Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Eur J Cardiothorac Surg ; 52(2): 234-240, 2017 Aug 01.
Article in English | MEDLINE | ID: mdl-28444210

ABSTRACT

OBJECTIVES: We investigated the impact of initial shunt type, a Blalock-Taussig (BT) shunt versus a right ventricle to pulmonary artery conduit (RV-PA) on myocardial function at different stages of surgical palliation in patients with hypoplastic left heart syndrome (HLHS). METHODS: A population-based cohort of 63 Finnish children with HLHS (BT n = 23, RV-PA n = 40) born between 2003 and 2010 were studied retrospectively by echocardiography prior to Stages 1, 2 and 3 palliation and 0.5-3 years after Stage 3. For comparison of systolic myocardial function, we evaluated the RV fractional area change (FAC), strain, strain rate and mechanical synchrony from the apical 4-chamber view by velocity vector imaging. RESULTS: There were no intergroup differences in demographics during the study period. At baseline, no intergroup differences were detected in RV systolic myocardial function. Before Stage 2, RV FAC was higher ( P = 0.03) in the RV-PA conduit group. At Stage 3, an increase in all systolic myocardial functional parameters was observed in the BT shunt group. After Stage 3, the BT shunt group had better RV systolic function. In multiple regression analysis, the shunt type and the stage of palliation had an impact on myocardial function. CONCLUSIONS: Although patients with HLHS initially palliated with a BT shunt demonstrate lower RV FAC after Stage I, RV FAC improves after Stage 2 with better systolic performance after Stage 3 compared with those initially palliated with an RV-PA conduit.


Subject(s)
Blalock-Taussig Procedure/statistics & numerical data , Heart/physiopathology , Hypoplastic Left Heart Syndrome/epidemiology , Hypoplastic Left Heart Syndrome/surgery , Norwood Procedures/statistics & numerical data , Cardiac Catheterization , Child, Preschool , Echocardiography , Female , Heart/diagnostic imaging , Humans , Hypoplastic Left Heart Syndrome/diagnostic imaging , Infant , Infant, Newborn , Male , Norwood Procedures/instrumentation , Palliative Care , Retrospective Studies
2.
Echocardiography ; 34(4): 587-593, 2017 Apr.
Article in English | MEDLINE | ID: mdl-28191731

ABSTRACT

BACKGROUND: Quantitative echocardiographic assessment of right ventricular function is important in children with hypoplastic left heart syndrome (HLHS). The aim of this study was to examine the repeatability of different echocardiographic techniques, both manual and automated, to measure fractional area change (FAC) in patients with HLHS and to correlate these measurements with magnetic resonance imaging (MRI)-derived ejection fraction (EF). METHODS: Fifty-one children with HLHS underwent transthoracic echocardiography and cardiac MRI under the same general anesthetic as part of routine inter-stage assessment. FAC was measured from the apical four-chamber view using three different techniques: velocity vector imaging (VVI) (Syngo USWP 3.0; Siemens Healthineers), QLAB (Q-lab R 10.0; Philips Healthcare), and manual endocardial contour tracing (Xcelera, Philips Healthcare). Intra- and inter-observer variability was calculated using intra-class correlation coefficient (ICC). FAC was correlated with MRI EF calculated using a single standard method. RESULTS: Fractional area change had a good correlation with MRI-derived EF with an R value for VVI, QLAB, and manual methods of .7, .6, and .4, respectively. Intra- and inter-observer variability for FAC was good for automated echocardiographic methods (ICC>.85) but worse for manual method particularly inter-observer variability of FAC and end-systolic area. Both automated techniques tended to produce higher FAC values compared with manual measurements (P<.001). CONCLUSION: Automation improves the repeatability of FAC in HLHS. There are some differences between automated software in terms of correlation with MRI-derived EF. Measurement bias and wide limits of agreement mean that the same echocardiographic technique should be used during the follow-up of individual patients.


Subject(s)
Echocardiography/methods , Hypoplastic Left Heart Syndrome/complications , Image Processing, Computer-Assisted/methods , Ventricular Dysfunction, Right/complications , Ventricular Dysfunction, Right/diagnostic imaging , Adolescent , Child , Child, Preschool , Female , Heart Ventricles/diagnostic imaging , Heart Ventricles/physiopathology , Humans , Hypoplastic Left Heart Syndrome/physiopathology , Infant , Magnetic Resonance Imaging , Male , Observer Variation , Reproducibility of Results , Software , Ventricular Dysfunction, Right/physiopathology
SELECTION OF CITATIONS
SEARCH DETAIL
...