Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
JMIR Mhealth Uhealth ; 6(12): e200, 2018 Dec 21.
Article in English | MEDLINE | ID: mdl-30578215

ABSTRACT

BACKGROUND: Telecoaching approaches can enhance physical activity (PA) in patients with chronic obstructive pulmonary disease (COPD). However, their effectiveness is likely to be influenced by intervention-specific characteristics. OBJECTIVE: This study aimed to assess the acceptability, actual usage, and feasibility of a complex PA telecoaching intervention from both patient and coach perspectives and link these to the effectiveness of the intervention. METHODS: We conducted a mixed-methods study based on the completers of the intervention group (N=159) included in an (effective) 12-week PA telecoaching intervention. This semiautomated telecoaching intervention consisted of a step counter and a smartphone app. Data from a project-tailored questionnaire (quantitative data) were combined with data from patient interviews and a coach focus group (qualitative data) to investigate patient and coach acceptability, actual usage, and feasibility of the intervention. The degree of actual usage of the smartphone and step counter was also derived from app data. Both actual usage and perception of feasibility were linked to objectively measured change in PA. RESULTS: The intervention was well accepted and perceived as feasible by all coaches present in the focus group as well by patients, with 89.3% (142/159) of patients indicating that they enjoyed taking part. Only a minority of patients (8.2%; 13/159) reported that they found it difficult to use the smartphone. Actual usage of the step counter was excellent, with patients wearing it for a median (25th-75th percentiles) of 6.3 (5.8-6.8) days per week, which did not change over time (P=.98). The smartphone interface was used less frequently and actual usage of all daily tasks decreased significantly over time (P<.001). Patients needing more contact time had a smaller increase in PA, with mean (SD) of +193 (SD 2375) steps per day, +907 (SD 2306) steps per day, and +1489 (SD 2310) steps per day in high, medium, and low contact time groups, respectively; P for-trend=.01. The overall actual usage of the different components of the intervention was not associated with change in step count in the total group (P=.63). CONCLUSIONS: The 12-week semiautomated PA telecoaching intervention was well accepted and feasible for patients with COPD and their coaches. The actual usage of the step counter was excellent, whereas actual usage of the smartphone tasks was lower and decreased over time. Patients who required more contact experienced less PA benefits. TRIAL REGISTRATION: ClinicalTrials.gov NCT02158065; http://clinicaltrials.gov/ct2/show/NCT02158065 (Archived by WebCite at http://www.webcitation.org/73bsaudy9).

2.
Int J Chron Obstruct Pulmon Dis ; 12: 1221-1231, 2017.
Article in English | MEDLINE | ID: mdl-28458534

ABSTRACT

Telehealth programs to promote early identification and timely self-management of acute exacerbations of chronic obstructive pulmonary diseases (AECOPDs) have yielded disappointing results, in part, because parameters monitored (symptoms, pulse oximetry, and spirometry) are weak predictors of exacerbations. PURPOSE: Breathing rate (BR) rises during AECOPD and may be a promising predictor. Devices suitable for home use to measure BR have recently become available, but their accuracy, acceptability, and ability to detect changes in people with COPD is not known. PATIENTS AND METHODS: We compared five BR monitors, which used different monitoring technologies, with a gold standard (Oxycon Mobile®; CareFusion®, a subsidiary of Becton Dickinson, San Diego, CA, USA). The monitors were validated in 21 stable COPD patients during a 57-min "activities of daily living protocol" in a laboratory setting. The two best performing monitors were then tested in a 14-day trial in a home setting in 23 stable COPD patients to determine patient acceptability and reliability of signal. Acceptability was explored in qualitative interviews. The better performing monitor was then given to 18 patients recruited during an AECOPD who wore the monitor to observe BR during the recovery phase of an AECOPD. RESULTS: While two monitors demonstrated acceptable accuracy compared with the gold standard, some participants found them intrusive particularly when ill with an exacerbation, limiting their potential utility in acute situations. A reduction in resting BR during the recovery from an AECOPD was observed in some, but not in all participants and there was considerable day-to-day individual variation. CONCLUSION: Resting BR shows some promise in identifying exacerbations; however, further prospective study to assess this is required.


