1.
J Struct Biol ; 216(2): 108097, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38772448

ABSTRACT

Cryo-focussed ion beam (FIB)-milling is a powerful technique that opens up thick, cellular specimens to high-resolution structural analysis by electron cryotomography (cryo-ET). FIB-milled lamellae can be produced from cells on grids, or cut from thicker, high-pressure frozen specimens. However, these approaches can put geometrical constraints on the specimen that may be unhelpful, particularly when imaging structures within the cell that have a very defined orientation. For example, plunge frozen rod-shaped bacteria orient parallel to the plane of the grid, yet the Z-ring, a filamentous structure of the tubulin-like protein FtsZ and the key organiser of bacterial division, runs around the circumference of the cell such that it is perpendicular to the imaging plane. It is therefore difficult or impractical to image many complete rings with current technologies. To circumvent this problem, we have fabricated monolithic gold specimen supports with a regular array of cylindrical wells in a honeycomb geometry, which trap bacteria in a vertical orientation. These supports, which we call "honeycomb gold discs", replace standard EM grids and when combined with FIB-milling enable the production of lamellae containing cross-sections through cells. The resulting lamellae are more stable and resistant to breakage and charging than conventional lamellae. The design of the honeycomb discs can be modified according to need and so will also enable cryo-ET and cryo-EM imaging of other specimens in otherwise difficult to obtain orientations.


Subject(s)
Cryoelectron Microscopy , Electron Microscope Tomography , Gold , Cryoelectron Microscopy/methods , Gold/chemistry , Electron Microscope Tomography/methods , Escherichia coli/ultrastructure , Bacterial Proteins/chemistry , Bacterial Proteins/metabolism , Specimen Handling/methods
2.
Ultramicroscopy ; 256: 113883, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38008055

ABSTRACT

Determining the correct magnified pixel size of single-particle cryoEM micrographs is necessary to maximize resolution and enable accurate model building. Here we describe a simple and rapid procedure for determining the absolute magnification in an electron cryomicroscope to a precision of <0.5%. We show how to use the atomic lattice spacings of crystals of thin and readily available test specimens, such as gold, as an absolute reference to determine magnification for both room temperature and cryogenic imaging. We compare this method to other commonly used methods, and show that it provides comparable accuracy in spite of its simplicity. This magnification calibration method provides a definitive reference quantity for data analysis and processing, simplifies the combination of multiple datasets from different microscopes and detectors, and improves the accuracy with which the contrast transfer function of the microscope can be determined. We also provide an open source program, magCalEM, which can be used to accurately estimate the magnified pixel size of a cryoEM dataset ex post facto.

3.
Proc Natl Acad Sci U S A ; 120(49): e2312905120, 2023 Dec 05.
Article in English | MEDLINE | ID: mdl-38011573

ABSTRACT

Electron cryomicroscopy can, in principle, determine the structures of most biological molecules but is currently limited by access, specimen preparation difficulties, and cost. We describe a purpose-built instrument operating at 100 keV-including advances in electron optics, detection, and processing-that makes structure determination fast and simple at a fraction of current costs. The instrument attains its theoretical performance limits, allowing atomic resolution imaging of gold test specimens and biological molecular structure determination in hours. We demonstrate its capabilities by determining the structures of eleven different specimens, ranging in size from 140 kDa to 2 MDa, using a fraction of the data normally required. CryoEM with a microscope designed specifically for high-efficiency, on-the-spot imaging of biological molecules will expand structural biology to a wide range of previously intractable problems.

7.
Faraday Discuss ; 240(0): 277-302, 2022 11 08.
Article in English | MEDLINE | ID: mdl-35913392

ABSTRACT

Electron cryomicroscopy (cryoEM) has made great strides in the last decade, such that the atomic structure of most biological macromolecules can, at least in principle, be determined. Major technological advances - in electron imaging hardware, data analysis software, and cryogenic specimen preparation technology - continue at pace and contribute to the exponential growth in the number of atomic structures determined by cryoEM. It is now conceivable that within the next decade we will have structures for hundreds of thousands of unique protein and nucleic acid molecular complexes. But the answers to many important questions in biology would become obvious if we could identify these structures precisely inside cells with quantifiable error. In the context of an abundance of known structures, it is appropriate to consider the current state of electron cryomicroscopy for frozen specimens prepared directly from cells, and try to answer to the question of the title, both now and in the foreseeable future.


