Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 125
Filter
1.
J Cardiovasc Electrophysiol ; 35(6): 1185-1195, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38591763

ABSTRACT

INTRODUCTION: Biventricular pacing (BiVp) improves outcomes in systolic heart failure patients with electrical dyssynchrony. BiVp is delivered from epicardial left ventricular (LV) and endocardial right ventricular (RV) electrodes. Acute electrical activation changes with different LV-RV stimulation offsets can help guide individually optimized BiVp programming. We sought to study the BiVp ventricular activation with different LV-RV offsets and compare with 12-lead ECG. METHODS: In five patients with BiVp (63 ± 17-year-old, 80% male, LV ejection fraction 27 ± 6%), we evaluated acute ventricular epicardial activation, varying LV-RV offsets in 20 ms increments from -40 to 80 ms, using electrocardiographic imaging (ECGI) to obtain absolute ventricular electrical uncoupling (VEUabs, absolute difference in average LV and average RV activation time) and total activation time (TAT). For each patient, we calculated the correlation between ECGI and corresponding ECG (3D-QRS-area and QRS duration) with different LV-RV offsets. RESULTS: The LV-RV offset to attain minimum VEUabs in individual patients ranged 20-60 ms. In all patients, a larger LV-RV offset was required to achieve minimum VEUabs (36 ± 17 ms) or 3D-QRS-area (40 ± 14 ms) than that for minimum TAT (-4 ± 9 ms) or QRS duration (-8 ± 11 ms). In individual patients, 3D-QRS-area correlated with VEUabs (r 0.65 ± 0.24) and QRS duration correlated with TAT (r 0.95 ± 0.02). Minimum VEUabs and minimum 3D-QRS-area were obtained by LV-RV offset within 20 ms of each other in all five patients. CONCLUSIONS: LV-RV electrical uncoupling, as assessed by ECGI, can be minimized by optimizing LV-RV stimulation offset. 3D-QRS-area is a surrogate to identify LV-RV offset that minimizes LV-RV uncoupling.


Subject(s)
Action Potentials , Cardiac Resynchronization Therapy , Electrocardiography , Predictive Value of Tests , Ventricular Function, Left , Ventricular Function, Right , Humans , Male , Pilot Projects , Female , Middle Aged , Aged , Treatment Outcome , Heart Rate , Time Factors , Stroke Volume , Heart Ventricles/physiopathology , Heart Ventricles/diagnostic imaging
3.
J Am Coll Cardiol ; 83(11): 1042-1055, 2024 Mar 19.
Article in English | MEDLINE | ID: mdl-38385929

ABSTRACT

BACKGROUND: Ventricular arrhythmia in hypertrophic cardiomyopathy (HCM) relates to adverse structural change and genetic status. Cardiovascular magnetic resonance (CMR)-guided electrocardiographic imaging (ECGI) noninvasively maps cardiac structural and electrophysiological (EP) properties. OBJECTIVES: The purpose of this study was to establish whether in subclinical HCM (genotype [G]+ left ventricular hypertrophy [LVH]-), ECGI detects early EP abnormality, and in overt HCM, whether the EP substrate relates to genetic status (G+/G-LVH+) and structural phenotype. METHODS: This was a prospective 211-participant CMR-ECGI multicenter study of 70 G+LVH-, 104 LVH+ (51 G+/53 G-), and 37 healthy volunteers (HVs). Local activation time (AT), corrected repolarization time, corrected activation-recovery interval, spatial gradients (GAT/GRTc), and signal fractionation were derived from 1,000 epicardial sites per participant. Maximal wall thickness and scar burden were derived from CMR. A support vector machine was built to discriminate G+LVH- from HV and low-risk HCM from those with intermediate/high-risk score or nonsustained ventricular tachycardia. RESULTS: Compared with HV, subclinical HCM showed mean AT prolongation (P = 0.008) even with normal 12-lead electrocardiograms (ECGs) (P = 0.009), and repolarization was more spatially heterogenous (GRTc: P = 0.005) (23% had normal ECGs). Corrected activation-recovery interval was prolonged in overt vs subclinical HCM (P < 0.001). Mean AT was associated with maximal wall thickness; spatial conduction heterogeneity (GAT) and fractionation were associated with scar (all P < 0.05), and G+LVH+ had more fractionation than G-LVH+ (P = 0.002). The support vector machine discriminated subclinical HCM from HV (10-fold cross-validation accuracy 80% [95% CI: 73%-85%]) and identified patients at higher risk of sudden cardiac death (accuracy 82% [95% CI: 78%-86%]). CONCLUSIONS: In the absence of LVH or 12-lead ECG abnormalities, HCM sarcomere gene mutation carriers express an aberrant EP phenotype detected by ECGI. In overt HCM, abnormalities occur more severely with adverse structural change and positive genetic status.