Subject(s)
Lung/physiopathology , Pulmonary Disease, Chronic Obstructive/diagnosis , Respiratory Function Tests/instrumentation , Respiratory Mechanics , Telemedicine/instrumentation , Aged , Aged, 80 and over , Disease Progression , Equipment Design , Exercise , Feasibility Studies , Female , Heart Rate , Humans , Interviews as Topic , Male , Middle Aged , Patient Satisfaction , Predictive Value of Tests , Pulmonary Disease, Chronic Obstructive/physiopathology , Qualitative Research , Reproducibility of Results , Respiratory Function Tests/standards , Telemedicine/standards
3.
PLoS One ; 11(12): e0168321, 2016.
Article in English | MEDLINE | ID: mdl-27973556

ABSTRACT

INTRODUCTION: The Bland-Altman limits of agreement method is widely used to assess how well the measurements produced by two raters, devices or systems agree with each other. However, mixed effects versions of the method which take into account multiple sources of variability are less well described in the literature. We address the practical challenges of applying mixed effects limits of agreement to the comparison of several devices to measure respiratory rate in patients with chronic obstructive pulmonary disease (COPD). METHODS: Respiratory rate was measured in 21 people with a range of severity of COPD. Participants were asked to perform eleven different activities representative of daily life during a laboratory-based standardised protocol of 57 minutes. A mixed effects limits of agreement method was used to assess the agreement of five commercially available monitors (Camera, Photoplethysmography (PPG), Impedance, Accelerometer, and Chest-band) with the current gold standard device for measuring respiratory rate. RESULTS: Results produced using mixed effects limits of agreement were compared to results from a fixed effects method based on analysis of variance (ANOVA) and were found to be similar. The Accelerometer and Chest-band devices produced the narrowest limits of agreement (-8.63 to 4.27 and -9.99 to 6.80 respectively) with mean bias -2.18 and -1.60 breaths per minute. These devices also had the lowest within-participant and overall standard deviations (3.23 and 3.29 for Accelerometer and 4.17 and 4.28 for Chest-band respectively). CONCLUSIONS: The mixed effects limits of agreement analysis enabled us to answer the question of which devices showed the strongest agreement with the gold standard device with respect to measuring respiratory rates. In particular, the estimated within-participant and overall standard deviations of the differences, which are easily obtainable from the mixed effects model results, gave a clear indication that the Accelerometer and Chest-band devices performed best.


Subject(s)
Pulmonary Disease, Chronic Obstructive/physiopathology , Pulmonary Disease, Chronic Obstructive/therapy , Pulmonary Medicine/instrumentation , Respiratory Rate , Accelerometry , Analysis of Variance , Humans , Photoplethysmography/methods , Reproducibility of Results , Respiration , Severity of Illness Index
4.
Eur Respir J ; 48(1): 69-81, 2016 07.
Article in English | MEDLINE | ID: mdl-27103381

ABSTRACT

The broad range of interventions to increase physical activity (PA) in patients with chronic obstructive pulmonary disease (COPD) has not been systematically assessed. We aimed to perform a systematic review of the interventional studies that have assessed PA as an outcome in patients with COPD.A systematic search in five different databases (Medline, Embase, PsycINFO, CINAHL and Web of Science) was performed in March 2015. Two independent reviewers analysed the studies against the inclusion criteria (COPD defined by spirometry; prospective, randomised/nonrandomised studies, cohort and experimental studies with interventions using PA as an outcome), extracted the data and assessed the quality of evidence.60 studies were included. Seven intervention groups were identified. PA counselling increased PA levels in COPD, especially when combined with coaching. 13 studies showed positive effects of pulmonary rehabilitation (PR) on PA, while seven studies showed no changes. All three PR programmes >12 weeks in duration increased PA. Overall, the quality of evidence was graded as very low.Interventions focusing specifically on increasing PA, and longer PR programmes, may have greater impacts on PA in COPD. Well-designed clinical trials with objective assessment of PA in COPD patients are needed.


Subject(s)
Exercise , Pulmonary Disease, Chronic Obstructive/physiopathology , Pulmonary Disease, Chronic Obstructive/rehabilitation , Counseling , Exercise Tolerance , Humans , Program Evaluation , Randomized Controlled Trials as Topic , Spirometry
SELECTION OF CITATIONS
SEARCH DETAIL
...