Subject(s)
Proteins , Software , Cryoelectron Microscopy/methods
8.
Ultramicroscopy ; 237: 113510, 2022 07.
Article in English | MEDLINE | ID: mdl-35367900

ABSTRACT

We investigate potential improvements in using electron cryomicroscopy to image thick specimens with high-resolution phase contrast imaging. In particular, using model experiments, electron scattering theory, Monte Carlo and multislice simulations, we determine the potential for improving electron cryomicrographs of proteins within a cell using chromatic aberration (Cc) correction. We show that inelastically scattered electrons lose a quantifiable amount of spatial coherence as they transit the specimen, yet can be used to enhance the signal from thick biological specimens (in the 1000 to 5000 Å range) provided they are imaged close to focus with an achromatic lens. This loss of information quantified here, which we call "specimen induced decoherence", is a fundamental limit on imaging biological molecules in situ. We further show that with foreseeable advances in transmission electron microscope technology, it should be possible to directly locate and uniquely identify sub-100 kDa proteins without the need for labels, in a vitrified specimen taken from a cell.


Subject(s)
Electrons , Cryoelectron Microscopy/methods , Microscopy, Electron , Microscopy, Phase-Contrast , Monte Carlo Method
9.
Ultramicroscopy ; 237: 113511, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35367902

ABSTRACT

A controversy exists as to whether the signal in a high resolution phase contrast electron micrograph of a particle in a thick specimen is the same irrespective of the particle's position along the beam axis. Different conceptions of inelastic scattering and its effects on wave interference have led to radically different expectations about the degree of phase contrast vs. depth. Here we examine the information available from bright field phase contrast images of small crystalline particles on the top or bottom of a thick support. The support is an aluminium foil which has strong plasmon resonances that cause a large proportion of the electron beam to lose energy in transit. Phase contrast micrographs of the atomic lattice of two ensembles of platinum particles were measured in an energy loss window corresponding to the first plasmon resonance. The signal measured for particles on top was equal to that for particles on the bottom of the foil to within a 99% confidence interval, and the measurements exclude other models of depth dependent phase contrast in the literature to >5σ. These observations are consistent with quantum theory which considers dynamical effects as independent of event sequence and is distinct from the "top-bottom effect" observed in amplitude contrast. We thus confirm that phase contrast using inelastically scattered electrons can be obtained equally well from particles within any layer of a thick specimen.

10.
Ultramicroscopy ; 237: 113512, 2022 07.
Article in English | MEDLINE | ID: mdl-35367901

ABSTRACT

We have studied the fading of electron diffraction spots from two-dimensional (2D) crystals of paraffin (C44H90), purple membrane (bacteriorhodopsin) and aquaporin 4 (AQP4) at stage temperatures between 4K and 100K. We observed that the diffraction spots at resolutions between 3 Å and 20 Å fade more slowly at liquid-helium temperatures compared to liquid-nitrogen temperatures, by a factor of between 1.2 and 1.8, depending on the specimens. If the reduction in the effective rate of radiation damage for 2D crystals at liquid-helium temperature (as measured by spot fading) can be shown to extend to macromolecular assemblies embedded in amorphous ice, this would suggest that valuable improvements to electron cryomicroscopy (cryoEM) of biological specimens could be made by reducing the temperature of the specimens under irradiation below what is obtainable using standard liquid-nitrogen cryostats.


Subject(s)
Helium , Nitrogen , Cryoelectron Microscopy/methods , Macromolecular Substances , Temperature
11.
Sci Adv ; 8(7): eabk3139, 2022 Feb 18.
Article in English | MEDLINE | ID: mdl-35171663

ABSTRACT

Phototrophic Gemmatimonadetes evolved the ability to use solar energy following horizontal transfer of photosynthesis-related genes from an ancient phototrophic proteobacterium. The electron cryo-microscopy structure of the Gemmatimonas phototrophica photosystem at 2.4 Å reveals a unique, double-ring complex. Two unique membrane-extrinsic polypeptides, RC-S and RC-U, hold the central type 2 reaction center (RC) within an inner 16-subunit light-harvesting 1 (LH1) ring, which is encircled by an outer 24-subunit antenna ring (LHh) that adds light-gathering capacity. Femtosecond kinetics reveal the flow of energy within the RC-dLH complex, from the outer LHh ring to LH1 and then to the RC. This structural and functional study shows that G. phototrophica has independently evolved its own compact, robust, and highly effective architecture for harvesting and trapping solar energy.

