Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
J Appl Physiol (1985) ; 130(4): 1064-1071, 2021 04 01.
Article in English | MEDLINE | ID: mdl-33571055

ABSTRACT

In recent years, the mechanical input impedance of the respiratory system (Zrs) determined using the technique known as oscillometry has been gaining traction as a clinical diagnostic tool to complement conventional spirometry. Nevertheless, despite currently approved oscillometry devices being relatively compact and portable, they are still too heavy and bulky to be used in an ambulatory hands-free setting, mostly because of the mass of the motor and power supply. We therefore explored the possibility of using the subject's own respiratory musculature as the power source for creating flow oscillations at the mouth. We measured reference Zrs in 8 normal volunteers by having them breathe tidally into a piston-driven oscillator powered by an external motor. We fit the measured Zrs to the single-compartment model of the respiratory system characterized by the three parameters resistance (Rrs), elastance (Ers), and inertance (Irs). We then compared these parameter values to those obtained with two commercially available mucus-clearing devices that generate oscillations when expiratory flow drives a flapper valve. The estimates of Rrs agreed mostly within ±1 cmH2O·s·L-1, which is usefully accurate for most clinical needs. Ers and Irs agreed less well because the breath-driven oscillators provided data at essentially a single frequency close to the resonant frequency of the respiratory system. Nevertheless, we conclude that perturbing respiratory airflow and pressure with a breath-driven oscillator has the potential to provide measurements of Zrs, possibly serving as the basis for a lightweight ambulatory oscillometry system.NEW & NOTEWORTHY The technique of oscillometry for measuring the mechanical input impedance of the respiratory system is gaining traction as a clinical diagnostic tool, but the portability of existing commercially available devices is limited by the size and weight of oscillator motors and power supplies. We show that impedance can be measured by oscillations in mouth pressure and flow generated by mucus-clearing devices that are powered by the subject's own respiratory flow.


Subject(s)
Mouth , Respiratory System , Airway Resistance , Electric Impedance , Humans , Oscillometry , Respiratory Function Tests
2.
Front Physiol ; 11: 660, 2020.
Article in English | MEDLINE | ID: mdl-32695013

ABSTRACT

Mechanical ventilation is an essential lifesaving therapy in acute respiratory distress syndrome (ARDS) that may cause ventilator-induced lung injury (VILI) through a positive feedback between altered alveolar mechanics, edema, surfactant inactivation, and injury. Although the biophysical forces that cause VILI are well documented, a knowledge gap remains in the quantitative link between altered parenchymal structure (namely alveolar derecruitment and flooding), pulmonary function, and VILI. This information is essential to developing diagnostic criteria and ventilation strategies to reduce VILI and improve ARDS survival. To address this unmet need, we mechanically ventilated mice to cause VILI. Lung structure was measured at three air inflation pressures using design-based stereology, and the mechanical function of the pulmonary system was measured with the forced oscillation technique. Assessment of the pulmonary surfactant included total surfactant, distribution of phospholipid aggregates, and surface tension lowering activity. VILI-induced changes in the surfactant included reduced surface tension lowering activity in the typically functional fraction of large phospholipid aggregates and a significant increase in the pool of surface-inactive small phospholipid aggregates. The dominant alterations in lung structure at low airway pressures were alveolar collapse and flooding. At higher airway pressures, alveolar collapse was mitigated and the flooded alveoli remained filled with proteinaceous edema. The loss of ventilated alveoli resulted in decreased alveolar gas volume and gas-exchange surface area. These data characterize three alveolar phenotypes in murine VILI: flooded and non-recruitable alveoli, unstable alveoli that derecruit at airway pressures below 5 cmH2O, and alveoli with relatively normal structure and function. The fraction of alveoli with each phenotype is reflected in the proportional changes in pulmonary system elastance at positive end expiratory pressures of 0, 3, and 6 cmH2O.

