Results 1 - 20 de 68
Filter
1.
Magn Reson Med ; 65(5): 1228-33, 2011 May.
Article in English | MEDLINE | ID: mdl-21500253

ABSTRACT

Fast chemical shift imaging (CSI) techniques are advantageous in metabolic imaging of hyperpolarized compounds due to the limited duration of the signal amplification. At the same time, reducing the acquisition time in hyperpolarized imaging does not necessarily lead to the conventional penalty in signal-to-noise ratio that occurs in imaging at thermal equilibrium polarization levels. Here a high-performance gradient insert was used in combination with undersampled spiral CSI to increase either the imaging speed or the spatial resolution of hyperpolarized (13)C metabolic imaging on a clinical 3T MR scanner. Both a single-shot sequence with a total acquisition time of 125 ms and a three-shot sequence with a nominal in-plane resolution of 1.5 mm were implemented. The k-space trajectories were measured and then used during image reconstruction. The technique was applied to metabolic imaging of the rat brain in vivo after the injection of hyperpolarized [1-(13)C]-pyruvate. Dynamic imaging afforded the measurement of region-of-interest-specific time courses of pyruvate and its metabolic products, while imaging at high spatial resolution was used to better characterize the spatial distribution of the metabolite signals.


Subject(s)
Brain/metabolism , Magnetic Resonance Imaging/methods , Pyruvic Acid/metabolism , Algorithms , Animals , Carbon Isotopes/metabolism , Image Processing, Computer-Assisted , Magnetic Resonance Imaging/instrumentation , Phantoms, Imaging , Rats
2.
MAGMA ; 17(1): 12-27, 2004 Sep.
Article in English | MEDLINE | ID: mdl-15221661

ABSTRACT

High-speed switching of current in gradient coils within high magnetic field strength magnetic resonance imaging (MRI) scanners results in high acoustic sound pressure levels (SPL) in and around these machines. To characterize the vibration properties as well as the acoustic noise properties of the gradient coil, a finite-element (FE) model was developed using the dimensional design specifications of an available gradient-coil insert and the concentration of the copper windings in the coil. This FE model was then validated using experimentally collected vibration data. A computational acoustic noise model was then developed based on the validated FE model. The validation of the finite-element analysis results was done using experimental modal testing of the same gradient coil in a free-free state (no boundary constraints). Based on the validated FE model, boundary conditions (supports) were added to the model to simulate the operating condition when the gradient-coil insert is in place in an MRI machine. Vibration analysis results from the FE model were again validated through experimental vibration testing with the gradient-coil insert installed in the MRI scanner and excited using swept sinusoidal time waveforms. The simulation results from the computational acoustic noise model were also validated through experimental noise measurement from the gradient-coil insert in the MRI scanner using swept sinusoidal time waveform inputs. Comparisons show that the FE model predicts the vibration properties and the computational acoustic noise model predicts the noise characteristic properties extremely accurately.


Subject(s)
Acoustics , Magnetic Resonance Imaging/instrumentation , Magnetic Resonance Imaging/methods , Equipment Design , Finite Element Analysis , Models, Theoretical , Noise , Software , Vibration
3.
Med Phys ; 29(5): 727-35, 2002 May.
Article in English | MEDLINE | ID: mdl-12033569

ABSTRACT

We describe a method to extract data from multispectral MR exams of patients with Multiple Sclerosis (MS). The technique produces images of "spectral phase" (SP) relative to a reference tissue. SP images allow retrospective suppression of signal in the reference tissue, while maintaining high spatial resolution. Image quality in SP images was determined from MR exams of 5 MS patients selected at random from a clinical trial underway at our institute. Exams consisting of proton density weighted (PDw), T2 weighted (T2w), T1 weighted (T1w), and gadolinium-DTPA enhanced T1w (GAD) images were acquired from each patient. The MR exams were corrected for intensity nonuniformity, then filtered with an algorithm based upon anisotropic diffusion, to reduce noise. Principal component (PC) images and SP images relative to cerebrospinal fluid (SP(CSF)), normal appearing white matter (SP(NAWM)), gray matter (SP(GM)), and temporalis muscle (SP(MUS)) were then calculated. Contrast between tissues and MS lesions in the MR and derived images was then determined by measuring the signal-difference-to-noise ratio (dSNR) between tissues. Our new SP images provided better tissue contrast than the original MR, filtered MR, and PC images. Contrast improved between CSF and NAWM (from 19.5 to 56), CSF and GM (from 15 to 36), GM and NAWM (from 8 to 14), MS lesions and CSF (from 16 to 35), and between MS lesions and NAWM (from 24 to 47). (Maximum contrast in the original MR images compared to maximum contrast in the SP images.) The additional contrast in SP images may aid the quantification and analysis of lesion activity in MR exams of MS patients.


