1.
J Biomed Opt ; 15(5): 055011, 2010.
Article in English | MEDLINE | ID: mdl-21054093

ABSTRACT

The feasibility of air-coupled ultrasound transducers to detect laser-induced ultrasound from artificial blood vessels embedded in an optically scattering phantom is demonstrated. These air-coupled transducers allow new applications in biomedical photoacoustic imaging where contact with tissue is not preferred. One promising application of such transducers is the addition of photoacoustic imaging to the regular x-ray mammographic screening procedure.


Subject(s)
Phantoms, Imaging , Ultrasonography, Mammary/methods , Acoustics , Blood Vessels/diagnostic imaging , Breast Neoplasms/blood supply , Breast Neoplasms/diagnosis , Breast Neoplasms/diagnostic imaging , Female , Humans , Lasers , Optical Phenomena , Signal Processing, Computer-Assisted , Transducers
2.
J Biophotonics ; 2(12): 701-17, 2009 Dec.
Article in English | MEDLINE | ID: mdl-19718681

ABSTRACT

Photoacoustic imaging is a hybrid imaging modality based on the detection of acoustic waves generated by the absorption of short laser pulses in biological tissue. It combines the advantages of excellent contrast achieved in optical techniques with the high resolution of ultrasound imaging. In this article we present a review of the work done at the University of Twente to image tumor angiogenesis in vivo using this technique. We start with a description and the technical details of the different photoacoustic systems developed in our laboratory, with their validation on phantoms. We then discuss small-animal studies with results of serial imaging of angiogenesis over a 10-day period at the site of tumor induction in a rat. Further, we present clinical results using a photoacoustic mammoscope of breast cancer imaging based on angiogenesis-driven optical absorption contrast.


Subject(s)
Acoustics , Light , Molecular Imaging/methods , Neoplasms/blood supply , Neovascularization, Pathologic , Animals , Humans , Image Processing, Computer-Assisted , Molecular Imaging/instrumentation
3.
J Biomed Opt ; 13(5): 050510, 2008.
Article in English | MEDLINE | ID: mdl-19021380

ABSTRACT

A real-time photoacoustic imaging system is designed and built. This system is based on a commercially available ultrasound imaging system. It can achieve a frame rate of 8 frames/sec. Vasculature in the hand of a human volunteer is imaged, and the resulting photoacoustic image is combined with the ultrasound image. The real-time photo acoustic imaging system with a hybrid ultrasound probe is demonstrated by imaging the branching of subcutaneous blood vessels in the hand.


Subject(s)
Elasticity Imaging Techniques/instrumentation , Hemoglobins/analysis , Skin Physiological Phenomena , Skin/blood supply , Transducers , Computer Systems , Elasticity Imaging Techniques/methods , Equipment Design , Equipment Failure Analysis , Humans
4.
Lasers Surg Med ; 40(3): 178-82, 2008 Mar.
Article in English | MEDLINE | ID: mdl-18366079

ABSTRACT

BACKGROUND AND OBJECTIVE: To optimize laser therapy of port-wine stains (PWSs), information about the vasculature as well as lesion depth is valuable. In this study we investigated the use of photoacoustic imaging (PAI) to obtain this information. STUDY DESIGN/MATERIALS AND METHODS: PAI uses pulsed light to generate ultrasound upon absorption of short light pulses by blood. In this study we used PAI to image vasculature in PWSs in three human volunteers. Two-dimensional imaging (scan direction vs. depth) was carried out by scanning a double-ring photoacoustic sensor over the tissue surface. RESULTS: In the photoacoustic images we observed an increased photoacoustic signal intensity at the locations of the PWS that is associated with increased vascularization. From the obtained images we measured the thickness of the vascular layer and estimated lesion depth. In some cases single vessels could be observed at the position of the PWS whereas in other cases the PWS appeared as a region with large photoacoustic signal intensity. CONCLUSIONS: PAI has the potential to reveal information about the lesion depth as well as thickness of the vascular layer.