Subject(s)
Cardiomyopathy, Hypertrophic , Cicatrix , Humans , Prospective Studies , Cicatrix/pathology , Magnetic Resonance Imaging, Cine , Cardiomyopathy, Hypertrophic/diagnostic imaging , Cardiomyopathy, Hypertrophic/genetics , Electrocardiography , Hypertrophy, Left Ventricular/diagnosis , Magnetic Resonance Imaging
4.
J Cardiovasc Magn Reson ; 25(1): 73, 2023 Dec 04.
Article in English | MEDLINE | ID: mdl-38044439

ABSTRACT

BACKGROUND: Electrocardiographic imaging (ECGI) generates electrophysiological (EP) biomarkers while cardiovascular magnetic resonance (CMR) imaging provides data about myocardial structure, function and tissue substrate. Combining this information in one examination is desirable but requires an affordable, reusable, and high-throughput solution. We therefore developed the CMR-ECGI vest and carried out this technical development study to assess its feasibility and repeatability in vivo. METHODS: CMR was prospectively performed at 3T on participants after collecting surface potentials using the locally designed and fabricated 256-lead ECGI vest. Epicardial maps were reconstructed to generate local EP parameters such as activation time (AT), repolarization time (RT) and activation recovery intervals (ARI). 20 intra- and inter-observer and 8 scan re-scan repeatability tests. RESULTS: 77 participants were recruited: 27 young healthy volunteers (HV, 38.9 ± 8.5 years, 35% male) and 50 older persons (77.0 ± 0.1 years, 52% male). CMR-ECGI was achieved in all participants using the same reusable, washable vest without complications. Intra- and inter-observer variability was low (correlation coefficients [rs] across unipolar electrograms = 0.99 and 0.98 respectively) and scan re-scan repeatability was high (rs between 0.81 and 0.93). Compared to young HV, older persons had significantly longer RT (296.8 vs 289.3 ms, p = 0.002), ARI (249.8 vs 235.1 ms, p = 0.002) and local gradients of AT, RT and ARI (0.40 vs 0.34 ms/mm, p = 0,01; 0.92 vs 0.77 ms/mm, p = 0.03; and 1.12 vs 0.92 ms/mm, p = 0.01 respectively). CONCLUSION: Our high-throughput CMR-ECGI solution is feasible and shows good reproducibility in younger and older participants. This new technology is now scalable for high throughput research to provide novel insights into arrhythmogenesis and potentially pave the way for more personalised risk stratification. CLINICAL TRIAL REGISTRATION: Title: Multimorbidity Life-Course Approach to Myocardial Health-A Cardiac Sub-Study of the MRC National Survey of Health and Development (NSHD) (MyoFit46). National Clinical Trials (NCT) number: NCT05455125. URL: https://clinicaltrials.gov/ct2/show/NCT05455125?term=MyoFit&draw=2&rank=1.