Subject(s)
Image Processing, Computer-Assisted/statistics & numerical data , Magnetic Resonance Imaging/statistics & numerical data , Multiple Sclerosis, Relapsing-Remitting/diagnosis , Adult , Anisotropy , Contrast Media , Female , Gadolinium DTPA , Humans , Middle Aged , Multiple Sclerosis, Relapsing-Remitting/pathology , Principal Component Analysis
4.
Magn Reson Med ; 46(2): 299-304, 2001 Aug.
Article in English | MEDLINE | ID: mdl-11477633

ABSTRACT

Black blood MRI has become a popular technique for measuring arterial wall area as an indicator of plaque size. Computer-assisted techniques for segmenting vessel boundaries have been developed to increase measurement precision. In this study, the carotid arteries of four normal subjects were imaged at seven different fields of view (FOVs), keeping all other imaging parameters fixed, to determine whether spatial resolution could be increased at the expense of image quality without sacrificing precision. Wall areas were measured via computer-assisted segmentation of the vessel boundaries performed repeatedly by two operators. Analysis of variance (ANOVA) demonstrated that the variability of wall area measurements was below 1.5 mm(2) for in-plane spatial resolutions between 0.22 mm and 0.37 mm. An inverse relationship between operator variability and the signal difference-to-noise ratio (SDNR) demonstrated that semi-automatic segmentation of the wall boundaries was robust for SDNR >3, defining a criterion above which subjective image quality can be degraded without an appreciable loss of information content. Our study also suggested that spatial resolutions higher than 0.3 mm may be required to quantify normal wall areas to within 10% accuracy, but that the reduced SNR associated with the higher resolution may be tolerated by semi-automated wall segmentation without an appreciable loss of precision.


Subject(s)
Carotid Arteries/anatomy & histology , Magnetic Resonance Imaging/methods , Adult , Algorithms , Analysis of Variance , Arteriosclerosis/diagnosis , Blood , Female , Humans , Image Processing, Computer-Assisted , Male
5.
Magn Reson Med ; 46(2): 386-94, 2001 Aug.
Article in English | MEDLINE | ID: mdl-11477644

ABSTRACT

Gradient coil magnetostimulation thresholds were measured in a group of 20 volunteers in both a whole-body gradient coil and a head/neck gradient coil. Both coils were operated using both x and y axes simultaneously (xy oblique mode). The waveform applied was a 64-lobe trapezoidal train with 1-ms flat-tops and varying rise times. Thresholds were based on the subjects' perception of stimulation, and painful sensations were not elicited. Thresholds were expressed in terms of the total gradient excursion required to cause stimulation as a function of the duration of the excursion. Thresholds for each subject were fit to a linear model, and values for the threshold curve slope (SR(min)) and vertical axis intercept (DeltaG(min)) were extracted. For the body coil, the mean values were: SR(min) = 62.2 mT/m/ms, DeltaG(min) = 44.4 mT/m. For the head/neck coil, the mean values were: SR(min) = 87.3 mT/m/ms, DeltaG(min) = 78.9 mT/m. These curve parameters were combined with calculated values for the induced electric field as a function of position within the coil to yield the tissue specific parameters E(r) (electric field rheobase) and tau(c) (chronaxie). For tissue stimulated within the body coil, the mean values were: E(r) = 1.8 V/m, tau(c) = 770 micros. For tissue stimulated within the head/neck coil, the mean values were: E(r) = 1.3 V/m, tau(c) = 1100 micros. Scalar potential contributions were not included in the calculation of induced electric fields. The mean threshold curves were combined with the gradient system performance curves to produce operational limit curves. The operational limit curves for the head/neck coil system were verified to be higher than those of the whole-body coil; however, the head/neck system was also found to be physiologically limited over a greater range of its operation than was the body coil. Subject thresholds between the two coils were not well correlated.


