Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
PLoS One ; 19(6): e0305166, 2024.
Article in English | MEDLINE | ID: mdl-38861543

ABSTRACT

CNN has demonstrated remarkable performance in EEG signal detection, yet it still faces limitations in terms of global perception. Additionally, due to individual differences in EEG signals, the generalization ability of epilepsy detection models is week. To address this issue, this paper presents a cross-patient epilepsy detection method utilizing a multi-head self-attention mechanism. This method first utilizes Short-Time Fourier Transform (STFT) to transform the original EEG signals into time-frequency features, then models local information using Convolutional Neural Network (CNN), subsequently captures global dependency relationships between features using the multi-head self-attention mechanism of Transformer, and finally performs epilepsy detection using these features. Meanwhile, this model employs a light multi-head attention mechanism module with an alternating structure, which can comprehensively extract multi-scale features while significantly reducing computational costs. Experimental results on the CHB-MIT dataset show that the proposed model achieves accuracy, sensitivity, specificity, F1 score, and AUC of 92.89%, 96.17%, 92.99%, 94.41%, and 96.77%, respectively. Compared to the existing methods, the method proposed in this paper obtains better performance along with better generalization.


Subject(s)
Electroencephalography , Epilepsy , Neural Networks, Computer , Humans , Epilepsy/diagnosis , Epilepsy/physiopathology , Electroencephalography/methods , Fourier Analysis , Signal Processing, Computer-Assisted , Algorithms
2.
Front Neurol ; 15: 1378076, 2024.
Article in English | MEDLINE | ID: mdl-38633533

ABSTRACT

Introduction: In recent years, the use of EEG signals for seizure detection has gained widespread academic attention. Aiming at the problem of overfitting deep learning models due to the small number of EEG signal data during epilepsy detection, this paper proposes an epilepsy detection method that combines data augmentation and deep learning. Methods: First, the Adversarial and Mixup Data Augmentation (AMDA) method is used to realize the data augmentation, which effectively enriches the number of training samples. To further improve the classification accuracy and robustness of epilepsy detection, this paper proposes a one-dimensional convolutional neural network and gated recurrent unit (AM-1D CNN-GRU) network model based on attention mechanism for epilepsy detection. Results and discussion: The experimental results show that the performance of epilepsy detection achieved by using augmented data is significantly improved, and the accuracy, sensitivity, and area under the subject's working characteristic curve are up to 96.06, 95.48%, and 0.9637, respectively. Compared with the non-augmented data, all indicators are increased by more than 6.2%. Meanwhile, the detection performance was significantly improved compared with other epilepsy detection methods. The results of this research can provide a reference for the clinical application of epilepsy detection.

3.
Appl Bionics Biomech ; 2022: 8311249, 2022.
Article in English | MEDLINE | ID: mdl-35706511

ABSTRACT

Epilepsy detection based on electroencephalogram (EEG) is important for the diagnosis and treatment of epilepsy. The existing feature extraction method not only consumes a lot of time but also leads to epilepsy information loss because of nonideal denoising. Therefore, the paper proposes to use noisy EEG signals to detect epilepsy. The original EEG signal is divided into normal signal and abnormal signal by Riemann potato, and the epilepsy detection model is established based on the normal signal and abnormal signal, respectively. Finally, the 2 detection results are combined as a final result. The detection performance of 94.84%, 83.03% sensitivity, and 97.67% specificity is achieved. The experimental results show that the original noisy signal which is separated by the Riemann potato can have high epilepsy detection performance.

4.
Comput Intell Neurosci ; 2022: 6180441, 2022.
Article in English | MEDLINE | ID: mdl-35087582

ABSTRACT

Epilepsy detection based on electroencephalogram (EEG) signal is of great significance to diagnosis and treatment of epilepsy. The denoised EEG signal is adopted by most traditional epilepsy detection methods. But due to nonideal denoising ability, the loss of local information and residual noise will occur, resulting in detection performance degradation. To solve the problem, the paper proposed an epilepsy detection method in noisy environment. Although epileptic signals and nonepileptic signals have some discrimination, they need to overcome the interference of noise. Hence, the improved sample entropy and phase synchronization indexes of corresponding 2 intrinsic mode functions (IMFs) caused by variational mode decomposition (VMD) are proposed as features, which can reduce the impact of noise on detection performance. The experimental results show that the accuracy, sensitivity, and specificity are 91.78%, 91.27%, and 93.61%, respectively. It can be used as an auxiliary method for clinical treatment of epilepsy.


Subject(s)
Epilepsy , Signal Processing, Computer-Assisted , Algorithms , Electroencephalography , Entropy , Epilepsy/diagnosis , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...