Subject(s)
Acoustics , Lasers, Solid-State , Port-Wine Stain/pathology , Signal Processing, Computer-Assisted , Adolescent , Adult , Face/blood supply , Female , Humans , Male , Middle Aged , Neck/blood supply , Port-Wine Stain/physiopathology , Regional Blood Flow/physiology , Reproducibility of Results
5.
Lasers Surg Med ; 38(8): 740-4, 2006 Sep.
Article in English | MEDLINE | ID: mdl-16927369

ABSTRACT

BACKGROUND AND OBJECTIVES: In intravenous access to veins there is a risk of puncturing venous valves or blocking of the catheter by the valves. Therefore, we have investigated whether and how photoacoustic imaging (PAI), which visualizes the lumen of blood vessels, can be used to detect these valves. STUDY DESIGN/MATERIALS AND METHODS: Venous valves in superficial veins on the dorsal side of the hand of human volunteers were located by palpation and visual inspection. Next, this location was imaged using PAI. RESULTS: In 16 of 21 human volunteers venous valves that were found by palpation could be observed by PAI as local discontinuities in the imaged vessel. From these images, four characteristic features by which venous valves can be recognized in photoacoustic images were identified. CONCLUSIONS: PAI has the potential to be applied in the detection of venous valves.


Subject(s)
Acoustics , Hand/blood supply , Lasers , Ultrasonography/instrumentation , Veins/anatomy & histology , Adolescent , Adult , Child , Equipment Design , Female , Humans , Male , Palpation
6.
Lasers Med Sci ; 21(3): 134-9, 2006 Sep.
Article in English | MEDLINE | ID: mdl-16721626

ABSTRACT

Photoacoustic imaging is a hybrid imaging modality that is based on the detection of acoustic waves generated by absorption of pulsed light by tissue chromophores such as hemoglobin in blood. For this technique, usually large and costly Q-switched Nd:YAG lasers are used. These lasers provide a pulse energy of at least several milliJoules. In search of alternative light sources, we investigated the use of a small and compact pulsed laser diode to image blood vessels. We proved that a pulsed laser diode can be applied for imaging blood vessels in vivo.


Subject(s)
Acoustics , Blood Vessels/diagnostic imaging , Diagnostic Imaging/methods , Lasers , Low-Level Light Therapy/methods , Blood Vessels/anatomy & histology , Humans , Radionuclide Angiography , Spectrum Analysis , Ultrasonography
7.
Lasers Surg Med ; 35(5): 354-62, 2004.
Article in English | MEDLINE | ID: mdl-15611959

ABSTRACT

BACKGROUND AND OBJECTIVES: The ability to correctly visualize the architectural arrangement of microvasculature is valuable to many diverse fields in medicine. In this study, we applied photoacoustics (PA) to obtain high-resolution images of submillimeter blood vessels. STUDY DESIGN/MATERIALS AND METHODS: Short laser pulses are used to generate ultrasound from superficial blood vessels in several animal models. From these ultrasound waves the interior of blood vessels can be reconstructed. RESULTS: We present results from a novel approach based on the PA principle that allows specific in vivo visualization of dermal blood vessels without the use of contrast agents or ionizing radiation. CONCLUSIONS: We show PA images of externalized blood vessels and demonstrate in vivo PA imaging of vasculature through layers of skin varying in thickness.


Subject(s)
Acoustics , Lasers , Mesentery/blood supply , Microcirculation/diagnostic imaging , Skin/blood supply , Animals , Models, Animal , Rabbits , Rats , Ultrasonography
8.
J Biomed Opt ; 9(6): 1327-35, 2004.
Article in English | MEDLINE | ID: mdl-15568955

ABSTRACT

A photoacoustic double-ring sensor, featuring a narrow angular aperture, is developed for laser-induced photoacoustic imaging of blood vessels. An integrated optical fiber enables reflection-mode detection of ultrasonic waves. By using the cross-correlation between the signals detected by the two rings, the angular aperture of the sensor is reduced by a factor of 1.9, from 1.5 to 0.8 deg. Consequently, photoacoustic images could be obtained in a manner analogous to the ultrasound B-scan mode. Next, the cross section of artificial blood vessels is visualized by reconstruction of the absorbed energy distribution. Finally, in vivo imaging and the subsequent reconstruction of the absorbed energy distribution is demonstrated for superficial blood vessels in the human wrist.


