Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 63
Filter
1.
Plant Physiol ; 195(2): 1152-1160, 2024 May 31.
Article in English | MEDLINE | ID: mdl-38124468

ABSTRACT

C-REPEAT BINDING FACTORS (CBFs) are highly conserved plant transcription factors that promote cold tolerance. In Arabidopsis (Arabidopsis thaliana), three CBFs (CBF1 to CBF3) play a critical role in cold acclimation, and the expression of their corresponding genes is rapidly and transiently induced during this adaptive response. Cold induction of CBFs has been extensively studied and shown to be tightly controlled, yet the molecular mechanisms that restrict the expression of each CBF after their induction during cold acclimation are poorly understood. Here, we present genetic and molecular evidence that the decline in the induction of CBF3 during cold acclimation is epigenetically regulated through the Polycomb Repressive Complex (PRC) 2. We show that this complex promotes the deposition of the repressive mark H3K27me3 at the coding region of CBF3, silencing its expression. Our results indicate that the cold-inducible long noncoding RNA SVALKA is essential for this regulation by recruiting PRC2 to CBF3. These findings unveil a SVALKA-PRC2 regulatory module that ensures the precise timing of CBF3 induction during cold acclimation and the correct development of this adaptive response.


Subject(s)
Acclimatization , Arabidopsis Proteins , Arabidopsis , Cold Temperature , Gene Expression Regulation, Plant , Polycomb Repressive Complex 2 , Arabidopsis/genetics , Arabidopsis/physiology , Arabidopsis/metabolism , Arabidopsis Proteins/genetics , Arabidopsis Proteins/metabolism , Acclimatization/genetics , Polycomb Repressive Complex 2/metabolism , Polycomb Repressive Complex 2/genetics , RNA, Long Noncoding/genetics , RNA, Long Noncoding/metabolism , Histones/metabolism , Transcription Factors/metabolism , Transcription Factors/genetics
2.
J Clin Med ; 12(4)2023 Feb 06.
Article in English | MEDLINE | ID: mdl-36835805

ABSTRACT

BACKGROUND AND PURPOSE: Provisional prostheses in restorations over several implants with immediate loading in completely edentulous patients increase the risk of frequent structural fractures. An analysis was performed of the resistance to fracture of prosthetic structures with cantilevers using graphene-doped polymethyl methacrylate (PMMA) resins and CAD-CAM technology. METHODS: A master model was produced with four implants measuring 4 mm in diameter and spaced 3 mm apart, over which 44 specimens representing three-unit fixed partial prostheses with a cantilever measuring 11 mm were placed. These structures were cemented over titanium abutments using dual cure resin cement. Twenty-two of the 44 units were manufactured from machined PMMA discs, and 22 were manufactured from PMMA doped with graphene oxide nanoparticles (PMMA-G). All of the samples were tested in a chewing simulator with a load of 80 N until fracture or 240,000 load applications. RESULTS: The mean number of load applications required for temporary restoration until the fracture was 155,455 in the PMMA-G group versus 51,136 in the PMMA group. CONCLUSIONS: Resistance to fracture under cyclic loading was three times greater in the PMMA-G group than in the PMMA group.

3.
J Prosthet Dent ; 129(5): 703-709, 2023 May.
Article in English | MEDLINE | ID: mdl-34702586

ABSTRACT

STATEMENT OF PROBLEM: One of the most frequent complications in participants with fixed partial dentures (FPDs) is the apical migration of the gingival margin, which may be associated with factors such as fit, gingival margin location, or tooth preparation type. The prevalence of the complication in participants restored with FPDs prepared by using the biologically oriented preparation technique (BOPT) is unclear. PURPOSE: The purpose of this prospective clinical trial was to evaluate the clinical and biologic outcomes of FPDs on teeth prepared by using the BOPT, over a 6-year follow-up period. MATERIAL AND METHODS: Tooth-supported zirconia FPDs in the anterior region prepared by using the BOPT were evaluated. Each participant was monitored annually for 6 years by evaluating plaque index, probing depth, vestibular gingival thickness, and gingival margin stability. Biologic and/or mechanical complications were also recorded. Patient satisfaction was measured by using a visual analog scale (VAS). RESULTS: A total of 25 FPDs supported by 70 teeth in 24 participants were analyzed. Low plaque index values and stable probing depths were observed, whereas the gingival index was 0 for most of the teeth. Teeth treated by using the BOPT presented significant increase in gingival thickness, and the gingival margin was found to be stable in 100% of the treatments. FPD survival was 100%. CONCLUSION: Tooth supporting FPDs prepared by using the BOPT presented good periodontal health and gingival margin stability, without recession and with a 100% survival rate during a 6-year follow-up.


