limitations by measuring BOLD with a gradient recalled echo (GRE) with 3D radial-spiral phyllotaxis trajectory at a high sampling rate (28.24ms) on standard 3T field-strength. The framework enables the reconstruction of 3D signal time courses with whole-brain coverage at simultaneously higher spatial (1mm 3 ) and temporal (up to 250ms) resolutions, as compared to optimized EPI schemes. Additionally, artifacts are corrected before image reconstruction; the desired temporal resolution is chosen after scanning and without assumptions on the shape of the hemodynamic response. By showing activation in the calcarine sulcus of 20 participants performing an ON-OFF visual paradigm, we demonstrate the reliability of our method for cognitive neuroscience research.

10.
Int Dent J ; 73(6): 862-872, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37316411

ABSTRACT

OBJECTIVE: The aim of this research was to investigate the role of the cornified epithelium, the outermost layer of the oral mucosa, engineered to prevent water loss and microorganism invasion, in severe forms of periodontitis (stage III or IV, grade C). METHODS: Porphyromonas gingivalis, a major periodontal disease pathogen, can affect cornified epithelial protein expression through chronic activation of signal transducer and activator of transcription 6 (Stat6). We used a mouse model, Stat6VT, that mimics this to determine the effects of barrier defect on P gingivalis-induced inflammation, bone loss, and cornified epithelial protein expression, and compared histologic and immunohistologic findings with tissues obtained from human controls and patients with stage III and IV, grade C disease. Alveolar bone loss in mice was assessed using micro-computerised tomography, and soft tissue morphology was qualitatively and semi-quantitatively assessed by histologic examination for several proteins, including loricrin, filaggrin, cytokeratin 1, cytokeratin 14, a proliferation marker, a pan-leukocyte marker, as well as morphologic signs of inflammation. Relative cytokine levels were measured in mouse plasma by cytokine array. RESULTS: In the tissues from patients with periodontal disease, there were greater signs of inflammation (rete pegs, clear cells, inflammatory infiltrates) and a decrease and broadening of expression of loricrin and cytokeratin 1. Cytokeratin 14 expression was also broader and decreased in stage IV. P gingivalis-infected Stat6VT mice showed greater alveolar bone loss in 9 out of 16 examined sites, and similar patterns of disruption to human patients in expression of loricrin and cytokeratins 1 and 14. There were also increased numbers of leukocytes, decreased proliferation, and greater signs of inflammation compared with P gingivalis-infected control mice. CONCLUSIONS: Our study provides evidence that changes in epithelial organisation can exacerbate the effects of P gingivalis infection, with similarities to the most severe forms of human periodontitis.


Subject(s)
Alveolar Bone Loss , Periodontitis , Humans , Mice , Animals , Alveolar Bone Loss/pathology , Keratin-14 , Keratins , Inflammation/pathology , Cytokines/metabolism , Porphyromonas gingivalis
11.
Magn Reson Med ; 90(3): 922-938, 2023 09.
Article in English | MEDLINE | ID: mdl-37103471

ABSTRACT

PURPOSE: To develop a free-running 3D radial whole-heart multiecho gradient echo (ME-GRE) framework for cardiac- and respiratory-motion-resolved fat fraction (FF) quantification. METHODS: (NTE = 8) readouts optimized for water-fat separation and quantification were integrated within a continuous non-electrocardiogram-triggered free-breathing 3D radial GRE acquisition. Motion resolution was achieved with pilot tone (PT) navigation, and the extracted cardiac and respiratory signals were compared to those obtained with self-gating (SG). After extra-dimensional golden-angle radial sparse parallel-based image reconstruction, FF, R2 *, and B0 maps, as well as fat and water images were generated with a maximum-likelihood fitting algorithm. The framework was tested in a fat-water phantom and in 10 healthy volunteers at 1.5 T using NTE = 4 and NTE = 8 echoes. The separated images and maps were compared with a standard free-breathing electrocardiogram (ECG)-triggered acquisition. RESULTS: The method was validated in vivo, and physiological motion was resolved over all collected echoes. Across volunteers, PT provided respiratory and cardiac signals in agreement (r = 0.91 and r = 0.72) with SG of the first echo, and a higher correlation to the ECG (0.1% of missed triggers for PT vs. 5.9% for SG). The framework enabled pericardial fat imaging and quantification throughout the cardiac cycle, revealing a decrease in FF at end-systole by 11.4% ± 3.1% across volunteers (p < 0.0001). Motion-resolved end-diastolic 3D FF maps showed good correlation with ECG-triggered measurements (FF bias of -1.06%). A significant difference in free-running FF measured with NTE = 4 and NTE = 8 was found (p < 0.0001 in sub-cutaneous fat and p < 0.01 in pericardial fat). CONCLUSION: Free-running fat fraction mapping was validated at 1.5 T, enabling ME-GRE-based fat quantification with NTE = 8 echoes in 6:15 min.


