Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 114
Filter
1.
Phys Rev Lett ; 131(22): 222501, 2023 Dec 01.
Article in English | MEDLINE | ID: mdl-38101385

ABSTRACT

We report on the results obtained with the global CUPID-0 background model, which combines the data collected in the two measurement campaigns for a total exposure of 8.82 kg×yr of ^{82}Se. We identify with improved precision the background sources within the 3 MeV energy region, where neutrinoless double ß decay of ^{82}Se and ^{100}Mo is expected, making more solid the foundations for the background budget of the next-generation CUPID experiment. Relying on the excellent data reconstruction, we measure the two-neutrino double ß-decay half-life of ^{82}Se with unprecedented accuracy: T_{1/2}^{2ν}=[8.69±0.05(stat)_{-0.06}^{+0.09}(syst)]×10^{19} yr.

2.
Phys Rev Lett ; 129(11): 111801, 2022 Sep 09.
Article in English | MEDLINE | ID: mdl-36154394

ABSTRACT

CUPID-0, an array of Zn^{82}Se cryogenic calorimeters, was the first medium-scale demonstrator of the scintillating bolometers' technology. The first project phase (March 2017-December 2018) allowed the most stringent limit on the neutrinoless double beta decay half-life of the isotope of interest, ^{82}Se, to be set. After a six month long detector upgrade, CUPID-0 began its second and last phase (June 2019-February 2020). In this Letter, we describe the search for neutrinoless double beta decay of ^{82}Se with a total exposure (phase I+II) of 8.82 kg yr^{-1} of isotope. We set a limit on the half-life of ^{82}Se to the ground state of ^{82}Kr of T_{1/2}^{0ν}(^{82}Se)>4.6×10^{24} yr (90% credible interval), corresponding to an effective Majorana neutrino mass m_{ßß}<(263-545) meV. We also set the most stringent lower limits on the neutrinoless decays of ^{82}Se to the 0_{1}^{+}, 2_{1}^{+}, and 2_{2}^{+} excited states of ^{82}Kr, finding 1.8×10^{23} yr, 3.0×10^{23} yr, and 3.2×10^{23} yr (90% credible interval) respectively.

3.
Eur Phys J C Part Fields ; 81(8): 722, 2021.
Article in English | MEDLINE | ID: mdl-34720725

ABSTRACT

Localization and modeling of radioactive contaminations is a challenge that ultra-low background experiments are constantly facing. These are fundamental steps both to extract scientific results and to further reduce the background of the detectors. Here we present an innovative technique based on the analysis of α - α delayed coincidences in 232 Th and 238 U decay chains, developed to investigate the contaminations of the ZnSe crystals in the CUPID-0 experiment. This method allows to disentangle surface and bulk contaminations of the detectors relying on the different probability to tag delayed coincidences as function of the α decay position.

4.
Nat Commun ; 12(1): 2733, 2021 May 12.
Article in English | MEDLINE | ID: mdl-33980835

ABSTRACT

As quantum coherence times of superconducting circuits have increased from nanoseconds to hundreds of microseconds, they are currently one of the leading platforms for quantum information processing. However, coherence needs to further improve by orders of magnitude to reduce the prohibitive hardware overhead of current error correction schemes. Reaching this goal hinges on reducing the density of broken Cooper pairs, so-called quasiparticles. Here, we show that environmental radioactivity is a significant source of nonequilibrium quasiparticles. Moreover, ionizing radiation introduces time-correlated quasiparticle bursts in resonators on the same chip, further complicating quantum error correction. Operating in a deep-underground lead-shielded cryostat decreases the quasiparticle burst rate by a factor thirty and reduces dissipation up to a factor four, showcasing the importance of radiation abatement in future solid-state quantum hardware.

5.
Phys Rev Lett ; 124(16): 163604, 2020 Apr 24.
Article in English | MEDLINE | ID: mdl-32383959

ABSTRACT

We demonstrate a new mechanical transduction platform for individual spin qubits. In our approach, single micromagnets are trapped using a type-II superconductor in proximity of spin qubits, enabling direct magnetic coupling between the two systems. Controlling the distance between the magnet and the superconductor during cooldown, we demonstrate three-dimensional trapping with quality factors around 1×10^{6} and kHz trapping frequencies. We further exploit the large magnetic moment to mass ratio of this mechanical oscillator to couple its motion to the spin degrees of freedom of an individual nitrogen vacancy center in diamond. Our approach provides a new path towards interfacing individual spin qubits with mechanical motion for testing quantum mechanics with mesoscopic objects, realization of quantum networks, and ultrasensitive metrology.