Subject(s)
Magnetic Resonance Imaging/instrumentation , Sensation/physiology , Female , Humans , Magnetic Resonance Imaging/adverse effects , Male , Pain Threshold/physiology
6.
Med Phys ; 28(6): 1098-107, 2001 Jun.
Article in English | MEDLINE | ID: mdl-11439479

ABSTRACT

Black blood magnetic resonance imaging (MRI) has become a popular technique for imaging the artery wall in vivo. Its noninvasiveness and high resolution make it ideal for studying the progression of early atherosclerosis in normal volunteers or asymptomatic patients with mild disease. However, the operator variability inherent in the manual measurement of vessel wall area from MR images hinders the reliable detection of relatively small changes in the artery wall over time. In this paper we present a semi-automatic method for segmenting the inner and outer boundary of the artery wall, and evaluate its operator variability using analysis of variance (ANOVA). In our approach, a discrete dynamic contour is approximately initialized by an operator, deformed to the inner boundary, dilated, and then deformed to the outer boundary. A group of four operators performed repeated measurements on 12 images from normal human subjects using both our semiautomatic technique and a manual approach. Results from the ANOVA indicate that the inter-operator standard error of measurement (SEM) of total wall area decreased from 3.254 mm2 (manual) to 1.293 mm2 (semi-automatic), and the intra-operator SEM decreased from 3.005 mm2 to 0.958 mm2. Operator reliability coefficients increased from less than 69% to more than 91% (inter-operator) and 95% (intra-operator). The minimum detectable change in wall area improved from more than 8.32 mm2 (intra-operator, manual) to less than 3.59 mm2 (inter-operator, semi-automatic), suggesting that it is better to have multiple operators measure wall area with our semi-automatic technique than to have a single operator make repeated measurements manually. Similar improvements in wall thickness and lumen radius measurements were also recorded. Since the semi-automatic technique has effectively ruled out the effect of the operator on these measurements, it may be possible to use such techniques to expand prospective studies of atherogenesis to multiple centers so as to increase access to real patient data without sacrificing reliability.


Subject(s)
Arteries/anatomy & histology , Image Interpretation, Computer-Assisted , Magnetic Resonance Imaging/methods , Adult , Algorithms , Analysis of Variance , Arteriosclerosis/diagnosis , Arteriosclerosis/etiology , Biophysical Phenomena , Biophysics , Blood , Female , Humans , Magnetic Resonance Imaging/statistics & numerical data , Male , Prospective Studies
7.
Top Magn Reson Imaging ; 12(3): 205-17, 2001 Jun.
Article in English | MEDLINE | ID: mdl-11432578

ABSTRACT

Magnetic resonance imaging (MRI) of carotid plaque has undergone significant improvements in the last decade. Early studies utilizing ex vivo specimens and spin-echo or fast spin-echo imaging led to the conclusion that T2 weighting is the best single contrast to characterize carotid plaque morphology. On these images, the fibrous plaque appears bright and the lipid core is dark; thrombus can have variable intensity. There can be an overlap in T2-weighted signal intensities among the various plaque components, which can be partially offset by the use of multispectral analysis of multiple contrast images. With improvements in coil design, sequence design, and main field and gradient capabilities, accurate in vivo differentiation and measurement of these various carotid plaque components should be possible in 3 to 5 years. Ex vivo and in vivo studies have yielded high-resolution measurements of the complex three-dimensional lumen geometry, which are being used to predict hemodynamic forces acting on the lumenal surface. Carotid plaque burden can be accurately measured in vivo today; ongoing longitudinal studies should lead to a better understanding of the relationship between plaque burden and the risk of thromboembolic complications, as well as the effect of diet and drug therapy in hyperlipidemic patients. With these developments in place or soon to be available, MRI of the diseased carotid artery wall may prove to be even more important than magnetic resonance angiography.


Subject(s)
Carotid Artery Diseases/pathology , Magnetic Resonance Imaging , Humans
8.
Magn Reson Med ; 45(5): 916-9, 2001 May.
Article in English | MEDLINE | ID: mdl-11323819

ABSTRACT

A simple linear formulation for magnetostimulation thresholds specific to MRI gradient coils is derived based on established hyperbolic electrostimulation strength vs. duration relations. Thresholds are derived in terms of the gradient excursion required to cause stimulation, and it is demonstrated that the threshold curve is a linear function of the gradient switching time. A parameter beta is introduced as being fundamental in the evaluation of gradient coil stimulation. beta is a map of the induced electric field per unit gradient slew rate, and can be calculated directly from the gradient coil wire pattern. Consideration of beta alone is sufficient to compare stimulation thresholds between different gradient coil designs, as well as to evaluate the expected dependency of stimulation threshold on position within the gradient coil. The linear gradient threshold curve is characterized by two parameters: SR(min) and DeltaG(min). SR(min) is the slope of the threshold curve and represents the minimum slew rate required to cause stimulation in the limit of infinite gradient strength. DeltaG(min) is the vertical axis intercept of the curve and represents the minimum gradient excursion required to cause stimulation in the limit of infinite slew rate. Both SR(min) and DeltaG(min) are functions of both beta and the standard tissue parameters E(r) (rheobase) and tau(c) (chronaxie time). The ease with which both the gradient system performance and the stimulation thresholds can be plotted on the same axes is noted and is used to introduce the concept of a piece-wise linear operational limit curve for a gradient system.


