Ann Biomed Eng ; 51(9): 1950-1964, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37436564

ABSTRACT

The endothelium in the coronary arteries is subject to wall shear stress and vessel wall strain, which influences the biology of the arterial wall. This study presents vessel-specific fluid-structure interaction (FSI) models of three coronary arteries, using directly measured experimental geometries and boundary conditions. FSI models are used to provide a more physiologically complete representation of vessel biomechanics, and have been extended to include coronary bending to investigate its effect on shear and strain. FSI both without- and with-bending resulted in significant changes in all computed shear stress metrics compared to CFD (p = 0.0001). Inclusion of bending within the FSI model produced highly significant changes in Time Averaged Wall Shear Stress (TAWSS) + 9.8% LAD, + 8.8% LCx, - 2.0% RCA; Oscillatory Shear Index (OSI) + 208% LAD, 0% LCx, + 2600% RCA; and transverse wall Shear Stress (tSS) + 180% LAD, + 150% LCx and + 200% RCA (all p < 0.0001). Vessel wall strain was homogenous in all directions without-bending but became highly anisotropic under bending. Changes in median cyclic strain magnitude were seen for all three vessels in every direction. Changes shown in the magnitude and distribution of shear stress and wall strain suggest that bending should be considered on a vessel-specific basis in analyses of coronary artery biomechanics.


Subject(s)
Coronary Vessels , Models, Cardiovascular , Biomechanical Phenomena , Coronary Vessels/physiology , Computer Simulation , Heart , Stress, Mechanical , Hemodynamics
2.
J Biomed Opt ; 24(5): 1-11, 2019 05.
Article in English | MEDLINE | ID: mdl-31087833

ABSTRACT

In Fourier-domain optical coherence tomography (FD-OCT), proper signal sampling and dispersion compensation are essential steps to achieve optimal axial resolution. These calibration steps can be performed through numerical signal processing, but require calibration information about the system that may require lengthy and complex measurement protocols. We report a highly robust calibration procedure that can simultaneously determine correction vectors for nonlinear wavenumber sampling and dispersion compensation. The proposed method requires only two simple mirror measurements and no prior knowledge about the system's illumination source or detection scheme. This method applies to both spectral domain and swept-source OCT systems. Furthermore, it may be implemented as a low-cost fail-safe to validate the proper function of calibration hardware such as k-clocks. We demonstrate the method's simple implementation, effectiveness, and robustness on both types of OCT systems.


Subject(s)
Tomography, Optical Coherence/instrumentation , Tomography, Optical Coherence/methods , Algorithms , Calibration , Fourier Analysis , Image Processing, Computer-Assisted , Interferometry , Nonlinear Dynamics , Signal Processing, Computer-Assisted
SELECTION OF CITATIONS
SEARCH DETAIL
...