Subject(s)
Heart , Magnetic Resonance Imaging , Aged , Female , Humans , Male , Feasibility Studies , Magnetic Resonance Imaging/methods , Magnetic Resonance Spectroscopy , Predictive Value of Tests , Reproducibility of Results , Adult , Middle Aged
5.
Front Cardiovasc Med ; 9: 1052195, 2022.
Article in English | MEDLINE | ID: mdl-36518686

ABSTRACT

Introduction: Catheter ablation of persistent AF has not been consistently successful in terminating AF or preventing arrhythmia recurrences. Non-invasive Electrocardiographic Imaging (ECGI) can help to understand recurrences by mapping the mechanisms of pre-ablation AF and comparing them with the patterns of recurrent arrhythmias in the same patient. Methods: Seventeen persistent AF patients underwent ECGI before their first catheter ablation. Time-domain activation maps and phase progression maps were obtained on the bi-atrial epicardium. Location of arrhythmogenic drivers were annotated on the bi-atrial anatomy. Activation and phase movies were examined to understand the wavefront dynamics during AF. Eight patients recurred within 12 months of ablation and underwent a follow-up ECGI. Driver locations and movies were compared for pre- and post-ablation AF. Results: A total of 243 focal drivers were mapped during pre-ablation AF. 62% of the drivers were mapped in the left atrium (LA). The pulmonary vein region harbored most of the drivers (43%). 35% of the drivers were mapped in the right atrium (RA). 59% (10/17) and 53% (9/17) of patients had repetitive sources in the left pulmonary veins (LPV) and left atrial appendage (LAA), and the lower half of RA, respectively. All patients had focal drivers. 29% (5/17) of patients had macro-reentry waves. 24% (4/17) of patients had rotors. Activation patterns during persistent AF varied from single macro-reentry to complex activity with multiple simultaneous wavefronts in both atria, resulting in frequent wave collisions. A total of 76 focal driver activities were mapped in 7/8 patients during recurrence. 59% of the post-ablation AF drivers were mapped in the LA. The pulmonary vein region harbored 50% of total drivers. 39% of sources were mapped in the RA. AF complexity remained similar post-ablation. 58% (44/76) of pre-ablation sources persisted during recurrence. 38% (3/8) of patients had macro-reentry and one patient had rotors. Conclusion: ECGI provides patient-specific information on mechanisms of persistent AF and recurrent arrhythmia. More than half pre-ablation sources repeated during post-ablation recurrence. This study provides direct evidence for drivers that persist days and months after the ablation procedure. Patient-tailored bi-atrial ablation is needed to successfully target persistent AF and prevent recurrence. ECGI can potentially predict recurrence and assist in choice of therapy.

6.
BMC Cardiovasc Disord ; 22(1): 140, 2022 04 01.
Article in English | MEDLINE | ID: mdl-35365075

ABSTRACT

BACKGROUND: The life course accumulation of overt and subclinical myocardial dysfunction contributes to older age mortality, frailty, disability and loss of independence. The Medical Research Council National Survey of Health and Development (NSHD) is the world's longest running continued surveillance birth cohort providing a unique opportunity to understand life course determinants of myocardial dysfunction as part of MyoFit46-the cardiac sub-study of the NSHD. METHODS: We aim to recruit 550 NSHD participants of approximately 75 years+ to undertake high-density surface electrocardiographic imaging (ECGI) and stress perfusion cardiovascular magnetic resonance (CMR). Through comprehensive myocardial tissue characterization and 4-dimensional flow we hope to better understand the burden of clinical and subclinical cardiovascular disease. Supercomputers will be used to combine the multi-scale ECGI and CMR datasets per participant. Rarely available, prospectively collected whole-of-life data on exposures, traditional risk factors and multimorbidity will be studied to identify risk trajectories, critical change periods, mediators and cumulative impacts on the myocardium. DISCUSSION: By combining well curated, prospectively acquired longitudinal data of the NSHD with novel CMR-ECGI data and sharing these results and associated pipelines with the CMR community, MyoFit46 seeks to transform our understanding of how early, mid and later-life risk factor trajectories interact to determine the state of cardiovascular health in older age. TRIAL REGISTRATION: Prospectively registered on ClinicalTrials.gov with trial ID: 19/LO/1774 Multimorbidity Life-Course Approach to Myocardial Health- A Cardiac Sub-Study of the MCRC National Survey of Health and Development (NSHD).