Subject(s)
Biological Products , Tooth , Humans , Prospective Studies , Denture Design , Denture, Partial, Fixed , Follow-Up Studies , Dental Restoration Failure
4.
J Clin Med ; 11(21)2022 Nov 04.
Article in English | MEDLINE | ID: mdl-36362777

ABSTRACT

BACKGROUND: This systematic review and meta-analysis aimed to evaluate the wear of the antagonist tooth in ceramic restorations. MATERIAL AND METHODS: This study was carried out based on Preferred Reporting Items for Systematic Review and Meta-analysis (PRISMA) recommendations; it was also registered in PROSPERO (register number: CRD42022316252). Three databases were consulted in the literature search, Embase, Scopus, and Web of Science. The citation searching was conducted by two researchers independently. The clinical studies that evaluated wear in antagonist teeth concerning ceramic restoration were included. Twelve articles were selected after eliminating duplicates ones and applying the inclusion criteria, and two were chosen through citation. Fourteen articles were considered for the qualitative and quantitative analysis (meta-regression and meta-analysis). RESULTS: The mean linear wear of the antagonist tooth in relation to feldspathic was 8.914 µm, for lithium disilicate it was 0.018 µm, and for zirconia it was 0.257 µm. The mean volumetric wear of the antagonist tooth in relation to feldspathic was 0.273 mm3, for hybrid ceramic it was 0.030 mm3, for lithium disilicate it was 0.018 mm3, and for zirconia it was 0.014 mm3. The mean natural tooth wear was 0.7974 µm per month. Tooth wear caused by zirconia at six months was 31.755 µm, at 12 months it was 24.648 µm, and at 24 months it was 20.662 µm. CONCLUSIONS: Feldspathic produces greater wear of the antagonist tooth from ceramic restorations linearly and volumetrically. In addition, zirconia generates the least wear that will decrease over time, and it will be equal to or less than the natural wear in the tooth.

5.
J Clin Med ; 11(14)2022 Jul 15.
Article in English | MEDLINE | ID: mdl-35887880

ABSTRACT

OBJECTIVE: The main objective of this study aimed to evaluate the response to treatment in implants with peri-implantitis regarding the presence or absence of keratinized mucosa. MATERIALS AND METHODS: One hundred implants with peri-implantitis were treated non-surgically at the Prosthodontics and Occlusion Teaching Unit of the University of Valencia. Records were registered at day zero (recession, bleeding on probing, suppuration, probing depth, bone loss and plaque index), at 1, 3 and 6 months. RESULTS: In both groups, a slight increase in recession and disappearance of suppuration took place, and no bone loss was observed during the following 6 months. However, after an initial reduction, probing depth, bleeding on probing and plaque index increased again in the group without keratinized mucosa (KM). CONCLUSIONS: Implants with KM presented better results after non-surgical treatment as well as in their medium-term evolution, although it would be advisable to increase the number of samples in order to achieve greater scientific evidence and standardization in the treatment protocol. CLINICAL RELEVANCE: The role of keratinized mucosa in the development of peri-implantitis has been mentioned in many publications, but less has been emphasized regarding its influence on the success of the treatment of this pathology. The presence of keratinized mucosa has been found to play a key role in the evolution of the non-surgical treatment of peri-implantitis. The amount of keratinized mucosa should be considered in the treatment of peri-implantitis, as well as when planning connective tissue grafts accompanying the decontamination of implants in the absence of keratinized mucosa.