Subject(s)
Magnetic Resonance Imaging/instrumentation , Electric Stimulation , Electromagnetic Fields , Humans , Magnetics , Mathematics , Peripheral Nerves/physiology
9.
J Magn Reson Imaging ; 12(6): 991-1003, 2000 Dec.
Article in English | MEDLINE | ID: mdl-11105041

ABSTRACT

A technique for the simultaneous measurement of three vascular parameters: blood flow (Frho), blood volume (v(b)), and the capillary permeability-surface area product (PSrho) in breast tumors using dynamic contrast-enhanced magnetic resonance imaging (MRI) is presented. Features of the technique include measurement of precontrast tumor T(1), rapid temporal sampling, measurement of the arterial input function, and use of a distributed parameter tracer kinetic model. Parameter measurements are compared that were determined using two contrast agents of different molecular weights, gadolinium-diethylene triamine pentaacetic acid (Gd-DTPA; 0.6 kDa) and Gadomer-17 (17 kDa), in 18 spontaneous canine mammary tumors. Measurements of Frho and v(b) corresponded well with literature values, and the mean PSrho measured using Gd-DTPA was a factor of 15 higher than that measured using Gadomer-17. J. Magn. Reson. Imaging 2000;12:991-1003.


Subject(s)
Blood Flow Velocity/physiology , Blood Volume/physiology , Capillary Permeability/physiology , Contrast Media , Gadolinium DTPA , Gadolinium , Magnetic Resonance Imaging , Mammary Neoplasms, Experimental/blood supply , Animals , Dog Diseases/diagnosis , Dog Diseases/physiopathology , Dogs , Female , Mammary Glands, Animal/blood supply , Phantoms, Imaging , Sensitivity and Specificity
10.
Magn Reson Med ; 44(6): 955-63, 2000 Dec.
Article in English | MEDLINE | ID: mdl-11108634

ABSTRACT

The design, fabrication, and testing of a complete three-axis gradient coil capable of imaging the human neck is described. The analytic method of constrained current minimum inductance (CCMI) was used to position the uniform region of the gradient coil adjacent to and extending beyond the physical edge of the coil. The average gradient efficiency of the three balanced axes is 0.37 mT/m/A and the average inductance is 827 microH. With maximum amplifier current of 200A and receive signal sweep width of +/-125 kHz, the average minimum FOV using this gradient set is 7.9 cm. The completed coil has an inner diameter of 32 cm, an outer diameter of 42 cm, and a length (including cabling connections) of 80 cm. The entire coil was built in-house. The structure is actively water cooled. Heating measurements were made to characterize the thermal response of the coil under various operating conditions and it was determined that a continuous current of 100A could be passed through all three axes simultaneously without increasing the internal coil temperature by more than 23 degrees C. Eddy current measurements were made for all axes. With digital compensation, the gradient eddy current components could be adequately compensated. A large B(o) eddy current field is produced by the Gz axis that could be corrected through the use of an auxiliary B(o) compensation coil. Preliminary imaging results are shown in both phantoms and human subjects.


Subject(s)
Magnetic Resonance Imaging/instrumentation , Brain/anatomy & histology , Equipment Design , Head , Humans , Magnetic Resonance Imaging/statistics & numerical data , Neck
11.
Magn Reson Med ; 44(4): 532-6, 2000 Oct.
Article in English | MEDLINE | ID: mdl-11025508

ABSTRACT

Both the acoustic and magnetic fluctuation frequency response functions for a Siemens AS25 body gradient coil inside a 4 Tesla whole-body MR system were measured and analyzed in this study. In an attempt to correlate the acoustic noise inside the gradient coil with magnetic field oscillations, triangular and trapezoidal gradient impulses of varying amplitudes and widths were used to excite the gradient coil. The acoustic and magnetic responses to these inputs were measured. The results show the existence of discrete resonances in both acoustic and uniform magnetic field fluctuation spectra, while gradient magnetic field fluctuation spectra show no such resonances. In addition, the dominant amplitude peaks in spectra fluctuate similarly with respect to trapezoidal gradient impulse flat-top widths. This implies that these phenomena are correlated, and that the trapezoidal impulse flat-top width may be used as a way to suppress both acoustic noise and uniform magnetic field oscillations.


