Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Circ Cardiovasc Imaging ; 7(1): 43-51, 2014 Jan.
Article in English | MEDLINE | ID: mdl-24280729

ABSTRACT

BACKGROUND: Coronary lesions with a diameter narrowing ≥50% on visual computed tomographic coronary angiography (CTCA) are generally considered for referral to invasive coronary angiography. However, similar to invasive coronary angiography, visual CTCA is often inaccurate in detecting functionally significant coronary lesions. We sought to compare the diagnostic performance of quantitative CTCA with visual CTCA for the detection of functionally significant coronary lesions using fractional flow reserve (FFR) as the reference standard. METHODS AND RESULTS: CTCA and FFR measurements were obtained in 99 symptomatic patients. In total, 144 coronary lesions detected on CTCA were visually graded for stenosis severity. Quantitative CTCA measurements included lesion length, minimal area diameter, % area stenosis, minimal lumen diameter, % diameter stenosis, and plaque burden [(vessel area-lumen area)/vessel area×100]. Optimal cutoff values of CTCA-derived parameters were determined, and their diagnostic accuracy for the detection of flow-limiting coronary lesions (FFR≤0.80) was compared with visual CTCA. FFR was ≤0.80 in 54 of 144 (38%) coronary lesions. Optimal cutoff values to predict flow-limiting coronary lesion were 10 mm for lesion length, 1.8 mm2 for minimal area diameter, 73% for % area stenosis, 1.5 mm for minimal lumen diameter, 48% for % diameter stenosis, and 76% for plaque burden. No significant difference in sensitivity was found between visual CTCA and quantitative CTCA parameters (P>0.05). The specificity of visual CTCA (42%; 95% confidence interval [CI], 31%-54%) was lower than that of minimal area diameter (68%; 95% CI, 57%-77%; P=0.001), % area stenosis (76%; 95% CI, 65%-84%; P<0.001), minimal lumen diameter (67%; 95% CI, 55%-76%; P=0.001), % diameter stenosis (72%; 95% CI, 62%-80%; P<0.001), and plaque burden (63%; 95% CI, 52%-73%; P=0.004). The specificity of lesion length was comparable with that of visual CTCA. CONCLUSIONS: Quantitative CTCA improves the prediction of functionally significant coronary lesions compared with visual CTCA assessment but remains insufficient. Functional assessment is still required in lesions of moderate stenosis to accurately detect impaired FFR.


Subject(s)
Coronary Angiography/methods , Coronary Artery Disease/diagnostic imaging , Coronary Stenosis/diagnostic imaging , Coronary Vessels/diagnostic imaging , Multidetector Computed Tomography , Aged , Chi-Square Distribution , Coronary Artery Disease/physiopathology , Coronary Stenosis/physiopathology , Coronary Vessels/physiopathology , Female , Fractional Flow Reserve, Myocardial , Humans , Linear Models , Male , Middle Aged , Nonlinear Dynamics , Plaque, Atherosclerotic , Predictive Value of Tests , Retrospective Studies , Severity of Illness Index
2.
Echocardiography ; 30(5): 497-504, 2013 May.
Article in English | MEDLINE | ID: mdl-23305528

ABSTRACT

OBJECTIVES/BACKGROUND: Congenital aortic stenosis (AS) is the most common obstructive left heart lesion in the young adult population and often complicated by aortic dilatation. Our objective was to evaluate accuracy of aortic imaging with transthoracic echocardiography (TTE) compared with cardiac magnetic resonance (CMR). METHODS: Aortic diameters were measured at 4 levels by CMR and TTE. Agreement and concordance were assessed by Pearson's correlation and Bland-Altman analysis. RESULTS: Fifty-nine patients (age 33 ± 8 years; 66% male) with congenital AS and a bicuspid aortic valve (BAV) were included. Aortic diameters were generally smaller with TTE than with CMR. The best correlation was found at the level of the sinotubular junction (R(2) = 0.78) with a bias of 1.46 mm (limits of agreement: -5.47 to +8.39 mm). In patients with an aortic aneurysm >40 mm (n = 29) the correlation and agreement between TTE and CMR were found to be less good when compared with patients with normal aortic diameters, especially at the level of the proximal ascending aorta. The correlation and agreement between both imaging modalities were better in patients with type 1 BAV compared with type 2 BAV. Intra- and interobserver variability was smaller with CMR (1.8-5.9%) compared with TTE (6.9-15.0%). CONCLUSIONS: CMR was found to be superior to TTE for imaging of the aorta in patients with congenital AS, especially at the level of the proximal ascending aorta when an aortic aneurysm is present. Therefore, ideally CMR should be performed at least once to ensure an ascending aortic aneurysm is not missed.