6.
World J Cardiol ; 14(4): 239-249, 2022 Apr 26.
Article in English | MEDLINE | ID: mdl-35582470

ABSTRACT

BACKGROUND: The estimation of left ventricular ejection fraction (LVEF) by 2D echocardiography (2D-ECHO) is the most used tool to assess LV systolic function (LVSF). Global longitudinal strain (GLS) has recently been suggested as a superior method for several evaluations. This study explored the association and prevalence of LV systolic dysfunction (LVSD) by using these methods in patients with end-stage renal disease (ESRD) and severe hyperparathyroidism (SHPTH); both associated with cardiovascular events (CEs). AIM: To evaluate the myocardial function in patients with ESRD and SHPTH by using the GLS and LVEF measured through conventional 2D-ECHO. METHODS: In 62 patients with ESRD and SHPTH, asymptomatic, and without a history of CEs, LVSF was evaluated by 2D-ECHO, obtaining the EF, by the Simpson biplane method, and GLS by speckle tracking. RESULTS: The total patients with ESRD had a preserved LVEF (> 50%) but abnormal GLS (< 13.55%). Additionally, multivariate analysis showed an independent association of GLS and serum parathyroid hormone (PTH), LV mass index, and hemoglobin. Also, PTH was independently associated with lateral e' wave and tricuspid regurgitation velocity. CONCLUSION: In patients with SHPTH linked to ESRD, the use of GLS by 2D-ECHO is a more sensitive tool than LVEF for detecting LVSD.

7.
J Clin Med ; 11(6)2022 Mar 21.
Article in English | MEDLINE | ID: mdl-35330067

ABSTRACT

OBJECTIVE: The aim of the systematic review and meta-analysis carried out was to evaluate the effects of changing the prosthetic platform on peri-implant tissue after 1 year of prosthetic loading. MATERIAL AND METHODS: In November 2020, an electronic search was carried out in PubMed, EMBASE, Web of Science, and Scopus databases with the aim of obtaining all the randomized clinical trials that had been published in the preceding 10 years comparing the effects on the peri-implant tissue of implants with a prosthetic platform change and implants with a conventional platform for at least 1 year after prosthetic loading. Randomized model meta-analyses of the selected studies were performed to compare the results of the two implant groups in terms of vertical maintenance of bone level and increased probing depth. RESULTS: Nine studies were included, summing up a total of 475 implants with prosthetic platform exchange and 462 implants with a conventional platform. Implants with prosthetic platform exchange had less peri-implant bone loss than implants with a conventional platform (mean difference of 0.255 mm, statistically significant) but suffered a greater increase in probing depth (mean difference of 0.082 mm, not statistically significant). However, the probing depth from One Study Remove revealed a statistically significant increase of 0.190 mm in the prosthetic platform exchange group compared to the conventional platform group. CONCLUSION: Implants with platform switching suffer less peri-implant bone loss after 1 year of loading than implants with a conventional platform. Further long-term studies are required to observe how these differences vary over time.

8.
J Prosthet Dent ; 127(6): 846-851, 2022 Jun.
Article in English | MEDLINE | ID: mdl-33495043

ABSTRACT

STATEMENT OF PROBLEM: Anterior veneered zirconia partial fixed dental prostheses (FDPs) have substituted for metal-ceramic to improve esthetics and biocompatibility. However, the material is susceptible to aging or hydrothermal degradation and to chipping of the feldspathic veneer. Whether these susceptibilities limit the clinical performance of anterior veneered zirconia FPDs is unclear. PURPOSE: The purpose of this prospective clinical study was to analyze the mechanical and biologic behavior of zirconia partial FDPs in the anterior region over a 12-year follow-up period. MATERIAL AND METHODS: Twenty-seven 3- to 6-unit FDPs fabricated from zirconia veneered with feldspathic porcelain were placed in the anterior region and examined clinically at 1 month, 6 months, and then annually for 12 years, recording mechanical and biologic outcomes. Raw complication rates and time-to-event Kaplan-Meier analysis was conducted and compared as per the partial fixed dental prosthesis type. RESULTS: Five FDPs had biologic complications (3 with secondary caries, 1 with periapical pathology, 1 with periodontal disease) and 9 had mechanical complications (7 with chipping and 2 with decementation). Chipping was the most prevalent complication and increasingly found with longer-span fixed partial prostheses (P=.007). Five FDPs had to be replaced because of complete failure, the most frequent cause of failure being secondary caries (P=.003). The mean survival rate (no failures) was 11 years 4 months (95% confidence interval, 10.3-12.7). CONCLUSIONS: Zirconia FDPs had an 81.5% survival rate over 12 years. A higher incidence of complications took place during the first 3 years, the most common being chipping.