12.
Ultramicroscopy ; 232: 113396, 2022 01.
Article in English | MEDLINE | ID: mdl-34740028

ABSTRACT

We present a process for the manufacture of electron cryomicroscopy (cryoEM) specimen supports with an integrated foil-grid structure, using cryogenic vacuum evaporation (cryoEvap) and patterned electroplating on a silicon wafer substrate. The process is designed to produce a pattern of nanometre scale holes in a thin metal foil, which is attached to a pattern of micrometre scale grid bars that support it and allow handling of the millimetre scale device. All steps are carried out on a single 4 inch (100 mm) silicon wafer, without any need to handle individual grids during processing, and yield about 600 supports per wafer. The approach is generally applicable to the problem of creating a thin foil with nanometre scale features and a micrometre scale support structure; here it is used to make an all gold, HexAuFoil type design. It also allows for the addition of custom fiducial markers and patterns which aid in locating and identifying particular regions of a grid at several length scales: by eye, in an optical microscope, and in the electron microscope. Implemented at scale, this manufacturing process can supply ample grids to support the continued growth of cryoEM for determining the structure of biological molecules.


Subject(s)
Gold , Cryoelectron Microscopy
13.
Ultramicroscopy ; 222: 113213, 2021 03.
Article in English | MEDLINE | ID: mdl-33524638

ABSTRACT

The brightness of modern Schottky field-emission guns can produce electron beams that have very high spatial coherence, especially for the weak-illumination conditions that are used for single-particle electron cryo-microscopy in structural biology. Even so, many users have observed defocus-dependent Thon-ring fading that has led them to restrict their data collection strategy to imaging with relatively small defocus values. In this paper, we reproduce the observation of defocus-dependent Thon-ring fading and produce a quantitative analysis and clear explanation of its causes. We demonstrate that a major cause is the delocalization of high-resolution Fourier components outside the field of view of the camera. We also show that, to correctly characterize the phenomenon, it is important to make a correction for linear magnification anisotropy. Even when the anisotropy is quite small, it is present at all defocus values before circular averaging of the Thon rings, as is also true before merging data from particles in many orientations. Under the conditions used in this paper, which are typical of those used in single-particle electron cryomicroscopy, fading of the Thon rings due to source coherence is negligible. The principal conclusion is that much higher values of defocus can be used to record images than is currently thought to be possible, keeping in mind that the above-mentioned delocalization of Fourier components will ultimately become a limitation. This increased understanding should give electron microscopists the confidence to use higher amounts of defocus to allow, for example, better visibility of their particles and Ewald sphere correction.


Subject(s)
Carbon/chemistry , Cryoelectron Microscopy/methods , Image Processing, Computer-Assisted/methods , Algorithms , Anisotropy
14.
Proc Natl Acad Sci U S A ; 118(7)2021 02 16.
Article in English | MEDLINE | ID: mdl-33526596

ABSTRACT

The RNA polymerase inhibitor favipiravir is currently in clinical trials as a treatment for infection with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), despite limited information about the molecular basis for its activity. Here we report the structure of favipiravir ribonucleoside triphosphate (favipiravir-RTP) in complex with the SARS-CoV-2 RNA-dependent RNA polymerase (RdRp) bound to a template:primer RNA duplex, determined by electron cryomicroscopy (cryoEM) to a resolution of 2.5 Å. The structure shows clear evidence for the inhibitor at the catalytic site of the enzyme, and resolves the conformation of key side chains and ions surrounding the binding pocket. Polymerase activity assays indicate that the inhibitor is weakly incorporated into the RNA primer strand, and suppresses RNA replication in the presence of natural nucleotides. The structure reveals an unusual, nonproductive binding mode of favipiravir-RTP at the catalytic site of SARS-CoV-2 RdRp, which explains its low rate of incorporation into the RNA primer strand. Together, these findings inform current and future efforts to develop polymerase inhibitors for SARS coronaviruses.