3.
Sci Rep ; 9(1): 6819, 2019 05 02.
Article in English | MEDLINE | ID: mdl-31048709

ABSTRACT

Intratumoral delivery of cisplatin by endobronchial ultrasound-guided transbronchial needle injection (EBUS-TBNI) has recently emerged as a therapy for treating peribronchial lung cancers. It remains unclear, however, where best to inject drug into a tumor, and at how many sites, so current cisplatin delivery strategies remain empirical. Motivated by the need to put EBUS-TBNI treatment of lung cancer on a more objective footing, we developed a computational model of cisplatin pharmacodynamics following EBUS-TBNI. The model accounts for diffusion of cisplatin within and between the intracellular and extracellular spaces of a tumor, as well as clearance of cisplatin from the tumor via the vasculature and clearance from the body via the kidneys. We matched the tumor model geometry to that determined from a thoracic CT scan of a patient with lung cancer. The model was calibrated by fitting its predictions of cisplatin blood concentration versus time to measurements made up to 2 hrs following EBUS-TBNI of cisplatin into the patient's lung tumor. This gave a value for the systemic volume of distribution for cisplatin of 12.2 L and a rate constant of clearance from the tumor into the systemic compartment of 1.46 × 10-4 s-1. Our model indicates that the minimal dose required to kill all cancerous cells in a lung tumor can be reduced by roughly 3 orders of magnitude if the cisplatin is apportioned between 5 optimally spaced locations throughout the tumor rather than given as a single bolus to the tumor center. Our findings suggest that optimizing the number and location of EBUS-TBNI sites has a dramatic effect on the dose of cisplatin required for efficacious treatment of lung cancer.


Subject(s)
Antineoplastic Agents/administration & dosage , Antineoplastic Agents/pharmacokinetics , Cisplatin/administration & dosage , Cisplatin/pharmacokinetics , Endoscopic Ultrasound-Guided Fine Needle Aspiration , Lung Neoplasms/drug therapy , Algorithms , Cell Survival/drug effects , Disease Management , Dose-Response Relationship, Drug , Endoscopic Ultrasound-Guided Fine Needle Aspiration/methods , Humans , Lung Neoplasms/diagnosis , Models, Theoretical
4.
J Appl Physiol (1985) ; 127(1): 58-70, 2019 07 01.
Article in English | MEDLINE | ID: mdl-31046518

ABSTRACT

Identifying safe ventilation patterns for patients with acute respiratory distress syndrome remains challenging because of the delicate balance between gas exchange and selection of ventilator settings to prevent further ventilator-induced lung injury (VILI). Accordingly, this work seeks to link ventilator settings to graded levels of VILI to identify injury cost functions that predict injury by using a computational model to process pressures and flows measured at the airway opening. Pressure-volume loops were acquired over the course of ~2 h of mechanical ventilation in four different groups of BALB/c mice. A cohort of these animals were subjected to an injurious bronchoalveolar lavage before ventilation. The data were analyzed with a single-compartment model that predicts recruitment/derecruitment and tissue distension at each time step in measured pressure-volume loops. We compared several injury cost functions to markers of VILI-induced blood-gas barrier disruption. Of the cost functions considered, we conclude that mechanical power dissipation and strain heterogeneity are the best at distinguishing between graded levels of injury and are good candidates for forecasting the development of VILI. NEW & NOTEWORTHY This work uses a predictive single-compartment model and injury cost functions to assess graded levels of mechanical ventilator-induced lung injury. The most promising measures include strain heterogeneity and mechanical power dissipation.


Subject(s)
Lung/physiopathology , Ventilator-Induced Lung Injury/physiopathology , Algorithms , Animals , Computer Simulation , Mice , Mice, Inbred BALB C , Positive-Pressure Respiration/methods , Respiration , Respiration, Artificial/methods , Respiratory Distress Syndrome/physiopathology , Tidal Volume/physiology
5.
Respir Physiol Neurobiol ; 255: 22-29, 2018 09.
Article in English | MEDLINE | ID: mdl-29742448

ABSTRACT

Understanding how the mechanisms of ventilator-induced lung injury (VILI), namely atelectrauma and volutrauma, contribute to the failure of the blood-gas barrier and subsequent intrusion of edematous fluid into the airspace is essential for the design of mechanical ventilation strategies that minimize VILI. We ventilated mice with different combinations of tidal volume and positive end-expiratory pressure (PEEP) and linked degradation in lung function measurements to injury of the alveolar epithelium observed via scanning electron microscopy. Ventilating with both high inspiratory plateau pressure and zero PEEP was necessary to cause derangements in lung function as well as visually apparent physical damage to the alveolar epithelium of initially healthy mice. In particular, the epithelial injury was tightly associated with indicators of alveolar collapse. These results support the hypothesis that mechanical damage to the epithelium during VILI is at least partially attributed to atelectrauma-induced damage of alveolar type I epithelial cells.