6.
Phys Rev Lett ; 123(3): 032501, 2019 Jul 19.
Article in English | MEDLINE | ID: mdl-31386478

ABSTRACT

CUPID-0 is the first pilot experiment of CUPID, a next-generation project for the measurement of neutrinoless double beta decay (0νDBD) with scintillating bolometers. The detector, consisting of 24 enriched and 2 natural ZnSe crystals, has been taking data at Laboratori Nazionali del Gran Sasso from June 2017 to December 2018, collecting a ^{82}Se exposure of 5.29 kg×yr. In this Letter we present the phase-I results in the search for 0νDBD. We demonstrate that the technology implemented by CUPID-0 allows us to reach the lowest background for calorimetric experiments: (3.5_{-0.9}^{+1.0})×10^{-3} counts/(keV kg yr). Monitoring 3.88×10^{25} ^{82}Se nuclei×yr we reach a 90% credible interval median sensitivity of T_{1/2}^{0ν}>5.0×10^{24} yr and set the most stringent limit on the half-life of ^{82}Se 0νDBD: T_{1/2}^{0ν}>3.5×10^{24} yr (90% credible interval), corresponding to m_{ßß}<(311-638) meV depending on the nuclear matrix element calculations.

7.
Phys Rev Lett ; 123(26): 262501, 2019 Dec 31.
Article in English | MEDLINE | ID: mdl-31951429

ABSTRACT

We report on the measurement of the two-neutrino double-ß decay of ^{82}Se performed for the first time with cryogenic calorimeters, in the framework of the CUPID-0 experiment. With an exposure of 9.95 kg yr of Zn^{82}Se, we determine the two-neutrino double-ß decay half-life of ^{82}Se with an unprecedented precision level, T_{1/2}^{2ν}=[8.60±0.03(stat) _{-0.13}^{+0.19}(syst)]×10^{19} yr. The very high signal-to-background ratio, along with the detailed reconstruction of the background sources allowed us to identify the single state dominance as the underlying mechanism of such a process, demonstrating that the higher state dominance hypothesis is disfavored at the level of 5.5σ.

8.
Phys Rev Lett ; 120(23): 232502, 2018 Jun 08.
Article in English | MEDLINE | ID: mdl-29932707

ABSTRACT

We report the result of the search for neutrinoless double beta decay of ^{82}Se obtained with CUPID-0, the first large array of scintillating Zn^{82}Se cryogenic calorimeters implementing particle identification. We observe no signal in a 1.83 kg yr ^{82}Se exposure, and we set the most stringent lower limit on the 0νßß ^{82}Se half-life T_{1/2}^{0ν}>2.4×10^{24} yr (90% credible interval), which corresponds to an effective Majorana neutrino mass m_{ßß}<(376-770) meV depending on the nuclear matrix element calculations. The heat-light readout provides a powerful tool for the rejection of α particles and allows us to suppress the background in the region of interest down to (3.6_{-1.4}^{+1.9})×10^{-3} counts/(keV kg yr), an unprecedented level for this technique.

10.
Eur Phys J C Part Fields ; 78(11): 888, 2018.
Article in English | MEDLINE | ID: mdl-30881205

ABSTRACT

The CUPID-0 experiment searches for double beta decay using cryogenic calorimeters with double (heat and light) read-out. The detector, consisting of 24 ZnSe crystals 95 % enriched in 82 Se and two natural ZnSe crystals, started data-taking in 2017 at Laboratori Nazionali del Gran Sasso. We present the search for the neutrino-less double beta decay of 82 Se into the 0 1 + , 2 1 + and 2 2 + excited states of 82 Kr with an exposure of 5.74 kg · yr (2.24 × 10 25  emitters · yr). We found no evidence of the decays and set the most stringent limits on the widths of these processes: Γ ( 82 Se → 82 Kr 0 1 + )8.55 × 10 - 24  yr - 1 , Γ ( 82 Se → 82 Kr 2 1 + ) < 6.25 × 10 - 24  yr - 1 , Γ ( 82 Se → 82 Kr 2 2 + )8.25 × 10 - 24  yr - 1 (90 % credible interval).