Subject(s)
Heart , Magnetic Resonance Imaging , Humans , Magnetic Resonance Imaging/methods , Heart/diagnostic imaging , Electrocardiography , Image Processing, Computer-Assisted/methods , Respiration , Imaging, Three-Dimensional/methods
12.
Magn Reson Med ; 90(1): 117-132, 2023 07.
Article in English | MEDLINE | ID: mdl-36877140

ABSTRACT

PURPOSE: To validate a respiratory motion correction method called focused navigation (fNAV) for free-running radial whole-heart 4D flow MRI. METHODS: Using fNAV, respiratory signals derived from radial readouts are converted into three orthogonal displacements, which are then used to correct respiratory motion in 4D flow datasets. Hundred 4D flow acquisitions were simulated with non-rigid respiratory motion and used for validation. The difference between generated and fNAV displacement coefficients was calculated. Vessel area and flow measurements from 4D flow reconstructions with (fNAV) and without (uncorrected) motion correction were compared to the motion-free ground-truth. In 25 patients, the same measurements were compared between fNAV 4D flow, 2D flow, navigator-gated Cartesian 4D flow, and uncorrected 4D flow datasets. RESULTS: For simulated data, the average difference between generated and fNAV displacement coefficients was 0.04 ± $$ \pm $$ 0.32 mm and 0.31 ± $$ \pm $$ 0.35 mm in the x and y directions, respectively. In the z direction, this difference was region-dependent (0.02 ± $$ \pm $$ 0.51 mm up to 5.85 ± $$ \pm $$ 3.41 mm). For all measurements (vessel area, net volume, and peak flow), the average difference from ground truth was higher for uncorrected 4D flow datasets (0.32 ± $$ \pm $$ 0.11 cm2 , 11.1 ± $$ \pm $$ 3.5 mL, and 22.3 ± $$ \pm $$ 6.0 mL/s) than for fNAV 4D flow datasets (0.10 ± $$ \pm $$ 0.03 cm2 , 2.6 ± $$ \pm $$ 0.7 mL, and 5.1 ± 0 $$ \pm 0 $$ .9 mL/s, p < 0.05). In vivo, average vessel area measurements were 4.92 ± $$ \pm $$ 2.95 cm2 , 5.06 ± $$ \pm $$ 2.64 cm2 , 4.87 ± $$ \pm $$ 2.57 cm2 , 4.87 ± $$ \pm $$ 2.69 cm2 , for 2D flow and fNAV, navigator-gated and uncorrected 4D flow datasets, respectively. In the ascending aorta, all 4D flow datasets except for the fNAV reconstruction had significantly different vessel area measurements from 2D flow. Overall, 2D flow datasets demonstrated the strongest correlation to fNAV 4D flow for both net volume (r2  = 0.92) and peak flow (r2  = 0.94), followed by navigator-gated 4D flow (r2  = 0.83 and r2  = 0.86, respectively), and uncorrected 4D flow (r2  = 0.69 and r2  = 0.86, respectively). CONCLUSION: fNAV corrected respiratory motion in vitro and in vivo, resulting in fNAV 4D flow measurements that are comparable to those derived from 2D flow and navigator-gated Cartesian 4D flow datasets, with improvements over those from uncorrected 4D flow.