Subject(s)
Biological Products , Dental Caries , Dental Caries/etiology , Dental Materials , Dental Porcelain/therapeutic use , Dental Restoration Failure , Dental Veneers , Denture, Partial, Fixed , Esthetics, Dental , Humans , Prospective Studies , Zirconium/therapeutic use
9.
J Prosthet Dent ; 128(5): 942-948, 2022 Nov.
Article in English | MEDLINE | ID: mdl-33715832

ABSTRACT

STATEMENT OF PROBLEM: Rehabilitation of edentulous patients with severe maxillary atrophy is a clinical challenge. Although several treatment options are available, the implant-supported overdenture has been widely advocated. However vertical insertion implant-supported overdentures have drawbacks, including wear, aging, and the continuous maintenance of retention systems. Whether an implant-supported overdenture with a horizontal insertion pathway can overcome these problems is unclear. PURPOSE: The purpose of this observational study was to determine the clinical and biological behavior of a new type of implant-supported overdenture with a horizontal insertion pathway over a mean clinical follow-up period of 6 years. MATERIAL AND METHODS: Ten study participants with an atrophic maxilla underwent rehabilitation with horizontal overdentures supported by 6 implants. Follow-up visits were scheduled at 3 months, 6 months, and annually thereafter. The variables analyzed were implant and prosthetic survival, peri-implant tissue behavior, mechanical complications, and patient satisfaction. RESULTS: The follow-up period ranged from 5 to 8 years, mean ±standard deviation 6.3 ±1.2 years. A total of 60 implants and 10 horizontal overdentures were placed. The clinical survival of the implants was 98.3% (mean peri-implant bone loss, 1.3 ±0.4 mm) and was 80% of the prostheses. Overall, mean patient satisfaction as assessed with a visual analog scale was 7.4, with 8.5 for esthetics and 9.5 for function. CONCLUSIONS: The horizontal implant-supported overdenture provided a functional alternative to conventional prostheses.


Subject(s)
Dental Implants , Jaw, Edentulous , Mouth, Edentulous , Humans , Denture, Overlay , Maxilla/surgery , Maxilla/pathology , Dental Prosthesis, Implant-Supported , Esthetics, Dental , Mouth, Edentulous/surgery , Mouth, Edentulous/pathology , Patient Satisfaction , Atrophy/pathology , Jaw, Edentulous/rehabilitation , Follow-Up Studies , Treatment Outcome
10.
J Prosthodont Res ; 66(2): 193-207, 2022 Apr 27.
Article in English | MEDLINE | ID: mdl-34176849

ABSTRACT

PURPOSE: This systematic review set out to investigate the influence of chemical composition and specimen thickness of monolithic zirconia on its optical and mechanical properties. Meta-analysis and meta-regression analyzed the effects of variations in percentages of yttrium, aluminum, and specimen thickness of monolithic zirconia. STUDY SELECTION: The review followed recommendations put forward in the PRISMA checklist. An electronic search for relevant articles published up to October 2019 was conducted in the Pubmed, Cochrane, Scopus, Scielo, and Web of Science databases, with no language limits and articles published in the last 10 years. From 167 relevant articles; applying inclusion criteria based on the review's PICO question, 26 articles were selected for qualitative synthesis (systematic review) and 24 for quantitative synthesis (meta-analysis). Experimental in vitro studies published were selected and their quality was assessed using the modified Consort scale for in vitro studies of dental materials. RESULTS: The variables yttrium, aluminum and thickness were analyzed in random effects models, observing high heterogeneity (>75%), and finding statistically significant influences on the properties of monolithic zirconia (p<0.05). CONCLUSION: Within the review's limitations, it may be concluded that variations in the percentage of yttrium and aluminum influence the optical and mechanical properties of monolithic zirconia, making it more or less esthetic and resistant in relation to each variable. The clinical implications of these findings can help select the most appropriate type of zirconia to meet the different clinical needs when restoring different regions (posterior or anterior).


