Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
2.
Cardiology ; 118(2): 101-3, 2011.
Article in English | MEDLINE | ID: mdl-21540590

ABSTRACT

Aortic valve myxoma is an extremely rare cardiac tumour. We describe a 60-year-old woman found to have an aortic valve myxoma and a patent foramen ovale (PFO) presenting as a stroke. In view of the recurrent cerebral ischaemic events, the aortic valve myxoma was surgically removed and the PFO was closed. To the best of our knowledge, this is the first reported case of aortic valve myxoma with a PFO. We also highlight the importance of identifying a possible cardiac source of embolism in a stroke patient and considering this rare tumour as a cause in patients with a cryptogenic stroke.


Subject(s)
Aortic Valve/diagnostic imaging , Heart Valve Diseases/complications , Heart Valve Diseases/diagnostic imaging , Ischemic Attack, Transient/etiology , Myxoma/complications , Myxoma/diagnostic imaging , Aortic Valve/pathology , Female , Foramen Ovale, Patent/complications , Foramen Ovale, Patent/diagnostic imaging , Foramen Ovale, Patent/surgery , Heart Valve Diseases/surgery , Humans , Middle Aged , Myxoma/surgery , Risk Factors , Stroke/etiology , Ultrasonography
4.
Pacing Clin Electrophysiol ; 30(8): 992-7, 2007 Aug.
Article in English | MEDLINE | ID: mdl-17669082

ABSTRACT

BACKGROUND: Implantation and testing of implantable defibrillators (ICDs) using local anesthetic and conscious sedation is widely practiced; however, some centers still use general anesthesia. We assessed safety and patient acceptability for implantation of defibrillators using local anesthetic and conscious sedation. METHODS: The records of 500 consecutive device implants from two UK cardiac centers implanted under local anesthetic and conscious sedation from January 1996 to December 2004 were reviewed. Procedure time, left ventricular ejection fraction (LVEF) sedative dosage (midazolam), analgesic dosage (fentanyl or diamorphine), requirement for drug reversal, and respiratory support were recorded. Patient acceptability of the procedure was also assessed. RESULTS: Of 500 implants examined, 387 were ICDs, 88 were biventricular ICDs, and 25 were generator changes. Patients with biventricular-ICDs had significantly longer (mean +/- SD) procedure times 129.7 +/- 7.6 minutes versus 63.3 +/- 32.3 minutes; P < 0.0001 and lower LVEF 24.4 +/- 8.4% versus 35.7 +/- 15.4%; P < 0.0001. There were no differences in the doses (mean +/- SD) of midazolam 8.9 +/- 3.5 mg versus 8.0 +/- 3.1 mg; P = NS, diamorphine 4.3 +/- 2.0 mg versus 3.8 +/- 1.7 mg; P = NS or fentanyl 94.4 +/- 53.7 mcg versus 92.2 +/- 48.6 mcg; P = NS, between the two groups. There were no deaths or tracheal intubations in either group. Acceptability was available for 373 of 500 (75%) patients, 41 of 373 (11%) described "discomfort," but from these 41 patients only 14 of 373 (3.8%) declined a second procedure under the same conditions. CONCLUSIONS: Implantation of defibrillators under local anesthetic and sedation is safe and acceptable to patients. General anesthesia is no longer routinely required for implantation of defibrillators.


Subject(s)
Anesthesia, Local , Cardiac Surgical Procedures/methods , Conscious Sedation , Defibrillators, Implantable , Anesthesia, General , Equipment Safety , Female , Humans , Male , Middle Aged , Patient Satisfaction , Postoperative Complications , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...