Subject(s)
Magnetic Resonance Imaging , Electromagnetic Fields , Humans , Magnetic Resonance Imaging/instrumentation , Noise
12.
Stroke ; 31(7): 1672-8, 2000 Jul.
Article in English | MEDLINE | ID: mdl-10884472

ABSTRACT

BACKGROUND AND PURPOSE: The relationship between middle cerebral artery (MCA) flow velocity (CFV) and cerebral blood flow (CBF) is uncertain because of unknown vessel diameter response to physiological stimuli. The purpose of this study was to directly examine the effect of a simulated orthostatic stress (lower body negative pressure [LBNP]) as well as increased or decreased end-tidal carbon dioxide partial pressure (P(ET)CO(2)) on MCA diameter and CFV. METHODS: Twelve subjects participated in a CO(2) manipulation protocol and/or an LBNP protocol. In the CO(2) manipulation protocol, subjects breathed room air (normocapnia) or 6% inspired CO(2) (hypercapnia), or they hyperventilated to approximately 25 mm Hg P(ET)CO(2) (hypocapnia). In the LBNP protocol, subjects experienced 10 minutes each of -20 and -40 mm Hg lower body suction. CFV and diameter of the MCA were measured by transcranial Doppler and MRI, respectively, during the experimental protocols. RESULTS: Compared with normocapnia, hypercapnia produced increases in both P(ET)CO(2) (from 36+/-3 to 40+/-4 mm Hg, P<0.05) and CFV (from 63+/-4 to 80+/-6 cm/s, P<0.001) but did not change MCA diameters (from 2.9+/-0.3 to 2.8+/-0.3 mm). Hypocapnia produced decreases in both P(ET)CO(2) (24+/-2 mm Hg, P<0.005) and CFV (43+/-7 cm/s, P<0.001) compared with normocapnia, with no change in MCA diameters (from 2.9+/-0.3 to 2.9+/-0.4 mm). During -40 mm Hg LBNP, P(ET)CO(2) was not changed, but CFV (55+/-4 cm/s) was reduced from baseline (58+/-4 cm/s, P<0.05), with no change in MCA diameter. CONCLUSIONS: Under the conditions of this study, changes in MCA diameter were not detected. Therefore, we conclude that relative changes in CFV were representative of changes in CBF during the physiological stimuli of moderate LBNP or changes in P(ET)CO(2).


Subject(s)
Cerebrovascular Circulation/physiology , Hypotension, Orthostatic/physiopathology , Magnetic Resonance Imaging , Middle Cerebral Artery/physiology , Adult , Blood Flow Velocity/physiology , Carbon Dioxide/analysis , Consciousness , Female , Humans , Hypercapnia/diagnosis , Hypercapnia/physiopathology , Hypocapnia/diagnosis , Hypocapnia/physiopathology , Hypotension, Orthostatic/diagnosis , Male , Pressoreceptors/physiology , Sympathetic Nervous System/physiology , Ultrasonography, Doppler, Transcranial
13.
J Magn Reson Imaging ; 11(6): 586-95, 2000 Jun.
Article in English | MEDLINE | ID: mdl-10862056

ABSTRACT

Magnetization transfer and multicomponent T2 imaging techniques were implemented to study guinea pig in vivo. A chronic-progressive model of experimental allergic encephalomyelitis (EAE) was produced, and the inflammatory component of the disease was manipulated using antibodies against integrin. The magnetization transfer ratio (MTR) and T2 relaxation properties were measured in normal-appearing white matter (NAWM) with histological comparisons. Significant reductions in both the mean MTR and the myelin water percentage were measured in NAWM of EAE guinea pig brain. However, the MTR and myelin water percentage appear to measure different aspects of pathology in NAWM in EAE. Reductions in the MTR were prevented or reversed with suppression of inflammation. However, modulation of inflammatory activity was not reflected in the measurement of the myelin water percentage. Since the amount of myelin is not expected to vary with inflammatory-related changes, these observations support our hypothesis that the MTR is sensitive to physiological changes to myelin induced by inflammation, while the short T2 component is a more specific indicator of myelin content in tissue. Pathologic features other than demyelination may be important in the determination of the MTR.


