Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Tech Vasc Interv Radiol ; 26(3): 100913, 2023 Sep.
Article in English | MEDLINE | ID: mdl-38071027

ABSTRACT

Contrast-enhanced ultrasound (CEUS) uses intravenously injected gas microbubbles as a pure blood pool contrast agent to demonstrate blood flow and tissue perfusion at a much higher sensitivity than color Doppler and power Doppler ultrasound. CEUS has gained traction in abdominal diagnostic imaging for improved lesion detection and characterization and a complementary problem-solving tool to CT and MRI. In addition to its diagnostic applications, CEUS has also proven useful for pre-procedure planning, procedure guidance, and post-procedure evaluation. This review provides a practical overview and guides to the application of CEUS in percutaneous, ultrasound-guided, needle-driven procedures, focusing on 2 common procedures, which illustrate the many benefits of CEUS- core needle biopsy (CNB) and percutaneous hepatic lesion ablation.


Subject(s)
Contrast Media , Liver Neoplasms , Humans , Ultrasonography/methods , Liver Neoplasms/pathology , Magnetic Resonance Imaging , Tomography, X-Ray Computed
2.
Radiol Case Rep ; 18(10): 3371-3375, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37502475

ABSTRACT

There are a wide range of benign and malignant pathologies that the radiologist may encounter in the adrenal glands and kidneys, often incidentally when imaging is performed for other indications. Many imaging modalities including CT, MR, and US are often used in an attempt to characterize these lesions. A definitive radiological diagnosis, however, is not always possible. This is at times due to atypical presentations of typical lesions which may be mistaken for more aggressive or concerning pathologic conditions. Adrenal lesions that do not demonstrate characteristic benign imaging features might require surgical excision. Similarly, cystic renal lesions that demonstrate nodular enhancement are concerning for Bosniak IV lesions and require surgical management. We report 3 cases in 3 different patients of incidentally discovered hematomas with peripheral enhancement, 2 involving the adrenal gland and 1 involving the kidney. All 3 of these histologically proven hematomas demonstrated similar radiological manifestations of peripheral nodular progressive enhancement, mimicking neoplastic conditions, and necessitating surgical removal.

3.
J Med Imaging (Bellingham) ; 7(5): 055502, 2020 Sep.
Article in English | MEDLINE | ID: mdl-37476354

ABSTRACT

Purpose: Foreign body aspiration is difficult to diagnose because many aspirated foreign bodies are low density or radiolucent. Digital radiographs (DR) are poor at detecting radiolucent foreign bodies. Digital tomosynthesis (DTS) has been shown to be ideally suited for applications where DR is insensitive and the increased dose from computed tomography (CT) is not justified. Our objective was to determine if DTS can be a practical alternative to DR and CT in the diagnosis of foreign body aspiration. Approach: A phantom approximating the densities of a pediatric chest was constructed. Radiolucent foreign bodies were placed in the airways. Seven pediatric radiologists assessed DTS and DR images with and without simulated breathing motion. Two rounds were performed with fixed exposure techniques and then automatic exposure control techniques. Interobserver agreement was evaluated using Fleiss' kappa. Results: DTS and DR images using fixed exposure techniques performed very poorly with accuracies of 42% to 60%. DTS with automatic exposure control techniques increased accuracy to 84% for a stationary phantom, but the accuracy dropped to 70% in a phantom with simulated motion. DTS outperformed DR, with DR accuracies of 60% and 63% for stationary simulations and motion, respectively. Interobserver agreement was poor with Fleiss' kappa of 0.476. Conclusion: DTS is superior to DR for radiolucent foreign body detection. However, the overall accuracy and interobserver agreement are likely too low for this modality to be clinically useful.

SELECTION OF CITATIONS
SEARCH DETAIL
...