Subject(s)
Blood Vessels/diagnostic imaging , Image Interpretation, Computer-Assisted/methods , Lasers , Tomography/instrumentation , Transducers , Ultrasonography/instrumentation , Algorithms , Equipment Design , Equipment Failure Analysis , Humans , Phantoms, Imaging , Reproducibility of Results , Sensitivity and Specificity , Statistics as Topic , Tomography/methods , Ultrasonography/methods
9.
Phys Med Biol ; 49(20): 4745-56, 2004 Oct 21.
Article in English | MEDLINE | ID: mdl-15566172

ABSTRACT

A double-ring sensor was applied in photoacoustic tomographic imaging of artificial blood vessels as well as blood vessels in a rabbit ear. The peak-to-peak time (tau(pp)) of the laser (1064 nm) induced pressure transient was used to estimate the axial vessel diameter. Comparison with the actual vessel diameter showed that the diameter could be approximated by 2ctau(pp), with c the speed of sound in blood. Using this relation, the lateral diameter could also precisely be determined. In vivo imaging and monitoring of changes in vessel diameters was feasible. Finally, acoustic time traces were recorded while flushing a vessel in the rabbit ear with saline, which proved that the main contribution to the laser-induced pressure transient is caused by blood inside the vessel and that the vessel wall gives only a minor contribution.


Subject(s)
Acoustics , Blood Vessels/anatomy & histology , Image Interpretation, Computer-Assisted/methods , Lasers , Tomography/methods , Algorithms , Animals , Ear/anatomy & histology , Ear/blood supply , Feasibility Studies , Phantoms, Imaging , Rabbits , Reproducibility of Results , Sensitivity and Specificity , Tomography/instrumentation , Vibration
10.
Phys Med Biol ; 48(3): 357-70, 2003 Feb 07.
Article in English | MEDLINE | ID: mdl-12608612

ABSTRACT

Materials for solid photoacoustic breast phantoms, based on poly(vinyl alcohol) hydrogels, are presented. Phantoms intended for use in photoacoustics must possess both optical and acoustic properties of tissue. To realize the optical properties of tissue, one approach was to optimize the number of freezing and thawing cycles of aqueous poly(vinyl alcohol) solutions, a procedure which increases the turbidity of the gel while rigidifying it. The second approach concentrated on forming a clear matrix of the rigid poly(vinyl alcohol) gel without any scattering, so that appropriate amounts of optical scatterers could be added at the time of formation, to tune the optical properties as per requirement. The relevant optical and acoustic properties of such samples were measured to be close to the average properties of human breast tissue. Tumour simulating gel samples of suitable absorption coefficient were created by adding appropriate quantities of dye at the time of formation; the samples were then cut into spheres. A breast phantom embedded with such 'tumours' was developed for studying the applicability of photoacoustics in mammography.


Subject(s)
Gels , Phantoms, Imaging , Polyvinyl Alcohol , Spectroscopy, Near-Infrared/instrumentation , Ultrasonography, Mammary/instrumentation , Breast Neoplasms/diagnosis , Breast Neoplasms/diagnostic imaging , Equipment Design , Humans , Mammography/instrumentation , Mammography/methods , Materials Testing/methods , Scattering, Radiation , Spectroscopy, Near-Infrared/methods , Subtraction Technique , Ultrasonography, Mammary/methods
11.
J Am Assoc Gynecol Laparosc ; 8(4): 519-28, 2001 Nov.
Article in English | MEDLINE | ID: mdl-11677330

