1.
Neurospine ; 20(3): 1028-1039, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37798995

ABSTRACT

OBJECTIVE: The objective of this study was to evaluate the accuracy of pedicle screw placement in patients undergoing percutaneous pedicle screw fixation with robotic guidance, using a newly developed 3-dimensional quantitative measurement system. The study also aimed to assess the clinical feasibility of the robotic system in the field of spinal surgery. METHODS: A total of 113 patients underwent pedicle screw insertion using the CUVIS-spine pedicle screw guide system (CUREXO Inc.). Intraoperative O-arm images were obtained, and screw insertion pathways were planned accordingly. Image registration was performed using paired-point registration and iterative closest point methods. The accuracy of the robotic-guided pedicle screw insertion was assessed using 3-dimensional offset calculation and the Gertzbein-Robbins system (GRS). RESULTS: A total of 448 screws were inserted in the 113 patients. The image registration success rate was 95.16%. The average error of entry offset was 2.86 mm, target offset was 2.48 mm, depth offset was 1.99 mm, and angular offset was 3.07°. According to the GRS grading system, 88.39% of the screws were classified as grade A, 9.60% as grade B, 1.56% as grade C, 0.22% as grade D, and 0.22% as grade E. Clinically acceptable screws (GRS grade A or B) accounted for 97.54% of the total, with no reported neurologic complications. CONCLUSION: Our study demonstrated that pedicle screw insertion using the novel robot-assisted navigation method is both accurate and safe. Further prospective studies are necessary to explore the potential benefits of this robot-assisted technique in comparison to conventional approaches.

2.
Bioengineering (Basel) ; 10(10)2023 Oct 13.
Article in English | MEDLINE | ID: mdl-37892914

ABSTRACT

Effective oral care is a critical requirement to maintain a high quality of life. Most oral diseases are caused by plaque (oral biofilm), which is also correlated with systemic diseases. A common method to remove biofilm is brushing teeth with toothpaste. However, 3.5 billion people in the world have oral diseases, meaning that more efficient methods of removing biofilms are needed. We have developed a toothbrush that applies a bioelectric effect (BE) utilizing an electric force for biofilm removal. It demonstrated significantly higher biofilm removal efficiency than non-BE manual toothbrushes. Tests were performed in saline and toothpaste conditions using various pressures. Results showed that the BE toothbrush had a significantly higher biofilm removal efficiency in saline (0.5 N: 215.43 ± 89.92%, 2.5 N: 116.77 ± 47.02%) and in a toothpaste slurry (0.5 N: 104.96 ± 98.93%, 2.5 N: 96.23 ± 35.16%) than non-BE manual toothbrushes. Results also showed that BE toothbrushes were less dependent on toothpaste. This study suggests that the application of BE can be a new solution to plaque problems in oral care.

3.
Int J Med Robot ; 18(6): e2442, 2022 Dec.
Article in English | MEDLINE | ID: mdl-35923117

ABSTRACT

BACKGROUND: This preclinical study emulating the clinical environment quantitatively analysed the accuracy of pedicle screw insertion using a navigated robotic system. METHODS: Pedicle screws were placed from T7 to L5 in the whole-body form of a cadaver. After the insertion of multiple artificial markers into each vertebra, errors between the planned insertion path and the inserted screw were quantified using the Gertzbein-Robbins system (GRS) and offset calculation. RESULTS: A total of 22 screws were placed. Almost all (95.45% [21/22]) were classified as GRS A or B, while one (4.55%) was GRS C. The mean and standard deviations of entry, tip, and angular offset were 1.78 ± 0.94 mm, 2.30 ± 1.01 mm, and 2.64 ± 1.05°, respectively. CONCLUSIONS: This study demonstrated that pedicle screw insertion using a navigated robotic system had high accuracy and safety. A future clinical study is necessary to validate our findings.