Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
PLoS One ; 8(6): e67082, 2013.
Article in English | MEDLINE | ID: mdl-23825624

ABSTRACT

Cronobacter spp. is an emerging pathogen that causes meningitis, sepsis, bacteremia, and necrotizing enterocolitis in neonates and children. The present study developed an assay integrating real-time PCR and high resolution melting (HRM) analysis targeting the OmpA gene for the specific detection and rapid identification of Cronobacter spp. (formerly Enterobacter sakazakii) in powdered infant formula. Eleven Cronobacter field isolates and 25 reference strains were examined using one pair of primers, having the accuracy of 100% in reference to conventional methods. The assay was proved to be highly sensitive with a detection limit of 10(2) CFU/ml without pre-enrichment, and highly concordant (100%) when compared with ISO-IDF 22964 in 89 actual samples. The method performed for Cronobacter spp. detection was less than 24 h, drastically shortened, compared to several days using standard culturing method, it is probe-free and reduces a risk of PCR carryover. Moreover, all Cronobacter strains examined in this study were genotyped into two species according to their HRM profiles. The established method should provide a molecular tool for direct detection and simultaneous genotyping of Cronobacter spp. in powdered infant formula.


Subject(s)
Cronobacter/genetics , Cronobacter/isolation & purification , Food Contamination/analysis , Genotyping Techniques/methods , Infant Formula , Real-Time Polymerase Chain Reaction , Transition Temperature , Bacterial Outer Membrane Proteins/genetics , Base Sequence , DNA, Bacterial/chemistry , DNA, Bacterial/genetics , Humans , Infant , Limit of Detection , Nucleic Acid Denaturation , Powders , Time Factors
2.
Bing Du Xue Bao ; 29(5): 488-94, 2013 Sep.
Article in Chinese | MEDLINE | ID: mdl-24386836

ABSTRACT

H5 subtype avian influenza (AIV-H5) is a major causative agent of animalloimia a rapid and sensitive molecular biological diagnosis is crucial to the control program of AIV-H5. AIV-H5 real-time fluorescent reverse transcription loop-mediated isothermal amplification (qRT-LAMP) was established by means of heat treatment of the samples. The sensitivity, specificity and repeatability of this method were assessed and the performance of Calcein,SYBR Green I,HNB,SYTO 81 in colorimetric detection was comparatively analyzed to screen the optimum dye. The results showed the sensitivity of this method was 100 times higher than that of standard real-time fluorescent RT-PCR, and the detection limit was one copy of the gene per reaction. This method had no cross-reactivity with other common avian respiratory tract infectious disease-related pathogens such as IBV and NDV. The present study suggested Calcein was the optimum dye. Small-scale tests suggested this method was reliable for survey monitoring of AIV-H5 on the spot, indicating its potential applications in field investigation.


Subject(s)
Hemagglutinin Glycoproteins, Influenza Virus/genetics , Influenza A Virus, H5N1 Subtype/isolation & purification , Influenza in Birds/virology , Poultry Diseases/virology , Reverse Transcriptase Polymerase Chain Reaction/methods , Animals , Chickens , Influenza A Virus, H5N1 Subtype/genetics , Influenza in Birds/diagnosis , Poultry Diseases/diagnosis , Reverse Transcriptase Polymerase Chain Reaction/instrumentation , Sensitivity and Specificity
3.
Virol Sin ; 27(2): 120-31, 2012 Apr.
Article in English | MEDLINE | ID: mdl-22492003

ABSTRACT

This study developed a multiplex RT-PCR integrated with luminex technology to rapidly subtype simultaneously multiple influenza viruses. Primers and probes were designed to amplify NS and M genes of influenza A viruses HA gene of H1, H3, H5, H7, H9 subtypes, and NA gene of the N1 and N2 subtypes. Universal super primers were introduced to establish a multiplex RT-PCR (GM RT-PCR). It included three stages of RT-PCR amplification, and then the RT-PCR products were further tested by LiquiChip probe, combined to give an influenza virus (IV) rapid high throughput subtyping test, designated as GMPLex. The IV GMPLex rapid high throughput subtyping test presents the following features: high throughput, able to determine the subtypes of 9 target genes in H1, H3, H5, H7, H9, N1, and N2 subtypes of the influenza A virus at one time; rapid, completing the influenza subtyping within 6 hours; high specificity, ensured the specificity of the different subtypes by using two nested degenerate primers and one probe, no cross reaction occurring between the subtypes, no non-specific reactions with other pathogens and high sensitivity. When used separately to detect the product of single GM RT-PCR for single H5 or N1 gene, the GMPLex test showed a sensitivity of 10⁻5(= 280ELD50) forboth tests and the Luminex qualitative ratio results were 3.08 and 3.12, respectively. When used to detect the product of GM RT-PCR for H5N1 strain at the same time, both showed a sensitivity of 10⁻4(=2800 ELD50). The GMPLex rapid high throughput subtyping test can satisfy the needs of influenza rapid testing.


Subject(s)
High-Throughput Nucleotide Sequencing/methods , Influenza A virus/isolation & purification , Influenza in Birds/virology , Multiplex Polymerase Chain Reaction/methods , Animals , Birds , DNA Primers/genetics , High-Throughput Nucleotide Sequencing/instrumentation , Influenza A virus/classification , Influenza A virus/genetics , Influenza in Birds/diagnosis , RNA, Viral/genetics , Real-Time Polymerase Chain Reaction/methods
4.
Immunol Invest ; 40(1): 14-28, 2011.
Article in English | MEDLINE | ID: mdl-20809697

ABSTRACT

A new competitive bead immunoassay (CBIA) based on Luminex technology for detecting clenbuterol in urine was reported. The carboxylated fluorescent beads were directly coated with clenbuterol derivatives without carrier protein spacer. Clenbuterol antibody was biotinylated, which was used for clenbuterol detection in combination with the functionalized bead and streptavidin-phycoerythrin (SAPE). The effects of spacer on the CBIA method were investigated. The results indicated that the presence of small molecular spacer between bead and hapten improved the assay sensitivity and the hydrophilic spacer (glycine) was better than the hydrophobic spacer (m-aminobenzoic acid) for this CBIA method. The study affirms the importance of the judicious choice of hapten derivatives in the CBIA method for detecting small molecule drug based on Luminex technology. The method could be used for clenbuterol detection in livestock urine and possible for the simultaneous detection of multiple veterinary drugs.


Subject(s)
Clenbuterol/urine , Flow Cytometry/methods , Fluorescent Antibody Technique/methods , 4-Aminobenzoic Acid , Animals , Biotinylation , Clenbuterol/immunology , Glycine , Immunoassay/methods , Microspheres , Phycoerythrin , Streptavidin , Swine/urine
SELECTION OF CITATIONS
SEARCH DETAIL
...