ABSTRACT

STUDY OBJECTIVE: To evaluate and compare the safety and efficacy of a new method to enter the abdominal cavity at laparoscopy. DESIGN: (Canadian Task Force classification II-2). SETTING: Referral center for reproductive surgery in a teaching hospital affiliated with a university-based residency program. PATIENTS: Twenty representative women of variable body habitus (body mass index 16.5-39 kg/m2). INTERVENTION: Laparoscopy and laparotomy. MEASUREMENTS AND MAIN RESULTS: We measured the thickness of the abdominal wall at the base of the umbilicus and just below its inferior border. We also measured distances traversed by the Veress needle or cannula from skin to peritoneal cavity at both sites when the piercing instrument was directed at 45- or 90-degree angle from the horizontal plane of the abdominal wall. Finally, we measured distances created between parietal peritoneum and underlying viscera when the abdominal wall was lifted manually or with towel clips placed laterally, 2 cm from the umbilicus and at the edges of the intraumbilical incision. Distances created between parietal peritoneum and underlying viscera while lifting the abdominal wall by each of these three techniques were measured with a calibrated probe inserted through the intraumbilical port and observed with a 5-mm laparoscope from the suprapubic port. These distances were measured before and after carbon dioxide insufflation at 15 mm Hg, as well as before and while inserting the cannula through the abdominal wall. Mean +/- SD thickness of the abdominal wall at the base of the umbilicus and lower border of the umbilicus were 1.4 +/- 0.5 and 3.0 +/- 1.1 cm, respectively (p <0.01). Distances traversed by piercing instruments through the abdominal wall at the umbilicus and lower border of the umbilicus when the angle of insertion was 45 degrees were 1.98 +/- 0.76 and 4.24 +/- 1.53 cm, respectively (p <0.01). Distances were significantly greater when the angle of insertion was 45 degrees rather than 90 degrees. Distances between parietal peritoneum and underlying viscera when the abdominal wall was lifted manually with towel clips 2 cm from the umbilicus, or at the edges of the intraumbilical incision were 3.5 +/-1.14, 5.14 +/- 1.04, and 6.8 +/- 0.94 cm, respectively (p <0.01). When force was applied on the abdomen at cannula insertion, these distances were reduced by 2.1 +/- 0.91, 1.03 +/- 0.32, and zero centimeters, respectively (p <0.01). CONCLUSION: Our technique of inserting the cannula perpendicularly through the base of the umbilicus traverses the shortest distance to the abdominal cavity through the least vascular area of the abdominal wall. Lifting the abdominal wall with towel clips placed at the edges of the intraumbilical incision achieves the greatest distance between parietal peritoneum of the abdominal wall and underlying viscera, thus maximizing the margin of safety in protecting peritoneal organs and retroperitoneal vessels from injury.


Subject(s)
Abdomen/surgery , Laparoscopy/methods , Abdomen/anatomy & histology , Abdominal Muscles/anatomy & histology , Body Mass Index , Equipment Design , Equipment Safety , Female , Humans , Laparoscopes , Probability , Prospective Studies , Reference Values , Sampling Studies , Sensitivity and Specificity
12.
Crit Rev Food Sci Nutr ; 29(2): 59-71, 1990.
Article in English | MEDLINE | ID: mdl-2198883

ABSTRACT

Numerous food and beverage products, bulking agents, and pharmaceuticals have pleasant as well as unpleasant bitter-tasting components in their taste profile. In numerous cases, the bitter taste modality is an undesirable trait of the product. Bitter characteristics found in some food systems have been removed or diminished by various known processes, but no universally applicable bitter inhibitor has ever been recognized. Some indications point to a receptor-mediated phenomenon for sweetness and bitterness. Research on sweet compounds has led to knowledge of sweetness inhibitors and could ultimately lead to bitterness inhibitors. To facilitate efforts to rationally design a universal bitter inhibitor or cocktail of such, a review of the bitter taste phenomena and known methods of bitterness reduction and inhibition have been compiled.


Subject(s)
Food Technology/methods , Food-Processing Industry , Perceptual Masking/physiology , Sensory Receptor Cells/physiology , Taste/physiology , Humans , Preservatives, Pharmaceutical , Sweetening Agents