Subject(s)
Alveolar Epithelial Cells/pathology , Ventilator-Induced Lung Injury/pathology , Ventilator-Induced Lung Injury/physiopathology , Animals , Disease Models, Animal , Female , Linear Models , Mice, Inbred BALB C , Microscopy, Electron, Scanning , Respiration , Respiratory Function Tests , Tidal Volume
6.
PLoS One ; 13(3): e0193934, 2018.
Article in English | MEDLINE | ID: mdl-29590136

ABSTRACT

Acute respiratory distress syndrome (ARDS) is a life-threatening condition for which there are currently no medical therapies other than supportive care involving the application of mechanical ventilation. However, mechanical ventilation itself can worsen ARDS by damaging the alveolocapillary barrier in the lungs. This allows plasma-derived fluid and proteins to leak into the airspaces of the lung where they interfere with the functioning of pulmonary surfactant, which increases the stresses of mechanical ventilation and worsens lung injury. Once such ventilator-induced lung injury (VILI) is underway, managing ARDS and saving the patient becomes increasingly problematic. Maintaining an intact alveolar barrier thus represents a crucial management goal, but the biophysical processes that perforate this barrier remain incompletely understood. To study the dynamics of barrier perforation, we subjected initially normal mice to an injurious ventilation regimen that imposed both volutrauma (overdistension injury) and atelectrauma (injury from repetitive reopening of closed airspaces) on the lung, and observed the rate at which macromolecules of various sizes leaked into the airspaces as a function of the degree of overall injury. Computational modeling applied to our findings suggests that perforations in the alveolocapillary barrier appear and progress according to a rich-get-richer mechanism in which the likelihood of a perforation getting larger increases with the size of the perforation. We suggest that atelectrauma causes the perforations after which volutrauma expands them. This mechanism explains why atelectrauma appears to be essential to the initiation of VILI in a normal lung, and why atelectrauma and volutrauma then act synergistically once VILI is underway.


Subject(s)
Lung/physiopathology , Respiratory Distress Syndrome/complications , Ventilator-Induced Lung Injury/physiopathology , Animals , Lung/metabolism , Mice , Mice, Inbred BALB C , Pulmonary Surfactants/metabolism , Respiration, Artificial/adverse effects , Respiratory Distress Syndrome/metabolism , Ventilator-Induced Lung Injury/metabolism
7.
Front Physiol ; 8: 466, 2017.
Article in English | MEDLINE | ID: mdl-28736528

ABSTRACT

Mechanical ventilation is vital to the management of acute respiratory distress syndrome, but it frequently leads to ventilator-induced lung injury (VILI). Understanding the pathophysiological processes involved in the development of VILI is an essential prerequisite for improving lung-protective ventilation strategies. The goal of this study was to relate the amount and nature of material accumulated in the airspaces to biomarkers of injury and the derecruitment behavior of the lung in VILI. Forty-nine BALB/c mice were mechanically ventilated with combinations of tidal volume and end-expiratory pressures to produce varying degrees of overdistension and atelectasis while lung function was periodically assessed. Total protein, serum protein, and E-Cadherin levels were measured in bronchoalveolar lavage fluid (BALF). Tissue injury was assessed by histological scoring. We found that both high tidal volume and zero positive end-expiratory pressure were necessary to produce significant VILI. Increased BALF protein content was correlated with increased lung derecruitability, elevated peak pressures, and histological evidence of tissue injury. Blood derived molecules were present in the BALF in proportion to histological injury scores and epithelial injury, reflected by E-Cadherin levels in BALF. We conclude that repetitive recruitment is an important factor in the pathogenesis of VILI that exacerbates injury associated with tidal overdistension. Furthermore, the dynamic mechanical behavior of the injured lung provides a means to assess both the degree of tissue injury and the nature and amount of blood-derived fluid and proteins that accumulate in the airspaces.

SELECTION OF CITATIONS
SEARCH DETAIL
...