Subject(s)
Cardiovascular Diseases , Magnetic Resonance Imaging , Aged , Cardiovascular Diseases/diagnostic imaging , Cardiovascular Diseases/epidemiology , Health Surveys , Heart , Humans , Myocardium
7.
Philos Trans A Math Phys Eng Sci ; 379(2212): 20200257, 2021 Dec 13.
Article in English | MEDLINE | ID: mdl-34689630

ABSTRACT

Cardiac magnetic resonance (CMR) imaging is a valuable modality in the diagnosis and characterization of cardiovascular diseases, since it can identify abnormalities in structure and function of the myocardium non-invasively and without the need for ionizing radiation. However, in clinical practice, it is commonly acquired as a collection of separated and independent 2D image planes, which limits its accuracy in 3D analysis. This paper presents a completely automated pipeline for generating patient-specific 3D biventricular heart models from cine magnetic resonance (MR) slices. Our pipeline automatically selects the relevant cine MR images, segments them using a deep learning-based method to extract the heart contours, and aligns the contours in 3D space correcting possible misalignments due to breathing or subject motion first using the intensity and contours information from the cine data and next with the help of a statistical shape model. Finally, the sparse 3D representation of the contours is used to generate a smooth 3D biventricular mesh. The computational pipeline is applied and evaluated in a CMR dataset of 20 healthy subjects. Our results show an average reduction of misalignment artefacts from 1.82 ± 1.60 mm to 0.72 ± 0.73 mm over 20 subjects, in terms of distance from the final reconstructed mesh. The high-resolution 3D biventricular meshes obtained with our computational pipeline are used for simulations of electrical activation patterns, showing agreement with non-invasive electrocardiographic imaging. The automatic methodologies presented here for patient-specific MR imaging-based 3D biventricular representations contribute to the efficient realization of precision medicine, enabling the enhanced interpretability of clinical data, the digital twin vision through patient-specific image-based modelling and simulation, and augmented reality applications. This article is part of the theme issue 'Advanced computation in cardiovascular physiology: new challenges and opportunities'.


Subject(s)
Imaging, Three-Dimensional , Magnetic Resonance Imaging, Cine , Heart/diagnostic imaging , Humans , Magnetic Resonance Imaging , Magnetic Resonance Spectroscopy
8.
9.
Circ Res ; 126(8): 965-967, 2020 04 10.
Article in English | MEDLINE | ID: mdl-32271685
10.
J Atr Fibrillation ; 13(2): 2304, 2020 Aug.
Article in English | MEDLINE | ID: mdl-34950292

ABSTRACT

OBJECTIVE: Patients with severe mitral regurgitation commonly develop atrial fibrillation. The precise mechanisms of this relationship remain unknown. The objective of this study was to apply noninvasive electrocardiographic imaging of the atria during sinus rhythm to identify changes in atrial electrophysiology that may contribute to development of atrial fibrillation in patients with severe mitral regurgitation referred for mitral valve surgery. METHODS: Twenty subjects (9 atrial fibrillation and mitral regurgitation, 11 mitral regurgitation alone) underwent electrocardiographic imaging. Biatrial electrophysiology was imaged with activation maps in sinus rhythm. The reconstructed unipolar electrograms were analyzed for voltage amplitude, number of deflections and conduction heterogeneity. In subjects with mitral regurgitation, left atrial biopsies were obtained at the time of surgery. Results: Subjects with history of atrial fibrillation demonstrated prolonged left atrial conduction times (110±25 ms vs. mitral regurgitation alone (85±21), p=0.025); right atrial conduction times were unaffected. Variable patterns of conduction slowing were imaged in the left atria of most subjects, but those with prior history of atrial fibrillation had more complex patterns of conduction slowing or unidirectional block. The presence of atrial fibrillation was not associated with the extent of fibrosis in atrial biopsies. CONCLUSIONS: Detailed changes in sinus rhythm atrial electrophysiology can be imaged noninvasively and can be used to assess the impact and evolution of atrial fibrillation on atrial conduction properties in patients with mitral regurgitation. If replicated in larger studies, electrocardiographic imaging may identify patients with mitral regurgitation at risk for atrial fibrillation and could be used to guide treatment strategies.

