Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Nucl Med Biol ; 114-115: 29-33, 2022.
Article in English | MEDLINE | ID: mdl-36088874

ABSTRACT

This report is a summary of the first SRS-Africa meeting that was held virtually on the 15th of October 2021, to gain information on the status of radiopharmaceutical sciences in Africa. Registration data included information on participants' qualifications and field of work. An independent survey performed in Africa prior to the meeting elicited details of available staff in different countries, facilities and equipment, radionuclides and radiopharmaceuticals used, research undertaken and difficulties experienced. We present here a brief overview of this meeting's topics of discussion, including ongoing research, gaps and challenges, and local opportunities.


Subject(s)
Radiopharmaceuticals , Humans , Africa
2.
EJNMMI Radiopharm Chem ; 5(1): 9, 2020 Apr 10.
Article in English | MEDLINE | ID: mdl-32277373

ABSTRACT

INTRODUCTION: The radiochemical purity (RCP) of technetium-99m labelled radiopharmaceuticals (RP) is important to ensure optimal scintigraphic image quality. In low-income settings, it may not be possible to use compendial analytical methods or expensive equipment for radiochemical purity analysis. All radiochemical analysis methods should however be validated against compendial or otherwise proven methods. To ensure the efficacy of RP prepared at Yaoundé General Hospital (YGH) Cameroon, this study cross-validated a cost-effective routine chromatographic method using a simple survey meter technique. A GMP-compliant method used at the University Medical Center Groningen (UMCG), the Netherlands was used as the comparator. METHODS: Sestamibi, HMDP and DMSA kits currently used at YGH were reconstituted at UMCG with about 2000 MBq of freshly eluted sodium pertechnetate as described by the manufacturer, and spiked with eluate of the same generator to obtain a range of impurity concentrations. Samples of technetium-99m RP were spotted on 1 × 10 cm iTLC-SG strips and developed in appropriate mobile phases. Each strip was first scanned on the chromatogram-scanner used at the UMCG (standard method), and immediately thereafter the strip was cut in two pieces and radioactivity from each portion was counted with a small survey meter from YGH. The percentage RCP for each TLC strip was calculated using both counting methods. Internationally recommended validation parameters and acceptance criteria were used. Student's paired t-test or ANOVA were used with 'no significant difference' designated at a 95% confidence-interval (P ≥ 0.05). Linearity of the survey meter was determined for Tc-99m. Readings obtained with the survey meter were also plotted against the scanner results. RESULTS AND DISCUSSION: The proposed method proved to be accurate (CV of mean RCP < 2), precise (RSD < 2%), linear (slope close to 1, r2 ≥ 0.99) within the RCP range of approximately 80% to 100%, and robust (P > 0.05). LOD and LOQ were determined for the survey meter. Specificity depends on chemical separation. As we were validating the suitability of a method to quantify radioactivity, specificity was not included in the validation parameters. CONCLUSION: The proposed method compared well with the standard method and is suitable as a reliable low cost method for limited resource settings.

3.
Eur J Nucl Med ; 18(5): 363-5, 1991.
Article in English | MEDLINE | ID: mdl-1936045

ABSTRACT

The amount of radioactivity excreted in breast milk following the administration of technetium 99m hexakismethoxyisobutylisonitrile (99mTc-MIBI) to a patient referred for cold spot myocardial scintigraphy was determined. During the first 24 h after administration, only 41.2 kBq 99mTc (0.0084% of the injected dose) was excreted in 448 ml milk with the highest concentration of 0.49 kBq/ml in the first sample. The images obtained show a high concentration of 99mTc-MIBI in the lactating breasts contrary to the very small percentage excreted in the milk. Comparison with various recommendations regarding nursing after administration of radiopharmaceuticals seems to indicate that the administration of 99mTc-MIBI does not necessitate an interruption of breast-feeding.


Subject(s)
Breast Feeding , Milk, Human/chemistry , Nitriles/pharmacokinetics , Organotechnetium Compounds/pharmacokinetics , Puerperal Disorders/diagnostic imaging , Adult , Female , Humans , Myocardial Infarction/diagnostic imaging , Radionuclide Imaging , Technetium Tc 99m Sestamibi
SELECTION OF CITATIONS