Subject(s)
Ceramics , Dental Materials , Aluminum , Ceramics/chemistry , Dental Materials/chemistry , Materials Testing , Surface Properties , Yttrium , Zirconium/chemistry
12.
Mol Clin Oncol ; 15(2): 150, 2021 Aug.
Article in English | MEDLINE | ID: mdl-34141429

ABSTRACT

The present study aimed to evaluate the impact caused by the 2016 World Health Organization (WHO) diagnostic classification of gliomas in 139 patients studied in Argentina. Formalin-fixed paraffin-embedded tissues were used for histological and immunohistochemical analysis [glial fibrillary acidic protein, KI67, synaptophysin and isocitrate dehydrogenase (IDH)1-R132H]. DNA from formalin-fixed paraffin-embedded tissues was used for molecular analysis: 1p/19q co-deletion and mutation status of the IDH gene. These experiments were performed by direct Sanger sequencing and multiplex ligation-dependent probe amplification. According to the new classification, diagnoses included oligodendroglioma IDH-mutant and 1p/19q co-deletion (4.20%), anaplastic oligodendroglioma IDH-mutant and 1p/19q co-deletion (2.52%), diffuse astrocytoma IDH-mutant (6.72%), diffuse astrocytoma IDH-wild type (1.68%), anaplastic astrocytoma IDH-mutant (5.04%), anaplastic astrocytoma IDH-wild type (8.40%), glioblastoma IDH-mutant (5.88%) and glioblastoma IDH-wild type (65.56%). Regarding tumor histology, 60% of oligodendrogliomas, 35% of astrocytoma and 100% of unclassified gliomas were re-classified, while glioblastomas maintained their initial classification. Additionally, the present study evaluated the prognostic value of the histological grade for the 2007 and 2016 WHO classifications of gliomas. The histological subgroup associated with longer overall survival (OS) was grade II glioma (OS-2007WHO, 35.6 months; and OS-2016WHO, 47.7 months). Glioblastoma was the subgroup associated with a poor outcome (OS-2007WHO, 10.4 months; and OS-2016WHO, 11.1 months). The present study evaluated the OS of tumor grade subgroups with respect to their IDH status. For all subgroups, IDH-mutant tumors were associated with an improved prognosis compared with IDH-wild type tumors. The results suggested that the incorporation of molecular biomarkers in the new WHO classification improves tumor characterization and prognostic value of the subgroups.

13.
Article in English | MEDLINE | ID: mdl-33322472

ABSTRACT

OBJECTIVE: To evaluate the influence of implant length on marginal bone loss, comparing implants of 4 mm, 6 mm, and >8 mm, supporting two splinted crowns after 36-month functional loading. MATERIALS AND METHODS: this retrospective clinical trial evaluated the peri-implant behavior of splinted crowns (two per case) on pairs of implants of the same length placed in the posterior maxilla (molar area). Implants were divided into three groups according to length (Group 1: extra-short 4 mm; Group 2: short 6 mm; Group 3: conventional length >8 mm). Marginal bone loss was analyzed using standardized periapical radiographs at the time of loading and 36 months later. RESULTS: 24 patients (19 women and 5 men) were divided into three groups, eight rehabilitations per group, in the position of the maxillary first and second molars. The 48 Straumann® Standard Plus (Regular Neck (RN)/Wide Neck (WN)) implants were examined after 36 months of functional loading. Statistical analysis found no significant differences in bone loss between the three groups (p = 0.421). No implant suffered biological complications or implant loss. Long implants were associated with less radiographic bone loss. CONCLUSIONS: extra-short (4 mm); short (6 mm); and conventional length (>8 mm) implants in the posterior maxilla present similar peri-implant bone loss and 100% survival rates in rehabilitation, by means of two splinted crowns after 36 months of functional loading. Implants placed in posterior positions present better bone loss results than implants placed in anterior positions, regardless of the interproximal area where bone loss is measured. Conventional length (>8 mm) implants show better behavior in terms of distal bone loss than short (6 mm) and extra-short (4 mm) implants.