12.
J Am Heart Assoc ; 8(18): e012097, 2019 09 17.
Article in English | MEDLINE | ID: mdl-31496332

ABSTRACT

Background The relationship between structural pathology and electrophysiological substrate in cardiac amyloidosis is unclear. Differences between light-chain (AL) and transthyretin (ATTR) cardiac amyloidosis may have prognostic implications. Methods and Results ECG imaging and cardiac magnetic resonance studies were conducted in 21 cardiac amyloidosis patients (11 AL and 10 ATTR). Healthy volunteers were included as controls. With respect to ATTR, AL patients had lower amyloid volume (51.0/37.7 versus 73.7/16.4 mL, P=0.04), lower myocardial cell volume (42.6/19.1 versus 58.5/17.2 mL, P=0.021), and higher T1 (1172/64 versus 1109/80 ms, P=0.022) and T2 (53.4/2.9 versus 50.0/3.1 ms, P=0.003). ECG imaging revealed differences between cardiac amyloidosis and control patients in virtually all conduction-repolarization parameters. With respect to ATTR, AL patients had lower epicardial signal amplitude (1.07/0.46 versus 1.83/1.26 mV, P=0.026), greater epicardial signal fractionation (P=0.019), and slightly higher dispersion of repolarization (187.6/65 versus 158.3/40 ms, P=0.062). No significant difference between AL and ATTR patients was found using the standard 12-lead ECG. T1 correlated with epicardial signal amplitude (cc=-0.78), and extracellular volume with epicardial signal fractionation (cc=0.48) and repolarization time (cc=0.43). Univariate models based on single features from both cardiac magnetic resonance and ECG imaging classified AL and ATTR patients with an accuracy of 70% to 80%. Conclusions In this exploratory study cardiac amyloidosis was associated with ventricular conduction and repolarization abnormalities, which were more pronounced in AL than in ATTR. Combined ECG imaging-cardiac magnetic resonance analysis supports the hypothesis that additional mechanisms beyond infiltration may contribute to myocardial damage in AL amyloidosis. Further studies are needed to assess the clinical impact of this approach.


Subject(s)
Amyloid Neuropathies, Familial/diagnostic imaging , Cardiac Imaging Techniques/methods , Cardiomyopathies/diagnostic imaging , Immunoglobulin Light-chain Amyloidosis/diagnostic imaging , Adult , Aged , Aged, 80 and over , Amyloid Neuropathies, Familial/physiopathology , Amyloidosis/diagnostic imaging , Amyloidosis/physiopathology , Cardiomyopathies/physiopathology , Case-Control Studies , Electrocardiography , Female , Humans , Immunoglobulin Light-chain Amyloidosis/physiopathology , Magnetic Resonance Imaging , Male , Middle Aged , Pericardium/diagnostic imaging , Pericardium/physiopathology
13.
Heart Rhythm ; 16(6): e50-e51, 2019 06.
Article in English | MEDLINE | ID: mdl-30735790
14.
Circulation ; 139(3): 313-321, 2019 01 15.
Article in English | MEDLINE | ID: mdl-30586734

