Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Publication year range
1.
Gac Med Mex ; 157(2): 167-173, 2021.
Article in English | MEDLINE | ID: mdl-34270528

ABSTRACT

INTRODUCTION: Promoting breast cancer (BC) detection in women by means of mammography is a viable strategy to reduce the number of diagnoses at clinically advanced stages and mortality. OBJECTIVES: To describe the results reported by mammography studies in women, carried out nationally during 2013-2017, and to analyze the spatiotemporal trend of Breast Imaging Reporting and Data System (BIRADS) categories suggestive of malignancy by State. METHOD: Longitudinal, analytical design that included information on mammography studies of women according to age group (< 40 and ≥ 40), evaluated in units of the Ministry of Health of Mexico during 2013-2017. The frequency of BIRADS categories and a standardized rate suggestive of malignancy (categories 4 and 5) were estimated in women aged ≥ 40 years, and spatial statistics were used to analyze the trend by State. RESULTS: A total of 3,659,151 mammograms were analyzed, 98.5 % in women aged ≥ 40 years. The malignancy-suggestive rate decreased from 38.3 (2013) to 31 (2017) per 100,000 women aged ≥ 40 years; however, the risk of detection increased up to 13 times in ten States. CONCLUSIONS: Although the risk of detection in categories suggestive of malignancy decreased at the national level, some States need to reinforce the application of BC detection programs through mammography and increase the participation of the target population.


INTRODUCCIÓN: Promover la detección de cáncer de mama (CaMa) en mujeres mediante mastografía es una estrategia viable para disminuir los diagnósticos en fases clínicamente avanzadas y la mortalidad. OBJETIVOS: Describir los resultados reportados por estudios de mastografía en mujeres realizados a nivel nacional durante 2013-2017 y analizar la tendencia espaciotemporal de categorías BIRADS (Breast Imaging Reporting and Data System) sugestivas de malignidad por Estado. MÉTODO: Diseño analítico longitudinal que incluyó información sobre estudios de mastografía de mujeres según grupo de edad (< 40 e ≥ 40), valoradas en unidades de la Secretaría de Salud, México, durante 2013-2017. Se estimó la frecuencia de categorías según BIRADS, tasa estandarizada sugestiva de malignidad (categorías 4 y 5) en mujeres ≥ 40 años y se utilizó estadística espacial para analizar la tendencia por Estado. RESULTADOS: Se analizaron 3,659,151 mastografías, el 98.5 % en mujeres ≥ 40 años. La tasa sugestiva de malignidad disminuyó de 38.3 (2013) a 31 (2017) por 100 mil mujeres ≥ 40 años; sin embargo, el riesgo de detección aumentó hasta 13 veces en diez Estados. CONCLUSIONES: Aunque el riesgo de detección en categorías sugestivas de malignidad disminuyó a nivel nacional, algunos Estados requieren reforzar la aplicación de programas de detección del CaMa mediante mastografía e incrementar la participación de la población blanco.


Subject(s)
Breast Neoplasms/diagnostic imaging , Mammography/statistics & numerical data , Spatio-Temporal Analysis , Adult , Age Factors , Aged , Breast Neoplasms/classification , Breast Neoplasms/epidemiology , Female , Humans , Linear Models , Mammography/classification , Mexico/epidemiology , Middle Aged , Patient Participation/statistics & numerical data , Space-Time Clustering
2.
Gac. méd. Méx ; 157(2): 174-180, mar.-abr. 2021. tab, graf
Article in Spanish | LILACS | ID: biblio-1279098

ABSTRACT

Resumen Introducción: Promover la detección de cáncer de mama (CaMa) en mujeres mediante mastografía es una estrategia viable para disminuir los diagnósticos en fases clínicamente avanzadas y la mortalidad. Objetivos: Describir los resultados reportados por estudios de mastografía en mujeres realizados a nivel nacional durante 2013-2017 y analizar la tendencia espaciotemporal de categorías BIRADS (Breast Imaging Reporting and Data System) sugestivas de malignidad por Estado. Método: Diseño analítico longitudinal que incluyó información sobre estudios de mastografía de mujeres según grupo de edad (< 40 e ≥ 40), valoradas en unidades de la Secretaría de Salud, México, durante 2013-2017. Se estimó la frecuencia de categorías según BIRADS, tasa estandarizada sugestiva de malignidad (categorías 4 y 5) en mujeres ≥ 40 años y se utilizó estadística espacial para analizar la tendencia por Estado. Resultados: Se analizaron 3,659,151 mastografías, el 98.5 % en mujeres ≥ 40 años. La tasa sugestiva de malignidad disminuyó de 38.3 (2013) a 31 (2017) por 100 mil mujeres ≥ 40 años; sin embargo, el riesgo de detección aumentó hasta 13 veces en diez Estados. Conclusiones: Aunque el riesgo de detección en categorías sugestivas de malignidad disminuyó a nivel nacional, algunos Estados requieren reforzar la aplicación de programas de detección del CaMa mediante mastografía e incrementar la participación de la población blanco.