Subject(s)
Alveolar Bone Loss/diagnosis , Crowns , Dental Implants/classification , Molar , Dental Restoration Failure , Female , Follow-Up Studies , Humans , Male , Retrospective Studies , Treatment Outcome
14.
Article in English | MEDLINE | ID: mdl-33086485

ABSTRACT

A systematic review and meta-analysis was performed to analyze the survival of onlay restorations in the posterior region, their clinical behavior according to the material used (ceramic reinforced with lithium disilicate, conventional feldspathic ceramic or reinforced with leucite; hybrid materials and composite), possible complications, and the factors influencing restoration success. The systematic review was based on the preferred reporting items for systematic reviews and meta-analyses (PRISMA) statement, without publication date or language restrictions. An electronic search was made in the PubMed, Scopus, Embase, and Cochrane databases. After discarding duplicate publications and studies that failed to meet the inclusion criteria, the articles were selected based on the population, intervention, comparison, outcome (PICO) question. The following variables were considered in the qualitative and quantitative analyses: restoration survival rate (determined by several clinical parameters), the influence of the material used upon the clinical behavior of the restorations, and the complications recorded over follow-up. A total of 29 articles were selected for the qualitative analysis and 27 for the quantitative analysis. The estimated restoration survival rate was 94.2%. The predictors of survival were the duration of follow-up (beta = -0.001; p = 0.001) and the onlay material used (beta = -0.064; p = 0.028). Composite onlays were associated with a lower survival rate over time. Onlays are a good, conservative, and predictable option for restoring dental defects in the posterior region, with a survival rate of over 90%. The survival rate decreases over time and with the use of composite as onlay material.


Subject(s)
Ceramics , Dental Restoration Failure , Inlays , Composite Resins , Humans
15.
J Clin Med ; 9(4)2020 Apr 02.
Article in English | MEDLINE | ID: mdl-32252404

ABSTRACT

BACKGROUND: The aim of this systematic review and meta-analysis was to determine the wear sustained in the natural antagonist tooth in cases of full-coverage fixed-base prosthetic restorations or monolithic zirconia tooth-supported crowns, as well as to determine the wear in the restoration itself, both in the short- and medium-term and considering the factors that may influence wear. MATERIAL AND METHODS: A systematic literature review and meta-analysis, based on Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) recommendations, of clinical studies that evaluated wear in antagonist teeth in relation to fixed-prosthesis monolithic zirconia crowns. A total of 5 databases were consulted in the literature search: Pubmed-Medline, Cochrane, Scopus, Embase and Web of Science (WOS). After eliminating duplicated articles and applying the inclusion criteria, eight articles were selected for the qualitative analysis and four for the quantitative analysis. RESULTS: Mean maximum wear of the antagonist tooth in relation to monolithic zirconia crowns of magnitude 95.45 µm (CI at 95% 79.57-111.33) was observed. By using a meta-regression model (R2 = 0.92) the significant effect of time in maximum wear rate (p < 0.001) was observed, estimated at 6.13 µm per month (CI at 95% 3.99-8.27). Furthermore, monolithic zirconia crowns are subject to a mean maximum wear of 58.47 µm (CI 95% 45.44-71.50). By using a meta-regression model (R2 = 0.53) the significant effect of time in the maximum wear value was observed (p = 0.053), estimated at 3.40 µm per month (CI al 95% -0.05-6.85). CONCLUSIONS: Monolithic zirconia crowns lead to a progressive maximum wear of the antagonist tooth over time which is greater than the maximum wear sustained in the crown itself. It is not possible to establish an objective and quantitative objection in relation to natural enamel wear or metal-ceramic crowns.

16.
Medicina (Kaunas) ; 56(3)2020 Mar 19.
Article in English | MEDLINE | ID: mdl-32204564

ABSTRACT

Background and objectives: To compare the medium- to long-term mechanical behavior of overdentures with two different retention systems: overdentures with Locator® axial retention, and vertical insertion overdentures with bar retention, used to rehabilitate edentulous maxillar. Material and Methods: This prospective study assessed patients presenting complete maxillary edentulism, rehabilitated by means of implant-supported overdentures (n = 20), 10 with Locator® axial retention (ODA group) and 10 with overdentures on bars (ODB group). Patients also completed a questionnaire to determine their satisfaction with treatment. Results: The mean follow-up time in both groups was 11.4 years, with follow-up times in both groups ranging from 5 to 14 years. The ODA group suffered mechanical complications such as retention loss, need for nylon retention insert changes, resin fracture, and need for relining. In the ODB group, prosthetic dental wear, screw loosening, and complete prosthetic failure were more common. A total of 19 implants failed (23.8%); of these, 11 were in the ODA group (failure rate = 27.5%) and eight in the ODB group (failure rate = 20%). The patient satisfaction questionnaire obtained a mean score of 7.9 out of 10 in the ODA group, and 9.75 in the ODB group. Conclusions: in rehabilitations of edentulous maxillar by means of implant-supported overdentures, both the systems assessed were shown to be effective in the medium to long term. Patients expressed a high level of satisfaction with the treatments received.