Subject(s)
Amides/pharmacology , Coronavirus RNA-Dependent RNA Polymerase/metabolism , Enzyme Inhibitors/pharmacology , Pyrazines/pharmacology , SARS-CoV-2/ultrastructure , Amides/chemistry , Coronavirus RNA-Dependent RNA Polymerase/antagonists & inhibitors , Coronavirus RNA-Dependent RNA Polymerase/chemistry , Cryoelectron Microscopy/methods , Enzyme Inhibitors/chemistry , Pyrazines/chemistry , Ribonucleotides/chemistry , SARS-CoV-2/drug effects , SARS-CoV-2/enzymology , Single Molecule Imaging/methods
15.
Sci Adv ; 7(7)2021 02.
Article in English | MEDLINE | ID: mdl-33579696

ABSTRACT

We report the 2.4 Ångström resolution structure of the light-harvesting 2 (LH2) complex from Marichromatium (Mch.) purpuratum determined by cryogenic electron microscopy. The structure contains a heptameric ring that is unique among all known LH2 structures, explaining the unusual spectroscopic properties of this bacterial antenna complex. We identify two sets of distinct carotenoids in the structure and describe a network of energy transfer pathways from the carotenoids to bacteriochlorophyll a molecules. The geometry imposed by the heptameric ring controls the resonant coupling of the long-wavelength energy absorption band. Together, these details reveal key aspects of the assembly and oligomeric form of purple bacterial LH2 complexes that were previously inaccessible by any technique.

16.
Science ; 370(6513): 223-226, 2020 10 09.
Article in English | MEDLINE | ID: mdl-33033219

ABSTRACT

Most information loss in cryogenic electron microscopy (cryo-EM) stems from particle movement during imaging, which remains poorly understood. We show that this movement is caused by buckling and subsequent deformation of the suspended ice, with a threshold that depends directly on the shape of the frozen water layer set by the support foil. We describe a specimen support design that eliminates buckling and reduces electron beam-induced particle movement to less than 1 angstrom. The design allows precise foil tracking during imaging with high-speed detectors, thereby lessening demands on cryostage precision and stability. It includes a maximal density of holes, which increases throughput in automated cryo-EM without degrading data quality. Movement-free imaging allows extrapolation to a three-dimensional map of the specimen at zero electron exposure, before the onset of radiation damage.


Subject(s)
Cryoelectron Microscopy/methods , Freezing , Proteins/chemistry
17.
Nature ; 575(7781): 234-237, 2019 11.
Article in English | MEDLINE | ID: mdl-31666700

ABSTRACT

The Fanconi anaemia (FA) pathway repairs DNA damage caused by endogenous and chemotherapy-induced DNA crosslinks, and responds to replication stress1,2. Genetic inactivation of this pathway by mutation of genes encoding FA complementation group (FANC) proteins impairs development, prevents blood production and promotes cancer1,3. The key molecular step in the FA pathway is the monoubiquitination of a pseudosymmetric heterodimer of FANCD2-FANCI4,5 by the FA core complex-a megadalton multiprotein E3 ubiquitin ligase6,7. Monoubiquitinated FANCD2 then recruits additional protein factors to remove the DNA crosslink or to stabilize the stalled replication fork. A molecular structure of the FA core complex would explain how it acts to maintain genome stability. Here we reconstituted an active, recombinant FA core complex, and used cryo-electron microscopy and mass spectrometry to determine its structure. The FA core complex comprises two central dimers of the FANCB and FA-associated protein of 100 kDa (FAAP100) subunits, flanked by two copies of the RING finger subunit, FANCL. These two heterotrimers act as a scaffold to assemble the remaining five subunits, resulting in an extended asymmetric structure. Destabilization of the scaffold would disrupt the entire complex, resulting in a non-functional FA pathway. Thus, the structure provides a mechanistic basis for the low numbers of patients with mutations in FANCB, FANCL and FAAP100. Despite a lack of sequence homology, FANCB and FAAP100 adopt similar structures. The two FANCL subunits are in different conformations at opposite ends of the complex, suggesting that each FANCL has a distinct role. This structural and functional asymmetry of dimeric RING finger domains may be a general feature of E3 ligases. The cryo-electron microscopy structure of the FA core complex provides a foundation for a detailed understanding of its E3 ubiquitin ligase activity and DNA interstrand crosslink repair.