Subject(s)
Encephalomyelitis/diagnosis , Magnetic Resonance Imaging/methods , Multiple Sclerosis/diagnosis , Animals , Body Water/chemistry , Cross-Sectional Studies , Disease Models, Animal , Encephalomyelitis/pathology , Female , Guinea Pigs , Longitudinal Studies , Multiple Sclerosis/pathology , Myelin Sheath/chemistry , Sensitivity and Specificity
14.
MAGMA ; 10(2): 131-46, 2000 Jun.
Article in English | MEDLINE | ID: mdl-10873203

ABSTRACT

There is great interest in the non-destructive capabilities of magnetic resonance microscopy for studying murine models of both disease and normal function; however, these studies place extreme demands on the MR hardware, most notably the gradient field system. We designed, using constrained current minimum inductance methods, and fabricated a complete, unshielded three-axis gradient coil set that utilizes interleaved, multilayer axes to achieve maximum gradient strengths of over 2000 mT m(-1) in rise times of less than 50 micros with an inner coil diameter of 5 cm. The coil was wire-wound using a rectangular wire that minimizes the deposited power for a given gradient efficiency. Water cooling was also incorporated into the coil to assist in thermal management. The duty cycle for the most extreme cases of single shot echo planar imaging (EPI) is limited by the thermal response and expressions for maximum rates of image collection are given for burst and continuous modes of operation. The final coil is capable of the collection of single shot EPI images with 6 mm field of view and 94 microm isotropic voxels at imaging rates exceeding 50 s(-1).


Subject(s)
Magnetic Resonance Imaging/instrumentation , Microscopy/instrumentation , Animals , Biophysical Phenomena , Biophysics , Brain/anatomy & histology , Electric Impedance , Equipment Design , Evaluation Studies as Topic , Hot Temperature , Magnetic Resonance Imaging/methods , Magnetic Resonance Imaging/statistics & numerical data , Mice , Microscopy/methods , Microscopy/statistics & numerical data , Models, Theoretical , Phantoms, Imaging
15.
Phys Med Biol ; 45(4): 955-69, 2000 Apr.
Article in English | MEDLINE | ID: mdl-10795984

ABSTRACT

Two new Fricke dosimeter gel systems with low diffusion rates have been developed for 3D radiation dosimetry purposes. Both systems consist of a solution of 20% (by weight) polyvinyl alcohol (PVA) in a 50 mM H2SO4 solution with 0.4 mM ferrous ammonium sulphate and xylenol orange (FX). The difference in the two gels is the way that the gelation process was initiated: either by bringing the temperature to (a) +5 degrees C or (b) -20 degrees C before returning them to room temperature. These gels are termed 'hydrogel' and 'cryogel', respectively. The hydrogel is optically transparent, and can be used with either optical or MRI detection methods for dosimetric imaging. The cryogel is rubbery in texture but opaque, so its internal Fe3+ concentration can only be measured with MRI. The hydrogel's optical attenuation coefficient is linear (r2 = 0.99) with dose from 0 to 20 Gy with a sensitivity of 0.106 cm(-1) Gy(-1) (at 543 nm). In terms of MR relaxation rate, the dose response for both the hydrogel and cryogel was linear (r2 = 0.99) with a sensitivity of 0.020 s(-1) Gy(-1) (at 1.5 T). The Fe3+ diffusion coefficient (at 20 degrees C) was measured to be 0.14 mm2 h(-1), which is significantly lower than similar preparations reported for porcine gelatin or agarose. The PVA-FX gels can be stored for long periods of time before exposure to radiation, since the auto-oxidation rate was 10 times less than that of gelatin-Fricke recipes. The new gels developed in this work are a significant improvement on previous Fricke gel systems.


Subject(s)
Ions , Iron/chemistry , Radiometry/instrumentation , Radiometry/methods , Calibration , Diffusion , Dose-Response Relationship, Radiation , Ferrous Compounds/chemistry , Fluorescent Dyes/chemistry , Hydrogels/chemistry , Phenols , Polyvinyl Alcohol/chemistry , Quaternary Ammonium Compounds/chemistry , Sensitivity and Specificity , Sulfoxides , Temperature , Time Factors , Xylenes/chemistry
16.
Radiology ; 214(3): 787-94, 2000 Mar.
Article in English | MEDLINE | ID: mdl-10715047

