Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Molecules ; 25(23)2020 Nov 28.
Article in English | MEDLINE | ID: mdl-33260601

ABSTRACT

We report on a fiber-coupled, quartz-enhanced photoacoustic spectroscopy (QEPAS) near-IR sensor for sequential detection of methane (CH4 or C1) and ethane (C2H6 or C2) in air. With the aim of developing a lightweight, compact, low-power-consumption sensor suitable for unmanned aerial vehicles (UAVs)-empowered environmental monitoring, an all-fiber configuration was designed and realized. Two laser diodes emitting at 1653.7 nm and 1684 nm for CH4 and C2H6 detection, respectively, were fiber-combined and fiber-coupled to the collimator port of the acoustic detection module. No cross talk between methane and ethane QEPAS signal was observed, and the related peak signals were well resolved. The QEPAS sensor was calibrated using gas samples generated from certified concentrations of 1% CH4 in N2 and 1% C2H6 in N2. At a lock-in integration time of 100 ms, minimum detection limits of 0.76 ppm and 34 ppm for methane and ethane were achieved, respectively. The relaxation rate of CH4 in standard air has been investigated considering the effects of H2O, N2 and O2 molecules. No influence on the CH4 QEPAS signal is expected when the water vapor concentration level present in air varies in the range 0.6-3%.


Subject(s)
Environmental Monitoring/methods , Ethane/analysis , Methane/analysis , Photoacoustic Techniques/methods , Quartz/chemistry , Spectroscopy, Near-Infrared/methods
2.
Opt Express ; 28(13): 19074-19084, 2020 Jun 22.
Article in English | MEDLINE | ID: mdl-32672192

ABSTRACT

We report on a study of light-induced thermo-elastic effects occurring in quartz tuning forks (QTFs) when exploited as near-infrared light detectors in a tunable diode laser absorption spectroscopy sensor setup. Our analysis showed that when the residual laser beam transmitted by the absorption cell is focused on the QTF surface area where the maximum strain field occurs, the QTF signal-to-noise ratio (SNR) is proportional to the strain itself and to the QTF accumulation time. The SNR was also evaluated when the pressure surrounding the QTF was lowered from 700 Torr to 5 Torr, resulting in an enhancement factor of ∽4 at the lowest pressure. At 5 torr, the QTF employed as light detector showed an SNR ∽6.5 times higher than that obtained by using a commercially available amplified photodetector.

SELECTION OF CITATIONS
SEARCH DETAIL
...