Subject(s)
Dental Implants/adverse effects , Dental Prosthesis Retention/trends , Denture, Overlay/adverse effects , Mouth, Edentulous/rehabilitation , Aged , Cohort Studies , Dental Implants/psychology , Dental Prosthesis Retention/psychology , Dental Prosthesis, Implant-Supported/psychology , Dental Prosthesis, Implant-Supported/statistics & numerical data , Dental Restoration Failure/statistics & numerical data , Denture, Overlay/psychology , Female , Follow-Up Studies , Humans , Male , Mechanical Phenomena , Mouth, Edentulous/surgery , Patient Satisfaction , Prospective Studies , Surveys and Questionnaires/standards , Treatment Outcome
17.
J Clin Med ; 9(1)2020 Jan 17.
Article in English | MEDLINE | ID: mdl-31963494

ABSTRACT

BACKGROUND: The objective of this systematic review and meta-analysis was to analyze the periodontal behavior around teeth prepared with horizontal finishing crowns supporting fixed metal-ceramic and zirconia full coverage crowns and fixed partial dentures (FDPs). MATERIALS AND METHODS: An electronic search was conducted to locate relevant clinical trials in four databases: PubMed, Embase, Cochrane, and Scopus. A manual search was made in the reference sections of the articles identified for any additional articles. No restrictions were applied regarding year of publication or language. The following variables were considered in quantitative and qualitative analysis: probing pocket depth (PPD); probing attachment level (PAL); plaque control record (PCR); bleeding on probing (BOP); and gingival margin migration. RESULTS: Twenty articles were selected for qualitative synthesis, and of these, nine underwent meta-analysis. Higher PCR was found in control teeth, while BOP, PPD, and PAL were higher around teeth prepared with horizontal finishing lines supporting complete coverage crowns/FDPs Gingival migration results were the clearest manifestation of compromised periodontal health around teeth prepared with horizontal finishing lines. CONCLUSIONS: Meta-analysis revealed that teeth prepared with horizontal finishing lines supporting crowns and FDPs present more periodontal disorders than untreated control teeth.

18.
Rev Alerg Mex ; 67(4): 316-328, 2020.
Article in Spanish | MEDLINE | ID: mdl-33631900

ABSTRACT

BACKGROUND: The hemophagocytic syndrome is a serious complication of several systemic illnesses. OBJECTIVE: To define the characteristics of the hemophagocytic syndrome at a pediatric specialty hospital in Tuxtla Gutiérrez, Chiapas, Mexico; incidences, underdiagnosis and overdiagnosis, associated conditions, treatment, and prognosis were included. METHODS: 214 cases of probable hemophagocytic syndrome that were seen between January 2011 and May 2019 were analyzed. 26 patients diagnosed with hemophagocytic syndrome and 188 cases with suspicion of this entity and/or ferritin > 500 ug/L were included. The cases that met four or more criteria of the HFS (Histiocyte Society, 2004) were included in this study. RESULTS: Thirty-five cases were validated (fourteen were previously diagnosed, nine had suspicion, and twelve had ferritin > 500 µg/L). Neither twelve out of 26 of the cases that were previously diagnosed (46.2 % overdiagnosed). Of the 35 validated cases, 21 hadn't been diagnosed (60 % underdiagnosed) met the diagnostic criteria of the HFS. The annual occurrence was of 2.0/1000 egresses. The Epstein-Barr virus was involved in 42 % of the cases. The overall mortality was of 80 %. CONCLUSIONS: Hemophagocytic syndrome had been significantly underdiagnosed and overdiagnosed at the analyzed hospital. The clinical features allow early suspicion, diagnosis, and treatment. Specific and non-specific illnesses that were associated to hemophagocytic syndrome were identified.