ABSTRACT

BACKGROUND: Case studies have suggested the efficacy of catheter-free, electrophysiology-guided noninvasive cardiac radioablation for ventricular tachycardia (VT) using stereotactic body radiation therapy, although prospective data are lacking. METHODS: We conducted a prospective phase I/II trial of noninvasive cardiac radioablation in adults with treatment-refractory episodes of VT or cardiomyopathy related to premature ventricular contractions (PVCs). Arrhythmogenic scar regions were targeted by combining noninvasive anatomic and electric cardiac imaging with a standard stereotactic body radiation therapy workflow followed by delivery of a single fraction of 25 Gy to the target. The primary safety end point was treatment-related serious adverse events in the first 90 days. The primary efficacy end point was any reduction in VT episodes (tracked by indwelling implantable cardioverter defibrillators) or any reduction in PVC burden (as measured by a 24-hour Holter monitor) comparing the 6 months before and after treatment (with a 6-week blanking window after treatment). Health-related quality of life was assessed using the Short Form-36 questionnaire. RESULTS: Nineteen patients were enrolled (17 for VT, 2 for PVC cardiomyopathy). Median noninvasive ablation time was 15.3 minutes (range, 5.4-32.3). In the first 90 days, 2/19 patients (10.5%) developed a treatment-related serious adverse event. The median number of VT episodes was reduced from 119 (range, 4-292) to 3 (range, 0-31; P<0.001). Reduction was observed for both implantable cardioverter defibrillator shocks and antitachycardia pacing. VT episodes or PVC burden were reduced in 17/18 evaluable patients (94%). The frequency of VT episodes or PVC burden was reduced by 75% in 89% of patients. Overall survival was 89% at 6 months and 72% at 12 months. Use of dual antiarrhythmic medications decreased from 59% to 12% ( P=0.008). Quality of life improved in 5 of 9 Short Form-36 domains at 6 months. CONCLUSIONS: Noninvasive electrophysiology-guided cardiac radioablation is associated with markedly reduced ventricular arrhythmia burden with modest short-term risks, reduction in antiarrhythmic drug use, and improvement in quality of life. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov/ . Unique identifier: NCT02919618.


Subject(s)
Action Potentials , Electrophysiologic Techniques, Cardiac , Heart Ventricles/radiation effects , Radiofrequency Ablation/methods , Radiosurgery/methods , Tachycardia, Ventricular/radiotherapy , Ventricular Premature Complexes/radiotherapy , Aged , Aged, 80 and over , Anti-Arrhythmia Agents/therapeutic use , Female , Heart Ventricles/physiopathology , Humans , Male , Middle Aged , Missouri , Predictive Value of Tests , Prospective Studies , Quality of Life , Radiofrequency Ablation/adverse effects , Radiosurgery/adverse effects , Recurrence , Risk Factors , Surveys and Questionnaires , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/physiopathology , Time Factors , Treatment Outcome , Ventricular Premature Complexes/diagnosis , Ventricular Premature Complexes/physiopathology
15.
J Mol Cell Cardiol ; 124: 35-44, 2018 11.
Article in English | MEDLINE | ID: mdl-30292722

ABSTRACT

Dynamic conformational changes of ion channel proteins during activation gating determine their function as carriers of current. The relationship between these molecular movements and channel function over the physiological timescale of the action potential (AP) has not been fully established due to limitations of existing techniques. We constructed a library of possible cardiac IKs protein conformations and applied a combination of protein segmentation and energy linearization to study this relationship computationally. Simulations reproduced the effects of the beta-subunit (KCNE1) on the alpha-subunit (KCNQ1) dynamics and function, observed in experiments. Mechanistically, KCNE1 increased the probability of "visiting" conducting pore conformations on activation trajectories, thereby increasing IKs current. KCNE1 slowed IKs activation by impeding the voltage sensor (VS) movement and reducing its coupling to pore opening. Conformational changes along activation trajectories determined that the S4-S5 linker (S4S5L) plays an important role in these modulatory effects by KCNE1. Integration of these molecular structure-based IKs dynamics into a model of human cardiac ventricular myocyte, revealed that KCNQ1-KCNE1 interaction is essential for normal AP repolarization.


Subject(s)
Ion Channel Gating , Molecular Conformation , Molecular Dynamics Simulation , Potassium Channels/chemistry , Potassium Channels/metabolism , Protein Subunits/chemistry , Protein Subunits/metabolism , Action Potentials , Myocytes, Cardiac/metabolism , Potassium Channels, Voltage-Gated/chemistry , Potassium Channels, Voltage-Gated/metabolism , Protein Conformation , Quantitative Structure-Activity Relationship
16.
Biophys J ; 114(11): 2584-2594, 2018 06 05.
Article in English | MEDLINE | ID: mdl-29874609