11.
Eur Phys J C Part Fields ; 78(9): 734, 2018.
Article in English | MEDLINE | ID: mdl-30839752

ABSTRACT

The suppression of spurious events in the region of interest for neutrinoless double beta decay will play a major role in next generation experiments. The background of detectors based on the technology of cryogenic calorimeters is expected to be dominated by α particles, that could be disentangled from double beta decay signals by exploiting the difference in the emission of the scintillation light. CUPID-0, an array of enriched Zn 82 Se scintillating calorimeters, is the first large mass demonstrator of this technology. The detector started data-taking in 2017 at the Laboratori Nazionali del Gran Sasso with the aim of proving that dual read-out of light and heat allows for an efficient suppression of the α background. In this paper we describe the software tools we developed for the analysis of scintillating calorimeters and we demonstrate that this technology allows to reach an unprecedented background for cryogenic calorimeters.

12.
Eur Phys J C Part Fields ; 78(5): 428, 2018.
Article in English | MEDLINE | ID: mdl-30996670

ABSTRACT

The CUPID-0 detector hosted at the Laboratori Nazionali del Gran Sasso, Italy, is the first large array of enriched scintillating cryogenic detectors for the investigation of 82 Se neutrinoless double-beta decay ( 0 ν ß ß ). CUPID-0 aims at measuring a background index in the region of interest (RoI) for 0 ν ß ß at the level of 10 - 3  counts/(keV kg years), the lowest value ever measured using cryogenic detectors. CUPID-0 operates an array of Zn 82 Se scintillating bolometers coupled with bolometric light detectors, with a state of the art technology for background suppression and thorough protocols and procedures for the detector preparation and construction. In this paper, the different phases of the detector design and construction will be presented, from the material selection (for the absorber production) to the new and innovative detector structure. The successful construction of the detector lead to promising preliminary detector performance which is discussed here.

13.
Phys Rev Lett ; 119(16): 167202, 2017 Oct 20.
Article in English | MEDLINE | ID: mdl-29099212

ABSTRACT

We theoretically show that, despite Earnshaw's theorem, a nonrotating single magnetic domain nanoparticle can be stably levitated in an external static magnetic field. The stabilization relies on the quantum spin origin of magnetization, namely, the gyromagnetic effect. We predict the existence of two stable phases related to the Einstein-de Haas effect and the Larmor precession. At a stable point, we derive a quadratic Hamiltonian that describes the quantum fluctuations of the degrees of freedom of the system. We show that, in the absence of thermal fluctuations, the quantum state of the nanomagnet at the equilibrium point contains entanglement and squeezing.

14.
Eur Phys J C Part Fields ; 76(7): 364, 2016.
Article in English | MEDLINE | ID: mdl-28280442

ABSTRACT

The R&D activity performed during the last years proved the potential of ZnSe scintillating bolometers to the search for neutrino-less double beta decay, motivating the realization of the first large-mass experiment based on this technology: CUPID-0. The isotopic enrichment in [Formula: see text]Se, the Zn[Formula: see text]Se crystals growth, as well as the light detectors production have been accomplished, and the experiment is now in construction at Laboratori Nazionali del Gran Sasso (Italy). In this paper we present the results obtained testing the first three Zn[Formula: see text]Se crystals operated as scintillating bolometers, and we prove that their performance in terms of energy resolution, background rejection capability and intrinsic radio-purity complies with the requirements of CUPID-0.

15.
Article in English | MEDLINE | ID: mdl-26705394

ABSTRACT

The LUCIFER project aims at deploying the first array of enriched scintillating bolometers for the investigation of neutrinoless double-beta decay of [Formula: see text]Se. The matrix which embeds the source is an array of ZnSe crystals, where enriched [Formula: see text]Se is used as decay isotope. The radiopurity of the initial components employed for manufacturing crystals, that can be operated as bolometers, is crucial for achieving a null background level in the region of interest for double-beta decay investigations. In this work, we evaluated the radioactive content in 2.5 kg of 96.3 % enriched [Formula: see text]Se metal, measured with a high-purity germanium detector at the Gran Sasso deep underground laboratory. The limits on internal contaminations of primordial decay chain elements of [Formula: see text]Th, [Formula: see text]U and [Formula: see text]U are respectively: [Formula: see text]61, [Formula: see text]110 and [Formula: see text]74 [Formula: see text]Bq/kg at 90 % C.L. The extremely low-background conditions in which the measurement was carried out and the high radiopurity of the [Formula: see text]Se allowed us to establish the most stringent lower limits on the half-lives of the double-beta decay of [Formula: see text]Se to 0[Formula: see text], 2[Formula: see text] and 2[Formula: see text] excited states of [Formula: see text]Kr of 3.4[Formula: see text]10[Formula: see text], 1.3[Formula: see text]10[Formula: see text] and 1.0[Formula: see text]10[Formula: see text] y, respectively, with a 90 % C.L.