ABSTRACT

PURPOSE: To evaluate two experimental blood pool agents for potential use in equilibrium phase abdominal magnetic resonance (MR) angiography. MATERIALS AND METHODS: MR imaging at 0.5 T was performed in 37 rabbits before and after intravenous injection of a gadolinium-based blood pool contrast agent (SH L 643 A), superparamagnetic iron oxide blood pool agent (SH U 555 C), or gadopentetate dimeglumine. T1-weighted fast spoiled gradient-echo images from the renal arteries to below the iliac bifurcation were obtained. The aorta-to-tissue signal difference-to-noise ratio (SDNR) was measured over time. RESULTS: Both blood pool agents yielded excellent demonstration of the rabbit abdominal aorta. At a dose of 0.1 mmol/kg, both provided a statistically significant increase in aorta-to-tissue SDNR in comparison with that achieved with gadopentetate dimeglumine (200% increase for SH L 643 A, 95% increase for SH U 555 C; P < .05). A 0.1 mmol/kg dose of SH L 643 A provided a 24% increase in SDNR relative to the increase with a 0.37 mmol/kg dose of gadopentetate dimeglumine. Time-dependent enhancement properties of the blood pool agents differed due to differences in elimination method. CONCLUSION: Both blood pool agents were found to be promising contrast agents for 0.5-T MR angiography; however, their clinical applicability warrants further investigation. The gadolinium-based agent had several advantages over the iron oxide compound, including less T2* dephasing, lack of susceptibility artifacts, and fast renal elimination.


Subject(s)
Contrast Media/pharmacokinetics , Gadolinium , Iron/pharmacokinetics , Magnetic Resonance Angiography , Oxides/pharmacokinetics , Abdomen/blood supply , Animals , Aortography , Contrast Media/administration & dosage , Dextrans , Ferrosoferric Oxide , Gadolinium DTPA/administration & dosage , Gadolinium DTPA/pharmacokinetics , Magnetite Nanoparticles , Male , Rabbits , Sensitivity and Specificity
17.
Magn Reson Med ; 43(2): 284-9, 2000 Feb.
Article in English | MEDLINE | ID: mdl-10680693

ABSTRACT

The design and operation of a detunable shielded hybrid birdcage RF head coil optimized for human brain imaging at 170 MHz is presented. A high duty-cycle and rapid-switching decoupling scheme that allows uniform RF transmission with the head coil and reception with a surface coil within the volume of the head coil is also demonstrated. In addition, the circumscribing hybrid coil can be biased to operate as a conventional transmit/receive head coil. Our RF design allows the use of higher sensitivity surface coils or phased-array coils at very high magnetic fields where body RF resonators are not currently available or whose use is precluded by specific-absorption ratio restrictions. The design also allows the use of receive-only coils within head gradient inserts, which normally do not allow transmission with an RF body resonator at any field strength.


Subject(s)
Magnetic Resonance Imaging/instrumentation , Magnetic Resonance Spectroscopy/instrumentation , Equipment Design/statistics & numerical data , Humans , Magnetic Resonance Imaging/statistics & numerical data , Magnetic Resonance Spectroscopy/statistics & numerical data , Phantoms, Imaging/statistics & numerical data , Radio Waves , Sensitivity and Specificity
18.
Ann Biomed Eng ; 27(5): 627-40, 1999.
Article in English | MEDLINE | ID: mdl-10548332

ABSTRACT

Study of the relationship between hemodynamics and atherogenesis requires accurate three-dimensional descriptions of in vivo arterial geometries. Common methods for obtaining such geometries include in vivo medical imaging and postmortem preparations (vessel casts, pressure-fixed vessels). We sought to determine the relative accuracy of these methods. The aorto-iliac (A/I) region of six rabbits was imaged in vivo using contrast-enhanced magnetic resonance imaging (MRI). After sacrifice, the geometry of the A/I region was preserved via vascular casts in four animals, and ex situ pressure fixation (while preserving dimensions) in the remaining two animals. The MR images and postmortem preparations were used to build computer representations of the A/I bifurcations, which were then used as input for computational blood flow analyses. Substantial differences were seen between MRI-based models and postmortem preparations. Bifurcation angles were consistently larger in postmortem specimens, and vessel dimensions were consistently smaller in pressure-fixed specimens. In vivo MRI-based models underpredicted aortic dimensions immediately proximal to the bifurcation, causing appreciable variation in the aorto-iliac parent/child area ratio. This had an important effect on wall shear stress and separation patterns on the "hips" of the bifurcation, with mean wall shear stress differences ranging from 15% to 35%, depending on the model. The above results, as well as consideration of known and probable sources of error, suggests that in vivo MRI best replicates overall vessel geometry (vessel paths and bifurcation angle). However, vascular casting seems to better capture detailed vessel cross-sectional dimensions and shape. It is important to accurately characterize the local aorto-iliac area ratio when studying in vivo bifurcation hemodynamics.