ABSTRACT

Relating ion channel (iCh) structural dynamics to physiological function remains a challenge. Current experimental and computational techniques have limited ability to explore this relationship in atomistic detail over physiological timescales. A framework associating iCh structure to function is necessary for elucidating normal and disease mechanisms. We formulated a modeling schema that overcomes the limitations of current methods through applications of artificial intelligence machine learning. Using this approach, we studied molecular processes that underlie human IKs voltage-mediated gating. IKs malfunction underlies many debilitating and life-threatening diseases. Molecular components of IKs that underlie its electrophysiological function include KCNQ1 (a pore-forming tetramer) and KCNE1 (an auxiliary subunit). Simulations, using the IKs structure-function model, reproduced experimentally recorded saturation of gating-charge displacement at positive membrane voltages, two-step voltage sensor (VS) movement shown by fluorescence, iCh gating statistics, and current-voltage relationship. Mechanistic insights include the following: 1) pore energy profile determines iCh subconductance; 2) the entire protein structure, not limited to the pore, contributes to pore energy and channel subconductance; 3) interactions with KCNE1 result in two distinct VS movements, causing gating-charge saturation at positive membrane voltages and current activation delay; and 4) flexible coupling between VS and pore permits pore opening at lower VS positions, resulting in sequential gating. The new modeling approach is applicable to atomistic scale studies of other proteins on timescales of physiological function.


Subject(s)
Models, Molecular , Potassium Channels, Voltage-Gated/chemistry , Potassium Channels, Voltage-Gated/metabolism , Humans , Ion Channel Gating , Movement , Protein Conformation , Thermodynamics
18.
J Med Biol Eng ; 37(5): 780-789, 2017 Oct.
Article in English | MEDLINE | ID: mdl-29213224

ABSTRACT

Gain-of-function mutations in the pore-forming subunit of IKs channels, KCNQ1, lead to short QT syndrome (SQTS) and lethal arrhythmias. However, how mutant IKs channels cause SQTS and the possibility of IKs-specific pharmacological treatment remain unclear. V141M KCNQ1 is a SQTS associated mutation. We studied its effect on IKs gating properties and changes in the action potentials (AP) of human ventricular myocytes. Xenopus oocytes were used to study the gating mechanisms of expressed V141M KCNQ1/KCNE1 channels. Computational models were used to simulate human APs in endocardial, mid-myocardial, and epicardial ventricular myocytes with and without ß-adrenergic stimulation. V141M KCNQ1 caused a gain-of-function in IKs characterized by increased current density, faster activation, and slower deactivation leading to IKs accumulation. V141M KCNQ1 also caused a leftward shift of the conductance-voltage curve compared to wild type (WT) IKs (V1/2 = 33.6 ± 4.0 mV for WT, and 24.0 ± 1.3 mV for heterozygous V141M). A Markov model of heterozygous V141M mutant IKs was developed and incorporated into the O'Hara-Rudy model. Compared to the WT, AP simulations demonstrated marked rate-dependent shortening of AP duration (APD) for V141M, predicting a SQTS phenotype. Transmural electrical heterogeneity was enhanced in heterozygous V141M AP simulations, especially under ß-adrenergic stimulation. Computational simulations identified specific IK1 blockade as a beneficial pharmacologic target for reducing the transmural APD heterogeneity associated with V141M KCNQ1 mutation. V141M KCNQ1 mutation shortens ventricular APs and enhances transmural APD heterogeneity under ß-adrenergic stimulation. Computational simulations identified IK1 blockers as a potential antiarrhythmic drug of choice for SQTS.