16.
Eur Phys J C Part Fields ; 75(1): 12, 2015.
Article in English | MEDLINE | ID: mdl-25983645

ABSTRACT

CUORE, an array of 988 TeO[Formula: see text] bolometers, is about to be one of the most sensitive experiments searching for neutrinoless double-beta decay. Its sensitivity could be further improved by removing the background from [Formula: see text] radioactivity. A few years ago it was pointed out that the signal from [Formula: see text]s can be tagged by detecting the emitted Cherenkov light, which is not produced by [Formula: see text]s. In this paper we confirm this possibility. For the first time we measured the Cherenkov light emitted by a CUORE crystal, and found it to be 100 eV at the [Formula: see text]-value of the decay. To completely reject the [Formula: see text] background, we compute that one needs light detectors with baseline noise below 20 eV RMS, a value which is 3-4 times smaller than the average noise of the bolometric light detectors we are using. We point out that an improved light detector technology must be developed to obtain TeO[Formula: see text] bolometric experiments able to probe the inverted hierarchy of neutrino masses.

17.
J Thromb Thrombolysis ; 38(3): 275-84, 2014 Oct.
Article in English | MEDLINE | ID: mdl-24880800

ABSTRACT

The REG2 Anticoagulation System consists of pegnivacogin, a subcutaneously administered aptamer factor IXa inhibitor, and its intravenous active control agent, anivamersen. Its effect on thrombin generation is unknown. A prospectively designed thrombin generation study was conducted within the phase 1 ascending dose study of REG2 to assess the effect of REG2 on thrombin generation kinetics. A total of 32 healthy volunteers were recruited into four cohorts of ascending dose pegnivacogin for the phase 1 study. In this pre-specified substudy, blood samples were drawn in the presence or absence of corn trypsin inhibitor at specified times within each dosing cohort. Thrombin generation was initiated with tissue factor and thrombin generation kinetics were measured using the Calibrated Automated Thrombogram (CAT). REG2 attenuated thrombin generation in a dose-dependent manner. All parameters of the CAT assay, except for lag time, showed a dose and concentration-dependent response to pegnivacogin [time to peak thrombin generation (PTm), endogenous thrombin potential, peak thrombin generation, and velocity index (VIx)]. Reversal of the effect of pegnivacogin with anivamersen demonstrated restoration of thrombin generation without rebound effect. This first-in-human study of the effect of the REG2 Anticoagulation System on thrombin generation demonstrates concentration-dependent suppression of thrombin generation that is reversible without rebound effect, as measured by the CAT assay.


Subject(s)
Anticoagulants/administration & dosage , Aptamers, Nucleotide/administration & dosage , Factor IXa/antagonists & inhibitors , Thrombin/metabolism , Adult , Dose-Response Relationship, Drug , Double-Blind Method , Female , Humans , Male , Prospective Studies , Thrombin Time/instrumentation , Thrombin Time/methods
18.
Ann Oncol ; 25(7): 1404-1410, 2014 Jul.
Article in English | MEDLINE | ID: mdl-24799461

ABSTRACT

BACKGROUND: Tumor regression after antiviral therapy (AT) is in favor of an etiological role of hepatitis C virus (HCV) in non-Hodgkin's B-cell lymphomas (NHL). PATIENTS AND METHODS: We carried out a cohort study of 704 consecutive HIV-negative, HCV-positive patients with indolent NHL diagnosed and treated from 1993 to 2009 in 39 centers of the Fondazione Italiana Linfomi; 134 patients were managed with AT for lymphoma control. RESULTS: For entire cohort, 5-year overall survival (OS) was 78% [95% confidence interval (CI): 74%-82%] and 5-year progression-free survival (PFS) was 48% (95% CI: 44%-53%). In multivariate analysis, the use of AT during the patients' life had positive impact on OS. Forty-four of the 100 patients treated with first-line AT achieved a complete remission (CR) and 33 a partial response (PR). HCV-RNA clearance was achieved in 80 patients and was related to lymphoma response. At a median follow-up of 3.6 years, 5-year PFS was 63% (95% CI: 50%-73%). CR + PR rate was 85% with AT as second-line treatment. CONCLUSION: AT produces HCV-RNA clearance and consequent tumor regression in most patients with HCV-related indolent NHL. AT used at any time is associated with improved OS. Consequently, AT can be considered an option for patients with indolent lymphomas who do not need immediate cytoreductive treatment.