Subject(s)
Aorta/diagnostic imaging , Aorta/pathology , Aortic Valve Stenosis/congenital , Aortic Valve Stenosis/diagnosis , Echocardiography/methods , Magnetic Resonance Imaging, Cine/methods , Adolescent , Adult , Aortic Aneurysm/diagnosis , Cohort Studies , Diagnostic Imaging/methods , Female , Humans , Male , Middle Aged , Mitral Valve/diagnostic imaging , Mitral Valve/pathology , Observer Variation , Prospective Studies , Reproducibility of Results , Risk Assessment , Young Adult
3.
World J Radiol ; 4(7): 302-10, 2012 Jul 28.
Article in English | MEDLINE | ID: mdl-22900131

ABSTRACT

AIM: To evaluate the role of diffusion-weighted imaging (DWI) in the detection of focal liver lesions (FLLs), using a conventional magnetic resonance imaging (MRI) protocol. METHODS: Fifty-two patients (22 males, average age 55.6 years, range: 25-82 years), studied using a 1.5 Tesla magnetic resonance scanner, were retrospectively analyzed; detection of FLLs was evaluated by considering the number of lesions observed with the following sequences: (1) respiratory-triggered diffusion-weighted single-shot echo-planar (DW SS-EP) sequences; (2) fat-suppressed fast spin-echo (fs-FSE) T2 weighted sequences; (3) steady-state free precession (SSFP) images; and (4) dynamic triphasic gadolinium-enhanced images, acquired with three-dimensional fast spoiled gradient-echo (3D FSPGR). Two radiologists independently reviewed the images: they were blinded to their respective reports. DW SS-EP sequences were compared to fs-FSE, SSFP and dynamic gadolinium-enhanced acquisitions using a t-test. Pairs were compared for the detection of: (1) all FLLs; (2) benign FLLs; (3) malignant FLLs; (4) metastases; and (5) hepatocellular carcinoma (HCC). RESULTS: Interobserver agreement was very good (weighted κ = 0.926, CI = 0.880-0.971); on the consensus reading, 277 FLLs were detected. In the comparison with fs-FSE, DW SS-EP sequences had a significantly higher score in the detection of all FLLs, benign FLLs, malignant FLLs and metastases; no statistical difference was observed in the detection of hepatocellular carcinoma (HCCs). In the comparison with SSFP sequences, DW SS-EP had significantly higher scores (P < 0.05) in the detection of all lesions, benign lesions, malignant lesions, metastases and HCC. All FLLs were better detected by dynamic 3D FSGR enhanced acquisition, with P = 0.0023 for reader 1 and P = 0.0086 for reader 2 in the comparison with DW SS-EP sequences; with reference to benign FLLs, DW SS-EP showed lower values than 3D FSPGR enhanced acquisition (P < 0.05). No statistical differences were observed in the detection of malignant lesions and metastases; considering HCCs, a very slight difference was reported by reader 1 (P = 0.049), whereas no difference was found by reader 2 (P = 0.06). CONCLUSION: In lesion detection, DWI had higher scores than T2 sequences; considering malignant FLLs, no statistical difference was observed between DWI and dynamic gadolinium images.

SELECTION OF CITATIONS
SEARCH DETAIL
...