Subject(s)
Arteries/anatomy & histology , Arteries/physiology , Models, Cardiovascular , Animals , Aorta/anatomy & histology , Aorta/physiology , Hemodynamics/physiology , Iliac Artery/anatomy & histology , Iliac Artery/physiology , Image Processing, Computer-Assisted , Magnetic Resonance Imaging , Male , Rabbits , Regional Blood Flow , Stress, Mechanical
19.
Magn Reson Imaging ; 17(9): 1319-25, 1999 Nov.
Article in English | MEDLINE | ID: mdl-10576717

ABSTRACT

Multi-echo Carr-Purcell-Meiboom-Gill (CPMG) imaging sequences were implemented on 1.5 T and 4.0 T imaging systems to test their ability to measure in vivo multi-component T2 relaxation behavior in normal guinea pig brain. The known dependence of accurate T2 measurements on the signal-to-noise ratio (SNR) was explored in vivo by comparing T2 decay data obtained using three methods to increase SNR (improved RF coil design, signal averaging and increased magnetic field strength). Good agreement between T2 values of nickel-doped agarose phantoms was found between imaging and spectroscopic methods. T2 values were determined for gray matter (GM) and white matter (WM) locations from images of guinea pig brain in vivo. T2 measurements of GM were found to be monoexponential at both field strengths. The mean T2 times for GM were 71 ms at 1.5 T, and 53 ms at 4.0T. The highest average SNR was achieved using an improved RF coil at 4.0T. In this case, two peaks were extracted in WM, a "short" T2 peak at approximately 6 ms, and a "medium" T2 peak at approximately 48 ms. T2 values in GM and the major component of WM were significantly decreased at 4.0T compared to 1.5 T. The improved SNR attained with this optimized imaging protocol at 4.0T has allowed for the first time extraction of the myelin-sensitive T2 component of WM in animal brain in vivo.


Subject(s)
Brain/anatomy & histology , Electromagnetic Fields , Animals , Brain/physiology , Echo-Planar Imaging/instrumentation , Echo-Planar Imaging/methods , Female , Guinea Pigs , Nickel/metabolism , Phantoms, Imaging , Reference Values , Sepharose/metabolism , Spectrum Analysis/instrumentation , Spectrum Analysis/methods
20.
Biotechnol Bioeng ; 65(4): 459-67, 1999 Nov 20.
Article in English | MEDLINE | ID: mdl-10506421

ABSTRACT

Polyvinyl alcohol-cryogel (PVA-C) is a hydrogel that is an excellent tissue mimic. In order to characterize mass transfer in this material, as well as to demonstrate in principle the ability to noninvasively measure solute diffusion in tissue, we measured the diffusion coefficient of the magnetic resonance (MR) contrast agent gadolinium diethylene triaminopentaacetic acid (Gd-DTPA) through PVA-C using a clinical MR imager. The method involved filling thick-walled rectangular PVA-C "cups" with known concentrations of Gd-DTPA solutions. Then by using a fast inversion recovery spin echo MR imaging protocol, a signal "null" contour was created in the MR image that corresponded to a second, known concentration of Gd-DTPA. By collecting a series of MR images through the PVA-C wall as a function of time, the displacement of this second known isoconcentration contour could be tracked. Application of Fick's second law of diffusion yielded the diffusion coefficient. Seven separate experiments were performed using various combinations of initial concentrations of Gd-DTPA within the PVA-C cups (3.2, 25.6, or 125 mM) and tracked isoconcentrations contours (0.096, 0.182, or 0.435 mM Gd-DTPA). The experimental results and the predictions of Fick's law were in excellent agreement. The diffusivity of Gd-DTPA through 10% PVA hydrogel was found to be (2.6 +/- 0.04) x 10(-10) m(2)/s (mean +/- s.e.m.). Separate permeability studies showed that the diffusion coefficient of Gd-DTPA through this hydrogel did not change with an applied pressure of up to 7.1 kPa. Accurate measurements could be made within 30 min if suitable Gd-DTPA concentrations were selected. Due to the excellent repeatability and fast data acquisition time, this technique is very promising for future in vivo studies of species transport in tissue.


Subject(s)
Gadolinium DTPA/analysis , Hydrogels/chemistry , Magnetic Resonance Imaging/methods , Polyvinyl Alcohol/chemistry , Calibration , Diffusion , Gadolinium DTPA/chemistry