Subject(s)
Antiviral Agents/therapeutic use , Hepatitis C/drug therapy , Lymphoma, B-Cell/drug therapy , Cohort Studies , Female , Hepatitis C/complications , Humans , Lymphoma, B-Cell/complications , Male , Middle Aged
19.
Ann Oncol ; 25(2): 442-7, 2014 Feb.
Article in English | MEDLINE | ID: mdl-24412823

ABSTRACT

BACKGROUND: [18F]fluorodeoxyglucose-positron emission tomography (PET) is emerging as a strong diagnostic and prognostic tool in follicular lymphoma (FL) patients. PATIENTS AND METHODS: In a subset analysis of the FOLL05 trial (NCT00774826), we investigated the prognostic role of post-induction PET (PI-PET) scan. Patients were eligible to this study if they had a PI-PET scan carried out within 3 months from the end of induction immunochemotherapy. Progression-free survival (PFS) was the primary study end point. RESULTS: A total of 202 patients were eligible and analysed for this study. The median age was 55 years (range 33-75). Overall, PI-PET was defined as positive in 49 (24%) patients. Conventional response assessment with CT scan was substantially modified by PET: 15% (22/145) of patients considered as having a complete response (CR) after CT were considered as having partial response (PR) after PI-PET and 53% (30/57) patients considered as having a PR after CT were considered as a CR after PI-PET. With a median follow-up of 34 months, the 3-year PFS was 66% and 35%, respectively, for patients with negative and positive PI-PET (P<0.001). At multivariate analysis, PI-PET (hazard ratio 2.57, 95% confidence interval 1.52-4.34, P<0.001) was independent of conventional response, FLIPI and treatment arm. Also, the prognostic role of PI-PET was maintained within each FLIPI risk group. CONCLUSIONS: In FL patients, PI-PET substantially modifies response assessment and is strongly predictive for the risk of progression. PET should be considered in further updates of response criteria.


Subject(s)
Antineoplastic Combined Chemotherapy Protocols/therapeutic use , Fluorodeoxyglucose F18 , Lymphoma, Follicular/diagnostic imaging , Radiopharmaceuticals , Disease-Free Survival , Female , Humans , Induction Chemotherapy , Kaplan-Meier Estimate , Lymphoma, Follicular/drug therapy , Lymphoma, Follicular/mortality , Male , Middle Aged , Multivariate Analysis , Positron-Emission Tomography , Prognosis , Proportional Hazards Models , Retrospective Studies , Treatment Outcome
20.
Ann Oncol ; 24(8): 2108-12, 2013 Aug.
Article in English | MEDLINE | ID: mdl-23585513

ABSTRACT

BACKGROUND: The role of [¹8F] fluorodeoxyglucose (FDG)-positron emission tomography (PET) in follicular lymphoma (FL) staging is not yet determined. PATIENTS AND METHODS: The aim of the present study was to investigate the role of PET in the initial staging of FL patients enrolled in the FOLL05-phase-III trial that compared first-line regimens (R-CVP, R-CHOP and R-FM). Patients should have undergone conventional staging and have available PET baseline to be included. RESULTS: A total of 142 patients were analysed. PET identified a higher number of nodal areas in 32% (46 of 142) of patients and more extranodal (EN) sites than computed tomography (CT) scan. Also, the Follicular Lymphoma International Prognostic Index (FLIPI) score increased in 18% (26 of 142) and decreased in 6% (9 of 142) of patients. Overall, the impact of PET on modifying the stage was highest in patients with limited stage. Actually, 62% (15 of 24) of cases with limited disease were upstaged with PET. CONCLUSIONS: The inclusion of PET among staging procedures makes the evaluation of patients with FL more accurate and has the potential to modify therapy decision and prognosis in a moderate proportion of patients. Further prospective clinical trials on FL should incorporate PET at different moments, and the therapeutic criteria to start therapy should be re-visited in the views of this new tool.


Subject(s)
Fluorodeoxyglucose F18 , Lymphoma, Follicular/diagnostic imaging , Neoplasm Staging/methods , Positron-Emission Tomography , Tomography, X-Ray Computed , Adult , Aged , Antineoplastic Combined Chemotherapy Protocols/therapeutic use , Cyclophosphamide/therapeutic use , Doxorubicin/therapeutic use , Female , Humans , Italy , Male , Middle Aged , Neoplasm Metastasis/diagnosis , Prednisone/therapeutic use , Prognosis , Radiopharmaceuticals , Retrospective Studies , Vincristine/therapeutic use
SELECTION OF CITATIONS
SEARCH DETAIL
...