Abstract Introduction: Promoting breast cancer (BC) detection in women by means of mammography is a viable strategy to reduce the number of diagnoses at clinically advanced stages and mortality. Objectives: To describe the results reported by mammography studies in women, carried out nationally during 2013-2017, and to analyze the spatiotemporal trend of Breast Imaging Reporting and Data System (BIRADS) categories suggestive of malignancy by State. Method: Longitudinal, analytical design that included information on mammography studies of women according to age group (< 40 and ≥ 40), evaluated in units of the Ministry of Health of Mexico during 2013-2017. The frequency of BIRADS categories and a standardized rate suggestive of malignancy (categories 4 and 5) were estimated in women aged ≥ 40 years, and spatial statistics were used to analyze the trend by State. Results: A total of 3,659,151 mammograms were analyzed, 98.5 % in women aged ≥ 40 years. The malignancy-suggestive rate decreased from 38.3 (2013) to 31 (2017) per 100,000 women aged ≥ 40 years; however, the risk of detection increased up to 13 times in ten States. Conclusions: Although the risk of detection in categories suggestive of malignancy decreased at the national level, some States need to reinforce the application of BC detection programs through mammography and increase the participation of the target population.


Subject(s)
Humans , Female , Adult , Middle Aged , Aged , Breast Neoplasms/diagnostic imaging , Mammography/statistics & numerical data , Spatio-Temporal Analysis , Patient Participation/statistics & numerical data , Breast Neoplasms/classification , Breast Neoplasms/epidemiology , Mammography/classification , Linear Models , Space-Time Clustering , Age Factors , Mexico/epidemiology
3.
Water Res ; 47(12): 4095-106, 2013 Aug 01.
Article in English | MEDLINE | ID: mdl-23562563

ABSTRACT

Nanoscale zerovalent iron (NZVI) such as Toda Kogyo RNIP-10DS has been used for site remediation, yet information is lacking regarding how far injected NZVI can travel, how long it lasts, and how it transforms to other minerals in a groundwater system. Previously we reported effective mass destruction of chlorinated ethenes dominated by tetrachloroethene (PCE) using emulsified zerovalent iron (EZVI) nanoparticles of RNIP-10DS in a shallow aquifer (1-6 m below ground surface, BGS) at Site 45, Marine Corps Recruit Depot, Parris Island, South Carolina, USA. Here we report test results on transport and transformation of injected EZVI in the subsurface. We employed two EZVI delivery methods: pneumatic injection and direct injection. Effective delivery of EZVI to the targeted zone was achieved with pneumatic injection showing a travel distance from injection points of up to 2.1 m and direct injection showing a travel distance up to 0.89 m. X-ray diffraction and scanning electron microscopy studies on particles harvested from well purge waters indicated that injected black colored NZVI (α-Fe(0)) was transformed largely to black colored cube-like and plate-like magnetites (Fe3O4, 0.1-1 µm, 0-9 months), then to orange colored irregularly shaped lepidocrocite (γ-FeOOH, 0.1-1 µm, 9 months to 2.5 years), then to yellowish lath-like goethite (α-FeOOH, 2-5 µm, 2.5 years) and ferrihydrite-like spherical particles (0.05-0.1 µm) in the top portion of the aquifer (1-2 m BGS). No α-Fe(0) was found in most monitoring wells three months after injection. The formed iron oxides appeared to have a wider range of particle size (submicron to 5 µm) than the pristine NZVI (35-140 nm). Injected NZVI was largely transformed to magnetite (0.1-1 µm) during two and half years in the lower portion of the aquifer (3-6 m).


Subject(s)
Emulsions/chemistry , Iron/chemistry , Metal Nanoparticles/chemistry , Metal Nanoparticles/ultrastructure , Particle Size , South Carolina , Surface Properties , Time Factors , X-Ray Diffraction
4.
Water Res ; 46(16): 5071-84, 2012 Oct 15.
Article in English | MEDLINE | ID: mdl-22868086

ABSTRACT

A field test of emulsified zero valent iron (EZVI) nanoparticles was conducted at Parris Island, SC, USA and was monitored for two and half years to assess the treatment of subsurface-source zone chlorinated volatile organic compounds (CVOCs) dominated by tetrachloroethene (PCE) and its chlorinated daughter products. Two EZVI delivery methods were used: pneumatic injection and direct injection. In the pneumatic injection plot, 2180 L of EZVI containing 225 kg of iron (Toda RNIP-10DS), 856 kg of corn oil, and 22.5 kg of surfactant were injected to remedy an estimated 38 kg of CVOCs. In the direct injection plot, 572 L of EZVI were injected to treat an estimated 0.155 kg of CVOCs. After injection of the EZVI, significant reductions in PCE and trichloroethene (TCE) concentrations were observed in downgradient wells with corresponding increases in degradation products including significant increases in ethene. In the pneumatic injection plot, there were significant reductions in the downgradient groundwater mass flux values for PCE (>85%) and TCE (>85%) and a significant increase in the mass flux of ethene. There were significant reductions in total CVOC mass (86%); an estimated reduction of 63% in the sorbed and dissolved phases and 93% reduction in the PCE DNAPL mass. There are uncertainties in these estimates because DNAPL may have been mobilized during and after injection. Following injection, significant increases in dissolved sulfide, volatile fatty acids (VFA), and total organic carbon (TOC) were observed. In contrast, dissolved sulfate and pH decreased in many wells. The apparent effective remediation seems to have been accomplished by direct abiotic dechlorination by nanoiron followed by biological reductive dechlorination stimulated by the corn oil in the emulsion.


Subject(s)
Environmental Monitoring/methods , Environmental Restoration and Remediation/methods , Groundwater/analysis , Iron/chemistry , Metal Nanoparticles/chemistry , Tetrachloroethylene/chemistry , Water Pollutants, Chemical/chemistry , Environmental Monitoring/statistics & numerical data , Longitudinal Studies , South Carolina , Tetrachloroethylene/isolation & purification , Time Factors , Water Pollutants, Chemical/isolation & purification
SELECTION OF CITATIONS
SEARCH DETAIL
...