Antecedentes: El síndrome hemofagocítico es una complicación grave que se observa en diversos padecimientos sistémicos. Objetivo: Conocer las características del síndrome hemofagocítico en el Hospital de Especialidades Pediátricas de Tuxtla Gutiérrez, Chiapas, México; se incluyó incidencia, subdiagnóstico y sobrediagnóstico, padecimientos asociados, tratamiento y pronóstico. Métodos: Se analizaron 214 casos probables de síndrome hemofagocítico atendidos entre enero de 2011 y mayo de 2019. Se incluyeron 26 pacientes con diagnóstico de síndrome hemofagocítico y 188 en los que se sospechaba esta entidad o con ferritina > 500 µg/L. Los casos en los que se cumplieron cuatro o más criterios de la Sociedad del Histiocito fueron incluidos en el estudio. Resultados: Se validaron 35 casos (14 con diagnóstico previo, nueve con sospecha y 12 con ferritina > 500 µg/L). No cumplieron con los criterios de la Sociedad del Histiocito, 12 casos diagnosticados previamente (sobrediagnóstico de 46.2 %). De los 35 validados, 21 no habían sido diagnosticados (subdiagnóstico de 60 %). La incidencia anual fue de 2.0/1000 egresos. El virus Epstein-Barr estuvo involucrado en 42 % de los casos. La mortalidad representó 80 %. Conclusiones: El síndrome hemofagocítico fue subdiagnosticado y sobrediagnosticado en el hospital estudiado. Las características clínicas permiten sospecharlo, diagnosticarlo y tratarlo oportunamente. Se identificaron padecimientos específicos y no específicos asociados a síndrome hemofagocítico.


Subject(s)
Epstein-Barr Virus Infections , Lymphohistiocytosis, Hemophagocytic , Child , Herpesvirus 4, Human , Hospitals , Humans , Lymphohistiocytosis, Hemophagocytic/diagnosis , Lymphohistiocytosis, Hemophagocytic/epidemiology , Medical Overuse
19.
J Clin Med ; 8(12)2019 Dec 11.
Article in English | MEDLINE | ID: mdl-31835749

ABSTRACT

PURPOSE: The objective of this prospective randomized clinical trial (RCT) was to analyze and compare the clinical behavior of three types of prosthesis supported by single implants in the posterior region after three years functional loading. MATERIALS AND METHODS: Seventy-five implants were divided into three groups according to the type of prosthetic restoration: screw-retained crown (Group GS); cemented crown without finishing line (biologically oriented preparation technique) (Group GBOPT); and conventional cemented crown with finishing line (Group GCC). The clinical behavior of each restoration type was analyzed after 3 years functional loading by analyzing radiographic peri-implant bone loss. RESULTS: GBOPT obtained the least bone loss (p < 0.01) in comparison with GS and GCC. CONCLUSIONS: Bone loss around implants is related to the type of prosthetic restoration it supports, whereby cemented BOPT crowns present less bone loss.

20.
J Clin Med ; 8(11)2019 Nov 09.
Article in English | MEDLINE | ID: mdl-31717610

ABSTRACT

BACKGROUND: The aim of this systematic review and meta-analysis was to determine the fracture resistance and survival rate of partial indirect restorations inlays, onlays, and overlays fabricated using computer-aided design and computer-aided manufacturing (CAD-CAM) technology from ceramics, composite resin, resin nanoceramic, or hybrid ceramic and to analyze the influence of proximal box elevation on fracture resistance. MATERIALS AND METHODS: This systematic review was based on guidelines proposed by the preferred reporting items for systematic reviews and meta-analyses (PRISMA). An electronic search was conducted in databases US National Library of Medicine National Institutes of Health (PubMed), Scopus, Web of Science (WOS), and Embase. In vitro trials published during the last 10 years were included in the review. RESULTS: Applying inclusion criteria based on the review's population, intervention, comparison, outcome (PICO) question, 13 articles were selected. Meta-analysis by restoration type estimated the fracture resistance of inlays to be 1923.45 Newtons (N); of onlays 1644 N and of overlays 1383.6 N. Meta-analysis by restoration material obtained an estimated fracture resistance for ceramic of 1529.5 N, for composite resin of 1600 Ne, for resin nanoceramic 2478.7 N, and hybrid ceramic 2108 N. CONCLUSIONS: Resin nanoceramic inlays present significantly higher fracture resistance values. Proximal box elevation does not exert any influence on the fracture resistance of indirect restorations.

SELECTION OF CITATIONS
SEARCH DETAIL
...