Subject(s)
Magnetic Resonance Imaging , Respiratory Rate , Humans , Magnetic Resonance Imaging/methods , Motion , Aorta , Imaging, Three-Dimensional/methods
13.
N Engl J Med ; 388(2): 142-153, 2023 01 12.
Article in English | MEDLINE | ID: mdl-36630622

ABSTRACT

BACKGROUND: Adverse events during hospitalization are a major cause of patient harm, as documented in the 1991 Harvard Medical Practice Study. Patient safety has changed substantially in the decades since that study was conducted, and a more current assessment of harm during hospitalization is warranted. METHODS: We conducted a retrospective cohort study to assess the frequency, preventability, and severity of patient harm in a random sample of admissions from 11 Massachusetts hospitals during the 2018 calendar year. The occurrence of adverse events was assessed with the use of a trigger method (identification of information in a medical record that was previously shown to be associated with adverse events) and from review of medical records. Trained nurses reviewed records and identified admissions with possible adverse events that were then adjudicated by physicians, who confirmed the presence and characteristics of the adverse events. RESULTS: In a random sample of 2809 admissions, we identified at least one adverse event in 23.6%. Among 978 adverse events, 222 (22.7%) were judged to be preventable and 316 (32.3%) had a severity level of serious (i.e., caused harm that resulted in substantial intervention or prolonged recovery) or higher. A preventable adverse event occurred in 191 (6.8%) of all admissions, and a preventable adverse event with a severity level of serious or higher occurred in 29 (1.0%). There were seven deaths, one of which was deemed to be preventable. Adverse drug events were the most common adverse events (accounting for 39.0% of all events), followed by surgical or other procedural events (30.4%), patient-care events (which were defined as events associated with nursing care, including falls and pressure ulcers) (15.0%), and health care-associated infections (11.9%). CONCLUSIONS: Adverse events were identified in nearly one in four admissions, and approximately one fourth of the events were preventable. These findings underscore the importance of patient safety and the need for continuing improvement. (Funded by the Controlled Risk Insurance Company and the Risk Management Foundation of the Harvard Medical Institutions.).


Subject(s)
Delivery of Health Care , Hospitalization , Medical Errors , Patient Harm , Patient Safety , Humans , Delivery of Health Care/standards , Delivery of Health Care/statistics & numerical data , Drug-Related Side Effects and Adverse Reactions/epidemiology , Drug-Related Side Effects and Adverse Reactions/prevention & control , Hospitalization/statistics & numerical data , Inpatients , Medical Errors/prevention & control , Medical Errors/statistics & numerical data , Patient Safety/standards , Retrospective Studies , Patient Harm/prevention & control , Patient Harm/statistics & numerical data
14.
J Law Med Ethics ; 51(4): 954-955, 2023.
Article in English | MEDLINE | ID: mdl-38477265
15.
J Cardiovasc Dev Dis ; 9(11)2022 Nov 18.
Article in English | MEDLINE | ID: mdl-36421934

ABSTRACT

The 2019 Global Burden of Disease (GBD) study estimated that there were approximately 24.2 million people affected worldwide by degenerative mitral regurgitation (MR), resulting in 34,200 deaths. After aortic stenosis, MR is the most prevalent VHD in Europe and the second-most common VHD to pose indications for surgery in western countries. Current ESC and AHA/ACC guidelines for the management of VHD emphasize the importance of an integrative approach for the assessment of MR severity, which is of paramount importance in dictating the timing for surgery. Transthoracic echocardiography (TTE) and transesophageal echocardiography (TEE) are the first-line imaging modalities; however, despite the technological advancement, sometimes, the final diagnosis on the degree of the disease may still be challenging. In the last 20 years, CMR has emerged as a robust technique in the assessment of patients with cardiac disease, and, recently, its role is gaining more and more importance in the field of VHD. In fact, CMR is the gold standard in the assessment of cardiac volumes, and it is possible to accurately evaluate the regurgitant volume. The purpose of this review is to outline the current state-of-the-art management of MR by using Cardiac Magnetic Resonance (CMR).

