Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Language
Publication year range
1.
Chin J Traumatol ; 19(4): 213-6, 2016 Aug 01.
Article in English | MEDLINE | ID: mdl-27578377

ABSTRACT

PURPOSE: Literature suggests that the lower modulus of elasticity of titanium makes it ideal for use in children compared with stainless steel. Better fracture stability was observed in association with titanium nails on torsional and axial compression testing. However, stainless steel nails are stiffer than titanium counterparts, which may provide a rigid construct when fixing paediatric femoral shaft fractures. Complications have been observed more frequently by various researchers when titanium nails are used for fracture fixation in patients with increasing age or weight. The concept of this study was to compare the functional outcome after internal fixation with titanium elastic nail system and stainless steel elastic nail system in paediatric femoral shaft fractures. METHODS: The study was conducted on 34 patients admitted in the department of orthopaedics, LLRM Medical College & SVBP Hospital, Meerut, India from January 2013 to August 2014. We included patients aged 5-12 years with fracture of the femoral shaft, excluding compound fractures, pathological fractures and other lower limb fractures. Patients were treated by titanium (n=17) or stainless steel (n=17) elastic nail system and followed up for one year. The clinical parameters like range of motion at hip and knee joints, time to full weight bearing on the operated limb and radiological parameters like time to union were compared between two groups. A special note was made of intra- and post-operative complications. Functional outcomes were analysed according to Flynn criteria. RESULTS: Based on the Flynn criteria, 59% of patients had excellent results, 41% had satisfactory results, and no one showed poor results. There was no clinically significant difference between the two groups with respect to time to union and full weight bearing. But the incidence of puncture of the opposite cortex while inserting the nail and trying to advance it through the diaphysis during operation is greatly different. Only one such case was observed in titanium group but five in stainless steel group. CONCLUSION: Majority of paediatric femoral shaft fractures are now treated operatively by elastic stable intramedullary nails. Operative intervention results in a shorter hospital stay and has economic and social benefits over conservative treatment. The cost of stainless steel nail is one third the cost of titanium nail. However, the clinico-radiological results are not significantly different between titanium and stainless steel nails at one year follow-up as observed by our study.


Subject(s)
Bone Nails , Femoral Fractures/surgery , Child , Child, Preschool , Female , Femoral Fractures/physiopathology , Humans , Male , Range of Motion, Articular , Stainless Steel , Titanium
2.
Chinese Journal of Traumatology ; (6): 213-216, 2016.
Article in English | WPRIM (Western Pacific) | ID: wpr-235745

ABSTRACT

<p><b>PURPOSE</b>Literature suggests that the lower modulus of elasticity of titanium makes it ideal for use in children compared with stainless steel. Better fracture stability was observed in association with titanium nails on torsional and axial compression testing. However, stainless steel nails are stiffer than titanium counterparts, which may provide a rigid construct when fixing paediatric femoral shaft fractures. Complications have been observed more frequently by various researchers when titanium nails are used for fracture fixation in patients with increasing age or weight. The concept of this study was to compare the functional outcome after internal fixation with titanium elastic nail system and stainless steel elastic nail system in paediatric femoral shaft fractures.</p><p><b>METHODS</b>The study was conducted on 34 patients admitted in the department of orthopaedics, LLRM Medical College & SVBP Hospital, Meerut, India from January 2013 to August 2014. We included patients aged 5-12 years with fracture of the femoral shaft, excluding compound fractures, pathological fractures and other lower limb fractures. Patients were treated by titanium (n=17) or stainless steel (n=17) elastic nail system and followed up for one year. The clinical parameters like range of motion at hip and knee joints, time to full weight bearing on the operated limb and radiological parameters like time to union were compared between two groups. A special note was made of intra- and post-operative complications. Functional outcomes were analysed according to Flynn criteria.</p><p><b>RESULTS</b>Based on the Flynn criteria, 59% of patients had excellent results, 41% had satisfactory results, and no one showed poor results. There was no clinically significant difference between the two groups with respect to time to union and full weight bearing. But the incidence of puncture of the opposite cortex while inserting the nail and trying to advance it through the diaphysis during operation is greatly different. Only one such case was observed in titanium group but five in stainless steel group.</p><p><b>CONCLUSION</b>Majority of paediatric femoral shaft fractures are now treated operatively by elastic stable intramedullary nails. Operative intervention results in a shorter hospital stay and has economic and social benefits over conservative treatment. The cost of stainless steel nail is one third the cost of titanium nail. However, the clinico-radiological results are not significantly different between titanium and stainless steel nails at one year follow-up as observed by our study.</p>


Subject(s)
Child , Child, Preschool , Female , Humans , Male , Bone Nails , Femoral Fractures , General Surgery , Range of Motion, Articular , Stainless Steel , Titanium
3.
J Parasit Dis ; 34(2): 63-7, 2010 Oct.
Article in English | MEDLINE | ID: mdl-21966122

ABSTRACT

Since the beginning of the AIDS pandemic, opportunistic infections have been recognized as common complications of HIV infection. Enteric protozoan parasitic infections are one of the leading causes of morbidity and mortality in HIV infected patients. The present study is, therefore, aimed to determine the prevalence of these parasites and study their association with immune status in HIV patients with emphasis on the correlation between various diagnostic techniques to give an accurate diagnosis to avoid empirical treatment. This prospective study, carried out between November 2009 and May 2010 included all HIV seropositive patients presenting with diarrhea to the ART center. A total of 64 stool samples were analyzed by wet mount examination, three different staining techniques, and antigen detection by ELISA for various enteric protozoan infections. Total prevalence of enteric protozoan parasites was 30%. Among the total cases, Cryptosporidium was seen in 12% cases followed by Giardia, E. histolytica and Isospora belli. The maximum diagnostic yield for coccidian parasites was with safranin-methylene blue staining technique. Parasitic burden contributes towards early morbidity in HIV infection. This study provides important information about prevalence of intestinal protozoan parasites in HIV infection. A combination of procedures should be carried out for the screening of stool specimens of HIV patients for better diagnosis and management.

SELECTION OF CITATIONS
SEARCH DETAIL
...