19.
N Engl J Med ; 377(24): 2325-2336, 2017 12 14.
Article in English | MEDLINE | ID: mdl-29236642

ABSTRACT

BACKGROUND: Recent advances have enabled noninvasive mapping of cardiac arrhythmias with electrocardiographic imaging and noninvasive delivery of precise ablative radiation with stereotactic body radiation therapy (SBRT). We combined these techniques to perform catheter-free, electrophysiology-guided, noninvasive cardiac radioablation for ventricular tachycardia. METHODS: We targeted arrhythmogenic scar regions by combining anatomical imaging with noninvasive electrocardiographic imaging during ventricular tachycardia that was induced by means of an implantable cardioverter-defibrillator (ICD). SBRT simulation, planning, and treatments were performed with the use of standard techniques. Patients were treated with a single fraction of 25 Gy while awake. Efficacy was assessed by counting episodes of ventricular tachycardia, as recorded by ICDs. Safety was assessed by means of serial cardiac and thoracic imaging. RESULTS: From April through November 2015, five patients with high-risk, refractory ventricular tachycardia underwent treatment. The mean noninvasive ablation time was 14 minutes (range, 11 to 18). During the 3 months before treatment, the patients had a combined history of 6577 episodes of ventricular tachycardia. During a 6-week postablation "blanking period" (when arrhythmias may occur owing to postablation inflammation), there were 680 episodes of ventricular tachycardia. After the 6-week blanking period, there were 4 episodes of ventricular tachycardia over the next 46 patient-months, for a reduction from baseline of 99.9%. A reduction in episodes of ventricular tachycardia occurred in all five patients. The mean left ventricular ejection fraction did not decrease with treatment. At 3 months, adjacent lung showed opacities consistent with mild inflammatory changes, which had resolved by 1 year. CONCLUSIONS: In five patients with refractory ventricular tachycardia, noninvasive treatment with electrophysiology-guided cardiac radioablation markedly reduced the burden of ventricular tachycardia. (Funded by Barnes-Jewish Hospital Foundation and others.).


Subject(s)
Catheter Ablation/methods , Radiosurgery , Tachycardia, Ventricular/radiotherapy , Aged , Aged, 80 and over , Cicatrix/complications , Cicatrix/pathology , Defibrillators, Implantable , Electrocardiography , Electrophysiologic Techniques, Cardiac , Fatal Outcome , Female , Heart Ventricles/diagnostic imaging , Heart Ventricles/pathology , Heart Ventricles/physiopathology , Humans , Male , Middle Aged , Myocardium/pathology , Radiosurgery/adverse effects , Radiosurgery/methods , Stroke/etiology , Stroke Volume , Tachycardia, Ventricular/etiology , Tachycardia, Ventricular/physiopathology , Tomography, X-Ray Computed
20.
JACC Clin Electrophysiol ; 3(8): 894-904, 2017 08.
Article in English | MEDLINE | ID: mdl-29130071

ABSTRACT

Background: The early repolarization (ER) pattern is a common ECG finding. Recent studies established a definitive clinical association between ER and fatal ventricular arrhythmias. However, the arrhythmogenic substrate of ER in the intact human heart has not been characterized. Objectives: To map the epicardial electrophysiological (EP) substrate in ER syndrome patients using noninvasive Electrocardiographic Imaging (ECGI), and to characterize substrate properties that support arrhythmogenicity. Methods: Twenty-nine ER syndrome patients were enrolled, 17 of which had a malignant syndrome. Characteristics of the abnormal EP substrate were analyzed using data recorded during sinus rhythm. The EP mapping data were analyzed for electrogram morphology, conduction and repolarization. Seven normal subjects provided control data. Results: The abnormal EP substrate in ER syndrome patients has the following properties: (1) Abnormal epicardial electrograms characterized by presence of J-waves in localized regions; (2) Absence of conduction abnormalities, including delayed activation, conduction block, or fractionated electrograms; (3) Marked abbreviation of ventricular repolarization in areas with J-waves. The action potential duration (APD) was significantly shorter than normal (196±19 vs. 235±21 ms, p<0.05). Shortening of APD occurred heterogeneously, leading to steep repolarization gradients compared to normal control (45±17 vs.7±5 ms/cm, p<0.05). Premature ventricular contractions (PVCs) were recorded in 2 patients. The PVC sites of origin were closely related to the abnormal EP substrate with J-waves and steep repolarization gradients. Conclusions: Early Repolarization is associated with steep repolarization gradients caused by localized shortening of APD. Results suggest association of PVC initiation sites with areas of repolarization abnormalities. Conduction abnormalities were not observed.


Subject(s)
Arrhythmias, Cardiac/physiopathology , Epicardial Mapping , Adult , Aged , Arrhythmias, Cardiac/etiology , Case-Control Studies , Electrocardiography , Female , Heart/physiopathology , Humans , Male , Middle Aged , Syndrome , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...