16.
J Cardiovasc Magn Reson ; 24(1): 39, 2022 06 27.
Article in English | MEDLINE | ID: mdl-35754040

ABSTRACT

BACKGROUND: Coronary cardiovascular magnetic resonance angiography (CCMRA) of congenital heart disease (CHD) in pediatric patients requires accurate planning, adequate sequence parameter adjustments, lengthy scanning sessions, and significant involvement from highly trained personnel. Anesthesia and intubation are commonplace to minimize movements and control respiration in younger subjects. To address the above concerns and provide a single-click imaging solution, we applied our free-running framework for fully self-gated (SG) free-breathing 5D whole-heart CCMRA to CHD patients after ferumoxytol injection. We tested the hypothesis that spatial and motion resolution suffice to visualize coronary artery ostia in a cohort of CHD subjects, both for intubated and free-breathing acquisitions. METHODS: In 18 pediatric CHD patients, non-electrocardiogram (ECG) triggered 5D free-running gradient echo CCMRA with whole-heart 1 mm3 isotropic spatial resolution was performed in seven minutes on a 1.5T CMR scanner. Eleven patients were anesthetized and intubated, while seven were breathing freely without anesthesia. All patients were slowly injected with ferumoxytol (4 mg/kg) over 15 minutes. Cardiac and respiratory motion-resolved 5D images were reconstructed with a fully SG approach. To evaluate the performance of motion resolution, visibility of coronary artery origins was assessed. Intubated and free-breathing patient sub-groups were compared for image quality using coronary artery length and conspicuity as well as lung-liver interface sharpness. RESULTS: Data collection using the free-running framework was successful in all patients in less than 8 min; scan planning was very simple without the need for parameter adjustments, while no ECG lead placement and triggering was required. From the resulting SG 5D motion-resolved reconstructed images, coronary artery origins could be retrospectively extracted in 90% of the cases. These general findings applied to both intubated and free-breathing pediatric patients (no difference in terms of lung-liver interface sharpness), while image quality and coronary conspicuity between both cohorts was very similar. CONCLUSIONS: A simple-to-use push-button framework for 5D whole-heart CCMRA was successfully employed in pediatric CHD patients with ferumoxytol injection. This approach, working without any external gating and for a wide range of heart rates and body sizes provided excellent definition of cardiac anatomy for both intubated and free-breathing patients.


Subject(s)
Heart Defects, Congenital , Magnetic Resonance Angiography , Child , Coronary Angiography/methods , Coronary Vessels/diagnostic imaging , Coronary Vessels/pathology , Ferrosoferric Oxide , Heart Defects, Congenital/diagnostic imaging , Heart Defects, Congenital/pathology , Humans , Imaging, Three-Dimensional/methods , Lung , Magnetic Resonance Angiography/methods , Predictive Value of Tests , Respiration , Retrospective Studies
17.
Sci Rep ; 12(1): 8682, 2022 05 23.
Article in English | MEDLINE | ID: mdl-35606398

ABSTRACT

Accurate characterization of in utero human brain maturation is critical as it involves complex and interconnected structural and functional processes that may influence health later in life. Magnetic resonance imaging is a powerful tool to investigate equivocal neurological patterns during fetal development. However, the number of acquisitions of satisfactory quality available in this cohort of sensitive subjects remains scarce, thus hindering the validation of advanced image processing techniques. Numerical phantoms can mitigate these limitations by providing a controlled environment with a known ground truth. In this work, we present FaBiAN, an open-source Fetal Brain magnetic resonance Acquisition Numerical phantom that simulates clinical T2-weighted fast spin echo sequences of the fetal brain. This unique tool is based on a general, flexible and realistic setup that includes stochastic fetal movements, thus providing images of the fetal brain throughout maturation comparable to clinical acquisitions. We demonstrate its value to evaluate the robustness and optimize the accuracy of an algorithm for super-resolution fetal brain magnetic resonance imaging from simulated motion-corrupted 2D low-resolution series compared to a synthetic high-resolution reference volume. We also show that the images generated can complement clinical datasets to support data-intensive deep learning methods for fetal brain tissue segmentation.