Subject(s)
Cryoelectron Microscopy , Fanconi Anemia Complementation Group Proteins/chemistry , Fanconi Anemia Complementation Group Proteins/ultrastructure , Multiprotein Complexes/chemistry , Multiprotein Complexes/ultrastructure , Protein Subunits/chemistry , Animals , Chickens , Fanconi Anemia/enzymology , Fanconi Anemia Complementation Group L Protein/chemistry , Fanconi Anemia Complementation Group L Protein/ultrastructure , Mass Spectrometry , Models, Molecular , Protein Domains , Protein Multimerization , Structure-Activity Relationship , Ubiquitination
18.
J Hosp Med ; 14(7): 436-440, 2019 07.
Article in English | MEDLINE | ID: mdl-31251165

ABSTRACT

BACKGROUND: As pediatric hospital medicine continues to grow, it is important to keep abreast of the current literature. This article provides a summary of six of the most impactful articles published in 2018. METHODS: The authors reviewed articles published between January 2018 and December 2018 for the 2019 Society of Hospital Medicine national conference presentation of Top Articles in Pediatric Hospital Medicine, where the top 10 articles of 2018 were presented. Six of the 10 articles are highlighted in this review based on article quality and their applicability to change practices in the hospital setting or prompt further research. RESULTS: Key findings from the articles include: multiple interventions aimed at providers can improve compliance with bronchiolitis guidelines; a developed calculator can improve testing for urinary tract infections in children aged 2-24 months; nonmedical costs of hospitalizations are underappreciated and disproportionately affect those with a lower socioeconomic status; a progress note template in an electronic health record can lead to higher quality and shorter notes; for febrile infants aged 60 days and younger, most blood and cerebrospinal fluid culture pathogens can be identified within 24 hours and nearly all by 36 hours; and the development of a high-value care tool can help to bring concepts of high-value care into family-centered rounds. CONCLUSION: The six selected articles highlight findings pertinent to pediatric hospital medicine.


Subject(s)
Child, Hospitalized , Hospital Medicine/trends , Hospitals, Pediatric/trends , Quality Improvement , Urinary Tract Infections/diagnosis , Bronchiolitis/therapy , Child, Preschool , Electronic Health Records/standards , Financing, Personal/economics , Humans , Infant , Socioeconomic Factors
19.
Proc Natl Acad Sci U S A ; 116(24): 11718-11724, 2019 06 11.
Article in English | MEDLINE | ID: mdl-31127045

ABSTRACT

With recent technological advances, the atomic resolution structure of any purified biomolecular complex can, in principle, be determined by single-particle electron cryomicroscopy (cryoEM). In practice, the primary barrier to structure determination is the preparation of a frozen specimen suitable for high-resolution imaging. To address this, we present a multifunctional specimen support for cryoEM, comprising large-crystal monolayer graphene suspended across the surface of an ultrastable gold specimen support. Using a low-energy plasma surface modification system, we tune the surface of this support to the specimen by patterning a range of covalent functionalizations across the graphene layer on a single grid. This support design reduces specimen movement during imaging, improves image quality, and allows high-resolution structure determination with a minimum of material and data.

20.
Ultramicroscopy ; 203: 125-131, 2019 08.
Article in English | MEDLINE | ID: mdl-30773415

ABSTRACT

We have measured the dependence on electron energy of elastic and inelastic scattering cross-sections from carbon, over the energy range that includes 100 keV to 300 keV. We also compared quantitatively the radiation damage to bacteriorhodopsin and paraffin (C44H90) at 100 keV and 300 keV by observing the fading of the diffraction spots from two-dimensional crystals as a function of electron fluence. The elastic cross-section is 2.01 - fold greater at 100 keV than at 300 keV, whereas the radiation damage increased by only 1.57. This implies that the amount of useful information from diffraction patterns or images of most biological structures should be 25% greater using 100 keV rather than 300 keV electrons. Using these measurements, we calculate the energy dependence of the available information per unit damage for a specimen of a particular thickness, which we call the "information coefficient." This allows us to determine the optimal energy for imaging a biological specimen of a given thickness. We find that for most single particle cryoEM specimens, 100 keV provides not only the highest potential for information per unit damage, but would also simplify the instrument while retaining the potential to reach high resolution with a minimum of data. These measurements will help guide the development and use of electron cryomicroscopes for biology.


Subject(s)
Carbon/chemistry , Bacteriorhodopsins/chemistry , Cryoelectron Microscopy/methods , Electrons , Microscopy, Electron/methods , Paraffin/chemistry , Scattering, Radiation