Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Appl Gerontol ; : 7334648241258024, 2024 Jun 05.
Article in English | MEDLINE | ID: mdl-38836294

ABSTRACT

Dementia care management, an evidence-based care concept in Germany, optimizes care for people with dementia and their caregivers. Implemented by qualified professionals, it comprises intervention modules addressing treatment and care, medication management, and caregiver support. Positively evaluated in one federal state, it's recommended for nationwide integration into routine care. Since the infrastructure of the German healthcare system differs regionally, the concept underwent adaption for regional implementation in a participatory, iterative process. Five local healthcare experts as co-researchers tested and adjusted selected components of the concept in a pilot study. This trend analysis aims to assess the adapted concept for acceptance, appropriateness, and feasibility. A total of 89 intervention modules were tested over 18 weeks, and the co-researcher's assessment was gathered through an accompanying online survey. The participatory process itself was rated positively overall, but technical problems had a negative impact on the implementation and evaluation of the care concept.

2.
Head Face Med ; 15(1): 21, 2019 Aug 08.
Article in English | MEDLINE | ID: mdl-31395069

ABSTRACT

BACKGROUND: The required pretreatment of CAD/CAM ceramic materials before resin composite cement application varies among studies. The aim of the present study was to evaluate the effect of hydrofluoric acid concentration and etching time on the shear bond strength (SBS) of two adhesive and two self-adhesive resin composite cements to different CAD/CAM ceramic materials. METHODS: SBS of two adhesive (Panavia V5, Kuraray, [PV5]; Vita Adiva F-Cem, Vita Zahnfabrik, [VAF]) and two self-adhesive (RelyX Unicem 2 Automix, 3 M Espe, [RUN]; Vita Adiva S-Cem, Vita, [VAS]) cements to four different CAD/CAM materials (Vitablocs Mark II, Vita, [VM]; Vita Enamic, Vita, [VE]; e.max CAD, Ivoclar Vivadent, [EC]; Vita Suprinity PC, Vita, [VS]) was measured. The effect of the surface pretreatment by using two different hydrofluoric acid products (HF5% Vita Ceramics Etch, Vita and HF9% buffered, Ultradent Porcelain Etch, Ultradent Products) were assessed at etching times of 0 s, 5 s, 15 s, 30s and 60s for each cement and restorative material combination (n = 10 per group, total n = 1440). RESULTS: Significant effects were found for the etching time and cement for all materials with highest shear bond strength for etching times of 60s = 30s = 15 s ≥ 5 s > 0 s and for RUN>PV5 = VAF > VAS (p < 0.05). Etching with HF5% for 5 s to 15 s resulted in higher SBS values, while no differences were observed between HF5% and HF9% buffered when the substrates were etched for 30s to 60s (p < 0.05). CONCLUSIONS: Within the limitations of this study the recommended surface pretreatment of silicate ceramics is HF etching with concentrations of 5% or 9% for 15 s to 60s to achieve highest shear bond strength while the glassy matrix is sufficiently dissolved. The tested resin composite cements can be applied with all tested materials and suggested for clinical application.


Subject(s)
Computer-Aided Design , Dental Bonding , Resin Cements , Ceramics , Dental Materials , Materials Testing , Shear Strength , Surface Properties
SELECTION OF CITATIONS
SEARCH DETAIL
...