Subject(s)
Image Processing, Computer-Assisted , Magnetic Resonance Imaging , Brain/diagnostic imaging , Humans , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Magnetic Resonance Spectroscopy , Phantoms, Imaging
18.
Respir Med Case Rep ; 37: 101624, 2022.
Article in English | MEDLINE | ID: mdl-35309976

ABSTRACT

Our patient was incidentally discovered to have a filamentous foreign object penetrating his left mainstem bronchus during EBUS, with subsequent successful forceps extraction. Temporary epicardial pacing wires (TEPW) are commonly retained during coronary artery bypass surgery. Significant migration of these wires is extremely rare, and in certain instances of airway penetration they are amenable to extraction by bronchoscopy. The risk factors for significant migration, and potential consequences of such events are not well understood currently. Elucidating these elements should be of great interest to cardiac surgery, thoracic surgery, and pulmonary medicine.

19.
Magn Reson Med ; 87(2): 718-732, 2022 02.
Article in English | MEDLINE | ID: mdl-34611923

ABSTRACT

PURPOSE: In this work, we integrated the pilot tone (PT) navigation system into a reconstruction framework for respiratory and cardiac motion-resolved 5D flow. We tested the hypotheses that PT would provide equivalent respiratory curves, cardiac triggers, and corresponding flow measurements to a previously established self-gating (SG) technique while being independent from changes to the acquisition parameters. METHODS: Fifteen volunteers and 9 patients were scanned with a free-running 5D flow sequence, with PT integrated. Respiratory curves and cardiac triggers from PT and SG were compared across all subjects. Flow measurements from 5D flow reconstructions using both PT and SG were compared to each other and to a reference electrocardiogram-gated and respiratory triggered 4D flow acquisition. Radial trajectories with variable readouts per interleave were also tested in 1 subject to compare cardiac trigger quality between PT and SG. RESULTS: The correlation between PT and SG respiratory curves were 0.95 ± 0.06 for volunteers and 0.95 ± 0.04 for patients. Heartbeat duration measurements in volunteers and patients showed a bias to electrocardiogram measurements of, respectively, 0.16 ± 64.94 ms and 0.01 ± 39.29 ms for PT versus electrocardiogram and of 0.24 ± 63.68 ms and 0.09 ± 32.79 ms for SG versus electrocardiogram. No significant differences were reported for the flow measurements between 5D flow PT and from 5D flow SG. A decrease in the cardiac triggering quality of SG was observed for increasing readouts per interleave, whereas PT quality remained constant. CONCLUSION: PT has been successfully integrated in 5D flow MRI and has shown equivalent results to the previously described 5D flow SG technique, while being completely acquisition-independent.


Subject(s)
Heart , Magnetic Resonance Imaging , Electrocardiography , Heart/diagnostic imaging , Humans , Motion , Respiration , Respiratory Rate
20.
Int Dent J ; 72(1): 37-51, 2022 Feb.
Article in English | MEDLINE | ID: mdl-34565546

ABSTRACT

There is substantial evidence in support of an association between periodontitis and cardiovascular disease. The most important open question related to this association is causality. This article revisits the question of causality by reviewing intervention studies and systematic reviews and meta analyses published in the last 3 years. Where are we now in answering this question? Whilst systematic reviews and epidemiological studies continue to support an association between the diseases, intervention studies fall short in determining causality. There is a dearth of good-quality, blinded randomised control trials with cardiovascular disease outcomes. Most studies use surrogate markers/biomarkers for endpoints, and this is problematic as they may not be reflective of cardiovascular disease status. This review further highlights another issue with surrogate markers/biomarkers: the potential for collider bias. Ethical considerations surrounding nontreatment have led to calls for a well-annotated database containing in-depth dental health data. Finally, a relatively new and important risk factor for cardiovascular disease, clonal haematopoiesis of indeterminate potential, is discussed. Clonal haematopoiesis of indeterminate potential increases cardiovascular risk by more than 40%, and inflammation is a contributing factor. The impact of periodontal disease on this emerging risk factor has yet to be explored. Although the question of causality in the association between periodontal disease and cardiovascular disease remains unanswered, the importance of good oral health in maintaining good heart health is reiterated.


Subject(s)
Cardiovascular Diseases , Periodontal Diseases , Periodontitis , Cardiovascular Diseases/epidemiology , Cardiovascular Diseases/etiology , Humans , Periodontitis/complications , Periodontitis/epidemiology , Risk Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...